NVT NV-ET1804 User manual

Condensed Installation GuideFour Port PoE+ Transmitter
Model NV-ET1804
View the complete guide at www.nvt.com
56VDC
Power
Supply
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
7) Install in accordance with the manufacturer’s instructions.
8) Do not install near any heat sources such as radiators,
heat registers, stoves or other apparatus that produce heat.
9) Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wider blade or the
third prong are provided for your safety. If the provided plug
does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10) Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.
11) Only use attachments/accessories specified by the
manufacturer.
12) Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been damaged
in any way, such as a power supply cord or plug is damaged,
liquid has been spilled, or objects have fallen into the appara-
tus, the apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped. This
installation should be made by a qualified service person and
should conform to all local codes.
13) Low Voltage Connections: The installation shall be in
accordance with the applicable provisions of the National
Electrical Code ANSI/NFPA 70, Article 800.90 and Canadian
Electrical Code Part 1, Section 60-504.
The NVT Model NV-ET1804 Four-Port PoE+ Transmitter is a
compact media converter that allows 10/100 BaseT Ethernet
and PoE, PoE+, or high-power PoE to be transmitted using
coax, UTP, or other cable. These devices are typically used
in legacy installations where existing coax or other wire is
redeployed as part of an upgrade to IP. 56VDC class 2 power
at one transceiver is distributed to multiple remote transmit-
ters, and their PoE cameras (or other devices).
These transceivers are extremely simple to use, with no IP or
MAC address configuration required. Status LEDs indicate
power, link quality, and link connectivity/activity for RJ45
and BNC ports.
The NV-ET1804 is backed by NVT’s award winning customer
support and limited lifetime warranty.
IMPORTANT SAFETY INSTRUCTIONS
PRODUCT DESCRIPTION
FCC USER INFORMATION
Before installing, NVT recommends
downloading and reading the complete
installation manual from www.nvt.com.
Transceivers must be configured prior to use. See page 2.
Use one NV-ET1804 Transmitter at the remote (camera) end.
Multiple remote transceivers and cable runs may be
connected to the control room Receiver using any combina-
tion of star and daisy-chaining.
Data signals over the coax are capable of extended
distances, however voltage-drop in the 56V power distribu-
tion will often vary, depending on the camera’s current draw
and wire resistance.
56VDC power is typically supplied to the whole system by the
control-room transceiver, however power may also be
provided locally if desired.
WARNING: For safety, never use more than
two power supplies within a TBus channel. Never use
more than one 60 watt remote power supply on each
TBus channel.
INSTALLATION INSTRUCTIONS
Network Video Technologies
(+1) 650.462.8100 •+44 (0) 208 977-6614
nvt.com •www.nvt.com/email
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT
REMOVE COVER OR BACK. NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
WARNING: TO REDUCE THE RISK OF ELECTRICAL
SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR
MOISTURE.
UL Listed to IEC/UL 60950-1 Complies with FCC part 15A limits
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the
receiver.
- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician
for help.
WARNING
Changes or modifications not expressly approved by the
manufacturer could void the user’s authority to operate the
equipment.
Page 1 of 2
!
PoE+
Cat5
IP Camera
IP Camera
IP Camera
IP Camera
≤328ft
(≤100m)
≤328ft
(≤100m)
Cat5
Hybrid
DVR
or
NVR
Monitor
LAN/WAN
Switch
or
Router
any wire
or
or
or
NV-ET1801
NV-ER1804
NV-ER1808i
NV-ER1816i
NV-ET1804
This installation should be made by a qualified service
person and should conform to all local codes.
WARNING - Do not install the unit in an environment
where the operating ambient temperature exceeds 185° F
(85° C). The ventilation should not be impeded by covering
the unit with items, such as newspapers, table-cloths,
curtains, etc. No naked flame sources, such as lighted
candles should be placed on the apparatus.
WARNING - Do not interconnect multiple
power supply outputs. Never use more than two power
supplies within a TBus channel. Never use more than
one 60 watt remote power supply on each TBus channel.
Do not connect additional loads which would exceed the
marked output current rating of the power supply.
WARNING - The apparatus shall not be exposed to
dripping or splashing and no objects filled with liquids, such
as vases, shall be placed on the apparatus.
WARNING - Use only a Certified power cord and plug
(coupler / mains) assemblies for location installed.
WARNING - Power cord is regarded as main
disconnect.
WARNING - The appliance coupler (power cord/
mains) shall remain readily operable.
WARNING - For safety, never put NVT signals in the
same conduit as high-voltage wiring.
This product is intended to be supplied by a certified power
source marked “Class 2” or “LPS” and rated 56 VDC, 30mA
minimum, 1,600mA maximum, which may or may not be
provided with the product.
Power supplies, when provided, are external inline, with an
IEC380-C14 power inlet and 6 ft (1.8 m) line-cord. Input
Voltage is 100 ~240 VAC 50-60 Hz. Output voltage is
56VDC, 1.07A or 1.6A. A molded P1J 5.5 mm barrel
connector provides a Class 2 (SELV) 56 VDC regulated
output. Line cord UL approved type SPT-2, SVT, or SJT, 18/3
AWG Min. 300VAC, 60° C Max. 15 ft (4.5 m) long. One end
with IEC380-C13 appliance coupler and the other end with
NEMA 1015P or equivalent for country.
Complies with these regulatory agency certifications and
directives.
!
!
!
!
!
!
!
!
®

10/100PoE+ 56VDC
CONFIGURATION INSTRUCTIONS
Page 2 of 2
Copyright © 2014 NVT, Inc.
451-1804-1-A1
2014/01
The NV-ET1804 TBus transmitter delivers high bandwidth encrypted Ethernet signals over virtually any kind of wire (Coax, UTP, STP, Un-twisted wire, etc.).
To provide utmost signal integrity and security, the NV-ET1804 transceivers must be configured to communicate exclusively with other transceivers within their
TBus Network Group. This group typically consists of one or more remote Transmitters, typically
located at the IP camera and one Receiver, typically located at the
control-room. Transmitters may be the NV-ET1801 or NV-ET1804. The Receiver may be the NV-ET1801, NV-ER1804, NV-ER1808i, or NV-ER1816i.
Before functioning on the network, each NV-ET1804 must learn which other transceivers are to be part of that group. This simple process is called Joining.
It is recommended that transceivers in each Network Group be configured prior to deployment using these instructions:
Step One: Gather Materials
●All 1800 series Transceivers
●RJ45 patch-cord
●Small paper-clip, partially straightened
●Device labels
●IP Network Documentation Log
Step Two: Connect Hardware
●Remove and discard the “Configure Before Use” labels.
●Use an RJ45 patch to connect the TBus ports of two Transceivers.
CAUTION: Never connect the RJ45 TBus port to an RJ45 ethernet port.
●Apply power to one of the TBus devices.
●The blue POWER LED on each Transceiver will blink for 8 seconds and then go on.
●
After 20 seconds, verify that the green TBus Link LED on each transceiver is off.
If a TBus Link LED is on, the Transceiver has been previously joined.
Perform the un-joining process below before proceeding.
Step Three: Joining
●On Transceiver #1, using the straightened paper-clip, momentarily depress and release
the small JOIN push-button located on the front of the unit.
Its blue Power LED will begin blinking.
●Depress and release the same push-button on the Transceiver #2.
Its blue Power LED will begin blinking.
(The NV-ER1808i and NV-ER-1816i Receiver Hubs also have a web browser-based Join button.)
●Both Transceivers have now entered Join Mode.
They will find each other and establish encrypted communication.
In about 10 seconds, the blue Power LEDs on both Transceivers will return
to a steady on condition, and their green TBus Link LEDs will illuminate,
indicating a successful Join.
●One TBus Link LED will remain on solid. The other may wink with data.
Step Four: Adding Transceivers (if required)
●Disconnect Transceiver #1 and replace it with a new un-joined Transceiver.
●
Repeat steps two and three to add additional Transceivers to the same Network Group.
Step Five: Documentation
●Label the configured Transceivers with a unique Network Group ID of your choice.
This will help you identify them after they have been deployed.
●Record this Network Group information in your IP Network Documentation Log:
This log may include essential documentation which will help you identify all system devices during and after deployment.
The NV-ER1808i and NV-ER1816i have data entry fields for this purpose.
Un-Joining a Transceiver
If you need to move a Transceiver from one Network Group to another, it must first un-learn its
previous Network Group and be returned to an un-joined state. Do this by:
●Apply power.
●The blue POWER LED on each Transceiver will blink for 8 seconds and then go on.
●Using the straightened paper-clip, depress the small JOIN push-button until the blue Power LED goes off (about 13 seconds).
●Un-joining is now complete.
If you are not sure that un-joining has been successful, remove and then re-apply power, and repeat.
●Camera Number
●Camera Position/Location
●Camera Make & Model
●Camera MAC & IP Address
●Camera Login & Password
●Camera-end NVT Transceiver MAC Address
●NVT Transceiver Network Group Name
●Control Room NVT Transceiver MAC Address
●Control Room Router Port Number
Transceiver #1
Transceiver #2
56V Power Supply
Join Button
Join Button
Transceiver #1
Transceiver #2
Join Button
Join Button