Nortek Security & Control Door-Gard Series Installation manual

6-060763 X2 1
SSW-FX Keypad Installation & Programming
Specifications
Keypad Case Dimensions:
5-1/8” L x 3-3/8” W x 5/8” D
Electrical:
Voltage: 5-12 VDC
Current (max): 15mA
Environmental:
Temperature: -20º F to 130° F
For Indoor or Outdoor Use
Features
●Vandal Resistant Metal Case
●Sealed for Indoor or Outdoor Applications
●No Moving Parts
●Touch Sensitive Piezo Keys
●LED’s for Relay Status Indication
●Surface Mount
●Rated for Greater than One Million Key Cycles
Applications
●Heavy Traffic Areas
●Rough Service Environments
●Low Profile
PRINTER’S INSTRUCTIONS:
INSTR/PROG,SSW-FX - P/N: 6-060760 X2 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: FLAT 17.000” X 11.000” FOLDED 8.500” X 11.000” - TOLERANCE: ± .125” - SCALE: 1-1
Description:
Combining elegant looks and flush mount design in a
ruggedized vandal resistant case, the Door ♦ Gard Series
SSW-FX keypad can be utilized for almost any application.
Designed to perform in high traffic and rough duty
environments, the keypad has solid state, touch sensitive
piezo keys surrounded by an aesthetically appealing
protective metal case. Encapsulated electronics make the
keypad suitable for indoor or outdoor installations.
Basic Operation:
To gain access through the door enter your code
(1-6 digits) followed by the ✱key on the keypad.
Packing List:
(1) SSW-FX Keypad
(1) Six-Conductor Wire Harness
(2) 6-32 x 1-1/2 Machine Screws
(2) # 6 1-1/2 Sheet Metal Screws
(1) 11/64”Allen Wrench
(1) Anti-Oxidant Grease Pack
(1) SSW-FX Installation/Programming Manual
Wire Harness Configuration:
Pin Wire Color Signal Name
1 Red Power (+)
2 Black Power (-)
3 White/Black Data 0
4 White/Yellow Data 1
5 Blue LED1
8 Brown Not Used
TECHNICAL SUPPORT
DEALERS/INSTALLERS ONLY! End users must
contact the dealer/installer for support. If the keypad
still does not work after troubleshooting, please call
the Technical Services department at 1-855-546-3351.
SSW-FX Keypad
Installation & Programming Instructions
Note: This product is designed to be installed and serviced
by security and lock industry professionals.

2 6-060763 X2
SSW-FX Keypad Installation & Programming
SSW-FX Keypad Installation Procedure:
Step 1: If you are mounting the keypad directly to a wall, drill a 3/4” hole into the mounting surface to allow the wire
harness connector and wires to fit through.
Step 2: On the keypad end, strip back the insulator from the wire and tape the drain wire (shield) to the jacket. Now
connect the four (see below) wires to the 6-conductor wire harness provided. The wire harness plugs into the
6-position connector on the keypad. At the other end of your wire run, strip back the insulator from the wire but
do not tape the drain wire to the jacket. The drain wire must be connected to ground at the controller end. When
using Secured Series product (such as a Max 3 or MiniMax 3), connect the drain wire to a fast-tab connector on
the backplane. Refer to the Secured Series Max 3 or MiniMax 3 manual for details.
Step 3: Finally mount the SSW-FX keypad onto the mounting surface using the provided #6 screws. Do no over-tighten
the screws, which may result in damage.
Keypad Mounting Height
Mounting height can vary depending on requirements. An appropriate range is typically between 48 and 52 inches on
center off the floor.

6-060763 X2 3
SSW-FX Keypad Installation & Programming
Wiring the SSW-FX to the Secured Series Door Control Module (DCM)
The connection between the SSW-FX keypad and a Secured Series Door Control Module requires a 4-conductor,
stranded wire with overall foil shield. The 6-conductor wire harness from the keypad connects to terminal strip TS5 on the
Door Control Module. Connect the red, black, white/black and white/yellow wires to matching terminal on the Door Control
Module (the terminals are labeled with the wire color). Refer to the wire lengths below. As mentioned in Step 2 on page 2,
the drain wire must be attached to a fast-tab on the Max 3 or MiniMax 3 backplane.
Wiring the SSW-FX to the a Third Party Wiegand Access Control Panel
The connection between the SSW-FX keypad and a WiegandAccess Control Panel requires a 6-conductor, stranded wire
with overall foil shield. Connect the red wire to V+, the black wire to V-, white/black wire to Data 0, white/yellow wire to
Data 1 and the blue wire to the LED control connection. The drain wire must be connected to ground at the controller end.
Wiring Requirements:
18 AWG – 1000 Ft.
20 AWG – 500 Ft.
22 AWG – 250 Ft.

4 6-060763 X2
SSW-FX Keypad Installation & Programming
Programming the SSW-FX Keypad
The SSW-FW keypad has it’s own local programming options. All user codes and other access control features are
programmed into the control system, either the Secured Series products or a third party Wiegand Access Control System.
Refer the those product’s documentation for programming instructions. The programming options chart below shows all
the programming commands available in the SSW-FX.
To program the SSW-FX you first must enter program mode.
To enter program mode enter the following on the keypad: 099 # program code ✱(default program code is 6789).
Programming Options Chart
Command/Action Keys to Enter/Details
Command 90
Change Local Program Code 90 # 0 # 0 # new code ✱new code ✱(default = 6789)
Command 91
Set/Clear Keypad Options
(options below, defaults in bold)91 # option # set/clear # ✱ ✱
Option Clear Set
0 – Visual Keypress Feedback 0 = Disabled 1 = Enabled
1 – Audio Keypress Feedback 0 = Disabled 1 = Enabled
3 – Front End Output Selection 0 = Secured Series Mode 1 = Wiegand Mode
4 – Secured Series IN/OUT Event Recording 0 = Record IN Event 1 = Records OUT Event
5 – Wiegand Red LED Enable 0 = Disabled 1 = Enabled
6 – Wiegand Red LED Active State 0 = Active Low 1 = Active High
7 – Wiegand Green LED Enable 0 = Disabled 1 = Enabled
8 – Wiegand Green LED Active State 0 = Active Low 1 = Active High
Note: Auto-Entry is not available in this model.

6-060763 X2 5
SSW-FX Keypad Installation & Programming
Programming Options Chart - Continued
Command/Action Keys to Enter/Details
Command 92
Program Keypad Parameters 92 # parameter # value #
Parameter Value
1 – Wiegand Format 1-8 (default = 1, 26 bit – see Wiegand format chart below)
2 – Interpulse Spacing 1-255 (default = 32, 640μS; 20μS increments)
3 – Pulse Width 1-255 (default = 8, 160μS; 20μS increments)
Command 93
Program Wiegand Site and Group ID 93 # ID Type # ID value # ✱ ✱
ID Type ID Value
0 – Site ID See Wiegand format chart below (default = 0)
1 – Group ID See Wiegand format chart below (default = 0)
Command 96
Reset Keypad to Default Settings Secured Series Front End Mode 96 # 0 # 0 # ✱ ✱
26-Bit Wiegand Front End Mode 96 # 1 # 1 # ✱ ✱
Exit Program Mode Press the ✱Key
Wiegand Format Chart
Format Value Wiegand Format Largest PIN Value Largest Site Value Largest Group Value
1 26 bit 65535 255 N/A
2 28 bit 32767 255 N/A
3 29 bit 524287 255 N/A
4 30 bit 65535 255 15
5 31 bit 65535 255 31
6 32 bit 8191 2047 63
7 36 bit 1048575 255 N/A
8 29 bit 524287 255 N/A
LED Indications
LED State Description
Red Solid Door Locked
Green Solid Door Unlocked
Yellow Solid Programming Error
Yellow Flashing Slowly (single flash) Controller Program Mode
Yellow Flashing Slowly (double flash) Front End Program Mode
Yellow Momentary Flash (key press) Visual Keypress Feedback

6 6-060763 X2
SSW-FX Keypad Installation & Programming
Testing the Keypad
After installing the keypad, it is recommended that you perform the keypad self-test once a year, to ensure that the keypad
is working properly.
To perform the self-test, with the unit powered up, press the following keys on the keypad: 7890 # 123456 ✱
●If all 12 keypresses are accepted, the keypad enters self-test mode.
●The LEDs alternate three times followed by the sounder beeping three times.
●When finished the yellow LED starts flickering rapidly.
●Press ✱to clear.
Program Mode Loopback
If you’ve forgotten the local program code use the following loopback connection to enter program mode. Power down
the unit, short the wires in the configuration illustrated, then power the unit back up. The yellow LED should be flashing.
Now change your local program code or reset the unit. Power the keypad down and reconnected the wire harness in the
original configuration.
Secured Series Front End Default Loopback Connection
The following loopback connection allows you to default the keypad in Secured Series front end mode. Power down the
unit, short the wires in the configuration illustrated, then power the unit back up. After you hear the three beeps, remove
power and reconnect the wires in the proper configuration.
Wiegand Front End Default Loopback Connection
The following loopback connection allows you to default the keypad in Wiegand front end mode. Power down the unit,
short the wires in the configuration illustrated, then power the unit back up. After you hear the three beeps, remove power
and reconnect the wires in the proper configuration.

6-060763 X2 7
SSW-FX Keypad Installation & Programming
Limited Warranty
This Nortek Security & Control product is warranted against defects in material and workmanship for twenty four (24)
months. This warranty extends only to wholesale customers who buy direct from Nortek Security & Control or through
Nortek Security & Control’s normal distribution channels. Nortek Security & Control does not warrant this product to
consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There
are no obligations or liabilities on the part of Nortek Security & Control LLC for consequential damages arising
out of or in connection with use or performance of this product or other indirect damages with respect to loss of
property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied
warranties for merchantability and implied warranties for fitness, are valid only until the warranty expires. This Nortek
Security & Control LLC Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Authorization Number (RA#). Contact Returns at
1-855-546-3351 for an RA# and other important details.
Technical Support
DEALERS/INSTALLERS ONLY! End users must contact the dealer/installer for support. If the keypad still does not
work after troubleshooting, please call the Technical Services department at 1-800-421-1587.

8 6-060763 X2
SSW-FX Keypad Installation & Programming
Copyright ©2015 Nortek Security & Control LLC
This manual suits for next models
1
Table of contents
Other Nortek Security & Control Keypad manuals