NVT NV-4PS10-PVD User manual

Pow r Supply Int grator Hub Installation Guid Mod ls
NV-4PS10-PVD and NV-16PS10-PVD
1) Re d these instructions.
2) Keep these instructions.
3) Heed ll w rnings.
4) Follow ll instructions.
5) Do not use this pp r tus ne r w ter.
6) Cle n only with dry cloth.
7) Do not block ny ventil tion openings.
8) Inst ll in ccord nce with the m nuf cturer’s instructions.
9) Do not inst ll ne r ny he t sources such s r di tors, he t
registers, stoves or other pp r tus (including DVRs) th t
produce he t.
10) Do not defe t the s fety purpose of the pol rized or
grounding-type plug. A pol rized plug h s two bl des with
one wider th n the other. A grounding type plug h s two
bl des nd third grounding prong. The wider bl de or the
third prong re provided for your s fety. If the provided plug
does not fit into your outlet, consult n electrici n for
repl cement of the obsolete outlet.
11) Protect the power cord from being w lked on or pinched
p rticul rly t plugs, convenience recept cles, nd the point
where they exit from the pp r tus.
12) Only use tt chments/ ccessories specified by the
m nuf cturer.
13) Use only with c rt, st nd, tripod, br cket, or t ble
specified by the m nuf cturer, or sold with the pp r tus.
When c rt is used, use c ution when moving the
crt/ pp r tus combin tion to void injury from tipover.
14) Unplug this pp r tus during lightning storms or when
unused for long periods of time.
15) Refer ll servicing to qu lified service personnel.
Servicing is required when the pp r tus h s been d m ged
in ny w y, such s power supply cord or plug is d m ged,
liquid h s been spilled, or objects h ve f llen into the
pp r tus, the pp r tus h s been exposed to r in or
moisture, does not oper te norm lly,
or h s been dropped.
This installation should be made by a qualified
service person and should conform to all local codes.
WARNING - Do not install the unit in an environment
where the operating ambient temperature exceeds 122° F
(50° C). The ventilation should not be impeded by
covering the ventilation openings with items, such as
newspapers, table-cloths, curtains, etc. No naked flame
sources, such as lighted candles should be placed on the
apparatus.
WARNING - Do not interconnect multiple
outputs.
WARNING - The apparatus shall not be exposed to
dripping or splashing and no objects filled with liquids,
such as vases, shall be placed on the apparatus.
WARNING - Use only a Certified power cord and plug
(coupler / mains) assemblies for location installed.
WARNING - Power cord is regarded as main
disconnect.
WARNING - The appliance coupler (power
cord/mains) shall remain readily operable.
WARNING - For safety, never put N T signals in the
same conduit as high-voltage wiring.
WARNING - Do not restrict airflow around any active
powered N T products.
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT
REMO E CO ER OR BACK. NO USER SER ICEABLE
PARTS INSIDE. REFER SER ICING TO QUALIFIED
SER ICE PERSONNEL.
WARNING: TO REDUCE THE RISK OF ELECTRICAL
SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR
MOISTURE.
IMPORTANT SAFETY INSTRUCTIONS
Active or Passive Receiver Hub
Integrated PVD power with
New NV-4PS10-PVD or NV-16PS10-PVD
Camera Location and
Transmitter Connections IDF | Telecom Room
and Midspan Connections MDF | Control Room
and Receiver Connections
NV-216A-PV
NV-218A-PVD
Camera
Camera
IP
The NVT Power Supply Cable ntegrator Hub combines a 1 Amp /channel
power supply with pass through video and telemetry data, for 4 to 16
cameras, all over UTP wire. Designed for installation in the wiring/ DF
telecom closet, or at the Control /MDF room, the Hub consolidates
connectivity via standard 4-pair RJ45 E A/T A 568B compliant premises
wiring and pinouts.
At the camera, Power, Video and Data connections are made using the
NV-216A-PV (power-video only), the NV-218A-PVD or the NV-226J-PV via an
RJ45 connector and a single 4-pair cable. Control/MDF room video
connections are achieved with a single 4-pair RJ45 cable for each group of
four cameras. Telemetry data connections (if required) also achieved with
another single 4-pair RJ45 cable for each group of four cameras.
The NV-4PS10-PVD supports up to four cameras in a compact wall- or
desk-mount chassis. The NV-16PS10-PVD supports up to 16 cameras in
a 1U wall- desk- or rack-mount chassis.
Wir Typ
The Power Supply Cable ntegrator Hub operates well with Category
Unshielded Twisted-Pair (UTP) wire, 24-22AWG (0,5-0,64mm)
The video signal may co-exist in the same wire bundle as other video,
telephone, data, control signals, or low-voltage power. t is also OK to run
NVT signals near electromagnetic fields (in accordance with National
Electrical Code, and other local safety requirements).
DO NOT USE individually shielded twisted pair. Overall shielded, multi-pair
(6pr +) is OK.
Do NOT use un-twisted wire.
Due to near-end crosstalk, do not send a transmit and a receive signal in the
same wire bundle. Exception: Up to 2,000ft (600m) Category 5. Wire in
underground conduit or wet locations must be polyethelyne-jacketed, gel-
filled. Wire in plenum environments must be plenum-rated, per local codes.
RS-422, RS-485, and Up-the-Coax Pan/Tilt/Zoom telemetry signals are
supported.
NVT recommends the use of factory-crimped RJ45 patch cables rather
than unreliable field-crimped RJ45s to connect between the NVT device
and an adjacent female RJ45 jack.
Wir Distanc
All measured distances include any coax in the path.
Wire resistance may be measured with an ohm-meter by shorting the two
conductors together at the far end, and measuring the loop-resistance out
and back.
Loop R sistanc p r 1,000ft (300m)
24 AWG (0,53 mm) = 52 ohms
23 AWG (0,57 mm) = 42 ohms
22 AWG (0,64 mm) = 33 ohms
Wire distances are limited to the minimum of:
POWER DISTANCE - and -VIDEO DISTANCE
Vid o Distanc
Wire distance between the camera through the Power Supply Cable
ntegrator and on to the video receiver should not exceed:
Passive-to-Passive 750ft (225m)
Passive-to-Active 3,000ft (1km)
Pow r Distanc
Wire distance between the Power Supply Cable ntegrator and the camera is
dependent on the camera’s current draw. Please refer to the Power Distance
Guides below.
Conn cting PVD at th Cam ra End
Use the NV-216A-PV for fixed cameras, the NV-218A-PVD for fixed or P/T/Z
cameras, or the NV-226J-PV for 12 VDC cameras. nstall per the instructions
that come with the transmitting device using 4-pair wire and RJ45
connectors. Wiring pinouts are:
Conn cting PVD at th Pow r
Supply Cabl Int grator Hub
Bring the 4-pair PVD cable from each camera back to the location of the
Power Supply Cable ntegrator. NVT recommends that an RJ45 Patch Panel
be used here in conjunction with RJ45 patch-cords. Use of these E A/T A
568B compliant practices allows for easy testing with an RJ45 (LAN) tester,
as well as moves and changes.
Connect the PVD signals into ports on the front of the Power Supply Cable
ntegrator.
1
2
3
4
5
6
7
8
Wht/org
Org/wht
Wht/grn
Blu/wht
Wht/blu
Grn/wht
Wht/brn
Brn/wht
Video +
Video
-
Data +
Power
-
Power +
Data
-
Power +
Power
-
Fixed Camera 24VAC only, used with NV-216A-PV
Power Supply Voltage
Minimum Voltage at Camera
789ft (240m)
994ft (303m)
393ft (120m)
495ft (151m)
262ft (80m)
331ft (101m)
1,840ft (561m)
2,320ft (707m)
916ft (279m)
1,155ft (352m)
612ft (186m)
771ft (235m)
B&W Camera, 2.4 W
2-pair 24 AWG
2-pair 23 AWG
Color Camera, 4.8 W
2-pair 24 AWG
2-pair 23 AWG
Color Camera, 7.2 W
2-pair 24 AWG
2-pair 23 AWG
24 VAC
21 VAC
28 VAC
21 VAC
Fixed 12VDC Camera used with NV-226J-PV
Power Supply Voltage
1,586ft (748m)
1,999ft (609m)
795ft (242m)
1,002ft (306m)
2,220ft (677m)
2,799ft (853m)
1,113ft (339m)
1,403ft (428m)
B&W Camera, 2.4 W
2-pair 24 AWG
2-pair 23 AWG
Color Camera 4.8 W
2-pair 24 AWG
2-pair 23 AWG
24 VAC 28 VAC
P/T/Z 24VAC Camera used with NV-218A-PVD
Power Supply Voltage
Minimum Voltage at Camera
90ft (27m)
113ft (35m)
210ft (64m)
265ft (81m)
P/T/Z Camera, 21 W
2-pair 24 AWG
2-pair 23 AWG
24 VAC
21 VAC
28 VAC
21 VAC
Fixed Dual Voltage 24VAC/12VDC Camera with NV-216A-PV
Power Supply Voltage
Minimum Voltage at Camera
1,753ft (534m)
2,210ft (674m)
874ft (266m)
1,102ft (336m)
583ft (178m)
735ft (224m)
2,454ft (748m)
3,094ft (943m)
1,223ft (373m)
1,542ft (470m)
816ft (249m)
1,029ft (314m)
B&W Camera, 2.4 W
2-pair 24 AWG
2-pair 23 AWG
Color Camera, 4.8 W
2-pair 24 AWG
2-pair 23 AWG
Color Camera, 7.2 W
2-pair 24 AWG
2-pair 23 AWG
24 VAC
14 VAC
28 VAC
14 VAC
Cat 5 Wire Distance
Cat 5 Wire Distance
235
315
400
475
550
630
700
780
3 MHz
4 MHz
5 MHz
6 MHz
9 MHz
8 MHz
7 MHz
10 MHz
100ft
Camera Lines of Resolution
Frequency
300ft
1,000ft
1 mile
3,000ft
10,000ft
30m
100m
300m
1,6km
1km
3km
M
a
x
P
a
s
s
i
v
e
D
i
s
t
a
n
c
e
M
a
x
S
t
u
b
E
Q
D
i
s
t
a
n
c
e
M
a
x
D
i
g
i
t
a
l
E
Q
D
i
s
t
a
n
c
e

Conn cting th Vid o Outputs from th
Pow r Supply Cabl Int grator to th
Control Room
Connect the RJ45 jack video outputs on the rear of the Power Supply
Cable ntegrator to the UTP receiver in the Control Room. Use the same
E A/T A 568B wiring practices as below. Wiring pinouts are:
The NV-4PS10-PVD supports channels 1 through 4.
The NV-16PS10-PVD supports channels 1 through 16.
Data Conn ctions
The data path for each camera arrives on the front RJ45 jack of the
Power Supply Cable ntegrator. Each Data jack supports the pass-
through of four camera data signals. Use a 4-pair Cat5 cable to bring
these data signals back to the Control Room. For small installations,
these wire pairs may be connected directly to the RS-422/485 telemetry
control output on your controller. n most cases a “Code Distribution Unit”
(available from the camera manufacturer) is inserted between the
telemetry output and the wire-pairs. This allows one telemetry output to
drive many cameras without having to drive too many loads. t also
prevents a fault at one camera from taking down the entire system.
NV-16PS10-PVD Rack/Tabl Mounting
Ambient temperature must be below 122°F (50°C). Airflow must be
at least 4ft3/min (0,1m3/min) of un-restricted airflow. Many DVRs
produce enough heat to exceed this temperature without external
airflow.
For rack mounting, attach the supplied mounting brackets to the
Hub chassis using the supplied screws. Note that the brackets alllow
installation with the front or rear facing out.
Because the NV-16PS10-PVD weighs 22lbs. (10kg), some thinner-
gauge rack systems may require additional rear support. NVT provides
a rear-rail mounting accessory kit (see Accessories) for this purpose.
NV-16PS10-PVD Wall Mounting
Attach the optional mounting “L” brackets to two sides of the unit, using
the enclosed screws. The brackets may be installed facing outward or
inward. nward facing brackets allow the unit to be mounted on 16“
centers, useful in US wall stud applications. For easy connector and LED
access, it is recommended that the front of the unit faces left.
NV-4PS10-PVD Wall Mounting
For wall mounting, hang unit onto (2) Pan head screws mounted to
plywood backboard. Screw heads should be secured approximately 1/2”
(1,2cm) off board surface and spaced 4.5” (11,43cm) apart.
4.5”
1/2”
T chnical Sp cifications
Video Pass-through
Power Output
3 Position 24VAC, OFF or 28VAC
Volta e Switch Per-channel switch selectable
Current 1 Amp per channel
NV-16PS10-PVD 10Amp aggregate
Protection Automatic resetting termistor
Connectors and Impedance
UTP input RJ45 100 ± 20 ohms
UTP output RJ45 100 ohms
LEDs
Power Blue
Channel Status see page 1
Environmental
Temperature 32 to 122°F (50°C)
Humidity 0 to 95% non-condensing
Transient immunity per ANS / EEE687 C62.41
NV-4PS10-PVD
Voltage 115/230 VAC
Frequency 50/60 Hz 1.25 Amp
Wattage 125 W
Heat 50 BTU/Hr (power supply only)
420 BTU/Hr
(power supply with camera)
NV-16PS10-PVD
Voltage 115/230 VAC
Frequency 50/60 Hz 3.0 Amp
Wattage 325 W
Heat 125 BTU/Hr (power supply only)
1,200 BTU/Hr
(power supply with camera)
Power Input
EC380 nlet
Power Cord
EC380 AC line power receptacle for use
with removable cords. Use only the power
cord provided with the unit or equivalent
UL approved type SJT or SVT, 18AWG,
125/250V, 5A 60 deg.C, Max. 4,5m long;
One end with NEMA 5-15P. Other end with
appliance coupler.
Fuse 5 x 20 mm Type T
NV-4PS10-PVD 2.5 Amp
NV-16PS10-PVD 5.0 Amp
A spare fuse is located inside the fuse holder.
Mechanical (Excluding brackets and connectors)
Dimensions
NV-4PS10-PVD
W9.25” (23,5cm) H1.75” (4,5cm) D7.25” (18,4cm)
NV-16PS10-PVD
W17” (43,2cm) H1.7” (4,5cm) D12” (30,5cm)
Wei ht
NV-4PS10-PVD
Product Weight 7.0lb (3,14kg)
Packaged Weight 8.4lb (3,81kg)
NV-16PS10-PVD
Product Weight 22lb (10kg)
Packaged Weight 28.46lb (12,90kg)
Accessories
NV-4PS10-PVD
-Rubber feet for desk applications (attached)
-Hole cutouts in bottom for wall mount
-Power cable EC power cord 7ft (215cm)
-NV-4PSRMBK (rack mount kit) purchased separately
NV-16PS10-PVD
-Mounting: Rackmount “L” brackets for front or rear
installations; rubber feet for desk applications
-Rack screws: 4 12-24 x 3/4” Phillips Pan Head
-Power cable EC power cord 7ft (215cm)
-Optional Mounting Support Bracket Kits
Model NV-RMBK (rear mount kit) purchased separately
Model NV-WMBK (wallmount kit) purchased separately
Ag ncy
These NVT products are listed and/or conform
to the following certifications and directives:
UL Listed to UL2044 or UL/ EC 60065.
cUL Listed to CAN/CSA22.2 No. 1 for Canada.
CE Mark under EMC and low voltage Directives for the
European Union. Complies with FCC part 15B limits
Troubl shooting
f you are experiencing problems, attempt to simplify your setup. Test
each cable segment separately. For example, test the camera and
monitor together without the other equipment. Then add in the NVT
transceivers, back-to-back. Test each segment of a long cable-run
independently. Attempt to isolate the problem.
Custom r Support
NVT customer support is available for consultation from 8:00 AM to 5:30
PM PST Monday through Friday. n addition, emergency after-hours
callback support is available.
US Office: (+1) (650) 462-8100
US Fax: (+1) (650) 326-1940
UK Office: (+44) (0)20 8977 6614
UK Fax: (+44) (0)20 8973 1855
Email USA: www.nvt.com/email
Email UK: www.nvt.com/email
Web home page: www.nvt.com
R turns
Please call before returning units to NVT. Returned materials must have
a “Returned Materials Autorization” (RMA) number from NVT marked on
the outside of the shipping carton.
Limit d Lif tim Warranty
NVT warrants that the product conforms to NVT’s applicable published
specifications and is free of defects for the life of the product. There shall
be no other warranties, express, statuatory, or otherwise, including any
implied warranty of merchantability, of fitness, or any other obligation on
the part of NVT with respect to any of the products.
n the event that any of the products is damaged, altered, or modified
without the express written consent of NVT, any warranty for those
products will cease and NVT will have no further liability as it pertains to
those products.
NVT assumes no responsibility for damages or penalties incurred
resulting from the use of this product in a manner or location other than
for which it is intended.
NVT’s liability under any warranties shall be discharged by replacing or
repairing any part or parts which do not conform to the applicable
warranty under normal and proper use. NVT’s liability with respect to any
product shall not exceed a refund of the price received by NVT for that
product, and in no event shall NVT have any liability for any incidental,
consequential, special, or indirect damages.
Some states do not allow the exclusion or limitation of special,
incidental, or consequential damages, so the above limitations or
exclusions may not apply to you. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.
Specifications subject to change without notice
Example Data Connections and Pinouts
NV-218A-PVD
NV-4PS10-PVD,
or NV-16PS10-PVD
PVD Jack
Data Jack
To Control Equipment
Pin Data UTPColor
1Video+White/Orange
2 Video-Orange/White
3 Data+White/Green
4Power-Blue/White
5 Power+White/Blue
6 Data- Green/White
7Power+White/Brown
8 Power-Brown/White
Pin Data UTPColor
1+ Data 2, 6, 10 or 14 White/Orange
2 - Data 2, 6, 10 or 14 Orange/White
3 + Data 3, 7, 11 or 15 White/Green
4- Data 1, 5, 9 or 13 Blue/White
5 + Data 1, 5, 9 or 13 White/Blue
6 - Data 3, 7, 11 or 15 Green/White
7+ Data 4, 8, 12 or 16 White/Brown
8 - Data 4, 8, 12 or 16 Brown/White
Copyright © 2011 NVT, nc. 451-610-1-J
08/11
Ch. 2, 6, 10, 14
Ch. 1, 5, 9, 13 Ch.3, 7, 11, 15
Ch. 4, 8, 12, 16
1
2
3
4
5
6
7
8
Conn cting Pow r
CAUTON: Before applying power, set voltage selection switch to proper
input line voltage. Test your PVD connections with an RJ45 (LAN) wiring
tester prior to applying power.
Connect the EC cable between the power inlet and a grounded electrical
outlet. Switch on the power switch and observe the blue power LED.
LED Chann l Pow r Status
Channel Power Status LEDs (each channel)
OFF: No camera connected (<50mA)
GREEN: Valid camera load detected
AMBER: Caution: Miswire possible
Detects that current in each of the four power conductors is the same,
allowing for the detection of open conductors. For short wire runs under
100 feet on fixed cameras, small mis-matches in connector resistance
may cause LEDs to show Amber. n this case, first verify the wire
continuity with a ohm meter or LAN tester. f no fault found then ignore
as condition is normal. Above 100 feet, or with high current P/T/Z
cameras, the amber LED is an indication that the wire continuity should
be checked with a ohm meter or LAN tester for miswires.
RED: Over-current shutdown. Check for shorts in the wiring.
RoHS