Nywint DK4711 User manual

DK4711-41 KIT
2 WIRE INTERCOM SYSTEM
Please read this manual carefully before using the product you purchase, and keep it well for future use.We reserve the right to
modify the specication in this manual at any time without notice.
RF CARD
Quick Guide


-1-
1. Product Lists Of Kits
Kit DK4711 consists of:
1* Outdoor Station- DT607FE/ID/S1/RH
1* Indoor Unit- DT47MG-W
1* Power Supply with UL approved- DR-30-24
1* Power Separator- DT-DPS
1* DIN Rail
1* Relay- DS-ERL
1* AWG18 Power Cable
2* Management Cards- Add Card & Delete Card
5* Proximity Cards
Kit DK4721 consists of:
1* Outdoor Station- DT607FE/ID/S1/RH
2* Indoor Units- DT47MG-W
1* Power Supply with UL approved- DR-30-24
1* Power Separator- DT-DPS
1* DIN Rail
1* Relay- DS-ERL
1* AWG18 Power Cable
2* Management Cards- Add Card & Delete Card
5* Proximity Cards
Kit DK4722 consists of:
1* Outdoor Station- DT607FE/ID/S2/RH
2* Indoor Units- DT47MG-W
1* Power Supply with UL approved- DR-30-24
1* Power Separator- DT-DPS
1* DIN Rail
1* Relay- DS-ERL
1* AWG18 Power Cable
2* Management Cards- Add Card & Delete Card
5* Proximity Cards

-2-
Kit DK4731 consists of:
1* Outdoor Station- DT607FE/ID/S3/RH
3* Indoor Units- DT47MG-W
1* Four Outputs Controller- DT-DBC4A1
1* Power Supply with UL approved- DR-30-24
1* Power Separator- DT-DPS
1* DIN Rail
1* Relay- DS-ERL
1* AWG18 Power Cable
2* Management Cards- Add Card & Delete Card
6* Proximity Cards
Kit DK4741 consists of:
1* Outdoor Station- DT607FE/ID/S4/RH
4* Indoor Units- DT47MG-W
1* Four Outputs Controller- DT-DBC4A1
1* Power Supply with UL approved- DR-30-24
1* Power Separator- DT-DPS
1* DIN Rail
1* Relay- DS-ERL
1* AWG18 Power Cable
2* Management Cards- Add Card & Delete Card
8* Proximity Cards

-3-
2. System Connection
One Apartment Connection
-
+
L1 L2 PL S+ S-
ID=0
Code=00, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
RF CARD
+-
DPSDR-30-24
-
+
L1 L2 PL S+ S-
ID=0
Code=00, DIP6=off
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
RF CARD
+-
DPSDR-30-24
Code=01, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches

-4-
Two Apartments Connection
Three Apartments Connection
-
+
L1 L2 PL S+ S-
ID=0
Code=00, DIP6=off
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
RF CARD
+-
DPSDR-30-24
Code=16, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
-
+
L1 L2 PL S+ S-
ID=0
RF CARD
Code=01, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
Code=02, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
Code=03, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
+-
DPSDR-30-24
OFF
ON
DBC4A1
A B C D Impedance
switch

-5-
Four Apartments Connection
Connecting Multi Door Stations
ID=0
1st door station
ID=1
2nd door station
ID=2
3rd door station
ID=3
4th door station
L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S- L1 L2 PL S+ S-
Monitors
RF CARD RF CARD RF CARD RF CARD
OFF
ON
Impedance
switch
DBC4A1
A B C D
DPSDR-30-24
+-
-
+
L1 L2 PL S+ S-
ID=0
RF CARD
Code=01, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
Code=02, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
Code=03, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
Code=04, DIP6=on
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
+-
DPSDR-30-24
OFF
ON
DBC4A1
A B C D Impedance
switch

-6-
3. Parts and Functions
[1]
[7]
[2]
[3]
[4]
[5]
[6]
[8]
[9]
[10]
SD card
1 2 3 4 5 6
ON DIP
Key functions
NO. Item Description
[1] Digital LCD touch screen See the next page for details
Display the visitors' image
[2] Emergency button Press it & hold for 3s to send SOS message to mobile
phone,the function is supported by GSM unit.
[3] Message indicator Light up when the monitor has missed call
[4] Unlock button Press to release the door
[5] Talk/Mon button Press to communicate hands free with visitor
Press to view the outdoor condition in standby mode
[6] Microphone Transmit audio from one station to other stations
[7] SD card slot Use to insert micro-SD card
[8] Mounting hook Use to hang up the monitor
[9] Speaker Send out sounds of ring tones,audios and alarms
[10] Connection port Bus terminal

-7-
Terminal description
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
SW+
SW-
RING
GND
NC
1 2 3 4 5 6
ON DIP
L1,L2: Bus line terminal.
SW+,SW-: Extra door bell call button connection port.
Ring,GND: Extra buzzer connection port.
NC: Undened.
DIP switches: Total 6 bits can be congured.
• Bit1~Bit5: User Code setting.
• Bit6: Set to ON if the monitor is at the end of the line or works with DBC4A.
Otherwise, set to OFF.

-8-
[11]
[10]
[9]
[1]
[3]
[4]
[8]
[7]
[6]
[5]
[12]
[13]
[2]
4. Terminal Description For Outdoor Station
1 2 3
Lock Control Jumper
PIR Motion Detector
Connect Port
+12V
GND
PIR
L1 L2
PL
S+ S-
Main Connect Port
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Front panel
[7] Speaker
[8] Night view LED
[9] Camera lens
[10] Rainy cover
[11] Mounting hook
[12] Connection port
[13] Screw hole
Lock Control Jumper: To select the lock type.
Motion Detector Connect Port: To connect
external PIR motion detector.
Main Connect Port: To connect the bus line
and the electronic locks.
• L1,L2: Connect to the bus line, no polarity.
• PL: External lock power input, connect to the
power positive(power +).
• S+: Lock power(+) output.
• S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not
be connected).

-9-
Total4addressescanbecongured.Itcanbemodiedeitherbeforeorafterinstallation.
0 is default, to change the setting, please follow the steps:
6. Settings Address Of Outdoor Station
5. Functions Setting Up Of Outdoor Station
UNLOCK Indicator:OFF
TALK Indicator:OFF Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
the first door station.
Press KEY_2 button to set
the second door station.
Press KEY_3 button to set
the third door station.
Press KEY_4 button to set
the fourth door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep,Beep
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
• If setting mode has not been exited, you can change the address of door station by pressing KEY1~4 freely.
• The LED_NAME indicator will always blink until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button four times to exit out the setting mode manually.
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
RF CARD
This section explains the settings of each
function,please refer to the following table:
To perform the settings for the function you
want,you should move away the metal front
panel. Please refer to the sketch map.
Each operation is indicated by the lighting up
of the LED indicator on the unit, and by the
sounding of the buzzer.

-10-
7. Setting Unlock Mode For Outdoor Station
8. Setting Unlock Time For Outdoor Station
By default, the unlock time is 1s, but it can be changed,the setting range is 1s~99s.
Follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep,Beep......
Press and hold on KEY_2
button. The time you holding
on is the new unlock time.
• When entering time delayed setting, the buzzer sound one time every second.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button twice to exit out the setting mode manually.
There are 2 unlock modes, Normally opened and Normally closed.
Normally opened is default, to change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set
the unlock mode to
Normally opened.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button again
to set the unlock mode to
Normally closed.
Press KEY_1
• If setting mode has not been exited, you can change the unlock mode by pressing KEY1 circularly.
• The LED_NAME indicator will blink all the time until exit out the setting mode.
• If without any operation in 10 seconds, it will exit out setting mode automatically.
• In this step,press KEY_SET button twice to exit out the setting mode manually.

-11-
9. Indoor Unit Parameter Setting
How to enter the installation setting page
How to know the machine code
• On main menu page, touch [Logo] icon to enter About page.
• When the screen stay in About page,press UNLOCK button on front panel and
hold for 2 seconds.
• A keypad is shown.
Refer to the followings:
00:10 DS-1
About
Local Address 00.00
Video Standard AUTO
System Verson 00.01.00
Display Driver 1.0
Font 1.0
UI 1.0
INSTALLER SETUP 123
_
? + OK: Help Menu
@ + OK: Address Setting Menu
Input the key “? and ok” to open Help instructions menu.
Refer to the followings:
Help 01/04
2412:Reset to Default Setting
2499:Format Memory
2810:MCU Code Update
2811:TFT,UI Code Update
2812:Consumer Tune Update
2813:Format SD Card
INSTALLER SETUP 123
_
? + OK: Help Menu
@ + OK: Address Setting Menu

-12-
DIP Switches Settings Of Indoor Unit
TheDIPswitchesareusedtosettheusercodeforeachmonitor.Total6bitscanbecong-
ured.
• Bit-1 to Bit-5 are used for user code setting. The value range is from 0 to 31, which have 32
different codes for 32 apartments.
• When multi monitors need to be installed in one apartment, these monitors should use the
same user code, and the master/slave mode should be set on the monitor.
• Bit-6 is bus line terminal switch, which should be set to “ON” if the monitor is at the end of
bus line, otherwise be set to “OFF”.
ON(1)
=
OFF(0)
=
ON
ON
ON DIP
123456
Bit state Setting Bit state Setting
1 2 3 4 5
6
ON DIP
1 2 3 4 5
6
ON DIP
When monitor is not
at the end of bus line.
When monitor is at
the end of bus line.
Bit-6 switch setting
ID0=ID32

-13-
11. Electric Lock Connection (NOT RECOMMENDED). See Page 13.
1) Door Lock Controlled with Internal Power
1.Electronic lock of Power-on-to-unlock type
should be used.
2.The door lock is limited to 12V, and holding
current must be less than 250mA.
3.The jumper should be placed on position 2 and
3 before connecting.
4.The door lock control is not timed from Exit
Button(EB).
5.The Unlock Mode must be set to 0 (by de-
fault).
Note: NOT RECOMMENDED unless the door lock is less than 250mA. Please see Part 13
on Page 13 for HOOKING UP A DOOR RELEASE.
EB
*
LOCK
Jumper position on 2&3
1 2 3
L1 L2 PL S+ S-
10. Answering a Call
When there is a call from a video door station.The call tone sounds, an image will be
displayed on the screen.
Touch icon on screen or press TALK/MON button on the panel, begin
communicating hands free with the visitor for 90 seconds.
While communicating with the visitor, unlock the door, capture images/videos and adjust
screen&volume are available. More details,please refer to the following descriptions.
Note: 1.If nobody answers the phone, the screen will be turned off automatically after 40 seconds.
2.The 5 direction pad operation should make in effect with sh-eye door station.

-14-
12. Specication
2) Door Lock Controlled with External
Power
1.The external power supply must be used
according to the lock.
2.The inside relay contact is restricted to
230Vac 1A or 24Vdc 1A.
3.The jumper must be taken off before
connecting.
4.Setup the Unlock Mode according to
different lock types.
• Power-on-to-unlock type:Unlock
Mode=0(by default)
• Power-off-to-unlock type:Unlock
Mode=1
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER
SUPPLY
Power supply: 26Vdc
Power Consumption Of Outdoor Station: 0.85W in standby;
3.25W in working.
Power Consumption Of Indoor Unit: 0.29W in standby;
7W in working.
Camera lens: Color CMOS, 2.0 Mega pixel
1/2.7’’sheyecamera,1700wideangle
Unlock Power output: 12Vdc,250mA
Unlock timing: 1~99s
Working temperature: - 20ºC ~ +55ºC
Wiring: 2 wire, non-polarity
Dimension: 5.2(H)×8.9(W)×0.71(D) inch(Indoor Unit)
6.93(H)×3.54(W)×1.06(D)inch(ush)
8.66(H)×4.69(W)×2.05(D)inch(surface)
* DT-RLC relay actuator is needed for 2nd lock connection.

-15-
13. Hooking Up a Door Release



manual are preserved.
DK4711-41 KIT
FORTECHNICAL SUPPORT CALL
1516-387-6606 FROM 9AM TILL 4PM
MONDAY THRU FRIDAY
OUR WEBSITE WWW.NYWINT.COM
This manual suits for next models
3
Table of contents
Other Nywint Intercom System manuals
Popular Intercom System manuals by other brands

Clear-Com
Clear-Com KB-111A Instruction and service manual

Silvercrest
Silvercrest SFK 16 A1 User manual and service information

urmet domus
urmet domus VOG7 1760/33A manual

Bogen
Bogen CM-206M user manual

Videx
Videx 3000 Series manual

Telegärtner
Telegärtner DoorLine Slim DECT Operating and assembly instructions