4 5
SURGICAL CRICOTHYROTOMY
Use the recommended scalpels for the procedure performed. (See figure 5.) Use the included lubricant
on airway appliances. (See figure 6.) Install the provided adult or child lung bag to determine the con-
firmed airway via the appropriate BVM (scalpels, airway appliances, and BVMs sold separately).
NEEDLE CRICOTHYROTOMY
A 20-22 gauge needle can be used through the cricothyroid membrane to confirm an airway. (See figure
7. ) Larger or smaller sized needles can be used as would be medically indicated; the cricoid and trachea
tubing will require more frequent replacement.
TRACHEOSTOMY TUBE PLACEMENT
Five tracheal rings are presented on the adult cricoid replica, and six tracheal rings on the child, for place-
ment of a permanent tracheostomy. Nasco recommends the adult tracheostomy tube 5-6 mm Shiley and
3-4 mm Shiley for the child. (See figure 8.)
CARE AND MAINTENANCE
Clean upper neck, cricoids, and neck skins with mild soap and water. For stubborn stains apply Nasco
Cleaner (LF09919U, sold separately) to the stained area and wipe with a clean cloth.
The clear base can be cleaned using glass cleaner. Ensure the base is completely dry before returning the
simulator to the base.
STORAGE
Make sure products are clean and dry before returning to the case. Place unused cricoids and neck skins
into resealable bags. A light dusting of baby powder will keep the products from becoming tacky. Store
the upper neck covered in unprinted plastic for elongated periods of time. Place all components into the
blue storage case.
CAUTIONS
Ink, ballpoint pen, and certain printed paper and plastics will leave an indelible stain when in contact with
the Cricothyrotomy Simulator. Simulate prepping (using water) the trainer at the beginning of the pro-
cedure like you would clean a person in a real scenario. Iodine or similar antiseptics may stain the trainer,
thus voiding the warranty.
Figure 5 Figure 6
Figure 7 Figure 8
TROUBLE SHOOTING
Use lubricant to place tubing back into cricoid. Use pliers to help remove tubing by firmly pulling. Use
provided lubricant to help glide any tubing into the trainer. Remove the lung bag, if used, before replacing
the cricoid. Never pull entire cricoid down through the small hole at the bottom of the upper neck. This
will damage the trainer thus voiding the warranty.
SUPPLIES/REPLACEMENT PARTS
LF00994(A)U (6) Neck Skins
LF00994(B)U (6) Adult Cricoids with Tubing, 2 open and 4 closed
LF00994(C)U (6) Child Cricoids with Tubing, 2 open and 4 closed
LF04096U Adult or Child Lung Bag
LF09919U Nasco Cleaner
Actual product may vary slightly from photo. Nasco reserves the right to change product color, materials,
supplies, or function as needed.