4.1. Button Test
Press the test/mute button, if the red indicator light flashes quickly and meanwhile alarm is given, it
means the detector is working properly. At the same time, the detector enters low sensitivity detecting
state. About 9 minutes later, it enters normal detecting state from low sensitivity detecting state
automatically.
4.2. Low sensitivity detection (silent mode)
1. Use a small amount of smoke to make the detector alarm, and press the test/mute button. Then the
detector will enter low sensitivity detection and exit alarm state. The detector is silent (and will enter
normal detection state after 9 minutes), and won't alarm until smoke concentration is higher.
2. Press the test/mute button again and you can cancel low sensitivity detection. The detector will enter
normal detection state.
Note: After canceling low sensitivity detection, if there is some residual smoke, the detector will
continue to alarm.
5. Alarm memory
After alarm is made, the detector will have alarm memory. The green LED will flash every 1.3 seconds
for 3 times, which will last for 43 seconds. So the user can tell if the detector has entered alarm state
from a distance without touching the detector. LED display will quit after 24 hours. The first time you
press the test/mute button after alarm is made, the detector will hint by special alarm mode. After
releasing the test/mute key, alarm memory will be purged. Then you press the test/mute button and it
will be normal key test.
Installation
1. Choose a suitable installation position.
2. According to the holes of mounting plate, drill a hole in the needed place of ceiling and stuff the plastic
3. Use the screw to fix the mounting plate onto plastic nail seat.
4. Embed the two snap joints on the detector base into the detector slot. Turn the product clockwise in
order to fasten it to the mounting plate tightly.
5. Test after the installation. Press the test/hush button, if the red indicator light flashes quickly and
continue alarms at the same time, it means the detector is working properly. At the same time, the
detector enters low sensitivity detecting state, the red LED light flashes every 10 seconds. About 9
minutes later, it enters normal detecting state from low sensitivity detecting state automatically or press
the test/mute button again and cancel low sensitivity detecting state.
1. It is better to test the smoke alarm weekly.
2. Clean the alarm every three months.
3. If you find the products are not in normal working state, check failure analysis and elimination first. If the
problem can not be removed, please do not dismantle by yourself. You shall seek the service of the