Nautilus DigAlert 350 User manual

Black / Tip / +Ve
Green
/ Earth
Red / Ring / -Ve
LOW BATTERY
INSTALLING or REPLACING THE
BATTERY
A red LED at the centre of the keypad starts to
flash RED when the battery needs replacing.
Also, at each mode change of the
, a low battery tone will be heard. Once
the low battery LED is on, will
keep on working to its specification for a
couple of hours, but
.
Remove the three hatch cover screws as
shown below. Unclip the battery and replace
it with a 9V alkaline battery. Make the change
within one minute if you want to retain your
memory contents.
Disconnect from the line and press Monitor
button to extinguish the Green (Mode) LED.
Replace the hatch cover ensuring that the line
cord is correctly routed.
Tighten the screws firmly but do not use
excessive force.
DigAlert
350
DigAlert 350
DigAlert
350
you are advised to
replace the battery as soon as possible
It is very important to ensure that
is off when replacing a battery (No
LED lit).
If you do not do this, when the new battery
is fitted, the test-telephone may not restart
correctly.
m
To cure it, disconnect the battery
for at least 2 minutes and short the terminals
together for a few seconds (when battery not
fitted).
Care and repair
Field repair
Line-cord changing
Line-cord storage
Impact
Field repairs are limited to replacing line cords
(with approved types), replacing belt clips,
and replacing batteries. Attempting any
repair beyond this at field level is liable to
damage the instrument and will invalidate the
manufacturers warranty.
Remove the three hatch cover screws.
Replace the cord by loosening the terminal
screws. Connect a new, standard cord as per
the diagram. Tighten the screws firmly but do
not use excessive force. Make sure the
battery cover locates properly before
securing it with the 3 screws.
Wrap the line cord loosely around the handle
or preferably make a few loops and pass them
through the belt clip.
is highly impact resistant. Even
if dropped from a great height onto concrete
should survive without
permanent damage. In the event that the
gasket seal should bulge out on impact it is
usually possible to gently ease it back into
position with a blunt tool. Do not attempt to
open the case to make a repair nor should any
force be used or the gasket may split. If a
simple local fix is not possible it should be
returned for repair.
As a result of impact the surface may be
scuffed or gouged. Small scuffs may be
removed with fine grit abrasive paper. Any
sharp burrs resulting from impact may be cut
off with a sharp knife. Do not cut into the body
or this will break the water sealing.
Please note that the waterproof seal integrity
can be damaged by a high impact. If in doubt,
please have your unit checked. Use of the
unit while the seals are damaged may
invalidate the warranty.
DigAlert 350
DigAlert 350
Do not open the case.
D350 User Guide part n° 1201-03-2571 issue 2, 10/01, Sheet 1.
Warranty
Warranty covers all defects of manufacture
and materials.
Chesilvale Electronics agrees to remedy
warranty defects free of charge provided that:
the product is returned pre-paid to the
supplier, it is adequately packed and labeled,
all parts are returned and warranty seals (if
fitted) are not broken.
Warranty does not cover: normal wear and
tear, accidental damage, misuse, abuse or
neglect and is voided by any unapproved
modification.
USER GUIDE
Loud Speaker Test Telephone
range
DigAlert 350
™
Tempo Europe Ltd.
Unit 3,
Maesglas Industrial Estate,
Newport,
NP20 2NN
U.K.
(
4
+44 (0) 1633-223 552
+44 (0) 1633-223 948
www.tempo.textron.com
ü

?
1
2
3
4
5
6
7
8
9
0
#
Red: Talk Mode.
Green: Monitor mode.
Red lead polarity:
Green = B(-Ve).
= A (+Ve).Red
PULSE FLASH VOL
MEMLNR/PAUSE STO POL
SPKR
TONE
TALK
MONITOR
MUTE
DIALLING
PULSE Dialing
Mixed Pulse and Tone dialling
Storing a number in memory
STO MEM
Dialling a number from a memory
location.
LNR/PAUSE: Last Number
Redial and Pause
DTMF/TONE is the default dialling mode.
With the DigAlert™ connected to a live line,
press before selecting
mode. This is confirmed by a single high
beep. Dialling mode will automatically revert
to Tone when the line is disconnected or if the
is switched off.
Select Pulse mode as above and dial the
Pulse digits. Press (Tone) then dial the
Tone digits (the star will not be dialled out).
This can be stored in memory.
There are ten memory locations, one under
each of the dialling digits.
While connected to a line and in
mode:
Press on the keypad. Enter the
telephone number.
Press . Press the storage button
location 0-9.
The number is stored under the button
chosen. ln memory you may also store ,#,
or . These will be
redialled as they were entered.
While connected to a line and in TALK
mode:
Press the location digit 0-9.
The stored number under that button will be
redialled.
Press immediately after
off-hook to redial the previous number dialled.
During dialling, if you press
the Pause function operates. This inserts a 4
second pause in the dialling out string.
Dialling resumes at the end of the pause.
p
Sr
l
pt
*
t
S
r
*
fl
t
r
l
l
PULSE Talk
TALK
STO
MEM
Flash Pause
MEM then
LNR/PAUSE
LNR/PAUSE
DigAlert 350
fFLASH
POL: POLARITY TEST
SPKR: SPEAKER MODE
Ground-start lines
ELR: Earth Loop Recall
FLASH
POL
RED
GREEN
SPKR
SPKR
VOL
On units fitted with optional third wire
(item M0023/15):
On units fitted with optional third wire
(item M0023/15):
A timed line break is generated when the
button is pressed.
Press and observe the polarity
LED.
LED: red lead is connected toA(+Ve).
LED: red lead is connected to B(-
Ve).
During this test, remains high
impedance and will not interfere with data or
speech calls.
Press to activate the speaker
function. If is pressed while
is off, then Loud-speaker
Monitor is automatically activated.
Press and release to select the
high setting, press again to return to the
normal setting.
In TALK mode, receive only is possible while
in speaker mode.
After disconnection from the line for more
than 1.5 minutes, automatically
switches off and the time-out tone is heard.
connect green wire to
ground, press TALK momentarily and
check for dial tone. Ground start is then
automatic and the green wire can be left
connected to ground, without affecting the
call.
while in TALK mode on a
looped line and with the green wire to ground,
press PULSE momentarily and check
for second dial tone.
f
P
s
s
v
t
p
P
s
DigAlert 350
DigAlert 350
DigAlert 350
Volume adjustment:
t
m
M
TALK MODE
MONITOR MODE
MUTE
Press to go off-hook.
A double beep is heard and the mode LED
flashes .
Press to go back on-hook. The
mode LED then flashes .
: if is connected
to an overvoltage or a digital signal, then
does not loop the line and
sounds an alarm.
Connect to the line.
Press and release to go off-hook.
Thanks to , there are four different
cases:
1\A digital signal is present:
is heard, locks out and does not
loop the line. To override this alarm, hold
down the key.
2\ A high DC level is present (>116V±4V):
is heard,
locks out and does not loop the line. This
alarm may not be overridden.
3\ A dc level between 76V(±4V) and
116V(±4V) is present: is
heard, the mode LED flashes
, locks out and does not
loop the line. To override this alarm, press
again.
4\ No alarm (i.e. no digital signal nor high DC
present): goes off-hook and
loops the line.
Press . The mode LED flashes
. Press again to switch
off .
In order to extend its battery life, Monitor is
automatically switched off after 20 minutes, if
connected to a powered line, and 1.5 minute
after disconnection.An audible signal is heard
on timing out.
Press and release to cut off
transmission. Press again to talk.
t
m
t
t
t
m
m
M
TALK
RED
MONITOR
GREEN
TALK
a two tone alarm
TALK
a
single tone alarm
a single tone alarm
RED and
GREEN
TALK
Digital signal detection OVERRIDE
MONITOR
GREEN MONITOR
MUTE
PLEASE NOTE DigAlert 350
DigAlert 350
DigAlert 350
DigAlert 350
DigAlert 350
DigAlert 350
DigAlert 350
DigAlert 350
AUTOMATIC PROTECTION OF
DIGITAL LINES:
When connected to normal DC, it is possible to
override the digital detection lock-out by pressing
and holding for more than 6 seconds and
until the override tones have stopped. This can be
particularly useful on a faulty line being highly
imbalanced.
tTALK
(high Z).
DigAlertTM
Replace
Battery