
7. Manufacturer's warranty
Remote Control Radio 8101-1M................................................................................................................................................................................ 1 pc.
Passport....................................................................................................................................................................................................................... 1 pc.
Individual packing........................................................................................................................................................................................................ 1 pc.
At the end of the service life the device is subject to disposal in accordance with the legislation of the country where the item is used. The device
does not pose a hazard to human health and environment. The device does not contain any non-ferrous and precious metals. Waste batteries
should be disposed separately from mini remote controls.
9. Acceptance Certificate
Remote Control Radio 8101-1M (see serial number on the first page) is manufactured in conformance with RB TR 100376351.002-2003, is
approved by QCD and is classified as fit for operation.
10. Potential failures
8. Package contents
Guaranteed storage life is 6 months from the manufacturing date (the last 6 figures in the product serial number, for example: 191117 –
November 19, 2017).
Guarantee service life is 24 months from the date of sale.
Without the sale indicating mark – from the manufacturing date.
Warranty obligations cease in case of non-observance of operating conditions established by the manufacturer and mechanical damage during
operation. Warranty obligations do not apply tin case of failure to present the device passport.
Repair is made within the warranty period. Maintenance is carried out by the manufacturer's dealer or by the manufacturer himself.
5. Storage and transportation, service life
Average service life of the device is at least 5 years.
6. Disposal
4. Current maintenance
The devices should be stored in packing at temperatures from +5°C to +40°C and relative humidity of not more than 80% in heated and
vented warehouses, in air-conditioned depots without corrosive contaminants, conductible dust, acid and alkali vapors and gases causing
corrosion and insulation breakdown. During storage, sharp fluctuations in temperature (more than 3°C/min) and humidity (more than
5%/min) are not allowed.
The devices should be transported packaged, in containers, closed railway cars, heated and air-tight compartments of aircraft and holds and
by trucks with rain and snow protection for any distances at temperatures from -50°C to +50°C and relative humidity not more than 100% -
at 25°C. When transporting items, protection against dust and atmospheric precipitation must be provided.
The remote control is not recorded in
the executive devices.
1. Battery has run down (LED is off or blinks when
pressing the remote control).
2. The remote control operates in dynamic mode.
1. Change battery.
2. Change the operation mode from dynamic to
static one.
2
DPM from the preprogrammed remote control
1. Start DPM on the executive device from the preprogrammed remote
control: enter remote control programming mode, press remote control
button and hold it for more than 4 sec, after «DOWN-UP» movement of
the roller shutter curtain release and press short remote control button
two times.
2. In the DPM the following actions can be carried out:
a) record of new channels of remote controls;
c) memory erasing: press and hold the button for more than 4 sec. in
the programming mode;
b) deletion of channels of recorded remote controls from the memory
of executive device;
d) exit from the DPM: press short the remote control button with
which entering to the DPM was carried out.
b) Roller shutter curtain will make long-term movement
«DOWN-UP».
c) Roller shutter curtain will make long-term movement
«DOWN-UP» twice.
d) Roller shutter curtain will make short-term movement
«DOWN-UP» twice.
1. Roller shutter curtain will make a short-term movement «DOWN-
UP» once, and after 5 sec. by repeated short-term movement
«DOWN-UP» it will confirm entering in the DPM.
2. Indication on the drive unit:
a) Roller shutter curtain will make long-term movement
«DOWN», short-term movement «UP-DOWN», and long-term
movement «UP».
3. Distance Programming Mode (DPM)
Made in Belarus Ver. 1
Tel.: +7 495 430-79-60
+7 495 735-64-47
info@nerosk.ru
8 800 5000-930
SketchNero Group LLC
technical support:
Representative offices
in Russian Federation:
15, Bolshaya Ochakovskaya St.,
119361, Moscow.
Manufacturer and representative
office in Belarus
Minsk FEZ, 223016, Minsk district,
Novy Dvor Rural Council, 74
technical support:
+375 29 610-12-53
by-order@neroelectronics.by
www.neroelectronics.by
+375 29 609-25-59
Nero Electronics LLC
Tel.: +375 17 388-53-00
ua-order@neroelectronics.by
technical support:
Umnye resheniya LLC
Representative office
in Ukraine:
21, B. Khvoyki St., Office ,
03022, Kiev.
Tel.: +38 067 679-51-22
+38 044 500-18-55
+380 67 679-51-22
Nero SPb LLC
Tel.: +7 812 987-51-56
+7 981 757-90-45
spb-order@neroelectronics.by
8 800 5000-930
14, Komsomola St., Build. 2,
195009, St. Petersburg
technical support: