RTD7AL
RTD temperature sensor for temperature measurement up to
900°F (482°C) in division 1 locations Installation Instructions
WARNING:
3 in (76 mm)
2 in (51 mm)
4.25 in
(108 mm)
3/4-in NPT
(19 mm)
conduit
opening
3 in (76 mm)
2 in (51 mm)
4.25 in
(108 mm)
3/4-in NPT
(19 mm)
conduit
opening
The nVent RAYCHEM RTD7AL temperature sensor is a three-wire platinum RTD
(resistance temperature detector) typically used with monitoring and control systems
when accurate temperature control is required. The sensor is explosion proof and
approved for Division 1 and 2 hazardous locations. The RTD7AL can be used with a wide
variety of RAYCHEM monitoring and control systems.
These installation instructions detail the installation of the RTD7AL in conjunction with
existing RAYCHEM component kits.
TOOLS REQUIRED
• 3.5 mm flat-blade screwdriver
ADDITIONAL MATERIALS REQUIRED
• Pipe straps
• Conduit with 16–22 AWG shielded instrument cable or equivalent armored cable
APPROVALS
The RTD7AL is CSA Certified for use in North America by the manufacturer for use in
Division 1 and Division 2 hazardous locations as follows:
Class I, Division 1, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class I, Division 2, Groups A, B, C, D
Class II, Division 2, Groups E, F, G
KIT CONTENTS
Qty Description
1 RTD Temperature Sensor
SPECIFICATIONS
Sensor housing Aluminum; Type 4X
Sensor sheath 316 stainless steel
Range –100 to 900°F (–73 to 482°C) max
Accuracy ±1°F (0.5°C) at 32°F (0°C)
Resistance 100 ohms at 0°C α =0.00385 ohms/ohm/°C
Connection 3/4 in. NPT conduit hub
Operating Ambient –40°F to 212°F (–40°C to 100°C) for all gas groups except
Group A. –4°F to 212°F
(–20°C to 100°C) for gas Group A
DESCRIPTION
This component is an electrical device. It must be installed
correctly to ensure proper operation and to prevent shock or
fire. Read these important warnings and carefully follow all the
installation instructions. Component approvals and performance
are based on the use of specified parts only. Do not use
substitute parts or vinyl electrical tape to make connections.
WIRING INFORMATION
The length of RTD extension wires is determined by the wire
gauge used.
To reduce the likelihood that electrical noise will affect
temperature measurement, keep RTD extension wires as short
as possible.
Use shielded instrument cable such as
RAYCHEM MONI-RTD-WIRE (22AWG, PVC insulation, –30°F to
140°F, –20°C to 60°C) or Belden 83553 (22 AWG, FEP insulation,
–95°F to 395°F,–70°C to 200°C).
Maximum RTD extension wire length
AWG Feet (meters)
16 4500 (1400)
18 2800 (880)
20 1800 (550)
22 1100 (340)
C1D1 INSTALLATION WITH HEATING CABLE
Electrical Wiring Notes:
Most electrical codes (such as NEC 725–15) permit Class 1 circuits
to occupy the same cable, enclosure, or raceway without regard
to whether the individual circuits are alternating current or direct
current, providing all conductors are insulated for the maximum
voltage of any conductors in the cable, enclosure or raceway.
Additional Materials Required
• Approved junction box (supplied by others)
• HAK-C-100
• Pipe straps
Agency approved
Div 1 junction box
(supplied by others)
HAK-C-100
Div 2
Div 1
Pipe strap
Place pipe strap under heating cable
RTD DIRECT CONNECTION
Pipe strap
Place strap under heating cable
Conduit
drain
RTD7AL WIRING
Connect the wires as shown.
1 Note: Ground RTD extension wire shield at
one end only, preferably at RAYCHEM electronics end.
2 Note: RTD housing must be properly grounded
using the screw provided.
Electrical schematic of RTD
Red (Source)
White
Red
Red Red (Compensate)
Field Wiring
White (Common return)
North America
Tel. +1.800.545.6258
Fax +1.800.527.5703
[email protected]
Europe, Middle East, Africa
Tel. +32.16.213.511
Fax +32.16.213.604
[email protected]
Asia Pacific
Tel. +86.21.2412.1688
Fax +86.21.5426.3167
[email protected]
Latin America
Tel. +1.713.868.4800
Fax +1.713.868.2333
[email protected]
nVent.com
©2018 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its aliates. All other trademarks are the property of their respective owners.
nVent reserves the right to change specications without notice.
Raychem-IM-H56916-RTD7AL-EN-1805 PN 229056-000

Other nvent Temperature Controllers manuals

nvent Raychem RTD4AL User manual

nvent

nvent Raychem RTD4AL User manual

nvent Raychem RTD-200 User manual

nvent

nvent Raychem RTD-200 User manual

nvent Raychem RTD3CS User manual

nvent

nvent Raychem RTD3CS User manual

nvent 1244-006265 User manual

nvent

nvent 1244-006265 User manual

nvent Raychem Raystat-Control-11-DIN User manual

nvent

nvent Raychem Raystat-Control-11-DIN User manual

Popular Temperature Controllers manuals by other brands

SmartSense Temp/Humidity Booklet

SmartSense

SmartSense Temp/Humidity Booklet

LAE electronic TMR15 Instructions for use

LAE electronic

LAE electronic TMR15 Instructions for use

dixell IC200CX Series Quick reference guide

dixell

dixell IC200CX Series Quick reference guide

PolyScience Standard Controller Models Operator's manual

PolyScience

PolyScience Standard Controller Models Operator's manual

VDH ALFANET 79 PI user manual

VDH

VDH ALFANET 79 PI user manual

Omron E5EC datasheet

Omron

Omron E5EC datasheet

ABB TTF300 Operating	 instruction

ABB

ABB TTF300 Operating instruction

Jaga Briza 22 installation instructions

Jaga

Jaga Briza 22 installation instructions

PSG DC10 operating manual

PSG

PSG DC10 operating manual

Regin TG-R5W Instruction

Regin

Regin TG-R5W Instruction

Dimplex RTK 601 U manual

Dimplex

Dimplex RTK 601 U manual

SBC PCD7.LR-TR42 installation instructions

SBC

SBC PCD7.LR-TR42 installation instructions

Nibe S Series manual

Nibe

Nibe S Series manual

Honeywell T7560A installation instructions

Honeywell

Honeywell T7560A installation instructions

Vescent SLICE-QT quick start guide

Vescent

Vescent SLICE-QT quick start guide

Jaga CLIMA CANAL-JDPC user manual

Jaga

Jaga CLIMA CANAL-JDPC user manual

Busch-Jaeger 1094 U product manual

Busch-Jaeger

Busch-Jaeger 1094 U product manual

Simrad PI TEMPERATURE - DATASHEET REV A datasheet

Simrad

Simrad PI TEMPERATURE - DATASHEET REV A datasheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.