REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
SPECIFICATION SHEET
80F GSVH1K.indd
Filter Maintenance
Fresh Air
Recirculation
Boost
Normal
Off
Reset Filter
FEATURES
•High Efciency Particulate Air (HEPA) Filtration
System / HEPA pre-lter, with a >90% efciency on
3.0 - 10 micron size particles to prevent premature
HEPA lter contamination. True certied HEPA lter
with a >/= 99.97% efciency on 0.3 micron particles.
Airborne particles trapped by our HEPA lter include:
Pet dander, dust, pollen, fungal spores, mold spores,
bacterial spores, airborne dust mites and cockroach
fecal antigens and proteins.
•Fresh air features:
•Tandem™** “Y” shaped transition provides
a single home outlet; stale air is exhausted
and fresh air drawn in simultaneously, without
risk of contamination. The single hole in a
home’s exterior reduces product installation
time, materials, and cost.
•AirDuo™** duo-ow, air exhaust/intake outdoor
hooded air vent, plus integrated grille, featuring
integral intake and exhaust lters, eliminates
air cross-contamination. (Optional “pine tree
spore” lter available for mild-climates with
Alpine/Pine tree vegetation.)
•AirChoke™** in response to Outdoor Air
Temperature; our system’s AirChoke™
automatically attenuates air ows to increase
system performance and owner comfort.
•AirDiffuse™** product mixing cavity is
specically designed to ensure proper mixing
of external and internal air, which possess
differing airow rates, while ensuring consistent
HEPA ltration and ventilation.
•SoftLinkage™** damper system. The
SoftLinkage™ fresh intake and stale air exhaust
dampers feature a roller cam damper system
which eliminates the need for mechanical
actuators, motors, and gear teeth with meshing
wear-out problems, and expensive damper
control logic circuitry.
GSVH1K
FRESH AIR SYSTEM
FRESH AIR SYSTEMS
HEPA FILTRATION AND FRESH AIR VENTILATION FOR THE ENTIRE INDOOR ENVIRONMENT
**Patent Pending
•GuardianPlus™ Air Systems’ fresh air
exchange eliminates excess humidity during
cold weather “heating” seasons.
•Owner Interface / Electronic, low voltage owner
interface ensures: No high voltage wiring and no
electrician required. LED indication of the products
mode of operation. LED indication of patent pending
lter alert logic facilitates owner lter maintenance to
ensure peak indoor air quality, comfort and system
efciency, which extends the product motor life.
LED indication of wiring errors facilitate installation.
Remote control (no need to go to the mechanical
room or attic) of the systems ltration operating
modes.
•Designed for Serviceability / Self-lubricating motor
needs no service. Filterglide™** system ensures
trouble free prelter and HEPA lter replacement.
Filters are changed in less than ve minutes.
•Installation Ready / Installs in less than three hours.
Installation kit included (ducting not included).
Integral AirSnap™** snap-on duct ports facilitate
rapid installation and eliminates cross contamination.
Lightweight, with integrated carrying handles. Unit
allows for vertical or horizontal installation.
•Easy-to-use wall switch included with unit / Better
unit control with three settings; normal, boost, and
recirculation modes. Includes fresh air indicator and
lter maintenance indicator.
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
MODEL GSVH1K
PERFORMANCE SPECIFICATIONS
INSTALLATION OPTIONS
Air-Flows (where applicable)
Fresh outdoor air intake (5” or 6”) 95 cfm with 5” ducts
105 cfm with 6” ducts
Stale indoor air drawn from the space
(8” duct)
270 cfm high speed
180 cfm low speed
Filter/Fresh air distributed to the
indoor space (8” duct)
270 cfm high speed
180 cfm low speed
Installation (Typical Basement, Central Draw Point)
Fresh filtered air is distributed through the whole house. Only
one outside connection is needed when using the Tandem™
transition and the AirDuo™ port*, simplifying the installation.
Filter Efficiency
Normal mode 99.97 @ 0.3 micron @ 180 cfm
Boost mode 99.82 @ 0.3 micron @ 270 cfm
Recirculation mode 99.97 @ 0.3 micron @ 180 cfm
Unit Efficiency (Filtration)
Normal mode > 87% @ 0.3 micron
Boost mode > 85% @ 0.3 micron
Recirculation mode > 87% @ 0.3 micron
*Patent Pending
Our exclusive Tandem™ transition never mixes stale
inside air (1) (coming from its duct unit (3)), and fresh air
from outside (2) (going through its unit duct (4)). Both
transition and AirSnap™ ports can be fitted with 5” and 6”
diameter insulated flexible ducts.
Also shown is our AirDuo™ exhaust/intake air vent, which
mounts on the exterior of the house. AirDuo™ is paintable
and UV-ray protected.
1
2
3
4
GENERAL SPECIFICATIONS
•For houses from up to 2,500 sq. ft.
• HVI Rated of air ow: 105 cfm
• Voltage: 120 VAC
• Frequency: 60 hz
• Power Consumed: 220 Watts (Watts in normal, boost
and recirculation modes)
• Dimensions: 29.4” x 22.9” x 17.8”
• Weight: 42 lbs
• Shipping Weight: 57 lbs
• Typical cross contamination: <3%
• Warranty: 2 years on parts and labor
• Materials (enclosure and insulation): ABS and EPS
• Agency Compliances: UL, cUL, Certied HVI airow,
and a key component in the compliance to ASHRAE
62-1999
• Wall control modes: Normal, Boost, and Recirculation

Other NuTone Air Cleaner manuals

NuTone GSHH3K User manual

NuTone

NuTone GSHH3K User manual

NuTone GSEH3K Service manual

NuTone

NuTone GSEH3K Service manual

NuTone PUREPOWER Series User manual

NuTone

NuTone PUREPOWER Series User manual

NuTone GSEH3K User manual

NuTone

NuTone GSEH3K User manual

NuTone BNAP-100 Quick reference guide

NuTone

NuTone BNAP-100 Quick reference guide

NuTone HRV90H User manual

NuTone

NuTone HRV90H User manual

NuTone GSEH3K User manual

NuTone

NuTone GSEH3K User manual

Popular Air Cleaner manuals by other brands

Kenmore PlasmaWave 85150 Use & care guide

Kenmore

Kenmore PlasmaWave 85150 Use & care guide

SCS 963E Installation, operation and maintenance guide

SCS

SCS 963E Installation, operation and maintenance guide

Prolitec Air/Q 310 user guide

Prolitec

Prolitec Air/Q 310 user guide

Frigicoll MDL-PSM10W owner's manual

Frigicoll

Frigicoll MDL-PSM10W owner's manual

Luraco L0601A operating manual

Luraco

Luraco L0601A operating manual

Dometic Breathe Easy AU9 installation manual

Dometic

Dometic Breathe Easy AU9 installation manual

Bionaire BAP260 Instruction leaflet

Bionaire

Bionaire BAP260 Instruction leaflet

AllerAir AirMedic+ Series Operation and maintenance manual

AllerAir

AllerAir AirMedic+ Series Operation and maintenance manual

Koolatron Lentek air gold XJ202 Directions for use

Koolatron

Koolatron Lentek air gold XJ202 Directions for use

AllerAir HEPA-CArbon Filtration 4000 Exec Uv brochure

AllerAir

AllerAir HEPA-CArbon Filtration 4000 Exec Uv brochure

turbionaire E20AT instruction manual

turbionaire

turbionaire E20AT instruction manual

Bioclimatic PAP SERIES Installation, operation and maintenance manual

Bioclimatic

Bioclimatic PAP SERIES Installation, operation and maintenance manual

Surgically Clean Air Cascade White How to Do

Surgically Clean Air

Surgically Clean Air Cascade White How to Do

Heshan Tech TJHQ-K Series Product specification

Heshan Tech

Heshan Tech TJHQ-K Series Product specification

Blaupunkt Lavender 2041 instruction manual

Blaupunkt

Blaupunkt Lavender 2041 instruction manual

Rowenta ECLIPSE 3IN1 CONNECT manual

Rowenta

Rowenta ECLIPSE 3IN1 CONNECT manual

Novita A5 Quick starter guide

Novita

Novita A5 Quick starter guide

Flanders Precisionaire SAR-1 Specifications

Flanders

Flanders Precisionaire SAR-1 Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.