Nora Bode OXYJET GO User manual

NORA BODE OXYJET GO
Cosmetic skin treatment device for home use
type number: GOV01042019
MANUFACTURER:
NORA BODE™Kosmetik | Jutta & Lothar Bode GbR
1. edition 06/2019
Copying, whether in full or in part, requires the prior written permission
of NORA BODE Kosmetik. Printed in Germany.
NORA BODE™and OXYJET GO™are registered trademarks of Jutta & Lothar Bode GbR.
OPERATING MANUAL
1

DEAR CUSTOMER,
thank you for choosing the NORA BODE OXYJET GO device.
The OXYJET System is a hightech oxygen treatment for your beauty needs. For over 20 years, NORA BODE Kosmetik have
specialised in the needle free oxygen pressure injection and are the original inventors and patent holders of this method.
In cosmetic and medical practices worldwide, the Bode OXYJET is the method of choice when it comes to gentle but effective
treatment of skin problems, especially wrinkles, pigment irregularities and loss of elasticity.
NORA BODE now introduces another unique innovation into the World of Beauty, which means you can supply your skin with
concentrated active ingredients and molecular encapsulated oxygen at home or wherever you please; smoothing out wrinkles
and revitalizing your skin – gentle, effective and safe!
With pulsed pressure special cosmetic formulations are introduced into the skin without needles. Due to the pulsed pressure,
which is xed in its intensity, the active ingredients make their way through the natural intercellular spaces to the deeper
layers of the skin where they can form an active deposit. The German DERMATEST Institute, Münster, has conrmed the strong
penetration-accelerating effect. For more information on this and the OXYJET concept, see the attached device brochure.
Traditionally, ”Made in Germany“ and NORA BODE Kosmetik manufacturing assures all of our customers of the outstanding
quality of all our products. The new OXYJET GO system was developed and manufactured in Germany – producing you a high
quality and exclusive product.
Should you have any questions, please do not hesitate to contact us!
We wish you every success with your OXYJET GO device!
NORA BODE KOSMETIK
Table of contents 1. Introduction
1. Introduction page 3
2. Safety instructions page 4
3. Intended use page 7
4. Scope of delivery and device overview page 8
5. Preparation for commissioning page 10
6. Device functions and operation page 14
7. The OXYJET GO treatment page 16
8. Cleansing and storage page 22
9. Order accessories page 23
10. Warranty and support page 23
11. Trouble shooting page 24
12. Disposal page 26
13. Technical data page 26
14. CE-conformity and electromagnetic compatibility page 26
Please take the time to read this operating manual carefully. Keep it for later use and make it
accessible to other users. Please pay special attention to the safety instructions in chapter 2.
2 3

The following sections contain important information about the correct use of your OXYJET GO device and its parts and how to avoid
any danger. Please read and pay attention to all the instructions every time before the application of your device and the enclosed
treatment preparations.
The following symbols are used in the operating manual and on the packaging:
2. Safety instructions
Warning on risk of severe injury or danger to health
which could lead to death.
Warning on risk of injury or dangers to health.
Safety information on possible damage to the device.
Reference to important information.
The device must not be used near water or in the water
(e.g. sink, shower, bath or other vessels containing water).
Device of protection class III: The device must only be supplied with a safety
extra-low voltage (SELV) according to the marking on the device.
Polarity symbol: Polarity of DC device input socket and DC power
adapter connector must match: Power plug tip positive (center positive),
cylinder negative.
Disposal according to Waste Electrical and Electronic Equipment EC Directive
WEEE (Waste Electrical and Electronic Equipment).
CE-Conformity: This product complies with the requirements of the applicable
European directives.
Danger of Electric shock!
The OXYJET GO device and the power adapter may not get wet. Do not use the
device in wet surroundings, e.g. near a lled sink, a lled bath, a running shower
or near a lled swimming pool or any other liquid-lled container.
Do not use the device and/or the power adapter if there are signs
of damage or access to active internal parts, eg due to damage. Contact your
dealer/customer service.
Make sure that children do not play with the device.
Keep it out of the reach of children.
The cleaning and maintenance of the device should not be performed
by children.
Never make any structural changes to the device or the power adapter.
This device is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
The device is not intended for use by persons younger than 18 years.
Do not use the device, if you have skin infections, open wounds, rashes, burns,
sunburn, inammation, eczema, psoriasis, rosacea, teleangiectasia (couperose
or spider veins), active infections like herpes or active acne breakouts in the
areas to be treated.
Do not use the device, if you have large moles, tattoos, port wine stains,
permanent make-up or any skin irritation in the areas to be treated.
Do not use the device, if your skin is still recovering from another cosmetic-medical
treatment like chemical or mechanical peeling, laser resurfacing, fractional
laser treatment, dermal ller injections or any other irritating skin treatment.
Do not use the device, if you have skin cancer and unclear skin irregularities.
If in doubt consult your doctor before using the device.
DANGER
DANGER
WARNING
WARNING
ATTENTION
NOTE
4 5

Do not use the NORA BODE treatment products and the device, if you suffer
from allergic reactions towards special cosmetic ingredients contained in
the products. For more details on the ingredients of the enclosed treatment
preparations, please refer to the respective outer packaging. If you are not
sure if you can use the products, please consult your doctor.
Only use the enclosed NORA BODE treatment preparations together with the
device.
Use only the supplied original power adapter for power supply to prevent
damage to the device.
The device must only be supplied with a safety extra-low voltage (SELV)
according to the marking on the device.
If the power adapter is defective or damaged, it may only be replaced by
an original spare part. Contact your dealer/customer service.
The OXYJET GO device has been developed to address the rst signs of facial ageing. It is only suitable for the treatment of healthy
skin.
The OXYJET GO device is designed for facial use only. Never use the device in other areas of the body. Do not use on body openings.
For hygienic reasons the device should only be used by one person. Use the device only in the manner described in this manual and
observe the safety instructions.
The device is not intended for use by persons younger than 18 years.
Make sure that children do not play with the device. Keep it out of the reach of children.
Never make any structural changes to your device.
The OXYJET GO device and the power adapter may not get wet. Do not use the device in wet surroundings, e.g. near a lled sink,
a lled bath, a running shower or near a lled swimming pool. The device and mains adapter must never get wet.
The OXYJET GO device has been developed for a maximum of 20 minutes of treatment, and if the device reaches the maximum
treatment time it switches off automatically. Additionally it has an internal temperature switch to protect against overheating.
If the device becomes too hot due to overload or external inuences, it switches off automatically. In this case disconnect the
device from the mains and allow it to cool down for at least 2 hours.
The OXYJET GO device has been developed exclusively for private use and not for professional use in cosmetic and medical practice
or any other business purpose.
3. Intended use
ATTENTION
6 7

Scope of delivery:
1 OXYJET GO device
1 Storage station
1 Power adapter incl. AC adapter (EU, CN, AU, UK, US)
1 NORA BODE OXYJET 1 Serum 15 ml
1 NORA BODE OXYJET 2 Serum 15 ml
1 Operating manual
1 Device brochure
Please check carefully whether the components included in the delivery are complete and undamaged (possible transport damage).
If something is missing and/damaged, please contact your OXYJET GO dealer or NORA BODE Kosmetik:
NORA BODE Kosmetik
Glockengasse 8
D-65329 Hohenstein, Germany
T.: +49 (0)6120 6484
E-Mail: info@norabode.com
4. Scope of delivery and device overview
1
2
3
4
5
6
7
1
2
3 4
Device overview:
1. Nozzle
2. ON/OFF button
3. Pulse button
4. Flow button
5. LED light ring
6. Device input socket
7. Storage station
8 9

5. Preparation for commissioning
Danger of Electric Shock!
If the unit and/or power adapter and/or AC adapter become wet,
there is a risk of electric shock.
Always inspect the device and the power adapter before use. Do not use the
device and/or the power adapter if you notice any damage. Do not touch
internal components if the unit is damaged to avoid electric shock. Contact
your supplier or an authorized NORA BODE service center.
Do not make structural changes to your device.
Do not use the device near wet environments such as bathtubs, sinks,
showers or other containers lled with water or other liquids.
Clean the device and the power adapter only with a damp cloth.
Never rinse under water!
Always keep the OXYJET GO device and the power adapter incl. its AC
adapters dry!
Take your OXYJET GO device, storage unit, both preparations
NORA BODE OXYJET 1 and 2 serum and the power adapter
out of the packaging. Put the device into its storage station as
shown below.
DANGER
Place the treatment products NORA BODE OXYJET 1 and 2
serum to your treatment place. Detailed informations on
the two treatment preparations can be found in the enclosed
device brochure.
10 11

You will nd a total of 5 AC adapters (EU, CN, AU, UK, US) in the outer
packaging of the power adapter that allow you to use the OXYJET GO
device in many countries around the world.
Danger of Electric Shock!
Keep the AC adapters, as well as the power adapter, de-energized before
complete assembly!
Always disconnect the power adapter from the mains before replacing or
removing the AC adapter! It is essential to observe all instructions in the
enclosed data sheet of the power adapter unit.
1. First select the appropriate AC adapter for your country
(for example, the Euro adapter for use in Germany).
2. Slide the appropriate AC adapter onto the power adapter
from above until it snaps into place. Pay attention to the
correct and tight t of the adapter.
3. To change the AC adapter, press ”PUSH“ on the power
adapter and pull the AC adapter upwards.
„click“
Now place the device back into the storage station, and then
plug the power adapter into a socket.
The ”ON/OFF“ button now lights up red in the control panel
as soon as it is ready for operation.
To disconnect the device from the power supply, always unplug
the power adapter from the socket before removing the DC plug
from the DC device socket.
DANGER
NOTE Take the OXYJET GO device out of its storage station and
connect the DC plug of the power adapter to the DC device
socket on the bottom of the device. Make sure the plug is
correctly seated in the appliance socket.
12 13

6. Device functions and operation
Before you perform a facial treatment, you should familiarize
yourself with the use and operation of the OXYJET GO device.
1. Pulse - Function: Infusion of OXYJET 1 and OXYJET 2
serum by use of pulsed pressure.
2. Flow - Function: Decongestant massage in the eye
area.
ON/OFF button:
As soon as you connect your OXYJET GO device to the power
adapter and plug it into the socket, the ”ON/OFF“ button lights
up in red as soon as it is ready for operation. The device is now
in STAND BY MODE. As soon as you press the ”ON/OFF“ button,
the device switches to the SELECT MODE. The ”Pulse“ and
”Flow“ buttons as well as the LED light ring in the device head
light up blue – the device is ready for operation. Press the ”ON/
OFF“ button again to switch off the device.
PULSE button:
Use the ”Pulse“ button to activate the pulsed pressure function.
Your OXYJET GO device will conrm the activation of this feature
by the slowly ashing ”Pulse“ button. To exit the function, please
press the button again. The unit returns to SELECT MODE.
FLOW button:
Use the ”Flow“ button to activate the constant ow function.
Your OXYJET GO device will conrm the activation of this feature
by the slowly ashing ”Flow“ button. To exit the function, please
press the button again. The unit returns to SELECT MODE.
LED light ring:
The light ring in the device head indicates the current operating
status of your OXYJET GO device. In SELECT MODE and during
treatment, the light ring illuminates constantly blue.
The OXYJET GO device is designed for a maximum operating
time of 20 minutes, which is completely sufcient for the
treatment of all facial areas described. As soon as the end of
the maximum operating time of 20 minutes approaches, the
LED light ring changes color from blue to red, and warning
sounds are emitted.
Please switch off your device now, disconnect it from
the mains and let it cool down for at least 1 hour.
Immediately before reaching the forced shutdown (maximum
operating time of 20 minutes has been reached), the light ring
ashes red and further warning sounds are emitted. Afterwards,
the device shuts off automatically to prevent overheating.
The device cannot be switched on now. The LED ring ashes
red at short intervals when the ”ON/OFF“ button is pressed.
In addition, warning sounds are emitted.
Disconnect your OXYJET GO unit from the mains and
allow it to cool down for at least 1 hour before putting
it back into service.
The OXYJET GO device also has an internal temperature switch
to prevent overheating. If the device becomes too hot due
to overload or external inuences, it switches off automatically.
The illuminated ring now lights up permanently red and
switching on the device is prevented.
Disconnect your OXYJET GO unit from the mains and
allow it to cool down for at least 2 hours before putting
it back into service.
NOTE
NOTE
NOTE
14 15

7. The OXYJET GO treatment
7.1. To practise: 7.2. The face treatment „step by step“:Before you perform a facial treatment, you should familiarize
yourself with the use and operation of the OXYJET GO device.
The inside of your forearm is well suited to practice handling
your device.
For preparation of the treatment cleanse your face with a
mild syndet, cleansing gel, foam or milk as usual. Dry your
skin carefully afterwards.
Then split your face into the following treatment areas:
Eye area
Mouth and lip area
Forehead
1. Turn on the device by pressing the ”ON /OFF“ button. The
”Pulse“ button and the ”Flow“ button now light up blue,
and the LED light ring in the device head is illuminated in
blue. The device is now in SELECT MODE.
2. „Pulse“ function: Take the device out of the storage station
and apply the nozzle to the skin of your inner forearm with
gentle pressure. Press the ”Pulse“ button. Now the light of the
”Flow“ button will turn off and the ”Pulse“ button light starts
to blink. Stay on the same skin area for approx. 3 pressure
surges. Now slide on with the nozzle for approx. 1 cm and
stay on the same skin area again for approx. 3 pressure
surges. Proceed in this way so that you treat a skin area
completely. Apply gentle pressure to the skin and slowly slide
over the skin without completely sealing the nozzle. You use
the device properly if you feel a gentle ”clapping“ on your
skin. Now press the ”Pulse“ button again and the device will
stop the pulsation.
3. „Flow“ function: Press the ”Flow“ button. Now the light of
the ”Pulse“ button will turn off and the ”Flow“ button light
starts to blink. Slide slowly and gently with short strokes
across the skin on the inside of your forearm. Just place the
nozzle very lightly and work without pressure.
Now press the ”Flow“ button again and the device will stop
the ow.
forehead
eye area
eye area
mouth and lip area
16 17

Now start with the treatment:
Take 4 to 5 drops of the OXYJET 1 serum, spread it thoroughly
over your complete face. The OXYJET 1 serum forms the basis of
every facial treatment.
The treatment of the eye area:
1. Spread 1–2 drops of the OXYJET 2 serum below the eye in the
cheekbone area and temple.
Keep a sufcient distance away from the eye.
2. Tighten the skin area to be treated between the fore and middle
ngers and apply the OXYJET GO nozzle with gentle pressure.
Press the ”Pulse“ button and start to work from the inner corner of
the eye, proceeding step by step to the temple. Stay on the same
skin area for about 3 pressure surges and continue to slide slowly
until you have treated your entire lower eye area.
When done, press the ”Pulse“ button again, and the unit will stop
the pulsation.
Put your device back in the storage station. Now repeat the whole
process – apply the product and pulse it in with your other eye.
3. Spread 1–2 drops of the OXYJET GO 2 serum above your eyebrow,
but not on the moving part of your upper eyelid. You should also
keep at least 2 cm distance to the eye and treat only the region
above the eye, which is bony backed. Work from the center of
the face to the outside. Stay on the same skin area for about 3
pressure surges and continue to slide slowly until you have
treated your entire upper eye area.
When done, press the ”Pulse“ button again, and the unit will stop
pulsation. Put your device back in the storage station.
Now repeat the whole process – apply the product and pulse it in
with your other eye.
4. Swelling in the lower eye area:
Apply 1–2 more drops of OXYJET 2 serum below the eye.
Distribute the product carefully and be sure to observe the mi-
nimum distance of 2 cm to the eye. Press the ”Flow“ button and
glide gently and slowly from the bridge of the nose outwards to
the temple and in front of the ear down to the chin line. Repeat
this 3–4 times very gently. Press the ”Flow“ button again, and the
unit will stop.
Put your device back in the storage station and repeat the whole
process on your other eye.
Possible irritation of the eye mucosa!
When applying the OXYJET 1 and OXYJET 2 sera,
keep a sufcient distance from the eye (approx.
1 cm) to avoid contact of the preparations with
the eye mucosa. If the preparations accidentally
get into the eye, rinse with plenty of water!
During the OXYJET GO treatment keep the device
away from the eye in the "Pulse" and "Flow"
modes (approximately 2 cm) to avoid irritation from
escaping pressure.
WARNING
18 19

The treatment of the mouth area:
1. Spread 1–2 drops of the OXYJET 2 serum on the upper lip and over
the lip contour. Proceed by treating one half of the upper lip rst,
treating the other half second.
2. Apply the OXYJET GO nozzle to the lip area to be treated with
gentle pressure and press the ”Pulse“ button. Stay on the same
area of skin for about 3 pressure surges and continue to slide
slowly until you have treated your entire upper mouth.
When done, press the ”Pulse“ button again, and the unit will stop
pulsation. Put your device back in the storage station.
Now repeat the whole procedure – apply the product and pulse it
in on the other side of the upper part of the mouth.
3. Now distribute 1–2 drops of OXYJET 2 serum below the lower lip,
and on the edge of the lip as well. Proceed by treating one half
of the lower lip region rst, then the other half in a second step.
Proceed as described in point 2 and treat both sides of the lower
lip region.
4. If you want to specically treat your nasolabial fold, apply 1 drop
of the OXYJET 2 serum to the area to be treated and proceed as
described in point 2.
The treatment of the forehead:
1. Split your forehead in half and spread 1–2 drops of the OXYJET 2
serum on one side.
2. Now apply the OXYJET GO nozzle with gentle pressure on the
forehead above the eyebrow and press the ”Pulse“ button. Work
in lanes from the nasal root out to the hairline. Stay on the same
area of skin for about 3 pressure surges and continue to glide
slowly, lane by lane, until you have treated your entire forehead.
When done, press the ”Pulse“ button again, and the unit will stop
pulsation. Put your device back in the storage station. Now
repeat the whole process – apply product and infuse – on the other
side of the forehead.
7.3. How often you should use the OXYJET GO device
For best results, use the device as follows:
1. For 4 weeks, 3 times a week, preferably in the evening. There should always be at least one treatment-free day between
treatments.
2. Then you should use the device once a week.
For an instant effect, if you want to look fresher for a special occasion, you can use the device at any time in between.
7.4. The nal care of your skin
After nishing treatment with your OXYJET GO device, you should provide your skin with your daily day/night care. In addition,
you should use the serums OXYJET 1 and 2 in the evening under your usual care.
20 21

8. Cleansing and storage
Danger of Electric Shock!
If the unit and/or power adapter and/or AC adapter become wet, there is a
risk of electric shock.
Never immerse the device or power adapter in water or rinse it under running
water.
The cleaning and maintenance of the device should not be performed by
children.
Always keep the device out of the reach of children!
Do not use aggressive detergents or alcohol.
Do not place or store your OXYJET GO device in a location where it may fall or
be pushed or dropped into a bathtub/washbasin or other container lled with
water!
Always disconnect the power adapter and the device from the wall socket
when not in use.
Always disconnect your OXYJET GO device from the mains rst before cleaning
it. Disconnect the power adapter from the wall socket and then remove the DC
plug of the power adapter from the DC device socket of the OXYJET GO device.
Clean the nozzle with a damp cloth after each treatment. If the device itself is
contaminated, please also clean it with a damp cloth only.
Store your device in a dry, safe place in its storage station! Do not expose the
device to direct sunlight!
9. Order accessories
10. Warranty and support
Only use original accessories and spare parts from NORA BODE Kosmetik.
OXYJET treatment products:
Please contact the authorized OXYJET GO distributor in your country.
Spare parts like nozzle and power adapter:
Please contact the authorized OXYJET GO distributor in your country.
Please contact the authorized OXYJET GO distributor in your country for more information about warranty terms.
Proof of purchase (sales receipt) is required for all warranty claims. Any defects covered by the warranty will be corrected under the
terms of this warranty. This warranty does not extend to improper use or handling, damage caused by failure to comply with the
instructions in this operating manual, accidental or physical damage/defects caused by external inuences. In such cases, the User
will be held fully liable.
Adjustment or modication of the equipment by anyone other than our authorized representatives will also render this warranty
null and void. In the case of a valid warranty claim, the authorized OXYJET GO distributor in your country will repair or replace the
defective product.
For questions about your device, preparations and treatment procedures, please contact the authorized OXYJET GO distributor in
your country or:
NORA BODE Kosmetik
Glockengasse 8
65329 Hohenstein, Germany
T: +49 (0)6120 6484
E-Mail.: info@norabode.com
DANGER
ATTENTION
NOTE
22 23

PROBLEM
The device will not turn on.
The device shuts off during
treatment.
The "Pulse" or "Flow" button does
not react
PROBLEM
The pulsed pressure is weak.
My eyes are red after the treat-
ment.
My skin is swollen and reddened
the day after treatment.
COUSE
The power adapter is not plugged into the
socket.
The DC plug of the power adapter is not cor-
rectly connected to the DC device socket.
The automatic switch-off function after 20
minutes of operation has activated.
The device has switched off automatically
because of overheating.
The main socket is defective.
The power adapter is defective.
The OXYJET GO device is defective.
The automatic switch-off function after 20
minutes of operation has activated.
The device has switched off automatically
because of overheating.
The DC plug of the power adapter has come
loose from the DC socket of the device.
The mains socket is defective.
The power adapter is defective.
The OXYJET GO device is defective.
The automatic switch-off function after 20
minutes of operation has activated.
COUSE
The device has switched off automatically
because of overheating.
The DC plug of the power adapter has come
loose from the DC socket of the device.
The mains socket is defective.
The power adapter is defective.
The OXYJET GO device is defective.
The nozzle is clogged.
The OXYJET GO device is defective.
You applied the treatment products too close
to the eye.
The air escaping during treatment irritates
your eyes.
You are allergic to one or more ingredients of
the treatment.
You exert too much pressure on your skin
during treatment.
REMEDY
Plug the power adapter into the socket.
Check that the DC plug is correctly seated in
the DC device socket on the underside of the
device.
Disconnect the device from the power supply
and let it cool down for at least 1 hour.
Disconnect the device from the power supply
and let it cool down for at least 2 hours.
Contact a qualied electrician.
Contact the customer service.
Contact the customer service.
Disconnect the device from the power supply
and let it cool down for at least 1 hour.
Disconnect the device from the power supply
and let it cool down for at least 2 hours.
Check that the DC plug is correctly seated in
the DC device socket on the underside of the
device.
Contact a qualied electrician.
Contact the customer service.
Contact the customer service.
Disconnect the device from the power supply
and let it cool down for at least 1 hour.
REMEDY
Disconnect the device from the power supply
and let it cool down for at least 2 hours.
Check that the DC plug is correctly seated in
the DC device socket on the underside of the
device.
Contact a qualied electrician.
Contact the customer service.
Contact the customer service.
Carefully unscrew nozzle, check opening and,
if necessary, pierce with a needle.
Contact the customer service.
Keep at least 2 cm distance from the eye.
Keep at least 2 cm distance from the eye!
Make sure that the nozzle blows away from
the eye during treatment by putting the
nozzle down a little less sealingly to the
cheek area. The air then escapes downwards
and not in the direction of the eye.
Stop using the products and equipment
before clarifying this. If the symptoms have
not subsided after 3 days, consult a doctor.
Apply the nozzle gently to the skin only. It
is normal for air to escape during treatment.
This does not affect your treatment result.
Please note that you are only allowed to use
the device on healthy skin.
11. Trouble shooting
24 25

12. Disposal Notes
13. Technical data
14. CE-conformity and electromagnetic compatibility
This symbol means that neither the device nor the power adapter may be disposed of with normal household
waste (2012/19/EU). If you want to dispose of the OXYJET GO device please deliver it to the nearest electronic
waste collection point for safe and efcient disposal. Correct disposal helps prevent negative consequences for
the environment and human health. Please dispose of the device according to the Waste Electrical and Electronic
Equipment Directive – WEEE. If you have any questions, please contact the local authority responsible for disposal.
This product complies with the requirements of the applicable European directives. This device complies with all
standards and regulations regarding exposure to electromagnetic elds (EMC).
Errors and changes excepted.
NORA BODE™Kosmetik
Glockengasse 8
65329 Hohenstein
GERMANY
T: +49 (0)6120 6484
F: +49 (0)6120 6329
E-Mail: info@norabode.com
Model: OXYJET GO
Power consumption: 10,8 W
Rated voltage: 12V DC
Rated current: 900 mA
Input power supply: 100 – 240 V AC / 50 – 60 Hz / 0,5 A
Output power supply: 12 V DC / max. 2,0 A (center positive)
Maximum operating time: 20 minutes
Cooling phase: Min. 1 hour (for forced shutdown min. 2 hours)
Operating temperature: +5° to +40 °C
26 27

MANUFACTURER’S ADDRESS:
NORA BODE™Kosmetik | Jutta & Lothar Bode GbR
Glockengasse 8 | 65329 Hohenstein | Germany
T +49 (0)6120 6484 | F +49 (0)6120 6329
info@norabode.com | www.norabode.com
Other manuals for OXYJET GO
1
This manual suits for next models
1
Table of contents
Other Nora Bode Personal Care Product manuals
Popular Personal Care Product manuals by other brands

Ves Electric
Ves Electric VEM-106 instruction manual

Conair
Conair BE67SNC User and care guide

Performance Health
Performance Health 09 138 4163 quick start guide

Victorian Plumbing
Victorian Plumbing VIS023 installation instructions

Noraxon
Noraxon Ultium EMG System quick start guide

Conair
Conair infiniti INFBE86RC Use and care guide