4270002A
2
1
3
Saturn In-line Filter
2
Part 1045928A E2003 Nordson Corporation
Manual 42-SATURNFTR-IS-02
Replacing a Filter
To install the gun filter in a system:
1. Heat the system to operating temperature, and then reduce input air
pressure to the pump to zero by adjusting the regulator.
WARNING: Failure to relieve system pressure can result in serious burns
when the gun filter connection is loosened.
2. Relieve system hydraulic pressure as described in the melter manual.
3. Disconnect and lock out input electrical power.
4. Insert a 5 mm hex tool into filter top, and rotate it counter clockwise.
Remove and discard the filter.
Figure 2 Removing the gun
filter
1. 5 mm hex key hole
2. Colored ring
3. Gun body NOTE: Make sure that the replacement filter has the same color ring as the
filter being discarded.
5. Coat the threads of the new filter with Never Seez.
6. Insert the new filter into the gun body, and tighten using the 5 mm hex
tool to 1.35 -- 2.71 NSm (1 -- 2 ft-lbs).
7. Start the system as described in the melter manual.
Filter Kits
These are the replacement parts for the Saturn integrated gun filter.
Description KitPartNumber
Kit, filter, gun, 50 mesh, Saturn 1045502
Kit, filter, gun, 100 mesh, Saturn 1045506
Kit, filter, gun, 200 mesh, Saturn 1045520
Issued 10/03
Never Seez is a registered trademark of Bostik Inc.
Saturn is a registered trademark of Nordson Corporation.