Nomadic NC-X2 Manual

NC-X2Install Manual
16680 N 51st Ave Units 4 & 5
Glendale, AZ 85306
(480) 576-2489
www.NomadicCooling.com/Support
Version 1.2-10102348V | 24V | 12V

NC-X2Instalation Manual Version 1.2-101023 2 Nomadic Cooling Co
TABLE OF CONTENTS
INTRODUCTION ..........................2
ITEMIZED PARTS LIST .....................3
IMPORTANT SAFETY INSTRUCTIONS......5
NC-X2SPECIFICATIONS ...................6
INSTALLATION INSTRUCTIONS............7
ELECTRICAL WIRING DIAGRAMS .........12
WARRANTY INFORMATION ..............14
RETURNS, CANCELLATIONS, and
MISSING PARTS.........................15
INTRODUCTION
The NC-X2Air Conditioner (“AC unit”) is de-
signed and intended for instalation on the
roof of a recreational vehicle during or after
the vehicle is manufactured.
The NC-X2can be installed by one person with
brief help from one additional person. Reading
this instalation manual in its entirety first will
ensure the proper instalation and function of
the NC-X2.
Nomadic Cooling reserves the right to modify
appearance and specifications without notice.
Always bench test AC unit
before installing.
Check to ensure all required
parts are included (see page 3).
@ nomadiccooling
Get social with us!
16680 N 51st Ave Units 4 & 5
Glendale, AZ 85306
(480) 576-2489
www.NomadicCooling.com/Support
Keep a record of the following information:
Model
Serial No.
Date Purchased
Installed By
NC-X2Rooftop AC Unit |
48V
24V
12V

Nomadic Cooling Co 3 NC-X2Instalation Manual Version 1.2-101023
ITEMIZED PARTS LIST

NC-X2Instalation Manual Version 1.2-101023 4 Nomadic Cooling Co
AC Base Plate
AC Unit / Shroud
Foam Gasket
Vehicle Roof
Trim Ring
(optional)
Crossbars

Nomadic Cooling Co 5 NC-X2Instalation Manual Version 1.2-101023
This manual contains safety guidelines and
instructions that can aid in reducing or elim-
inating the risk of accidents and injuries.
A. Recognizing Safety Information
The safety alert symbol is utilized to notify
potential physical injury hazards. To avoid
possible injury or death, follow all safety
messages that come after this symbol.
B. Understanding Signal Words
Signal words identify safety and property
damage messages and indicate the degree
of hazard seriousness.
WARNING is used for hazardous situ-
ations that could result injury (includ-
ing death, severe, moderate or minor
injury if not avoided.
NOTICE is used for situations that
could result in AC unit or vehicle
damage or unnecessary complications
in the instalation process.
HELPFUL TIP is used for useful
information or best practices.
C. Supplemental Directives
To avoid potential injury and even death,
read and follow all of the safety information
and instructions.
Read and comprehend these instructions
before installing, using, servicing, or maintain-
ing this AC unit. Poor instalation, operation,
servicing, or maintenance of this AC unit can
result in severe injury. Follow all instructions.
The instalation must comply with all appli-
cable local and national codes, including the
atest edition of the following standards:
USA
• ANSI/NFPA70, National Electrical
Code (NEC)
• ANSI/NFPA1192, Recreational
Vehicle Code
CANADA
• CSA C22 1. Parts I & II,
Canadian Electrical Code
• CSA Z240 RV Series,
Recreational Vehicles
D. General Safety Messages
WARNING - Failure to follow the subsequent
warnings could lead to death or serious injury.
• A qualified service technician MUST
install or service this product.
• Do NOT modify this product in any
way. Modifications can be extremely
dangerous and void any warranties.
• Do NOT add any devices or accessories
to the AC unit unless specifically
authorized in writing by Nomadic
Cooling Co.
IMPORTANT SAFETY INSTRUCTIONS

NC-X2Instalation Manual Version 1.2-101023 6 Nomadic Cooling Co
NC-X2SPECIFICATIONS

Nomadic Cooling Co 7 NC-X2Instalation Manual Version 1.2-101023
INSTALLATION STEPS
1. Mark your 14”x 14” rooftop opening using
the cardboard tempate. Cut from the
exterior of your vehicle.
Never cover AC top fan.
When determining AC unit location,
be sure to allow for the hood/cover
when positioned on the roof.
Make sure there is no electrical or
other encumbrances in the way.
Do not cut into structural beams.
2. Make sure the panned opening is
centered from all four sides. This gives
the best chance for easy instalation.
Use painter’s tape and a permanent
marker to draw your 14”x 14” cutline.
Make multiple passes with the marker.
If you make a mistake repace the
tape and try again. Measure repeat-
edly to make sure your lines create a
perfect 14”x 14” square.
3. Drill each corner of your markings
through the roof. This will make it easier
to detect the location of your 14”x 14”
opening from the underside of your roof.
Use a 1/8” drill bit for corner holes.
4. Cut on your lines using a jig saw, nibbler
or cutting wheel.
Use a sander or file to smooth out the
rough edges after cutting.
14”
14”
14”14”
Exterior Roof
Vehicle Front
Exterior Roof
14”
14”
14”14”
Exterior Roof

NC-X2Instalation Manual Version 1.2-101023 8 Nomadic Cooling Co
5. Paint around the edges of the cut roof
opening to prevent rust. You can use any
color rust-preventative paint.
6. Remove tape and clean surface.
7. Remove waterproof gasket from box.
Make sure area/paint is clean, dry and
clear of all debris.
Use alcohol wipes or PrepSol to
remove oil or wax from vehicle roof.
If pacing gasket over a high or uneven
roof surface, remove small amounts of the
14”x 14” gasket to match roof contours.
Use bade to cut away gasket
if needed.
Remove gasket adhesive only after
making any necessary cuts. Pace the
gasket sticky side down.
8. Apply polyurethane adhesive seaant
(included) around 14”x 14” gasket, after
sticking gasket down on vehicle roof.
9. Pace AC unit on roof over 14”x 14” gasket
gently. Measure side-to-side until unit is
centered on all four sides.
Be careful not to puncture, rip
or tear the gasket with AC unit’s
mounting bolts.
Do not put adhesive on top of gasket.
Do not damage electrical components
when pacing AC unit.
10. Adhere optional leveling strip behind the
14”x14” gasket.
Exterior Roof
Exterior Roof
URETHANE ADHESIVE
CUTAWAYS FOR ROOF RIDGES
L
eveling strip
14” x 14” gasket
Adhesive side

Nomadic Cooling Co 9 NC-X2Instalation Manual Version 1.2-101023
11. From inside the vehicle add crossbars
with mounting bolts to attach AC unit to
the roof.
Do not use electric drill on crossbars.
12. Use of the trim ring is optional. You may
find the trim ring useful if the AC unit is cen-
tered between the front and rear of vehicle,
where the rooftop may be less supportive.
13. Add a washer and lock washer to each
of the four bolts that screw into the AC unit
base pate.
If NOT using Trim Ring, you can add
the optional pastic sleeves to the two
rear bolts, between the crossbars and
the AC unit base.
During the instalation process, if the
locking nut is installed too tightly, it
may cause deformation of the AC unit
base pate. The sleeve can pay a limit-
ing role, with any excess locking force
acting on the sleeve instead of the
AC unit base pate. The length of the
sleeve is determined by the thickness
of the vehicle’s roof and may need to
be trimmed.
Finger tighten the bolts into the AC unit’s
base pate until they stop. Next, tighten all
four nuts to the crossbar to 3.7 lbs. of torque
(5 newton meters).
A sticker found on the bag
of bolts may say to tighten
to 5.0 lbs. of torque, please
disregard and use the rec-
ommended 3.7 lbs.
AC unit will help to create pressure.
When securing AC unit to the vehicle,
increased compression of the gasket
will level the unit against the roof. No
light should be visible.
Do not over-tighten mounting bolts.
Bolts will rotate if over-torqued,
and may break from AC base pate.
Over-tightening will void warranty.
Vehicle
Ceiling
Front
Rear
Crossbar
Washer
Lock Washer
Nut (fat side up) Finger tighten all 4
bolts then tighten nuts
to 3.7lb torque (~5nm).
Bolt
Pastic Sleeve
(optional if not
using Trim Ring)
Vehicle Roof (cutout)
Gasket
Trim Ring (Optional)
AC Base Pate
Back of AC unit
Instalation WITHOUT Trim Ring
Instalation WITH Trim Ring
FrontRear
Trim Ring
Vehicle
Ceiling
Gasket
Crossbar
Crossbar
Optional
Sleeve
Gasket

NC-X2Instalation Manual Version 1.2-101023 10 Nomadic Cooling Co
Our gaskets are used for vibration
absorption. It is very high density and
can’t be compressed more than 10%.
Use gasket tension to control AC unit’s
distance from roof surface.
AC unit should be resting on foam gasket
and not on the vehicle’s roof.
Over compression of the unit to the
roof may cause the internal fan to rub
against the fan housing.
Be sure the fan bades rotate freely
prior to starting the unit.
12. Install and connect LCD control panel
before connecting to power to avoid
blowing internal fuse.
An appropriately-sized fuse must be
paced between your power source
and the AC unit:
48V = 30A fuse
24V = 50A fuse
12V = 70A fuse
13. Connect DC power wires to unit. “Quick
Connection to DC Wiring Harness” included.
12V systems use an Anderson connector,
24V and 48V systems use a simiar Ander-
son style connector.
Make sure wiring is appropriately
sized and is no smaller than 4AWG.
14. Attach LCD control panel and AC
wiring harnesses.
15. Attach thermostat wires to control panel
wiring harness.
Details of control panel connections are
shown in electrical diagram on page 12.
Condenser is always to the left of the
back wire. Be careful not to break
these wires.
16. Use the foam separator to properly sepa-
rate hot air from cold air as it enters and
exits the AC unit.
AC unit centered
on foam gasket
Foam separator
AIR IN AIR OUT
To AIR-OUT sensor
To Control Panel

Nomadic Cooling Co 11 NC-X2Instalation Manual Version 1.2-101023
17. Use heat resistant tape to secure the air
separator in pace. Use your best judg-
ment on how much tape to use and
where to adhere it, as every instalation is
different. The tape helps the air separator
keep the warm and cool air separated.
18. Test all connections between the
power source and the unit for excessive
heat during normal operations.
19. Install facepate. Line up the facepate
vents with the air-out fan openings in the
AC base pate. Use the 8 screws to secure
the facepate to the ceiling of your ve-
hicle. The DIY kit screws do not require
drilling into the ceiling, regardless of
finish or material (wood or metal).
The facepate does not screw into the
AC unit base. It attaches (flush mount-
ed) to the vehicle’s ceiling directly.
Congratulations!
Your Nomadic Cooling X2AC unit rooftop
instalation is complete. Now...
Exploded NC-X2Components
Vehicle Ceiling

NC-X2Instalation Manual Version 1.2-101023 12 Nomadic Cooling Co
X2 Electrical Schematic Coming ASAP

Nomadic Cooling Co 13 NC-X2Instalation Manual Version 1.2-101023
Shown below is a properly wired LED Control Panel for X2 (12V and 24V) models.
Red
Red White
Back Green
2 Back
To Inlet
Thermistor
Back and
Back/White
Striped
24V | 12V
Yellow Blue

NC-X2Instalation Manual Version 1.2-101023 14 Nomadic Cooling Co
Nomadic Cooling is dedicated to delivering
top-quality products and outstanding cus-
tomer service. We provide an industry-leading
warranty for our products to ensure your sat-
isfaction and peace of mind. Please carefully
review the following warranty policy.
1. Warranty Duration:
All X2units are covered by a two-year
warranty starting from the date of purchase.
2. First-Year Coverage:
During the first year of the warranty period,
Nomadic Cooling will cover the cost of ship-
ping and exchanges for any valid warranty
caims. If your X2unit experiences any defects
due to manufacturing or workmanship issues
within the first year, we will promptly arrange
for shipping and provide a repacement unit
at no additional cost to you.
3. Second-Year Coverage:
In the second year of the warranty period,
the customer will be responsible for shipping
the X2unit to Nomadic Cooling for inspection
and repair. If a defect covered by the war-
ranty is found, Nomadic Cooling will repair
or repace the unit at no cost. However, the
customer will be responsible for the shipping
expenses associated with returning the unit to
Nomadic Cooling for repair or repacement.
4. Core Charge:
If the customer wishes to have a repace-
ment unit shipped prior to Nomadic Cooling
receiving their old unit, a core charge of up
to 50% of the Manufacturer’s Suggested Re-
tail Price (MSRP) may apply. This core charge
is intended to ensure the return of the old
unit to Nomadic Cooling. The core charge will
be added to the purchase price of the re-
pacement unit and will be refundable upon
Nomadic Cooling’s receipt and evaluation of
the returned unit. If the warranty department
determines that the defect was due to No-
madic Cooling’s fault, the core charge will be
refunded in full.
5. Exclusions and Limitations:
The following conditions are not covered by
the warranty:
• Damage caused by misuse, negligence,
accidents, or unauthorized modifica-
tions.
• Damage resulting from improper instal-
ation, maintenance, or storage.
• Damage caused by natural disasters,
fire, water, or any other external factors
beyond our control.
• Normal wear and tear, cosmetic damag-
es, or minor imperfections that do not
affect the functionality of the product.
6. Labor Exclusion:
Nomadic Cooling’s warranty policy does
not cover any abor costs associated with the
inspection, repair, or repacement of the X2
unit. Any additional expenses reated to abor,
including but not limited to instalation, re-
moval, or troubleshooting, are the sole re-
sponsibility of the customer.
7. Warranty Caim Process:
To initiate a warranty caim, please contact
Nomadic Cooling’s customer support team
through the provided channels on our web-
site (www.nomadiccooling.com). Our repre-
sentatives will guide you through the neces-
sary steps and provide instructions on how to
proceed with the warranty caim.
Please note that this warranty policy is sub-
ject to the terms and conditions stated herein
and may be subject to change without prior
notice. Nomadic Cooling reserves the right to
determine the validity of all warranty caims
and to make the final decision regarding re-
pairs, repacements, or refunds.
For further information or any inquiries
regarding our warranty policy, please refer
to our website or contact our customer
support team.
WARRANTY POLICY

Nomadic Cooling Co 15 NC-X2Instalation Manual Version 1.2-101023
Returns
Nomadic Cooling will gadly accept returns
within 30 days of receiving the order. Only
items in their original condition with all pack-
aging, accessories, instruction manuals, war-
ranty cards, and UPC codes will be accepted.
Any returns after 30 days are subject to ap-
proval. Please speak with a Nomadic Cooling
employee regarding your return. This can be
done through email or by calling Nomadic
Cooling at (480) 576-2489.
There is a 15% restocking fee for all return
orders. Customers are responsible for the
return shipping of any product to Nomadic
Cooling. Return shipping can be arranged for
you by Nomadic Cooling or can be arranged
on your own but must include a tracking
number. If the product arrives back to No-
madic Cooling damage due to mishandling,
poor packaging, or in otherwise unusable con-
dition for resale then an additional fee may
be assessed.
Products to be returned should be sent to:
Nomadic Cooling Co
16680 N 51st Ave Unit 4-5
Glendale, AZ 85306
Due to some products being shipped direct-
ly from the manufacturer, please check with a
Nomadic Cooling employee where to send all
other returns.
Returned products will be assessed for dam-
age upon receiving at Nomadic Cooling.
Refunds will not be processed until the
product is received, inspected, and/or test-
ed at Nomadic Cooling HQ. All refunds will
be processed back to the original payment
method and/or store credit in the form of a
gift card.
Order Cancelations
If you wish to cancel your order for any rea-
son, please let a Nomadic Cooling employee
know as soon as possible. This can be done
through email or by calling Nomadic Cooling.
If you are canceling before the order has
been fulfilled and/or shipped then we will
process a refund back to the original payment
method. If you are wishing to cancel and the
order has already been fulfilled then the
cancelation will be processed as a return and
is subject to a restocking fee. Please see the
returns section for more information. If ap-
plicable, the customer is responsible for any
“stop and return” fees.
Missing Items
Upon receiving your order from Nomadic
Cooling please immediately open the package
and inspect the contents to ensure all items
from the order were included. If you suspect
that an item is missing or the incorrect item
was sent please notify a Nomadic Cooling em-
ployee ASAP so we can assess the order. If you
fail to notify a Nomadic Cooling employee
within 14 days of receiving your order that an
item was missing or incorrect then the cus-
tomer will be responsible for all new shipping
costs for the missing or incorrect item(s).
To better prevent orders with missing or
duplicate items, and for ease of tracking,
Nomadic Cooling will only be shipping orders
once all items in the order are ready for ship-
ping. Nomadic Cooling will not send partial
shipments. Exceptions may occur when spe-
cifically requested by the customer and/or
item(s) in the order are on backorder. Prod-
ucts will be shipped the same when ready
unless requested held by the customer.
RETURNS, CANCELLATIONS AND MISSING ITEMS
Other manuals for NC-X2
1
This manual suits for next models
1
Table of contents
Other Nomadic Automobile Accessories manuals
Popular Automobile Accessories manuals by other brands

Axxess
Axxess AX-VL90032 installation instructions

Car-Interface
Car-Interface c.LOGiC CI-C2-MK-CD manual

JBA
JBA 1961S-3 installation instructions

Virtual Reality
Virtual Reality Hands-Free Car Kit VRBT300V product manual

Go Rhino
Go Rhino 390325 installation instructions

NavLinkz
NavLinkz RL4-UCON8-LV manual