ntt CLETOP-S Series User manual

1. Introduction
Thank you for using our optical fiber connector cleaner CLETOP-S. The conventional method of cleaning optical plug
ferrule endfaces depends upon worker-skill and generally requires use of alcohol and wiping with tissue or freon gas.
However, NTT-AT’s connector cleaner CLETOP-S provides thorough cleaning of the ferrule endface by using a dry
alcohol-free cloth and all operators can consistently achieve high quality cleaning without alcohol or other solvents.
The CLETOP-S series has excellent anti-static properties to avoid reattachment of dust to the ferrule after
cleaning and is available for static sensitive applications.
The CLETOP (Stick-type) orthe NEOCLEAN(Pen-type)is also available for cleaning the ferrule end-face located
in such difficult spots as the inside of the adaptor.
Please use this product in a proper way based upon this instruction manual.
【Shape of guide sheet 】
< Liner design >
This liner design makes
cassette open easier.
This window shows what type of
rubber is set in the cassette.
Mainbody
2. Name of each part
・Single fiber connector
・Multifiberconnector
(withoutpins)
e.g. MPO, MT, MT-RJ
Type name
Type A
Type B
Shape Compatible connector
・Sigle fiber connector
e.g. SC, FC, ST, DIN, D4
LC, MU, Biconic
(ideal for φ2.5mm ferrule)
< Strap hole >
Reeve a strap in this hole anddangle
the cassette from your neck to avoid
dropping damage while at work.
< Lock button >
This button is double-locked
to avoid sudden open.
Lever Shutter
Window for showing which rubber
pad is now being set.
< Window >
Remainder of tape can beeasily
checked through this window.
Prohibited
・Do NOT store in direct sunlight, and avoid hot and/or humid environments as the product
may become deformed.
・Do NOT touch the tape (cleaning tape). The quality will deteriorate.
・Do NOT disassemble this product.
・Do NOT use for any purpose which has not been described in this manual. Products may
be damaged.
・Please consign this product to a properly lisensed waste management operator.
nd rotate it from side to side.
r thumb depressed on it, press the optical plug ferrule endface against the
move it slowly in arrow’s direction.
ped inside the cassette and simultaneously opens the shutter.
NOTE 1:
Please push the white marked part of
the lever as shown in a circle.
If you strongly push other partthan
the above, it may cause some troubles.
d if pressure to the plug is insufficient. Apply sufficient pressure to the plug to the
d.
pe vertically and move it straight. If the plug is pressed and moved aslant,
change depending upon environment and contamination types.
ainst the tape surface. Apply sufficient pressure(e.g. approx. 600gf / 0.6N
)to ensure ferrule a little deepressed.
position for cleaning.
②
ape surface. Apply sufficient pressure to ensure ferrule a little
.
.The cartridge is replaceable and you can continue to use
201801
P/N
14110501
14110511
14110601
14110611
*CLETOPisatrademarkofNTTAdvancedTechnologyCorporation.
www. .com information@itm.com1.800.561.8187

1. Introduction
Thank you for using our optical fiber connector cleaner CLETOP-S. The conventional method of cleaning optical plug
ferrule endfaces depends upon worker-skill and generally requires use of alcohol and wiping with tissue or freon gas.
However, NTT-AT’s connector cleaner CLETOP-S provides thorough cleaning of the ferrule endface by using a dry
alcohol-free cloth and all operators can consistently achieve high quality cleaning without alcohol or other solvents.
The CLETOP-S series has excellent anti-static properties to avoid reattachment of dust to the ferrule after
cleaning and is available for static sensitive applications.
The CLETOP (Stick-type) orthe NEOCLEAN(Pen-type)is also available for cleaning the ferrule end-face located
in such difficult spots as the inside of the adaptor.
Please use this product in a proper way based upon this instruction manual.
【Shape of guide sheet 】
< Liner design >
This liner design makes
cassette open easier.
This window shows what type of
rubber is set in the cassette.
Mainbody
2. Name of each part
・Single fiber connector
・Multifiberconnector
(withoutpins)
e.g. MPO, MT, MT-RJ
Type name
Type A
Type B
Shape Compatible connector
・Sigle fiber connector
e.g. SC, FC, ST, DIN, D4
LC, MU, Biconic
(ideal for φ2.5mm ferrule)
< Strap hole >
Reeve a strap in this hole anddangle
the cassette from your neck to avoid
dropping damage while at work.
< Lock button >
This button is double-locked
to avoid sudden open.
Lever Shutter
Window for showing which rubber
pad is now being set.
< Window >
Remainder of tape can beeasily
checked through this window.
Prohibited
・Do NOT store in direct sunlight, and avoid hot and/or humid environments as the product
may become deformed.
・Do NOT touch the tape (cleaning tape). The quality will deteriorate.
・Do NOT disassemble this product.
・Do NOT use for any purpose which has not been described in this manual. Products may
be damaged.
・Please consign this product to a properly lisensed waste management operator.
3. How to clean the connector
①Set the plug on the tape surface and rotate it from side to side.
(2) While pressing the lever and keeping your thumb depressed on it, press the optical plug ferrule endface against the
cleaning tape surface and move it slowly in arrow’s direction.
(1) The lever winds the cleaning tape equipped inside the cassette and simultaneously opens the shutter.
NOTE 1:
Please push the white marked part of
the lever as shown in a circle.
If you strongly push other partthan
the above, it may cause some troubles.
NOTE 2: Contamination may leave behind if pressure to the plug is insufficient. Apply sufficient pressure to the plug to the
extent that the tape is not twisted.
NOTE 3:
Press the plug against the tape vertically and move it straight. If the plug is pressed and moved aslant,
the tape may be twisted.
NOTE 4:
Cleaning performance may change depending upon environment and contamination types.
②Move the plug while pressing it against the tape surface. Apply sufficient pressure(e.g. approx. 600gf / 0.6N
for SC/FC connector and 250gf / 0.25N for LC/MU connector)to ensure ferrule a little deepressed.
Do NOT use the same position for cleaning.
【TYPE A】
① ②
①Move the plug while pressing it against the tape surface. Apply sufficient pressure to ensure ferrule a little
deepressed. Do NOT use the same position for cleaning.
【TYPE B 】
(3) Releasethelevertoallowittoreturntoitsinitialposition.
4. When the cleaning tape is running short
One cleaning tape cartridge can be used over 400 wipes.The cartridge is replaceable and you can continue to use
the CLETOP-S cassette.
①
201801
●Inquiries
NTTAdvancedTechnologyCorporation
P/N
14110501
14110511
14110601
14110611
*CLETOPisatrademarkofNTTAdvancedTechnologyCorporation.
www. .com information@itm.com1.800.561.8187
This manual suits for next models
2
Table of contents
Popular Ultrasonic Jewelry Cleaner manuals by other brands

Hedson
Hedson DRESTER BOXER D22A Original Operator's Manual

Hoover
Hoover CLEANSLATE user manual

Griots Garage
Griots Garage The Air Pulse User's manual and care instructions

Makita
Makita DCL184ZO instruction manual

Tineco
Tineco CARPET ONE SPOT Series user manual

Nilfisk-Advance
Nilfisk-Advance Mid Patio Cleaner (571/1428) user manual