NUUO SCB-C31A POS User manual

Metadata Plugins
Access Control, License Plate Recognition
and Point of Sale Solutions
Hardware & Software Installation
User Manual
Ver. 99.350.B0430.001

Intelligent Surveillance Solution
Table of Contents
page-1
TABLE OF CONTENTS
TABLE OF CONTENTS ..............................................................................................1
SYSTEM INTRODUCTION .........................................................................................2
Definition of Terms ..........................................................................................2
Product Specification ....................................................................................3
HARDWARE INSTALLATION ....................................................................................4
SCB-C31A POS data capture convertor.....................................................4
SOFTWARE INSTALLATION ......................................................................................6
SCB-C31 POS data capture convertor .......................................................6
Connection via COM Port ............................................................................7
Connection via TCP Client............................................................................7
NUUO NVR/DVR/Hybrid system installation ................................................7
SOFTWARE SETUP ....................................................................................................8
1. Metadata Device Management ............................................................8
1.1. Insert/Delete/Configure Metadata devices ...................................9
1.2. New/Edit/Delete/Import/Export Tag Filter .....................................11
1.3. Setup metadata Display Font..........................................................16
2. Smart Guard Detection ...........................................................................17
2.1. Metadata Event.................................................................................17
2.2. Instant Action on Metadata Event .................................................21
3. Playback ....................................................................................................22
4. Remote Network Service.........................................................................22
OPERATION TOOLS ...............................................................................................24
1. Live Display ................................................................................................24
2. Log Viewer Search ...................................................................................25
3. Metadata transaction data Search......................................................27
4. Playback video with metadata data ...................................................28
5. Backup video with metadata data ......................................................29
6. Remote Access.........................................................................................31

Intelligent Surveillance Solution
System Introduction
page-2
SYSTEM INTRODUCTION
NUUO Metadata plugins enable users to build integrated solutions with 3rd
party devices, currently including Access Control, License Plate
Recognition and Point of Sale Solutions. Please contact your local
distributor or sales service for the latest list of integrated solutions from
various suppliers.
Access Control
NUUO Main Console accepts feeds from Access Control servers via
Ethernet. You may configure several doors or entrances under each
Access Control Source. Filtered info will be displayed on chosen
channels, for example ID numbers or names of personnel upon each
entry or exit.
License Plate Recognition
NUUO Main Console also accepts feeds from License Plate Recognition
Systems via Ethernet. Several lanes may be configured under each LPR
Source. Filtered info will be displayed on chosen channels, including
license plate numbers or other additional information.
Point of Sale
NUUO POS provides a platform to display financial transaction data upon
video surveillance channels. The architecture is as below; POS
transaction data flows to NVR by Ethernet. Each Cash Register with an
external receipt printer is connected by DB9 cable. The transaction
information delivered in R232 format can be converted to Ethernet
through SCB-C31A POS data capture convertor. Alternatively, Cash
Registers that support TCP/IP or COM port output can connect directly to
the system without the SCB-C31A box.
Definition of Terms
Terms
Definition
Metadata Original Data
Original data from Metadata devices. Usually with a
lot of symbols and no line feed.
Metadata Transaction
Filtered result by user defined tag filter.
Metadata Event Log
Smart Guard Event Log from metadata transaction.
Includes transaction start, transaction end, POS cash
register open and other user defined events.
Abbreviation of Metadata Log.

Intelligent Surveillance Solution
System Introduction
page-3
To give you a better idea of the various source types supported by the
Point of Sale solution, the following sections (Hardware Installation and
Software Installation) are dedicated to POS Metadata and the hardware
POS box only. If you are not planning to install this solution, please
proceed directly to page 8 for Software Setup.
POS System Diagram
Product Specification
NUUO Capture Box
SCB-C31A POS
Input
RS232
Output
Ethernet
DC In
DC +10V to +15V
Power consumption
500 mA
Operating Temperature
-20 to 65℃
Operating Humidity
0-90 % Non-Condensing
Baud Rate
110 bps to 230.4 kbps
Data Bits
5, 6, 7 or 8
Stop Bits
1, 1.5 or 2
Parity
None, Even, Odd, Mark, Space
Flow Control
None, RTX/CTS, XON/XOFF, DTR/DSR

Intelligent Surveillance Solution
Hardware Installation
page-4
HARDWARE INSTALLATION
SCB-C31A POS data capture convertor
To connect Cash Register, Printer, and SCB-C31A POS data capture
convertor together, please follow below steps:
Step 1: Please refer the user manual to setup Cash Register and printer.
Step 2: Using a “Y-shape” DB-9 cable, one DB-9 female connect to
POS system and one DB-9 male connect to the receipt printer
Y-shape (provided by Printer vendor).
Step 3: Using another DB-9 female connect to SCB-C31A POS Data
Capture R232/Ethernet convertor with Null modem.
Note: There are two kinds of serial cable: Straight pass-through
and Null-Modem. The connection between SCB C31A POS
Data capture box and Y-cable must be null modem (in
package).
Step 4: Check the system switch of the SCB-C31A POS is switch to OFF,
OFF position.
Step 5: Connect power source with SCB-C31A POS.
Step 6: Connect SCB-C31A POS with internet port by RJ45 LAN cable.
SCB-C31A POS
Cash register
Printer
Null Modem
Y-cable
Ethernet
Provided by printer
F
F
M
M
F

Intelligent Surveillance Solution
System Introduction
page-5
The LED Indicators:
PWR LED: System is ready (Blinking).
LINK LED: Ethernet cable connection and data active.
RXA LED: Transiting/Receiving Indicator.
TXA LED: No option of SCB-C31A POS
Reset
Switch
Power
RS-232
RS-232
RJ-45

Intelligent Surveillance Solution
Software Installation
page-6
SOFTWARE INSTALLATION
SCB-C31 POS data capture convertor
Step 1: Use IE-browser to setup SCB-C31A POS, the default IP address is
192.168.1.1
Step 2: Setup IP address and password, and then setup IP address.
Note: Each time you switch the page of the web, please click
Save at first. If you leave this page without saving, all changes
will be ignored.
Step 3: Setup Password if needed. Password is only using to activate a
security feature on the serial server. Once a password is entered
it will be required to access the menu and make change of
configuration when access.
Note: Please write down the Serial number and MAC address,
these two parameters are necessary when user forget your
password.
Step 4: Setup according to your POS or Cash Register. Usually all
devices are default setting, you can reserve your time to pass
this step.
Step 5: Please restart/reset the box after changing configurations to
active setup.
To reset the unit manually apply power, insert a small plastic

Intelligent Surveillance Solution
System Introduction
page-7
tool, and press lightly depressing reset located between the
switch (refer page 5). Hold for 3 seconds and release. The Link
and Run light will go out and turn back on. The SCB-C31A POS
will revert to the last setting.
Note: Every time you change the configuration of SCB-C31A
POS, please check the above settings, especially maximum
connection and Remote IP address to avoid connection fail.
Connection via COM Port
Please install system according to following diagram:
Connection via TCP Client
Please install system according to following diagram:
NUUO NVR/DVR/Hybrid system installation
Please refer to the Main Console user manual to complete system
installation with the NVR/DVR/Hybrid systems installation CD.

Intelligent Surveillance Solution
System Setup
page-8
SOFTWARE SETUP
1. Metadata Device Management
Each NUUO Main Console system can manage up to 64 Access control,
64 License Plate Recognition and 64 POS cash register devices. This
section will teach you how to setup configuration of your system.
Run Main Console and click on Metadata Application from the
Config menu to open the Metadata Application window.
You are able to Insert/Delete/Configure Metadata devices in this window.
Click on any device under the Metadata Tree to configure the settings
and tag filter of the device. Associated cameras will be shown in the
preview window below.
Metadata
Tree
Associated
Cameras

Intelligent Surveillance Solution
System Setup
page-9
1.1. Insert/Delete/Configure Metadata devices
To insert a metadata source
1. Click the Insert button when the Metadata tab is selected
to open the Metadata Source Setting window.
2. Configure metadata source info, including Name, Metadata Type,
Source Type, IP address and Port.
Note:
For Metadata Type POS, there are 4 source types available
including SCB-C31, SCB-C31_A, COM Port and TCP Client.
3. After setting, click Test Connection to test Metadata source
connection. If all the settings are correct, the system will popup
“Metadata server “name (IP)” is available” message to confirm the
setting is successful.
To insert a metadata channel
1. Click the Insert button when any Metadata Source tab is
selected ( , or ) to add a
metadata channel.
Note:
For Metadata Type Access Control, you may add several metadata
channels under one source. Please define each Door Name exactly
the same as your settings under the third party Access Control system.
For Metadata Type LPR, you may add several metadata channels
under one source. Please define each Lane Name and make sure
settings under the third party LPR system are exactly the same.

Intelligent Surveillance Solution
System Setup
page-10
To configure settings and tag filters for each metadata channel
1. The Settings and Tag Filter section will be available when any of the
Metadata Channel tabs (Access Control , POS or LPR ) is
selected.
Settings
Record Metadata Transaction:
Select this checkbox to record metadata transaction data in MS
database. The MS data will allow searching and display on
associated recording video, and the MS data files can also provide
third-party application to analysis.
Display on Video preview:
Select this checkbox to display metadata transaction data overlay on
associated camera live videos.
There are two options regarding transaction data display:
Settings
Tag Filter

Intelligent Surveillance Solution
System Setup
page-11
Choose Always Display to keep transaction data on video until the
next transaction data is received.
Choose Last for ___ seconds to customize the period of time you wish
the transaction data to last on the video.
2. Select Tag Filter (For details on the Tag Filter, refer to page 11).
3. Under Associated Cameras, check to select cameras you wish to
display with metadata transaction data overlay on live video.
4. In Display Region Definition option, setup display area for each
camera video.
a. Default: The default display area is below the camera OSD, on
the upper-left corner.
b. User Define:Right-click on video preview and drag a rectangle
to define the display area.
5. Click OK to save.
To delete a metadata source/channel
1. Choose metadata source/channel.
2. Click Delete button to remove this metadata source/channel
from the system.
To configure metadata source/channel
1. Choose metadata source/channel.
2. Click Configure button to open Metadata Source Setting
window.
3. Please refer to Insert metadata device section (page 9) to modify
configuration.
1.2. New/Edit/Delete/Import/Export Tag Filter
Raw transaction data received from metadata systems must be filtered to
make it comprehensible. NUUO also provides a simple default tag filter
that filters out common EPSON commands. Users can edit other
customized filters based on this default tag filter.

Intelligent Surveillance Solution
System Setup
page-12
To add a new Tag Filter
1. Click on the New button to open the Tag Filter window.
This window includes the following sections:
a. General: Setup Tag Filter name. Connect button for test
connection.
b. Original Data: Show original transaction data from POS device.
c. Filtered Data: Show filtered data after defined filter.
d. Filtered Function buttons: Tool used to define filter type.
e. Filter List: A list of all filters.
f. Data tools: Includes import/export buttons to import/export
original binary data, and a clear button to clear original/filtered
data windows.
g. Filter tools: Includes upper/down tool to arrange priority of each
filter, or remove filters from list. You may also edit existing filters or
add new ones.
h. Encoding: Choose desired language.
i. Transaction Timeout: Define a maximum time length for
transactions to end when no more data is received.
General
Original
Data
Filtered
Data
Filtered Function
Filter List
Data Tools
Filter Tools
Encoding
Transaction
Timeout

Intelligent Surveillance Solution
System Setup
page-13
2. Enter name of tag filter.
3. Click Connect button to capture metadata transaction data from
metadata device.
4. Please operate metadata device to send transaction data to filter.
The original transaction data will show on the left window.
Note: If you don’t want the data to keep importing when editing
filters, please click the Disconnect button to stop connection.
5. Data Tools:
Export: Capture and export original Binary data
Import: Reload exported Binary data.
Clear: Remove data form Original Data and Filtered Data windows.
6. Start to edit tag filters:
Click and highlight text from Original Data window, then use the six
buttons below to define filters. The filtered transaction data will
show on the right window.
a. Omit: Neglect the selected text which is meaningless or not
important. The text will disappear in the filtered data window
on the right.
b. Substitute: Use other words to replace the selected text. The
system will pop up a substitution panel for replacing desired
words. The text on the filtered data window will show the result.
c. Add New Line: Define the selected text as the symbol for
changing to a new line. The result will show on the right filtered
data table.

Intelligent Surveillance Solution
System Setup
page-14
d. Start: Define the selected text as the symbol for the beginning of
a transaction. It will be replaced as a line as shown below.
Note: This setup is also used as detection tag for Smart Guard to
detect Transaction Start event.
e. End: Define the selected text as the symbol for the end of a
transaction. It will be replaced as a line as shown below.
Note: Not defining a transaction end may result in error or lost
info. If you do not define this filter please be sure to define a
transaction timeout. For more info please refer to p.15.
This setup is also used as detection tag for Smart Guard to
detect Transaction End event.
f. Cash Register Opened: Define the selected text as the symbol
for cash register opened. The filtered data will show the <Cash
Register Open> mark as below.
Note: This setup is also used as detection tag for Smart Guard to
detect Open Cash Register event.
7. Filter Tools:
The buttons are used to change priority of sub filter criteria.
The filter will operate by order of list; the filters on top will take effect

Intelligent Surveillance Solution
System Setup
page-15
first. The button will remove the filter from this list. Click on
Edit / Add to configure tag filters or add new ones.
8. Click on OK to save configuration.
Note: If codepage of POS printer is different with Windows OS, please
correspond with POS printer to setup Encoding option.
If there is no defined Transaction End event, please define a maximum
time length for transactions to end when no more data is received.
To Edit Tag Filter
1. Select Tag Filter name from drop-down menu,
2. Click Edit button
3. Configure the Tag Filter window.
4. Click OK to save configuration.
To Delete Tag Filter
1. Select Tag Filter name from drop-down menu,
2. Click Delete button
To Import/Export Tag Filter
1. Click Import/Export button and select Import/Export URL.
2. Click Open/Save to Import/Export Tag Filter.

Intelligent Surveillance Solution
System Setup
page-16
3. After importing tag filters, users can simply select a tag filter from the
drop-down menu without editing a new one.
1.3. Setup metadata Display Font
This option allows to setup font of metadata transaction data on video.
1. Run Main Console, click on
Metadata Application from
Config menu to open Metadata
Application window, then switch to
Display tab.
2. For metadata transaction data
displayed overlay video, select the
font, font size, font color and any
font effects user wants.

Intelligent Surveillance Solution
System Setup
page-17
2. Smart Guard Detection
2.1. Metadata Event
Each Metadata System has four to five Event types:
Transaction Start - Detect any transaction beginning
Transaction End - Detect any transaction ending
Open Cash Register - Detect any cash register opening
(Only available on POS metadata devices)
User Defined - Detect any condition which is defined by user
Connection Lost –Detect any connection abnormal event
between the metadata and Main Console systems.
Note: First three events require a pre-defined detection tag, please
refer to Edit Tag Filter section (see page 13).
To add a new Metadata Event
1. Select metadata device ( , or )from device tree.
2. Click on button to open Select Event Window.
3. Select Event Type.
4. Setup basic option of Event.

Intelligent Surveillance Solution
System Setup
page-18
a. Enable Event: Check the box to activate.
b. Life Cycle:
Manually cancel event or event last triggered:
The alarm/action will continue until being canceled from Main
Console (Start>Open Event Report>Cancel All Events). The
user currently not at the seat watching the screen will be
notified by the alarm.
Cancel event after ___ seconds:
Enable checkbox and setup the timeout seconds to cancel
the event after the time that you set whether the events
disappear or not.
c. Activated Period:
Always Activated:
Allow alarm to be activated at all times.
As Day Mode Schedule
Customize a specific time range for the alarm to be activated.
The alarm will be available daily according to your settings.
Click on Day Schedule to configure the schedule.
Choose Add Time Period and drag on the coverage bar to
define an activated schedule.
Choose Remove Time Period and drag on the coverage bar
to subtract from existing schedules.
Click on Clear All to remove all settings.

Intelligent Surveillance Solution
System Setup
page-19
As Week Mode Schedule
Customize a weekly based time range for the alarm to be
activated.
Click on Week Schedule to configure the schedule.
Choose Add Time Period and drag on the coverage bar to
define an activated schedule.
Choose Remove Time Period and drag on the coverage bar
to subtract from existing schedules.
Click on Clear All to remove all settings.
5. Setup advanced option of User Defined Event.
a. Event name: Enter the name of user defined event.
b. Alert Condition:
Text:
Enter the text user wants to detect in Keyword column.
Enable Match case to search for names where the case
matches the letters you entered. Or enable Match whole
word to search for the terms you entered as a whole word.
Check Using Regular Expression to include regular expression
commands in search.
Numeric value:
Enter a number as the condition of event and then choose
one of the symbols ( ≦<=>≧) to define the numeric
value.
Other manuals for SCB-C31A POS
3
This manual suits for next models
1
Table of contents