UNLESS NOTED, DIMENSIONS ARE IN
MILLIMETERS & TOLERANCES ARE:
ENGINEER:
SIZE:
REV.
DRAWN BY:
X.
X.X
X.XX
X.X
X.XX
1 MM
0.5 MM
0.20 MM
0.3 MM
0.10 MM
X
1
X.X
0.5
INTERPRET PER ASME Y14.5M-1994
BRACKETED DIMENSIONS ARE IN
INCHES FOR REFERENCE ONLY
THRID ANGLE PROJECTION
LRF
APPROVED BY:
PART NO:
TITLE:
PROJECT:
A3
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS
GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN
PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT
WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON
LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE
E1
2022/05/13
RP2310****_DA
Rack
Power
SHEET
1 OF 3
SCALE:N/A
ECN/ECO
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
E1
INITIAL DRAFT REVIEW
2022/05/13
LRF
$ $
% %
& &
' '
( (
) )
* *
+ +
- -
. .
/ /
0 0
































Advantage Series
Metered Switched
(DEFAULT) TOP FRONT FEED = 0
BOTTOM FEED = 2
(DEFAULT) 3m [10'] = 0
(DEFAULT) BLACK = 0
RED = R
GREEN = G
MODEL IS SHOWN IN DEFAULT CONFIGURATION. FOR
OPTIONAL CONFIGURATIONS, USE ITEM IDENTIFIER
CODE IN PLACE OF EACH ASTERISK. ORDERABLE
BASED ON FORMAT: RP2310* * * *
DO NOT INCLUDE TRAILING ZEROS IN * * * * SUFFIX
OPTIONS LISTED ON THIS ROW ARE NON STANDARD,
CONTACT SALES FOR ADDITIONAL INFORMATION
RP 2310
0.5m [1.6'] = A
1.5m [4.9'] = B
2.5m [8.2'] = C
1.2m [4'] = G
1.8m [6'] = F
(DEFAULT) L5-20P=0 BLUE = B
WHITE = W
YELLOW = Y
IDENTIFICATION TABLE
INPUT PLUG CHASSIS COLOR CORD OPTION ORIEN
*
TATION
ORANGE = A
1m [3.2'] = 1
2m [6.6'] = 2
* * *
NOTES :
NATIONAL, STATE
1. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE
AND LOCAL CODES.
2.
3.
PRIMARY DIMENSIONS ARE IN MILLIMETERS. SECONDARY DIMENSIONS
ARE IN [INCHES]
UNIVERSAL MOUNTING BRACKET IS AN ALTERNATIVE MOUNTING
METHOD TO THE TOOLLESS MOUNT FOR 3RD PARTY ENCLOSURES.
BRACKET IS PROVIDED WITH THE UNIT.
4. DETAILED INSTALLATION INSTRUCTIONS CAN BE FOUND IN THE QUICK
START GUIDE
5. CONNECT EXTERNAL EARTH GROUND TO THE 10-32 SIZE THREADED NUT
6.
7.
SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
INPUT PLUG CONFIGURATION (SEE IDENTIFICATION TABLE) FOR DUAL-
RATED UNITS, NEMA PLUGS ARE NAM RATED ONLY AND CAPTIVE AUS/NZ
PLUGS ARE EMEA RATED ONLY
MAX OPERATING
ELEVATION, ABOVE MSL
HUMIDITY
(OPERATING/STORAGE)
METERING
ACCURACY
5-90% RH / 5-95% RH;
NON-CONDENSING
VOLTAGE(V), CURRENT(A), APPARENT
POWER(kVA), REAL POWER(kW),
POWER FACTOR, ENERGY(kWh)
3000M(9840FT)
RoHS COMPLIANT
COMPLIANCE
SAFETY&ENVIRONMENTAL
METERING ATTRIBUTES
FEATURES
INPUT POWER CORD:
METERED COMPONENTS
REMOTE OUTLET SWITCHING
ENVIRONMENTAL CONDITIONS
OPERATING TEMPERATURE
STORAGE TEMPERATURE
INPUT PLUG:
RATED POWER:
INPUT PHASE:
BREAKER QTY & TYPE:
INPUT CURRENT:
INPUT VOLTAGE:
OUTLET QTY & TYPE:
ORIENTATION:
UNIT TYPE:
TECHNICAL SPECIFICATIONS
MONITORED SWITCHED
VERTICAL, 0U HALF
(12)5-20R
100-120VAC
20A (16A DERATED)
N/A
SINGLE-PHASE
1.9kVA
SEE NOTE 7
SEE IDENTIFICATION TABLE
+-1% TO ISO/ IEC 62052-21
INPUT(PHASE), CIRCUIT BREAKERS
YES
-5 TO 60 C (23 TO 140 F)
-20 TO 60 C (-4 TO 140 F)
FRONT VIEW
SIDE VIEW
BOTTOM VIEW
[LIGHT GRAY] [LIGHT GRAY]
1000
10
100
Reset
Senso
Port 2
r
RackPower
100
10
Senso
Port 1
r
INPUT CORD
LENGTH SEE
IDENTIFICATION
TABLE
UNLESS NOTED, DIMENSIONS ARE IN
MILLIMETERS & TOLERANCES ARE:
ENGINEER:
SIZE:
REV.
DRAWN BY:
X.
X.X
X.XX
X.X
X.XX
1 MM
0.5 MM
0.20 MM
0.3 MM
0.10 MM
X
1
X.X
0.5
INTERPRET PER ASME Y14.5M-1994
BRACKETED DIMENSIONS ARE IN
INCHES FOR REFERENCE ONLY
THRID ANGLE PROJECTION
LRF
APPROVED BY:
PART NO:
TITLE:
PROJECT:
A3
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS
GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN
PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT
WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON
LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE
E1
2022/05/13
RP2310****_DA
Rack
Power
SHEET
2 OF 3
SCALE:N/A
ECN/ECO
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
E1
INITIAL DRAFT REVIEW
2022/05/13
LRF
$ $
% %
& &
' '
( (
) )
* *
+ +
- -
. .
/ /
0 0
































NOTES
:
1.
INSTALLATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL,
STATE AND LOCAL CODES.
2.
SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
INPUT PLUG
(DEFAULT)
RECEPTACLE RECEPTACLE
OPTIONAL
RECEPTACLE
EXTERNAL GROUND
NEMA L5-20P, 2P 3W
20A, 125V MAX RATED INPUT
16A DERATED
NMC SHOWN IN DEFAULT
ORIENTATION
2.2
.09
Ø
10.4
.41
2.0
.08
BUTTON MOUNTING SCREW
(INCLUDED)
18.4 [.60]
02817,1*%87721
$"$$"$
%-(- $'&-(-
$
!--'#&%--!"$ &"!-$!%$-






$ 
$ $+-!&)"$-" '!&"!%-
$$
'-"&%)#-"$-"$!&&"!-!%-
$$$
-$ -
%%+-!-$ -
,!($"! !& "!-
'$&+-$ -
$'&-$$-$ -
 $$"$



 





# $$
"$-$'!!+--%!-
! $$
'##"$&%-*&$!-%!%"$%--#$#$%-
Advantage Series
Metered Switched
NEMA 5‐20R
16A, 125V MAX
RATED OUTPUT
NEMA 5‐20R
16A, 125V MAX
RATED OUTPUT
1000
10
100
Reset
Senso
Port 2
r
RackPower
100
10
Senso
Port 1
r
RECEPTA
STANDARD
CLES
UNLESS NOTED, DIMENSIONS ARE IN
MILLIMETERS & TOLERANCES ARE:
ENGINEER:
SIZE:
REV.
DRAWN BY:
X.
X.X
X.XX
X.X
X.XX
1 MM
0.5 MM
0.20 MM
0.3 MM
0.10 MM
X
1
X.X
0.5
INTERPRET PER ASME Y14.5M-1994
BRACKETED DIMENSIONS ARE IN
INCHES FOR REFERENCE ONLY
THRID ANGLE PROJECTION
LRF
APPROVED BY:
PART NO:
TITLE:
PROJECT:
A3
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS
GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN
PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT
WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON
LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE
E1
2022/05/13
RP2310****_DA
Rack
Power
SHEET
3 OF 3
SCALE:N/A
ECN/ECO
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
E1
INITIAL DRAFT REVIEW
2022/05/13
LRF
$ $
% %
& &
' '
( (
) )
* *
+ +
- -
. .
/ /
0 0
































NOTES
:
INSTALLATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL,
1.
STATE AND LOCAL CODES.
SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
2.
THIS DRAWING DEPICTS THE POWER SYSTEM CONNECTIONS AND
3.
IS NOT REPRESENTATIVE OF THE PHYSICAL LAYOUT. PLEASE
REFER TO MECHANICAL DRAWINGS FOR PHYSICAL LAYOUT.
COMPLIANCE LABEL
SKU #: RP2310WXYZ
Model #: EP23016-0020
INPUT:100-120VAC, 1PHASE, 50/60Hz, 16A
OUTPUT:5-20R; 100-120VAC, 16A per outlet
16A Total
MAC0 Address:XX-XX-XX-XX-XX-XX
MAC1 Address:XX-XX-XX-XX-XX-XX
RackPower Distribution Unit
II..TT..EE..
EE334422772200
Metered Switched
Mfr.Name:XXXXXXXXXXXXXXXXXXXXXXXXX
Made In XXXXX (Factory ID: X) SKU#
:
R P2310WX Y Z
Serial Number
XXXXX X X X X X
57435
PRODUCT CODE
nVent Electric plc
1665 Utica Ave, Suite 700
Minneapolis, MN 55416
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
OPERATION IS SUBJ ECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
CAN ICES-3(A)/NMB-3(A)
INTERNAL WIRING SCHEMETIC
2. FOR FINISHED GOOD PART NUMBER SEE IDENTIFICATION
Advantage Series
Metered Switched

This manual suits for next models

1

Other nVent SCHROFF Power Distribution Unit manuals

nVent SCHROFF Rack Safety Plus 3 U User manual

nVent SCHROFF

nVent SCHROFF Rack Safety Plus 3 U User manual

nVent SCHROFF RP 2319 User manual

nVent SCHROFF

nVent SCHROFF RP 2319 User manual

nVent SCHROFF RackPower EP01024-0013 User manual

nVent SCHROFF

nVent SCHROFF RackPower EP01024-0013 User manual

Popular Power Distribution Unit manuals by other brands

Vertiv LIEBERT MPX BRM Quick installation guide

Vertiv

Vertiv LIEBERT MPX BRM Quick installation guide

Brandywine PDU-240 user guide

Brandywine

Brandywine PDU-240 user guide

ABB 615 Series ANSI Technical manual

ABB

ABB 615 Series ANSI Technical manual

Hill Audio RPL-1000 user manual

Hill Audio

Hill Audio RPL-1000 user manual

Siemens Sivacon S8 Planning information

Siemens

Siemens Sivacon S8 Planning information

EuroLite SB-1100B user manual

EuroLite

EuroLite SB-1100B user manual

ITT POWERLOCK BOX Translation of the original operating instructions

ITT

ITT POWERLOCK BOX Translation of the original operating instructions

P.Lindberg Aqualine Original manual

P.Lindberg

P.Lindberg Aqualine Original manual

CleanSweep AREC144FG user guide

CleanSweep

CleanSweep AREC144FG user guide

Vertiv Knurr Di-Strip Blade Power manual

Vertiv

Vertiv Knurr Di-Strip Blade Power manual

Essential Audio Tools Mains Multiplier 6+ user manual

Essential Audio Tools

Essential Audio Tools Mains Multiplier 6+ user manual

CTR Electronics PDP user guide

CTR Electronics

CTR Electronics PDP user guide

Geist ZP Series instruction manual

Geist

Geist ZP Series instruction manual

LEGRAND PLUGMOLD PM48TC installation instructions

LEGRAND

LEGRAND PLUGMOLD PM48TC installation instructions

Brandywine TDU-310 user guide

Brandywine

Brandywine TDU-310 user guide

CyberPower PDU15SW8FNET user manual

CyberPower

CyberPower PDU15SW8FNET user manual

Panamax M4400-20A Specifications

Panamax

Panamax M4400-20A Specifications

ITC T-6216 Operation manual

ITC

ITC T-6216 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.