APPLICATION
The GS Series 12VDC, 24VDC and 24VDC High Output luminaires are designed for use in hazardous
locations, indoors, outdoors, wet location, and areas containing moisture, dirt, corrosion, vibra-
tion, and rough usage. As dened by the National Electrical Code (NEC) and the Canadian Electrical
Code (CEC), they are suitable for use in the following areas:
Certied to: UL 844, UL 1598, UL 1598A and UL 2108;
CSA 22.2 No. 137 and CSA 22.2 No. 250.0
Hazardous Location Certications:
Class I, Division 2, Groups ABCD, T4*;
Class II, Division 2, Groups FG. T6*;
Class III;
Class I, Zone 2, Group IIC;
Zone 22
*T3C for simultaneous exposure rating, Class I Div. 2 & Class II, Div. 2
Housing: Copper-free Aluminium with Polycarbonate lens
Mounting: (A) Adjustable: Four 1/4”-20 x 4” Screws or bolts (Not Provided)
(B) Carriage Bolt: Two 1/4“-20 x 1”Bolts (Integral to luminaire)
Flat washers, lock washers & 1/4”-20 nuts (Provided)
Input Voltage: 12: 11-16VDC | 24: 22-28VDC | 24H: 22-28VDC
Electrical Ratings: 12 Models (@ 10-16VDC): GS-1: 0.75A | GS-2: 1.5A | GS-3: 2.3A | GS-4: 3.0A
24 Models (@ 22-28VDC): GS-1: 0.40A | GS-2: 0.75A | GS-3: 1.1A | GS-4: 1.5A
24H Models (@ 22-28VDC): GS-1: 0.75A | GS-2: 1.5A | GS-3: 2.2A | GS-4: 2.9A
Connections: 3ft extra hard usage cord with ying leads
Black: Negative (-) | White: Positive (+) | Green: Ground
DC Class 2 Wiring Only
Temperature Range: -40°C to +60°C
Ingress Protection: IP 66/67 | Suitable for Wet Locations. Marine Outside type (Salt Water).
(Luminaire enclosure only)
E477829
TM
GS-DC-HAZ
rev. A-12
1-3
MADE IN CANADA