Njoy UPAC-TEMPHUM-AZ01B User manual

Sensor Box (Temperature & Humidity)
User manual
UPAC-TEMPHUM-AZ01B
Before using this product, carefully read all product documentaon and retain it for future reference.
111.0

2 3
Thank you for purchasing our products!
Please read this manual before using the product.
Focusing on quality at compeve prices, nJoy designs
consumer products for a beer and enjoyable way into
the digital world.
This UPS will protect your electronic equipment from physical
damage and will provide emergency baery backup power to
prevent data loss in the event of power problems.
Table of contents
EN
1. Package contents ................................................................................................... 3
2. Product overview ................................................................................................... 4
3. Product introducon ............................................................................................ 4
4. Funcon diagram ................................................................................................. 5
5. Installaon .............................................................................................................. 5
5-1. Inspecon .................................................................................................... 5
5-2. Pre-installaon ........................................................................................... 6
5-3. Wall-mounng ............................................................................................ 6
5-4. Connect to power .................................................................................... 6
5-5. SNMP connecon .................................................................................... 6
5-6. Operaon ..................................................................................................... 7
6. Monitoring soware operaon ....................................................................... 7
6-1. Soware installaon .............................................................................. 7
6-2. Operaon ................................................................................................... 7
7. Troubleshoong ...................................................................................................... 9
8. Specicaon of environmental monitoring device .................................. 10
9. Input dry contact terminal ................................................................................. 10
Package contents1
Sensor box
Connection cable (3m)
User Manual
NOTE!
If any of the above package content is missing or is damaged please contact the
shop where you have bought the product from.
nJoy UPS models that are compable with this product:
Aten Pro Series
Balder Series
Garun Series
1K / 2K / 3K
1K / 1.5K / 2K / 3K / 6K / 10K
10KL / 15KL / 20KL / 30KL / 40KL / 60KL / 80KL

4 5
Product overview2
1. Communicaon port
2. Input dry contact terminal
3. Device status indicator
4. DC input connector
Product introduction3
This environmental monitoring device (EMD) is a connecvity device to
remote monitor temperature and humidity via SNMP manager. It also
provides two dry contacts to receive signals from up to 2 compable devices
such as security system and alarm system.
• Plug & use for simple installaon with SNMP manager
• Monitor temperature and humidity to protect your precious equipment
• Allow two contact closure signals for user-dened usage
• Management soware to remote monitor temperature and humidity
status via web browser
• Measure temperatures between 0 to 100°C with an accuracy of ±1.5°C
• Measure relave humidity between 10 to 90% RH with an accuracy of ±3%
Function diagram4
Installation5
5-1. Inspecon
Before installaon, please inspect the unit. Be sure that nothing inside the
package is damaged. You will nd following items inside of package.
Cable spec: UL2835 24AWG*4PAIRS+AEB
Plug Type: 4PCC 3U*2PCS
Environmental monitoring device 3m-length of phone cable
AC
Adapter
Humidity
Detection
SNMP
Manager
Dry
Contact
+12VDC
Imput
signal
RS-232
Temperature
Detection
Optional MCU

6 7
5-2. Pre-installaon
Before making connecon to environmental monitor device, make sure the
UPS is already installed with SNMP manager. Please check SNMP manager
for SNMP card installaon.
5-3. Wall-mounng
There is a mounng hole on the back of the unit. Simply mount the unit by
posion the key-hole slot over the mounng screw. (See chart 1)
Chart 1
5-4. Connect to power
Please follow Chart 2 to connect an external 12VDC power source. If
connecng to SNMP card, there is power from SNMP card. It’s no need to
connect an external power source.
NOTE!
To guarantee safety operation, please use the appropriate DC wire with UL2468
#24AWG spec.
Chart 2
5-5. SNMP Connecon
Connect supplied cable from communicaon port of environmental monitor
device to RS-232 port of SNMP manager. Use another network cable to
connect from RJ45 port of SNMP manager to LAN. (Refer to chart 3).
Chart 3
NOTE!
If supplied cable is not long enough for your application, you may substitute another
longer cable (not exceed 15m).
5.6 Operaon
Aer making connecon, status LED will light up and the unit starts to operate.
Monitoring software operation6
6-1. Soware installaon
Aer unit is connected well, please follow below steps to install monitoring
soware from the internet.
1. Go to the website hp://www.power-soware-download.com
2. Click ViewPower Pro soware icon and then choose your required OS to
download the soware.
3. Follow the on-screen instrucons to install the soware.
4. When your computer restarts, the monitoring soware will appear as an
orange plug icon located in the system tray, near the clock.
6-2. Operaon
Step 1: Doubleclick“ViewPowerPro”iconto
launchthesoware.

8 9
Step 2: SNMPmanagerwillbeautomacally
acvated.Select“SNMPmanager”by
clickingrightbuonofthemouse.
Step 3: EnterspecicIPaddresstosearchallSNMPdevicesinLAN.
TheSNMPmanagerwillautomacallycollecttheIPaddress
fromseverbydefaultviaaDHCPserver.
Step 4: AerSNMPmanagerissuccessfully
detectedbySNMPmanager,select
“OpenMonitor”byclickingrightbut-
tonofthemouse.
Step 5: WhenlaunchingViewPowerProsoware,click“Environmental
informaon”icontoviewstatus.
Troubleshooting7
Problem Possible Cause Soluons
It displays 0 in the
environmental in-
formaon secon
of soware.
SNMP card is not con-
nected well.
Make sure SNMP card is
rmly connected in the
UPS.
Network cable or DC
input connecon is not
connected well.
Make sure network cable
is connected well and DC
input connecon is well.
LED is not lighng
or LED is ashing.
Input power is not stable. Check if DC input is
connected rmly. If the
problem persists, please
contact local dealer.
Temperature or
humidity accuracy
is out of range.
Temperature or humidity
sensor is broken.
Please contact local deal-
er directly.

10
Specification of environmental monitoring device8
Model EMD
NominalDCinput 12VDC
DCinputcurrent 0.5Amin.
Temperaturemeasurementrange 0~100°C
Temperaturemeasurementaccuracy ±1.5°C
Humiditymeasurementrange 10%~90%RH
Humiditymeasurementaccuracy ±3%
Communicaon RS232withASCIIprotocol
Acceptablecablelength 15m
Dimension(DxWxH)mm 80×78×28.5
Netweight 68g
Input dry contact terminal9
Input signal specicaon
Inputvoltage Maximum Minimum
12V 5V
'(7(&725,1387
,1387
,1387
Disposal of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European countries with
separate collecon systems)
This symbol on the product or on its packaging indicates that this product shall
not be treated as household waste.
Instead it shall be handed over to the applicable collecon point for the recycling
of electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help prevent potenal
negave consequences for the environment and human health, which could
otherwise be caused by inappropriate waste handling of this product.
The recycling of materials will help to conserve natural resources.

Table of contents