Nira SKINCARE LASER User manual

Quick Start & Instructions For Use
Part number: 820-005, Rev C

2
NIRA SKINCARE LASER QUICK START
Treatment Button
NIRA Star Logo
Power Level Indicator
Power Select Button
Laser Aperture
HOW TO TREAT
1Wash & Dry Face
• Remove all makeup thoroughly.
• Cleanse your skin with your preferred skin cleanser.
• Dry your face completely before beginning
treatment.
2Power On Device & Learn Reject Tone
• Turn on device by pressing the power button.
• Identify the reject tone: While holding the device in front of
you as shown with NO direct contact with the skin, press and
release the treatment button. You will hear a low-pitched beep
that indicatesa rejection pulse.
• The rejection tone indicates that the device tip did not have full
contact with the skin. If you hear this tone during treatment you need to
reposition the device tip making sure there is full skin contact.
Battery Indicator
Charging Port
IMPORTANT: Read all instructions before first use.

3
Treatment
• Using the chosen power level hold the device tip
against the skin starting at the outer corner of your
eye.
• Press and release the treatment button while holding
the device tip in place until you hear a series of
two beeps approximately one second apart
indicating that spot has been successfully
• Press and release the power button to adjust
the power level. Set your NIRA Laser to level 1.
(see below)
• Place the device tip on the skin as shown to the
right. Press and release the treatment button
with your thumb; you will hear a series of 2
beeps. The first beep indicates the laser has
Find Your Ideal Treatment Level
3 4
Illustration of treatment pattern
FOR BEST RESULTS:
Use the device daily according to the instructions for 90 days or more. You may use twice
daily for possible enhanced results. We recommend waiting 1 minute before retreating each
area. Do not treat more than twice within a 1-hour period.
Place aperture flush with skin
12345
Illustration of power levels from low to high
CAUTION: Be sure to move the NIRA to a new spot for each treatment. If you treat
the same spot twice in a row, the heat in your skin may build up to a point where you
feel discomfort or pain. This is not recommended and should be avoided.
• Reposition the device so it is slightly overlapping the previous treatment
spot (See illustration for overlapping pattern) then press and release the
treatment button again.
• Following the 2-3 row pattern shown in the illustration, repeat this
process for 40 pulses on one eye. Once 40 successful pulses have been
completed, you will hear a set of three fast-paced jingle-like tones that
indicate the treatment for that eye is complete.
• Repeat this process for the opposite eye.
• Power down the device by holding down the power button until the NIRA
logo and power level lights turn off. NIRA will also power down after 2
minutes without use.
• Continue with daily skincare regimen.
begun firing. The second beep indicates the laser finished firing for that
one spot.
• Repeat this process and continue to increase the power level until you
have reached a power level where you feel warmth without pain.

4
As we age our bodies naturally stop producing collagen that causes wrinkles and sagging of the skin. The NIRA Skincare
Laser reverses the impact of aging by warming the deeper layers of your skin, activating the skin to produce collagen like it
did decades ago to give you the healthy, beautiful and youthful looking skin that you deserve.
The NIRA Skincare Laser provides lasting results*to reverse the signs of aging in as little as 8 to12 weeks using advanced
dermatologist-tested technology. NIRA holds 11 patents, is FDA cleared and clinically proven to deliver dramatic lasting
results in as little as 2 minutes a day without pain**, redness, skin damage or downtime.
Before using your device for the first time, it is important to read the instructions and safety information in this booklet to
ensure proper use and to achieve your best results. We recommend saving these instructions for future reference.
*based on clinical results with 3-months post-treatment observations
** 86% of users found NIRA to be enjoyable to use. A small percentage of users experienced pain, but found that discomfort lessened with proper use.
Watch the NIRA Instructional Video at:
https://www.niraskin.com/how-to-videos/

5
CONTENTS
HOW TO TREAT ..................................................................................................................................................................................................................................................2
WHO SHOULD USE, WHEN TO USE, WHAT TO EXPECT ...............................................................................................................................................................................6
CHARGING INSTRUCTIONS..............................................................................................................................................................................................................................7
CONNECT YOUR NIRA TO THE iOS APP..........................................................................................................................................................................................................8
TROUBLESHOOTING..........................................................................................................................................................................................................................................9
CLEANING, STORAGE, SERVICE, AND MAINTENANCE..............................................................................................................................................................................10
SAFETY INFORMATION.................................................................................................................................................................................................................................... 11
TRAVEL AND DISPOSAL....................................................................................................................................................................................................................................13
LABELS AND SPECIFICATIONS ........................................................................................................................................................................................................................14
EMC INFORMATION ........................................................................................................................................................................................................................................15
SYMBOLS............................................................................................................................................................................................................................................................19
CONTACT INFORMATION.............................................................................................................................................................................................................................. 20

6
•All skin tones.
•Anyone over the age of 12 with wrinkles around the eyes.
•Anyone over the age of 12 that wants to decrease the appearance of wrinkles around the eyes.
WHO SHOULD USE NIRA
•When the face is fully clean and dried.
•The NIRA laser can be used in the morning or at night.
•Use the NIRA skincare laser daily. For accelerated results repeat twice daily, but do not treat more than twice within a 1-hour period.
WHEN TO USE NIRA
•Always use NIRA on clean and dry skin.
•During your treatment sessions, use the highest power level where you feel warmth without pain.
•Use a facial moisturizer after each treatment. Daily use of a sunscreen with at least SPF 30 is recommended.
•Daily usage is recommended on an ongoing basis to maintain results.
HOW TO ACHIEVE THE BEST RESULTS
•The first treatment session is usually the longest, so it’s best to start when you have more time. After a few treatments, most users are able to complete a full
treatment (40 pulses per eye) in 2 - 3 minutes.
•Immediately after treatment, you may feel a warming sensation similar to how a mild sunburn might feel. This is a normal reaction that will lessen within
an hour following treatment. If you find it uncomfortable, reduce the power levels in subsequent treatments.
•During the first month, you may experience some temporary redness, which is rare. If you treat yourself at night, the redness will diminish while you sleep.
•Some users may notice that their skin becomes rough and/or dry during the first month of use. Apply a moisturizer after treatment to help soothe
dryness.
WHAT TO EXPECT
The NIRA Skincare Laser is an over-the-counter device intended to treat periorbital wrinkles (wrinkles around the eyes).

7
CHARGING INSTRUCTIONS
•First, connect the USB-C cable to the charging port of the device. Next connect the large end of the USB cable to the USB port of your computer, or to the wall
plug adaptor and plug into a wall outlet. Battery indicator lights on the device will start to flash.
•Once the battery is fully charged, the battery indicator lights will stop flashing. It should take no longer than 3 hours to fully charge the device.
•A fully charged device will last approximately 4 hours of continuous use. This equates to several weeks of daily usage between charges. This time will vary with
settings and will lessen as the battery ages.
•Your NIRA Skincare Laser will not work when it is plugged into the battery charger. Unplug your NIRA Skincare Laser to begin treatment.
Accessories:
Micro USB 2.0 Type C Cable, 5V 2A Fixed Blade Wall Plug-in Power Supply
Note: Treatment is disabled during charging.
Charger State Battery Indicators Condition
Charger disconnected
Normal operation—Battery over
half charge
Normal operation—Battery less
than half charge
Very low charge. May stop
functioning.
Charger connected
Still charging. Less than half
charge.
Still charging. More than half
charge.
Charge complete.
Disconnect and treat.
Top is OFF
Bottom is Blinking
Top is Blinking
Bottom is ON
Top is ON
Bottom is ON
Top is OFF
Bottom is Blinking
Top is OFF
Bottom is ON
Top is ON
Bottom is ON

8
DOWNLOAD THE NIRA APP
Our NIRA app is available for iOS only, coming soon to Android.
CONNECTING YOUR NIRA LASER TO THE iOS APP
1. Before connecting, make sure your bluetooth is turned on and
activated on your phone.
2. While the NIRA app is open, turn on your NIRA Laser by
pressing the power button.
3. Simultaneously hold the Power and Treatment buttons for more
than 1 second until the power level lights illuminate from a low
to high, high to low pattern.
4. If requested, enter the number “654321” and click “Pair”, then
wait till you have been directed to the NIRA Customer Portal,
User Registration page.
5. To complete pairing your device, click “New User Registration”
and complete the requested information. Please make sure
to check the small box “I agree with the above Web User
Agreement and Privacy Policy” once you have read the
agreement.
TROUBLESHOOTING: If device does not sync, choose Forget Device within
the phone’s bluetooth menu, and reconnect following the instructions above.

9
Battery Indicators
Other User Action Reference
Code
Bottom Light
blinking SLOWLY
N/A Charge for > 1 hour. If not fixed, call NIRA Customer
Service. 1
Blinking SLOWLY
B-T-B-T N/A Turn off Laser for > 5 minutes for cooling. If not fixed,
call NIRA Customer Service. 2
Blinking FAST
B-TT-B-TT N/A Reboot device. If not fixed, call NIRA Customer Service. 4
Normal Device makes a single monotone sound
that is different from the normal tones Reboot device. If not fixed, call NIRA Customer Service. 5
Blinking SLOWLY
BB-T-BB-T N/A Reboot device. If not fixed, call NIRA Customer Service. 7
Blinking FAST
BB-TT-BB-TT N/A Reboot device. If not fixed, call NIRA Customer Service. 12
Blinking FAST
B-TTT-B-TTT N/A Reboot device. If not fixed, call NIRA Customer Service. 14
Blinking SLOWLY
at the same time N/A Charge for > 2 hours. If not fixed, call NIRA Customer
Service. 8
Blinking FAST
B-TTT-B-TTT N/A Reboot device. If not fixed, call NIRA Customer Service. 9
Blinking FAST
B-TTTT-B-TTTT N/A Press and release treatment button. If not fixed, call
NIRA Customer Service. 11
N/A Device will not power on Charge for >2 hours. Press Power button for 15 seconds,
then release. If not fixed, call NIRA Customer Service. 13
TROUBLESHOOTING
Refer to this table if you are having
problems operating the device. If you
still have questions, please visit www.
niraskin.com or call NIRA Customer
Service at 781-451-1700.
B—Bottom LED
T—Top LED

10
SERVICE AND MAINTENANCE
The device does not require assembly or regular maintenance. Never attempt to service it in any manner. If you have any questions
regarding servicing or maintenance, please call Dermal Photonics Corporation. The NIRA Skincare Laser will operate for more than
one year of recommended use.
CLEANING AND DISINFECTION
The interior of the tip should be cleaned once a week with a cotton swab. Gently place the cotton swab into the opening on the Laser Aperture to clean the glass lens
and remove any debris. If debris has fallen into the laser output window and it will not come out using the cotton swab, gently shake the device to let the debris fall out.
Disinfect all surfaces with 70% alcohol solution between each use.
ENVIRONMENTAL CONDITIONS
The NIRA Skincare Laser should be used in a comfortable environment.
Temperature: 15°C to 35°C (59°F to 95°F)
Relative Humidity: 30-75%
Atmospheric Pressure: 70-106 kPa
REQUIRED SHIPPING AND STORAGE CONDITIONS
The NIRA Skincare Laser should be stored in a dry place at normal room temperature.
Shipping Temperature: –40°C to 50°C (-40°F to 122°F)
Storage Temperature: –20°C to 35°C (-4°F to 95°F)
Relative Humidity: 10-100%
Atmospheric Pressure: 50-106 kPa

11
POTENTIAL SIDE EFFECTS
Side effects that may appear include: skin warmth, redness and stinging. Less frequent side effects that may appear include: dryness, roughness, tanned
appearance to the skin, swelling, flaking, itching, crusting, bruising, pimple-like rash, irritated skin, blistering, scarring, infection, and skin color changes where
your skin may become darker or lighter in color.
SAFETY INFORMATION - PRECAUTIONS
If you have a skin condition or are undergoing professional cosmetic treatments such as injectable toxins (such as Botox) or fillers, please check with your
doctor or clinician prior using the NIRA Skincare Laser. Only use the charger and USB-C cord supplied to recharge the device. Using a different charger or
USB-C cord could cause device malfunction or serious injury. Do not drop the device on hard surfaces as the device could be damaged. The NIRA Skincare
Laser complies with standards regarding electromagnetic fields (EMF). If handled properly and according to the instructions in this booklet, the device is safe
to handle based on scientific evidence available today. Store the NIRA Skincare Laser in the supplied box to prevent lint or dust collection inside the laser
aperture. Lint or dust inside the laser aperture may degrade the performance. Clean the device periodically as instructed. Store the NIRA Skincare Laser in the
supplied box in a secure location away from household animals and children.
SAFETY INFORMATION - WARNINGS
Do not use the NIRA Skincare Laser if the device or the charger is visibly damaged. Never attempt to open or repair the device or charger; doing so could result
in a serious eye or skin injury, or possibly fatal electrical shock. Stop using the device and consult your doctor if you feel pain or your skin gets uncomfortably
hot during treatment. Continued use of the device could result in serious skin injury. Stop using the device if you see unwanted hair growth. Application of
lasers and IPL for hair reduction to the lower face, particularly near the side burns, has been associated with a risk of paradoxical hair growth. This risk is
proposed to arise from low-level heating of the hair follicles.

12
SAFETY INFORMATION - WARNINGS
•To prevent serious injury, you must follow these Instructions for Use when using the NIRA Skincare Laser.
•Changes or modifications not expressly approved by Dermal Photonics Corporation could void the user’s authority to operate the equipment.
•Do not use on skin that is cut, burned, or infected. Only use on skin that is intact.
•Do not use if you are pregnant, nursing or undergoing fertility treatments.
•Do not use if you have a history of skin cancer, or any other type of cancer, or pre-malignant moles.
•If you experience skin color darkening, discontinue use and check with your doctor.
•Do not treat if you have tanned skin. Tanned skin is at an increased risk of adverse effects with light-based devices.
•Avoid sun tanning bed exposures and apply SPF 30 or greater when outside within 6 weeks of treatment.
•The NIRA Skincare Laser is not intended for use by individuals (including children) with reduced physical, sensory, or mental capabilities.
•Children should be supervised to ensure they do not play with the appliance.
•For use only with ages 12 and over.
•Always keep the cord away from heated or wet surfaces to prevent damage to the device.
•Do not point or place the treatment tip over your eye or eyelid; serious or permanent eye damage may result.
•Do not place or drop your device or charger near or into water or liquid.
•Do not use the device while bathing. Doing so could result in serious injury.
•Ensure the skin and treatment tip are dry before treatment. The device may not operate properly if the treatment tip is wet. Such failure to operate properly
may cause serious side effects or device malfunction.
•Do not treat the same spot more than once within a 1 minute period and do not treat more than twice within a 1-hour period. Multiple immediate treatments
may result in discomfort or increased side effects.
•Do not share the NIRA Skincare Laser with other people. Sharing the device could transfer bacteria or other pathogens from one person to another and may
cause harmful infection.
•Use only with the power supply unit and USB-C cable provided.

13
TRAVEL
If traveling with NIRA Skincare Laser, be sure to pack the device in its original packaging to prevent damage. Always check the country’s voltage require-
ments when traveling outside the United States. The device can operate between 100 – 240 VAC and 50 – 60 Hz. You may need a wall plug adapter or
different wall plug blades to charge the NIRA Skincare Laser when traveling abroad.
DISPOSAL
As appropriate disposal of the device at the end of its life is an integral part of our sustainability policy, we ask you to observe the following:
•Do not throw away the device with the normal household waste at the end of its life, but hand it in at an official collection point for recycling.
•This device contains a built-in lithium-ion rechargeable battery that cannot be removed. This rechargeable battery contains substances that may
pollute the environment.
•To ensure proper disposal, take the device to an official collection point or return to Dermal Photonics Corporation. Staff at the collection point or the
Dermal Photonics service center will ensure the battery is removed and disposed of in an environmentally safe way.

14
LABELING AND SPECIFICATIONS
The NIRA Skincare Laser is a Class 1C laser operating at the specifications listed in the table below. The laser aperture integrates a touch sensor requiring skin contact in order to treat.
Specifications
Wavelength 1450nm (+/- 20nm)
Pulse Duration 0.8 s
Maximum Power Output 2.0 W
FCC ID 2ADZENIRC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operations.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer of an experienced radio/TV technician for help.

15
EMC INFORMATION
The NIRA Skincare Laser needs special precautions regarding EMC and needs to be installed according to EMC information. The device contains hardware capable of Bluetooth Low Energy
(BLE) communication. This hardware can receive and transmit RF energy in 2400—2483.5 MHz frequency range with DSSS modulation. It is compliant with CFR Title 47, FCC part 15.249
and ETSI EN 300-400 standards, and equivalent isotropically radiated power is less than 10 dBm (10mW).
Caution: Mobile RF communications equipment can affect the NIRA Skincare Laser device.
Warnings: The use of accessories and cables other than those specified in this document may result in increased emissions or decreased immunity of the NIRA Skincare Laser.
Warnings: The NIRA Skincare Laser should not be used adjacent to or stacked with other equipment treatments.
Electromagnetic Emissions Declaration
The NIRA Skincare Laser is intended for use in the electromagnetic environment specified below. The customer or the user of the NIRA Skincare Laser should assure that it is used in
such an environment.
RF emissions CISPR 11 Group 1 The NIRA Skincare Laser uses RF energy only for its internal function. Therefore, its RF emissions are very low
and are not likely to cause any interference in nearby electronic equipment.
RF emissions CISPR 11 Class B
The NIRA Skincare Laser is suitable for use in all establishments, including domestic establishments and those
directly connected to the public low-voltage power supply network that supplies buildings used for domestic
purposes.
Harmonic emissions IEC 61000-3-2 Complies
Voltage fluctuations/ flicker emissions IEC
61000-3-3 Complies

16
Electromagnetic Immunity Declaration
The NIRA Skincare Laser is intended for use in the electromagnetic environment specified below. The customer or the user of the NIRA Skincare Laser should assure that it is used in such an
environment.
Immunity test IEC 60601test level Compliance level Electromagnetic environment – guidance
Electrostatic discharge (ESD)
IEC 61000-4-2
+8 kV contact
+15 kV air Complies
Electrical fast transient/ burst
IEC 61000-4-4
+2 kV for power supply lines
+1 kV for input/output lines. Complies Mains power quality should be that of a typical home, commercial or
hospital environment.
Surge
IEC 61000-4-5
+1 kV differential mode
+2 kV common mode Complies Mains power quality should be that of a typical home commercial or
hospital environment.
Voltage dips, short interrupts and
voltage variations on power supply
input lines
IEC 61000-4-11
<5 % UT (>95 % dip in UT)
For 0,5 cycle 40 % UT
(60 % dip in UT) for 5 cycles
70 % UT (30 % dip in UT) for 25 cycles
<5 % UT (>95 % dip in UT) for 5 sec
Complies
Power frequency (50/60 Hz)
magnetic field
IEC 61000-4-8
3 A/m Complies
Power frequency magnetic fields should be at levels
characteristic of a typical location in a typical home, commercial or
hospital environment.
NOTE UT is the a.c. mains voltage prior to application of the test level.

17
Electromagnetic Immunity Declaration
The NIRA Skincare Laser is intended for use in the electromagnetic environment specified below. The customer or the user should assure that it is used in such an environment.
Immunity test IEC 60601 test level Compliance level Electromagnetic environment – guidance
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
3 Vrms
150 kHz to 80 MHz
10 V/m
80 MHz to 2.5 GHz
3 V
10 V/m
Portable and mobile RF communications equipment should be used no closer to any part of the NIRA
Skincare Laser including cables, than the recommended separation distance calculated from the equation
applicable to the frequency of the transmitter. Recommended separation distance
d = 1.17 150 kHz to 80 MHz
d = 1.17 80 MHz to 800 MHz
d = 2.33 800 MHz to 2.5 GHz
where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation distance in meters (m).Field strengths from fixed RF
transmitters, as determined by an electromagnetic site survey,
a
should be less than the compliance level in
each frequency range.
b
Interference may occur in the vicinity of equipment marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radio, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted
theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which
the NIRA Skincare Laser is used exceeds the applicable RF compliance level above, the NIRA Skincare Laser should be observed to verify normal operation. If abnormal performance is observed, additional
measures may be necessary, such as reorienting or relocating the NIRA Skincare Laser.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

18
Recommended separation distances between portable and mobile RF communications equipment and the NIRA Skincare Laser
The NIRA Skincare Laser is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the NIRA Skincare
Laser can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the NIRA
Skincare Laser as recommended below, according to the maximum output power of the communications equipment.
Rated maximum output power of transmitter (W)
Separation distance according to frequency of the transmitter (m)
150 kHz to 80 MHz
d = 1.17
80 MHz to 800 MHz
d = 1.17
800 MHz to 2.5 GHz
d = 2.33
0.01 0 .12 0 .12 0.23
0 .1 0.37 0.37 0.74
11.17 1.17 2.33
10 3.70 3.70 7. 37
100 11 . 7 0 11 . 7 0 23.30
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using equation applicable to the fre-
quency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

19
SYMBOLS
The following symbols are used within this manual or on the NIRA Skincare Laser and its packaging:
Consult Instruction For Use Serial Number Class II Double Insulation Electrical Appliance
IP22 Protection against finger-sized objects.
Protected against dripping water. The
device is not submersible. Date of Manufacture Non-ionizing Radiation
Type BF Applied Part Fragile, Handle with Care Use only with NIRA Supply Unit
Temperature Range Keep Dry Read Operator’s Manual
Relative Humidity Range Caution – see Safety Infor-
mation in this document Laser Radiation Warning
Pressure Range Standby & Ready WARNING: Do not use this appliance near bath-
tubs, showers, basins or other vessels containing
water.

Dermal Photonics
100 Corporate Pl, Suite 303
Peabody, MA 01960
Customer Care
781-451-1700
www.niraskin.com
Other manuals for SKINCARE LASER
1
Table of contents
Other Nira Personal Care Product manuals