8
W415-0153 / B / 06.10.10
INSTALLER: It is your
responsibility to check off the
appropriate box on the rating
plate according to the model,
venting and gas type of the unit.
For rating plate location, see
“INSTALLATION OVERVIEW”
section.
This illustration is for reference
only. Refer to the rating plate on the
appliance for accurate information.
MODEL CDVS280/GDS28 APPROVEDFOR BEDROOM,
BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCOR-
DANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH
SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN
THE UNITED STATES THE MANUFACTURED HOME
CONTRUCTIONANDSAFETYSTANDARD,TITLE24 CFR, PART
3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE
THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANU-
FACTURED HOME INSTALLATIONS, SITES AND COMMUNI-
TIES, ANSI / NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBREA
COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE
POUR INSTALLATION DANS UNE MAISON MOBILE SI SON
INSTALLATION CONFORMEAUX EXIGENCES DE LA NORME
CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES
AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE
LA NORME DE SECURITE ET DE CONSTRUCTION DE
MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280.
DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVEAU
CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE
POUR LES INSTALLATIONS DANS LES MAISONS MANUFAC-
TURES,LES SITESETLES COMMUNAUTES,ANSI/NFPA501A
.
STEADY STATE EFFICIENCY (NG): 75% FAN OFF / 78% FAN ON
STEADY STATE EFFICIENCY (LP): 75% FAN OFF / 79% FAN ON
EFFICACITE CONSTANTE (GN): 75% VENT. ARRETE
78% VENT. FONCTIONNE
EFFICACITE CONSTANTE (GP): 75% VENTILATEURARRETE
79% VENTILATEUR FONCTIONNE
STEADYSTATEEFFICIENCYAPPLIES TO CANADAONLY / L'EFFICACITE
CONSTANTE S'APPLIQUENT SEULEMENTAUCANADA.
AFUE (NG/LP) (GN/GP): 64% / 65%
MINIMUMAND MAXIMUM HORIZONTAL VENTLENGTHS ARE
25 INCHES AND 20 FEETRESPECTIVELY. LES LONGUEURS
HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES
ET20 PIEDS RESPECTIVEMENT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRI-
ATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION
MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLA-
TION AND RESEALING IS NECESSARY AFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE
POUR L'EVACUATION PRECISE. ILEST IMPORTANT DE BIEN
REINSTALLER ET RESCELLER L'EVENT APRES AVOIR AS-
SURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
WOLF STEEL LTD
BARRIE,ONTARIO CANADA
MADE IN CANADA / FABRIQUE AU CANADA
W385-0165 / D
SERIALNUMBER
NO.DESERIE
MANIFOLDPRESSURE:3.5INCHESW.C.(NG)/10INCHESW.C.(LP)
PRESSIONAU COLLECTEUR:3.5"D'UNECOLONNE D'EAU(GN)
10" D'UNE COLONNE D'EAU (PG)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)
PRESSIOND'ALIMENTATIONMIN:4.5"D'UNECOLONNED'EAU(GN)
11" D'UNE COLONNE D'EAU (PG)
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSIOND'ALIMENTATIONMAX:7"D'UNECOLONNED'EAU(GN)
13" D'UNE COLONNE D'EAU (PG)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNITONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
SEULEMENTAVECCETTEUNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICHWILLCOMEINCONTACTWITHTHEFLAMES,OTHERTHAN
THAT SUPPLIED BYTHE MANUFACTURERWITHTHEAPPLIANCE.
AVERTISSEMENT: N'AJOUTEZPASACETAPPAREILAUCUN
MATERIAU DEVANT ENTRER EN CONTACT AVEC LES
FLAMMES AUTRE QUE CELUI QUI EST
APPAREIL PAR LE FABRICANT.
MINIMUMCLEARANCETO COMBUSTIBLE
DEGAGEMENTSMINIMAUXDESMATERIAUX
A7" D17½"
B2" E6¼"
C1" F9½"
20"TO CEILING FROM STOVE TOP
20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
MODEL CS280/GS28 APPROVED FOR BEDROOM, &
BEDSITTING ROOM INSTALLATION. HOMOLOGUE POUR IN-
STALLATION DANS UNE CHAMBRE A COUCHER, & UN
STUDIO.
STEADYSTATE EFFICIENCY(NG): 80%FAN OFF /82%FANON
STEADY STATEEFFICIENCY(LP): 80%FANOFF/83%FANON
EFFICACITE CONSTANTE (GN): 80% VENT. ARRETE
82% VENT. FONCTIONNE
EFFICACITECONSTANTE(GP): 80%VENTILATEURARRETE
83% VENTILATEUR FONCTIONNE
STEADYSTATEEFFICIENCYAPPLIESTOCANADAONLY /L'EFFICACITE
CONSTANTE S'APPLIQUENT SEULEMENTAUCANADA.
AFUE (NG/LP) (GN/GP): 66% / 68%
THISAPPLIANCEMUSTBE INSTALLEDUSINGANADAPTERKIT
GS-150KT. CETAPPAREIL DOIT ETRE INSTALLE EN UTILISANT
UNENSEMBLEADAPTATEURGS-150KT.
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT PAS
ETRE UTILISEAVEC CET APPAREIL GDS/CDVS28
ALTITUDE/ELEVATION
INPUT / ALIMENTATION
REDUCED INPUT /ALIMENTATION REDUITE
OUTPUT(CDVS280/GDS28)RENDEMENT
OUTPUT(CS280/GS28)RENDEMENT
ORIFICE / INJECTEUR
DIRECTVENTMODEL
‘B’VENT MODEL
0-4500FT (0-1370m)
30,000 BTU/h
18,000 BTU/h
22,500 BTU/h
24,000 BTU/h
#38
0-4500FT(0-1370m)
26,000 BTU/h
15,000 BTU/h
19,500 BTU/h
20,800 BTU/h
#54
CERTIFIEDUNDER:CSA2.33-2009,ANSIZ21.88-2009VENTEDGASFIREPLACEHEATER. APPLIANCEMUSTBEINSTALLEDUSING
BURNER KIT:GDS28BN-KT,ORGDS28BP-KT.
HOMOLOGUE SELON LES NORMES: CSA2.33-2009, ANSI Z21.88-2009 FOYER DE CHAUFFAGEAU GAZ AVEC EVACU-
ATION. CETAPPAREILDOITETRE INSTALLEENUTILISANT UNENSEMBLE DU BRULEUR:GDS28BN-KT,OUGDS28BP-KT.
CDVS280-N
CS280-N
GDS28-N
GS28-N
GDS28-P
GS28-P
CDVS280-P
CS28-P
REFERENCE # W/N 15486
2.4 RATING PLATE INFORMATION
M
IN
BIL
ME
I
ATE
TH
AN
AN
AFE
Y
I
NDA
DI
F
IR
AFE
Y
M
IN
AN
I
P
IN
A
L
P
IN
L
AN
A
Z24
M
A
AZ,
E
LA
M
AI
N
DAN
L
ETR
L
P
E
L
PLAF
1
1.
AM
P
Z
APPR
VED
M
IN
DAN
N
FFI
IEN
Y
FFI
IEN
Y