Nordic HVLS Series User manual

1
STANDARD INSTALLATION MANUAL
NORDIC HVLS FAN SERIES
ENGLISH
Vers. 1.3

2
Contents
General Safety Information, Pre-installation checks ....................................................................... 3
What’s in the Box?........................................................................................................................... 4
Required Tools & Accessories, Standard Mounting........................................................................ 5
Standard Installation Process .......................................................................................................... 6
Mounting & Securing Safety Wire................................................................................................... 7
Mounting the Air Blades ................................................................................................................. 8
Connecting Power & Controller...................................................................................................... 9
Fire Alarm Relay installation.......................................................................................................... 10
The NORDICTM HVLS Fan Series is a 230V/50Hz ‘Plug & Play’ solution. It is the ideal choice
for providing year-round comfort in air circulation and de-stratification applications.
Featuring an aerodynamic air blade design and a high efficiency direct drive motor, the
NORDIC HVLS Fan Series delivers maximum airflow at a fraction of the operating cost
of other HVLS fans. With its universally designed ceiling mount it is optimised for simple
plug-and-play installations, making it the easiest HVLS fan to install on the market.
NORDIC HVLS Series
Other manuals, such as Advanced User Guides for setting up fan
networking mode and integrating fans to a building management
system - as well as manuals in other languages can be downloaded
from our website: www.nordicfancompany.com/manuals
Download
Address
The Nordic Fan Company ApS
Snaremosevej 192A
7000 Fredericia
Denmark
contact
+45 73 70 90 83
info@nordicfancompany.com
www.nordicfancompany.com

3
1. Verify that the fan is to be installed in a location where the airblades will be a minimum of 3,0 meters above the finished floor with
a safe distance to any obstructions.
2. If the building has a mezzanine or other elevated spaces that may be occupied by people, verify that no component of the fan can
be reached from the highest level or deck. The fan must be positioned so that the tips of the airblades are a minimum of 1,2 meter
away from the furthest point that a person could extend an appendage outward.
3. Check that the fan will not be mounted in a location near overhead doors or other building openings where gusts of wind may
occur. Fans should not be installed or operated in locations where wind is present.
4. If the building is equipped with a fire sprinkler system, verify that the placement of the fan will not interfere with correct sprinkler
operation and that the fan installation complies with all building codes.
5. Check to see if the intended placement of the fan is directly below any building lights or skylights. If possible, avoid installing fans
directly below a light source to prevent a strobing effect that can be caused by fan rotation.
6. For best performance, the fan must be installed with a two-fan diameter minimum clearance to radiant heaters and HVAC system
discharges or intakes.
7. BEFORE INSTALLATION, IT IS IMPORTANT TO VERIFY THE MOUNTING SURFACE WILL BEAR THE OPERATING WEIGHT
AND MAXIMUM TORQUE (TWISTING FORCE) OF THE TO-BE-INSTALLED NORDIC™ SYSTEM. IT IS THE SOLE RESPON-
SIBILITY OF THE INSTALLER TO ENSURE THAT THE MOUNTING STRUCTURE AND FAN INSTALLATION METHOD ARE
ADEQUATE FOR SAFE OPERATION OF THE NORDIC™ FAN.
MAX TORQUE PER NORDIC™ FAN SIZE
Fan size (meter) 2,0 2,5 3,0 3,5 4,0 4,5 5,0
Max. torque (Nm) 9,0 13,5 28 39,5 45 55,5 64
8. THE FIXING MEANS FOR THE ATTACHMENT TO THE CEILING SHALL BE FIXED WITH A SUFFICIENT STRENGTH TO WITH-
STAND FOUR (4) TIMES THE WEIGHT OF THE SPECIFIC NORDIC™ CEILING FAN (SEE ALSO TABLE BELOW).
NORDIC™ SYSTEM 2,0M 2,05 3,0M 3,5M 4,0M 4,5M 5,0M
HANGING WEIGHT 31,2kg 33,7kg 36,2kg 38,7kg 41,2kg 43,7kg 46,2kg
9. INSTALLATION AND MAINTENANCE ARE TO BE PERFORMED BY QUALIFIED PERSONNEL ONLY, FAMILIAR WITH
LOCAL REGULATIONS AND EXPERIENCED WITH THIS TYPE OF EQUIPMENT.
Pre-installation checks
To reduce the risk of fire, electric shock, or injury to persons, observe the following:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the Nordic Fan Company or its
representative.
2. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent
power from being switched on accidentally.
3. Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable codes and stan-
dards.
4. DO NOT ALLOW WATER OR SOLVENTS TO ENTER THE MOTOR OR THE DRIVE. UNDER NO CIRCUMSTANCES SHOULD
MOTORS OR DRIVES BE SPRAYED WITH STEAM, WATER OR SOLVENTS.
5. It is highly recommended that an emergency disconnect switch is installed between each NORDIC™ fan and the electrical mains.
Ensure that such a switch is NOT located directly above air blades, so that it can be accessed at all times - even when fan is operating.
General Safety Information
WARNING
IMPORTANT: Consult all applicable rule and codes to ensure that all necessary requirements are met. It is the sole responsibility
of the installer to ensure compliance with applicable codes.

4
what’s in the boxes?
1
2
3
4
5
6
7
8
9
10
1
2
2
11
11
12
13
14
15
12
10
8
7
6
4
3
2
Swivel Mount
Drop Tube
Drive and Onboard Electronics
Motor
Controller
Starfish Blade Hub
1,5m CAT 5E Cable with RJ45 Plug
3m (3 x 1,5 mm2) 230V power cable
Fire alarm cable
Mount Cover
Safety Wire
Safetywire Lock (Gripple)
2 x Extension Tubes
2 x Alu Extension Connectors
Required screws and bolts
5
SCREWS FOR CONCRETE
MOUNTING
4 pcs. HUS3-H 6x80 mm.
SCREWS FOR WOOD
MOUNTING
4 pcs. 6x100 mm.
BOLTS FOR STEEL
MOUNTING
4 pcs. 8x25 mm.
4 washers, 4 locknuts
DROP TUBE & EXTENSION
TUBE BOLTS
10 pcs. 10x70 mm.
10 locknuts
15
DRILL BIT 5MM HSS NO DRILL BIT NEEDED DRILL BIT 8.5MM HSS
1SCREWS FOR MOUNTING
AIR BLADES
10 pcs. 6x20 mm.
10 lock washers, 10 capnuts
NO DRILL BIT NEEDED
NO DRILL BIT NEEDED
1
9
Anodized Aluminum
Air Blades
Required screws
and bolts
BOX 1BOX 2
13
14

5
required Tools & accessories
10,13 & 17 MM
WRENCH
LEVEL DRILL PHILLIPS
SCREWDRIVER
SLOTTED
SCREWDRIVER
SOCKET
WRENCH
3 X 1,5MM 230V
POWER CABLE
CAT 5E CABLE
LIFT OR
SCAFFOLDING
STANDARD MOunting
4 & 14 MM
ALLEN KEY
Using the swivel mount, the NORDICTM FAN SYSTEM can be
mounted directly on to standard I and H steel beams, wood
beams and concrete beams. This is done using relevant bolts
and screws as shown on page 4 and explained on page 6.
For installations using the optional mounting brackets or guy
wires, please refer to the manual: ‘INSTALLATION MANUAL
- EXTRA MOUNTING OPTIONS’ which can also be accessed
from www.nordicfancompany.com/manuals
Before performing a standard installation, please check that
the mounting beam has sufficient width to accomodate the
Swivel Mount.
If this is not the case, the extra mounting options can be
used, as explained in the manual: ‘INSTALLATION MANUAL -
EXTRA MOUNTING OPTIONS’.
10,13 & 17 MM
WRENCH SOCKET
SWIVEL MOUNT DIMENSIONS
14,6 cm
10,0 cm
8,0 cm
12,0 cm

6
Standard Installation process
Attach the fan assembly to the swivel
mount via the drop tube using bolts
specied on page 4 and fasten securely.
Fasten the swivel mount to the mounting
surface using screws (concrete and wood)
or bolts (steel). Tighten thoroughly.
Pull safety wire, power cable, re wire
and CAT 5E cable through designated
hole.
Line up the holes and tighten bolts
thoroughly.
If needed, attach one or two Extension
Tubes to the Drop Tube using the Alu
Extension connectors.
Pull power cord, re cable, safety wire,
CAT5e cable through the Extension Tube.
Using the swivel mount as a template,
drill required holes in the mounting
beam (wood beams do not require
pre-drilling of holes) using the drill bit
specied on page 4.
Secure safety wire around mounting
beam.
IMPORTANT: follow steps on page 7.
Push the mount cover up and twist to
lock in place by the two small screws as
shown above.
7
1
4
2
5
3
NOTE: IF YOU CANNOT INSTALL
DIRECTLY ON THE MOUNTING
SURFACE, YOU CAN USE EXTRA
MOUNTING BRACKETS AS
EXPLAINED IN ‘INSTALLATION
MANUAL - EXTRA MOUNTING
OPTIONS’.
8
6

7
Mounting & securing safety wire
Insert wire by pushing and twisting
clockwise into
A
Tighten wire. Cut or organize excess wire to ensure it does not interfere with fan performance.
Pull wire through
B
Pull wire around mounting beam,
and insert wire in
C
- follow arrow direction
A
B
C
NOTE: THE SAFETY WIRE MUST BE INSTALLED. THIS WILL PREVENT
THE FAN FROM FALLING IN THE UNLIKELY EVENT THAT THE MOUN-
TING SYSTEM SHOULD FAIL. THE FAN SHOULD NEVER BE OPERATED
WITHOUT A PROPERLY INSTALLED SAFETY WIRE, AS THIS COULD
RESULT IN DEATH, SERIOUS INJURY OR ASSET DAMAGE. FAILURE TO
INSTALL SAFETY WIRE WILL RESULT IN VOIDING OF THE FAN WAR-
RANTY.

8
Mounting the air blades
Slide air blade onto the starsh hub.
Air blade view from above.
Ensure air blade holes are directly over
the starsh holes.
Air blade view from below.
Secure air blade using screws and tools
as specied on page 4.
1 2 3
CORRECT POSITIONING OF THE SCREWS
NOTE: Before mounting the air blades, ensure the fan is vertically and horizontally level.
IMPORTANT: Do not operate the fan without the air blades mounted, as this may damage the
motor and the motor drive.
CHECK: ROTATE THE FAN BY HAND TO ENSURE THAT IT ROTATES FREELY AND DOES NOT COME INTO
CONTACT WITH ANY OBSTRUCTIONS.

9
Connecting power & controller
1
3
2
MOUNT CONTROLLER ON
THE WALL
CONNECT THE POWER PLUG TO THE POWER
CABLE. THEN CONNECT TO 230V SINGLE PHASE
POWER SUPPLY, USING EXTRA POWER CABLE AS
NEEDED.
CONNECT THE CONTROLLER WITH
THE FAN USING A CAT 5E CABLE
IMPORTANT:
DO NOT CONNECT THE CAT
5E CABLE TO ANYTHING
OTHER THAN THE NORDIC
CONTROLLER BOX.
DOING SO WILL SEVERELY
DAMAGE THE FAN MOTOR
AND DRIVE AND MAY
POTENTIALLY CAUSE A
MOTOR FAULT

10
FIRE ALARM RELAY INSTALLATION
4
OPTIONAL FIRE ALARM RELAY
INSTALLATION
Note: This section is only applicable in
buildings equipped with a re suppres-
sion system. For buildings without a
re suppression system, simply leave
the re cable untouched in the drop-
tube.
Important: The re alarm relay should
only be installed by qualied personnel
familiar with the operation of building
re suppression systems. It is the sole
responsibility of the installer to ensure
correct operation of the re alarm relay
in the event of re emergency in the
building.
Strip the loose wires and wire them to a
normally-closed potential free relay on the
re alarm emergency stop landing point
and the building’s re suppression system
using the wiring diagram below:
To landingpoint at fan
To re supression system
Pre-wired re alarm
landing point
24 VDC
Pre-wired re alarm
landing point
24 VDC
N.C.
Relay
THE FAN IS NOW READY FOR USE - ENJOY!
Before use, please perform an initial security check of the fan
on a secure distance by slowly increasing speed by pressing the
arrow “up” one speed level at a time. If any shaking, vibrations,
or similar appears, decrease speed immediately and make the
fan come to a complete stop. Go back and make sure all instal-
lation steps were performed correctly and make any necessary
adjustments. Perform a second check, and if any anormalities
persist, please turn off fan and contact your local support ofce.
Other manuals for HVLS Series
3
Table of contents
Other Nordic Fan manuals
Popular Fan manuals by other brands

Maico
Maico DZQ B Series Installation and operating instructions

Kendal Lighting
Kendal Lighting Triax AC-22352 Installation and operation manual

Bionaire
Bionaire BAOF25M instruction manual

Rasonic
Rasonic RLF-9KIT user manual

Ventair
Ventair GYRO 200 Installation, Use and Care Instructions

Hunter
Hunter Stile installation manual

Euromate
Euromate 482235 manual

Monte Carlo Fan Company
Monte Carlo Fan Company 5DIC44XXXD-V1 Series Owner's guide and installation manual

Vornado
Vornado 160 owner's guide

ViM
ViM KUBAIR F400 instruction manual

Panasonic
Panasonic FV-10VEC2RH Service manual

Hunter
Hunter Sea Air Owner's guide and installation manual