RESTORE FACTORY SETTINGS
1. Remove the batteries from the smoke alarm.
2.PresstheTestbuttonandkeepitdepressedwhilere-
insertingthebatteries.TheLEDindicatorlightsup.
3.ContinuetokeeptheTestbuttondepresseduntilthe
LEDindicatorturnso.
4.PresstheTestbuttonagain;youwillhearashort
beep to indicate that the smoke alarm has been
reset.
OPERATION
During normal operation, the smoke alarm light diode
ashesevery50seconds.Thisindicatesthatthe
batteriesandtheunitarefunctioningcorrectly.Ifthe
alarm detects smoke, it will emit a loud, pulsating noise
and the red light diode will light up with varying intensity
until the smoke has been dispersed.
PAUSE FUNCTION
Thesmokealarmhasacombinedbuttonforitstest
and pause functions. You can use the pause function
to interrupt the alarm signal if it has been triggered by
afalsealarm.Toactivatethepausefunction,pressthe
Test/Pausebuttonwhiletheunitisemittingitsalarm.
Thiswillpausethealarmfortenminutes.Thesmoke
alarm will return to normal sensitivity at the end of the
10-minutepauseperiod.Ifnecessary,presstheTest/
Pausebuttonagaintopausethealarmoncemore.If
you have several smoke alarms connected in series,
youcanpausealllinkedunitsbypressingtheTest/
Pause button on the unit that triggered the alarm.
REPLACING THE BATTERIES
How often you need to replace the batteries depends
on the type of battery. However, it is a good idea to
replace batteries regularly, once a year, and ideally on a
set date.
1.Turnthesmokealarmanti-clockwisetoreleaseit
from the base plate.
2. Remove the old batteries.
3.Insertnewbatteries.Checkthatthepoles(+/-)are
positioned correctly.
4. Place the smoke alarm on the base plate and turn it
clockwise until it clicks into position.
5.PresstheTestbuttontotestthesmokealarm.
COMMON CAUSES OF FALSE ALARMS AND
HOW TO AVOID THEM
A smoke alarm detects and reacts to smoke particles
intheair.Thesmokeparticlestriggerthealarm’saudio
signal. However, this sensitivity does mean that the smoke
alarm also reacts to dust particles, moisture and other
particlesintheformofpollen,insects,etc.Thesearethe
most common causes of false alarms.
SMOKE ALARM WARRANTY
Thissmokealarmcomeswithalimited3-yearwarranty
against manufacturing defects. (Valid from the date
ofpurchase).Thebatteriesarenotcoveredbythe
warranty.Thewarrantyliabilityislimitedtothevalueofa
corresponding smoke alarm. Defective smoke alarms must
be returned to the dealer together with a description of the
problem. Approved complaints will result in replacement
with a new smoke alarm of the same or a corresponding
type. When submitting a complaint, you must present a
receipt proving the date of purchase.
Manufacturer:
NexaTradingAB,Sverige
TheDeclarationofperformance
(DoP) is published on our website –
www.nexa.se
STATUS RED LED ALARM SIGNAL
Normal mode Flashes once
every 50 seconds None
Replace battery/
low battery
Flashes once
every 50 seconds
Short audio signal
every 50 seconds
Pause mode Flashes once
every 16 seconds None
SOURCE OF ERROR MEASURE
Steam and moisture. False alarms can be triggered if the
smoke alarm is positioned too close to bathrooms or laundry
rooms, or in other places where the ambient humidity is high.
Position the smoke alarm at least 2 metres from bathrooms,
laundry rooms and other places where the ambient humidity
is high.
Dust and dirt.Astheairowsfreelythroughthedetection
chamber, the smoke alarm will attract a fair amount of dust and
pollenparticles.Thiscantriggerfalsealarms.Itcanalsomake
the smoke alarm more sensitive, which can likewise result in
false alarms.
Vacuum clean the smoke alarm regularly – use a plastic
mouthpiece so as not to damage the electronic components.
Make sure not to position the smoke alarm in highly dusty or
dirty places. Place a “cap” over the smoke alarm or remove
it completely if you are carrying out renovation work in your
home.
Draughts, dust and air ows. False alarms can be caused
by positioning the smoke alarm too close to doors, windows,
ventilation systems, fans, air ducts, heat pumps and the like.
Thiscancausedustparticlestowhirlupandintothedetection
chamber.
Do not install smoke alarms in draughty places or close to
windows and doors, ventilation units, fans, air ducts, heat
pumps and the like. Find a more appropriate place for the
smokealarm,fartherawayfromdraughtsandairows.
Temperature variations can cause condensation to form in
the detection chamber. For example, if the smoke alarm is
placed in a room where windows are opened for ventilation in
the winter, close to exits, balcony doors or other places where
the temperature alternates between hot and cold.
Avoid installing smoke alarms in rooms where the
temperature changes rapidly, or close to doors and windows
that are often opened and closed. Move the smoke alarm to
a place witha more even, stable temperature.
Inappropriate placement.Incorrectplacementinanunstable
indoorenvironment,draughts,closetoelectricalunits(EMC)
andlightttingscantriggerfalsealarms.
Position the smoke alarm at least 5 metres from open
cooking ranges, chimneys and other sources of heat.
2 metres from ventilation ducts, heat pumps and air-
conditioningunits.1metrefromlightsanduorescentlights.
CLEANING AND MAINTENANCE
Thesmokealarmshouldbecleanedregularly,atleast
twiceayear.Tocleanyoursmokealarm,vacuumthe
exterior along the opening into the optical chamber to
remove any dust and dirt.
IMPORTANT: Do not attempt to open the cover to clean
the inside of the smoke alarm. Removing the cover will
invalidate the warranty.
RECYCLING
• Theunitprincipallyconsistsofrecyclablematerials.
• Donotdisposeofthepackaging,theunitorthe
contentsofthepackagingashouseholdwaste;follo
w the applicable regulations instead.
• IncompliancewithEUDirective2002/96/CErelating
to waste from electrical and electronic equipment
(WEEE),thisproductmustberecycled.
• Foradditionalinformation,callthedealerorlocal
authority responsible for waste management
Testbutton
Optical chamber
UsingNexaBridgeandtheZSD-109realarm,
you can easily set up an automated system
thatstartswhentherealarmisactivated.For
example, you can have a message sent to your
smartphone, activate sirens or switch on lights
whentherealarmistriggered.
ENGLISH
0905-CPR-210624
NEXA20210010
EN14604:2005/AC:2008
Fire alarm for household use
21