National Instruments TPC-2515 User manual

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

PPC-2115/TPC-2515
User Manual
PPC-2115/TPC-2515 User Manual
August 2009
372053C-01
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Support
Worldwide Technical Support and Product Information
ni.com
National Instruments Corporate Headquarters
11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100
Worldwide Offices
Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599,
Canada 800 433 3488, China 86 21 5050 9800, Czech Republic 420 224 235 774, Denmark 45 45 76 26 00,
Finland 358 (0) 9 725 72511, France 01 57 66 24 24, Germany 49 89 7413130, India 91 80 41190000,
Israel 972 3 6393737, Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400,
Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466,
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 328 90 10, Portugal 351 210 311 210,
Russia 7 495 783 6851, Singapore 1800 226 5886, Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197,
Spain 34 91 640 0085, Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 2377 2222,
Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545
For further support information, refer to the Technical Support and Professional Services appendix. To comment
on National Instruments documentation, refer to the National Instruments Web site at ni.com/info and enter
the info code feedback.
© 2007–2009 National Instruments Corporation. All rights reserved.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Important Information
Warranty
The PPC-2115/TPC-2515 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as
evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective
during the warranty period. This warranty includes parts and labor.
The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in
materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments
will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects
during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.
A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any
equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by
warranty.
National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In
the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document
without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National
Instruments be liable for any damages arising out of or related to this document or the information contained in it.
EXCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR APARTICULAR PURPOSE. CUSTOMER’SRIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL
INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING
FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of
the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against
National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in
performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service
failures caused by owner’s failure to follow the National Instruments installation, operation, or maintenance instructions; owner’s modification of the
product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside
reasonable control.
Copyright
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying,
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National
Instruments Corporation.
National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other
intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only
to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
Trademarks
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section
on ni.com/legal for more information about National Instruments trademarks.
Other product and company names mentioned herein are trademarks or trade names of their respective companies.
Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency,
partnership, or joint-venture relationship with National Instruments.
Patents
For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software,
the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.
WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS
(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT
INJURY TO A HUMAN.
(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY,
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE
COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES,
TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR
ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER
COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF
HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY
UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH,
THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES,
INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS
CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION
DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT
EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY
RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER
NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT
LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Compliance
Electromagnetic Compatibility Information
This hardware has been tested and found to comply with the applicable regulatory requirements and limits for electromagnetic
compatibility (EMC) as indicated in the hardware’s Declaration of Conformity (DoC)1. These requirements and limits are
designed to provide reasonable protection against harmful interference when the hardware is operated in the intended
electromagnetic environment. In special cases, for example when either highly sensitive or noisy hardware is being used in close
proximity, additional mitigation measures may have to be employed to minimize the potential for electromagnetic interference.
While this hardware is compliant with the applicable regulatory EMC requirements, there is no guarantee that interference will
not occur in a particular installation. To minimize the potential for the hardware to cause interference to radio and television
reception or to experience unacceptable performance degradation, install and use this hardware in strict accordance with the
instructions in the hardware documentation and the DoC1.
If this hardware does cause interference with licensed radio communications services or other nearby electronics, which can be
determined by turning the hardware off and on, you are encouraged to try to correct the interference by one or more of the
following measures:
• Reorient the antenna of the receiver (the device suffering interference).
• Relocate the transmitter (the device generating interference) with respect to the receiver.
• Plug the transmitter into a different outlet so that the transmitter and the receiver are on different branch circuits.
Some hardware may require the use of a metal, shielded enclosure (windowless version) to meet the EMC requirements for
special EMC environments such as, for marine use or in heavy industrial areas. Refer to the hardware’s user documentation and
the DoC1for product installation requirements.
When the hardware is connected to a test object or to test leads, the system may become more sensitive to disturbances or may
cause interference in the local electromagnetic environment.
Operation of this hardware in a residential area is likely to cause harmful interference. Users are required to correct the
interference at their own expense or cease operation of the hardware.
Changes or modifications not expressly approved by National Instruments could void the user’s right to operate the hardware
under the local regulatory rules.
1 The Declaration of Conformity (DoC) contains important EMC compliance information and instructions for the user or
installer. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line,
and click the appropriate link in the Certification column.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Conventions
The following conventions are used in this manual:
»The »symbol leads you through nested menu items and dialog box options
to a final action. The sequence File»Page Setup»Options directs you to
pull down the File menu, select the Page Setup item, and select Options
from the last dialog box.
This icon denotes a note, which alerts you to important information.
This icon denotes a caution, which advises you of precautions to take to
avoid injury, data loss, or a system crash. When this symbol is marked on a
product, refer to the Safety section of Appendix A, Specifications, for
information about precautions to take.
When symbol is marked on a product, it denotes a warning advising you to
take precautions to avoid electrical shock.
When symbol is marked on a product, it denotes a component that may be
hot. Touching this component may result in bodily injury.
bold Bold text denotes items that you must select or click in the software, such
as menu items and dialog box options. Bold text also denotes parameter
names.
italic Italic text denotes variables, emphasis, a cross-reference, or an introduction
to a key concept. Italic text also denotes text that is a placeholder for a word
or value that you must supply.
monospace Text in this font denotes text or characters that you should enter from the
keyboard, sections of code, programming examples, and syntax examples.
This font is also used for the proper names of disk drives, paths, directories,
programs, subprograms, subroutines, device names, functions, operations,
variables, filenames, and extensions.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

©National Instruments Corporation vii PPC-2115/TPC-2515 User Manual
Contents
Chapter 1
General Information
Introduction....................................................................................................................1-1
I/O Ports.........................................................................................................................1-1
Chapter 2
System Setup
Important Safety Information ........................................................................................2-1
Setup ..............................................................................................................................2-2
Touchscreen Calibration..................................................................................2-3
Dual Display Setting......................................................................................................2-4
Panel Mounting..............................................................................................................2-4
Chapter 3
Jumpers and Connectors
Jumper and Connector Functions ..................................................................................3-1
Jumper and Connector Locations ..................................................................................3-2
Appendix A
Specifications
Appendix B
Serial Port Settings
Appendix C
Watchdog Timer Programming
Appendix D
Accessory Kit Assembly Procedure
Appendix E
Touchscreen Configuration
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Contents
PPC-2115/TPC-2515 User Manual viii ni.com
Appendix F
Fuse Replacement
Appendix G
Features in Windows XP Embedded (TPC-2515)
Appendix H
Technical Support and Professional Services
Index
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

©National Instruments Corporation 1-1 PPC-2115/TPC-2515 User Manual
1
General Information
This chapter includes general information about the PPC-2115/TPC-2515
Human Machine Interface (HMI).
Introduction
The PPC-2115/TPC-2515 touch panel computer, a state-of-the-art HMI
based on an x86 platform, includes these key features:
•Fanless—Because the system uses a low-power processor, it does not
need fans, which often are unreliable and cause dust to circulate inside
the equipment.
•Bright display—The TFT LCD features a 15 in. display that meets
industrial demands for clear interfaces.
•Powerful communication capability—The PPC-2115/TPC-2515 is a
powerful I/O interface for easy communication with other devices. The
I/O interface includes serial ports, an RS485 port, a parallel port, and
Ethernet and USB 2.0 support.
•Windows Operating System—The PPC-2115 and TPC-2515 support
the Windows XP and Windows XP Embedded platforms, respectively.
I/O Ports
The PPC-2115/TPC-2515 includes the following ports:
• One parallel port that supports EPP/ECP/SPP modes
• Three serial ports: RS232 (COM1 and COM3) and RS232/422/485
(COM4)
• Two RJ-45 Ethernet ports: LAN 1 (10/100BaseT) and LAN2
(10/100/1000BaseT)
• One PS/2 port: 6-pin mini-DIN port for keyboard and mouse
• Two USB ports compliant with USB 2.0
• One CompactFlash slot
• One PCMCIA slot
• Three audio ports: one microphone, one line in, and one line out
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Chapter 1 General Information
PPC-2115/TPC-2515 User Manual 1-2 ni.com
Figure 1-1 shows the I/O port arrangement.
Figure 1-1. I/O Port Arrangement
For more PPC-2115/TPC-2515 specifications, see Appendix A,
Specifications.
1 Parallel Port
2LAN1
3LAN2
4USB
5 PS/2
6 COM3 (RS232)
7 COM4 (RS232/422/485)
8 COM1 (RS232)
9VGA
123456789
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

©National Instruments Corporation 2-1 PPC-2115/TPC-2515 User Manual
2
System Setup
This chapter includes setup information for the PPC-2115/TPC-2515.
Important Safety Information
Before setting up the PPC-2115/TPC-2515, read these safety instructions
carefully.
Disconnect this equipment from any AC outlet before cleaning. Use a damp
cloth. Do not use liquid or spray detergents for cleaning.
For plug-in equipment, the power outlet socket must be located near the
equipment and must be easily accessible.
Keep this equipment away from humidity.
Place this equipment on a reliable surface during installation. Dropping it
or letting it fall may cause damage.
The openings on the enclosure are for air convection. Protect the equipment
from overheating. Do not cover the openings.
Make sure the power source voltage is correct before connecting the
equipment to the power outlet.
Position the power cord so that people cannot step on it. Do not place
anything over the power cord.
All cautions and warnings on the equipment should be noted.
If the equipment is not used for a long time, disconnect it from the power
source to avoid damage by transient overvoltage.
Never pour any liquid into an opening. This may cause fire or electrical
shock.
Never open the equipment. For safety reasons, only qualified service
personnel should open the equipment.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Chapter 2 System Setup
PPC-2115/TPC-2515 User Manual 2-2 ni.com
If one of the following situations arises, have service personnel check the
equipment:
• The power cord or plug is damaged.
• Liquid has penetrated into the equipment.
• The equipment has been exposed to moisture.
• The equipment does not work well, or you cannot get it to work
according to the user manual.
• The equipment has been dropped and damaged.
• The equipment has obvious signs of breakage.
Do not leave this equipment in an environment where the storage
temperature may go below –20 °C (–4 °F) or above 60 °C (140 °F). Doing
so could damage the equipment. The equipment should be in a controlled
environment.
Caution There is a danger of explosion if the battery is incorrectly replaced. Replace the
battery only with the same or equivalent type recommended by the manufacturer. Discard
used batteries according to the manufacturer’s instructions.
The sound pressure level at the operator’s position according to
IEC 704-1:1982 is no more than 70 dB (A).
Setup
Follow these steps to set up the PPC-2115/TPC-2515:
1. Unpack the PPC-2115/TPC-2515. Be sure your kit includes the
following items:
• The PPC-2115/TPC-2515 HMI
• Eight panel mounting clamps
• Eight panel mounting screws
• One 3-pin power connector and wire
• One PS/2 splitter cable
• One HMI Resource CD
• One CompactFlash to IDE adapter card
If any items are missing or damaged, contact National Instruments.
Caution Be sure system power is off before plugging in or pulling out the
CompactFlash card.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Chapter 2 System Setup
©National Instruments Corporation 2-3 PPC-2115/TPC-2515 User Manual
2. Connect the power connector to 24 VDC power lines. Be sure
to connect the positive, negative, and ground lines as shown in
Figure 2-1. The power lines can be from either a power adapter or
in-house power source.
Figure 2-1. Power Connector
3. Connect the power connector to the power receptor on the
PPC-2115/TPC-2515. The power receptor pin assignment is shown in
Figure 2-2.
Figure 2-2. Power Receptor and Pin Assignment
4. Press the power button to power on the system.
Touchscreen Calibration
The PPC-2115/TPC-2515 touchscreen should be correctly calibrated and
ready to use when you power on the system. However, if the calibration is
not correct or you want to choose custom calibration options, refer to
Appendix E, Touchscreen Configuration.
+–GND
GND –+
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Chapter 2 System Setup
PPC-2115/TPC-2515 User Manual 2-4 ni.com
Dual Display Setting
To use an auxiliary CRT monitor with the PPC-2115/TPC-2515, connect
the monitor to the CRT port on the PPC-2115/TPC-2515. Follow these
steps to configure the CRT monitor settings:
1. After powering on the system, click the Intel icon in the toolbar on the
PPC-2115/TPC-2515 LCD monitor.
2. Select Graphics Options»Output Device.
3. The display options window appears, showing the currently active
display device. Use this window to select and configure alternate
display devices.
Panel Mounting
Follow these steps to mount the PPC-2115/TPC-2515 in a panel:
1. Be sure the adhesive waterproof gasket on the front bezel is in position.
2. Install the PPC-2115/TPC-2515 into the panel opening. (Refer to
Appendix A, Specifications, for cutout dimensions.)
3. Attach the clamps included in the accessory pack to the holes in the
bezel.
4. Insert the screws included in the accessory pack into the clamps.
Tighten the screws to fasten the PPC-2115/TPC-2515 against the
panel.
Note The mounting panel thickness should be less than 6 mm (0.236 in.).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

©National Instruments Corporation 3-1 PPC-2115/TPC-2515 User Manual
3
Jumpers and Connectors
This chapter describes the PPC-2115/TPC-2515 jumpers and connectors.
Jumper and Connector Functions
Table 3-1 lists the jumper and connector functions.
Table 3-1. Mainboard Connectors and Jumpers
Label Function Description
CN1 VGA D-Sub 15-pin (female) on
panel
CN2 DC in DC power in connector
(5.08 mm, 3-pin housing)
CN3 PCMCIA One-slot PCMCIA
connector
CN4 LCD power LCD inverter connector
CN5 PS2 Standard mini-DIN 6-pin
supports keyboard and
mouse
CN7 USB Two USB type-A female
CN9 IDE Internal IDE 44-pin
(2 mm) connector
CN10 PRT D-Sub 25-pin (female)
CN11 CF CompactFlash socket
CN12 Speaker out Internal speaker connector
CN13 Mic in Audio mic in
CN14 Line out Audio line out
CN15 Line in Audio line in
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Chapter 3 Jumpers and Connectors
PPC-2115/TPC-2515 User Manual 3-2 ni.com
Jumper and Connector Locations
Figure 3-1 shows the jumper and connector locations.
CN16 * (JP1) LVD S L CD Internal 18-bit LVDS
LCD connector
CN17 * (JP3) Touch Internal touchscreen
connector
COM1 COM1 Serial port: COM1 RS232
COM3 COM3 Serial port: COM3 RS232
COM4 COM4 Serial port: COM4
RS232/422/485
S1 COM4 MODE1 Setting COM4
RS232/422/485 mode
S2 COM4 MODE2 Setting COM4 RS422
master or slave mode
JP4 Clear CMOS Clear CMOS
SW1 Power switch System power switch
Table 3-1. Mainboard Connectors and Jumpers (Continued)
Label Function Description
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Chapter 3 Jumpers and Connectors
©National Instruments Corporation 3-3 PPC-2115/TPC-2515 User Manual
Figure 3-1. Mainboard Jumpers and Connectors
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

©National Instruments Corporation A-1 PPC-2115/TPC-2515 User Manual
A
Specifications
Physical
Weight.................................................... 5.5 kg (without HDD)
Cutout dimensions.................................. 373.5 ×297.5 mm (suggested)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Appendix A Specifications
PPC-2115/TPC-2515 User Manual A-2 ni.com
Dimensions
383 mm
[15.079 in]
373mm
[14.685 in]
4.5 mm [0.177 in]
64 mm [2.52 in]
297 mm [11.693in]
307 mm [12.087 in]
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Appendix A Specifications
©National Instruments Corporation A-3 PPC-2115/TPC-2515 User Manual
System Kernel
CPU........................................................ Intel Celeron M (clock rate
600 MHz/1 GHz)
BIOS....................................................... Award 4 Mbit flash memory
South bridge ........................................... Intel 855GME/852GM
GMCH/ICH4 chipset
VGA ....................................................... Intel 855GME for
PPC-2115/TPC-2515-A series;
Intel 852GM for
PPC-2115/TPC-2515-B series;
supports 16 MB frame buffer with
system memory; simultaneous
support of CRT and LVDS flat
panel display
Ethernet .................................................. Intel 82562EZ and
Intel 82551QM Ethernet
controller; IEEE 802.3u protocol
compatible
Watchdog timer...................................... W83627 watchdog timer;
1.6 s timeout period
IDE ......................................................... 2 EIDE channels support one IDE
compact flash socket onboard and
one 44-pin (2 mm) connector
LCD
Display type ........................................... TFT color LCD
Size (diagonal) ....................................... 15 in.
Maximum resolution .............................. 1024 ×768 (XGA)
Maximum colors .................................... 256,000
Pixel pitch (W ×H, mm)........................ 0.3075 ×0.3075
Viewing angle ........................................ 120
Luminance (cd/m2)................................. 350
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
This manual suits for next models
1
Table of contents
Other National Instruments Touch Panel manuals

National Instruments
National Instruments TPC-2206 User manual

National Instruments
National Instruments PPC-2115 User manual

National Instruments
National Instruments TPC-2230 User manual

National Instruments
National Instruments TPC2106T User manual

National Instruments
National Instruments Touch Panel Computer TPC-2012 User manual