Nywint DX-471 User manual


-1-
FW upgrade
Unlock time [03]
Unlock mode [Open]
Auto reboot [Enable]
Reboot
Installer
Call Tune
General
Installer
Wireless
About
Unlock time
08
Step 1. On main menu page, touch the Sng icon, and then touch Installer
item to enter installer page.
Step 2. Select item to set.
Current addtess [01]
Intercom enable Enable
IPC Setting
Monitor list manage
System settings
Installer
Call Tune
General
Installer
Wireless
About

-2-
Unlock time
08
Step 1. On main menu page, touch the Sng icon.
Step 2. Select item to set.
Setting
Ring volume [04]
[35s]
[01]
[01]
Ring time
Door1 calling tune
Door2 calling tune
Setting
Current address [02]
[Disable]Intercom enable
IPC Setting
Monitor list manage
Setting
System settings
[03]
[Open]
FW upgrade
Unlock time
Unlock mode

-3-
01.00
00.01.01
AUTO
[0000]
Divert Memory
01.00
00.01.01
AUTO
Step 1. On main menu page, press (
page.

-4-
Step 1. On main menu page, press (
page.
09
00.00
00.01.00
AUTO
00.00
00.01.00
AUTO
[0000]

-5-
09
Ver:
00.01.00
Addr:
01.10
Video:
AUTO
Ver:
00.01.00
Addr:
01.10
Video:
AUTO
[0000]

-6-
1.6 Set the unlock �me via Monitor DT47MG(V2)
8401~8499 to seconds.
Stge, touch LogoAbout
00:10 DS-1
About
Local Address 00.00
Video Standard
AUTO
System Verson 00.01.00
Display Driver 1.0
Font 1.0
UI 1.0
00:10 DS-1
About
Local Address 00.00
Video Standard
AUTO
System Verson 00.01.00
Display Driver 1.0
Font 1.0
UI 1.0
INSTALLER SETUP
123
_
? + OK: Help Menu
@ + OK: Address Setting Menu
StAboutUNLOCK

-7-
2.1 DT608, DT607, DT601
DT608,DT607,
DT601
DT608,DT607,
DT601

-8-

9

3.2 Power Supply--PS5-24V
PS5 - Power Supply
The PS 5 power supply unit is design for DT system to supply Max. 32
Monitors and Max. 4 Door Stations at the same time, dependingon
different environments.
Universal AC input/full range.
Multi protation: short sircuit, overload, over voltage
Cooling by free air convection
DIN bar mounting.
2. Installation
Fix the PS 5 and DP S and the bar together. Note they MUS T installed
side by side on the DIN bar.
3. Wiring
The PS5 can not be connected to the system directly, it must acompany
with DPS(power supply adaptor), and the power will supply via the non-
polarised bus to the devices over the system. Note that the V- must
connect to the V+ of the DPS, the V- must connect to the - of the DPS.
1. Dimension andTerminal
VADJ
LED
152.5
L ( AC )
N (AC )
V-
V+
1506.5
7824
159
22 117
Unit: mm
L(AC): AC input.
N(AC): AC input.
: Earth Ground.
V-: DC power output.(21.5~26.5 adjustable)
V+: DC power output.(21.5~26.5 adjustable)
VADJ: Output voltage adjustment.
LED: Working state indicatior.
InputVoltage: 85~260Vac, 120~370Vdc
Input Frequency: 47~63 Hz
Leakage Current: >2mA / 240Vac
AC current (TY P.) 1.5A /150Vac, 0.9 A / 230Vac
OutputVADJ range: 21.5~26.5 Vdc adjustable
Rated Voltage: 24Vdc
Rated Current: 3.2A
Rated Power: 76.8W
L ( AC )
N (A C )
G ND
V-
V+
-10-


4. Monitor User Code Setup
4.1 Monitor User Code Setup when work with Villa Door Station
[1] For APT 1, start at 0-15 (switch all DOWN).
[2] For APT 2, start at 16-31 (switch 5 ON).
[3] When use IN-OUT wiring without any distributor, switch 6 ON for last monitor on the line.(see page 2 for the example).
When use Star wiring with distributor, switch 6 ON for every monitor. (See page 3 for the example).
ON(1)
=
OFF(0)
=
ON
1 2 3 4 5 6
Bit-6 line terminal setting:
Bit state Setting Bit state Setting
Monitor not
at the end of
the line.
Monitor at the
end of the line.
-12-
DMR18S, DT608, DT607FE-S3, DT607FE-S4
DMR11S, DMR21,

Bit state User Code Bit state User Code Bit state User Code
Code=1 Code=12 Code=23
Code=2 Code=13 Code=24
Code=3 Code=14 Code=25
Code=4 Code=15 Code=26
Code=5 Code=16 Code=27
Code=6 Code=17 Code=28
Code=7 Code=18 Code=29
Code=8 Code=19 Code=30
Code=9 Code=20 Code=31
Code=10 Code=21 Code=32
Code=11 Code=22
4.2 Monitor User Code Setup when work with Apartment Door Station
The user code of monitors should start from 1-32. Generally one button of door station can call one monitor with the
according address.
ON(1)
=
OFF(0)
=
ON
123456
Bit-6 line terminal setting:
Bit state Setting Bit state Setting
Monitor not
at the end of
the line.
Monitor at the
end of the line.
-13-

RF CARD
L2
L1
DIP Switches
RF CARD
L2
L1
DIP Switches
-14-
5. Wirings for villa and multiple apartments
5.1 Wiring for villa
The 2 wire villa system usually use 1-2 buttons door station, for 1-2 families.
[1] For one button door station, the code address of indoor units start at 0-15 (switch all DOWN).
[2] For two buttons door station, the code address of indoor units start at16-31 (switch 5 ON).
[3] When use IN-OUT wiring without any distributor, switch 6 ON for last monitor on the line.
When use Star wiring with distributor, switch 6 ON for every monitor.

L2
L1
DIP Switches
RF CARD
L2
L1
DIP Switches
-15-
Special One Apartment Connection (1 Master and 1 Slaver)

16
Code=01, DIP6=on
DIP
1 2 3 4 5 6
ON
L2
L1
DIP Switches
SW+
SW-
RING
GND
NC
Code=02, DIP6=on
DIP
1 2 3 4 5 6
ON
L2
L1
DIP Switches
SW+
SW-
RING
GND
NC
Code=03, DIP6=on
DIP
1 2 3 4 5 6
ON
L2
L1
DIP Switches
SW+
SW-
RING
GND
NC
Code=01, DIP6=on
DIP
1 2 3 4 5 6
ON
L2
L1
DIP Switches
SW+
SW-
RING
GND
NC
Code=02, DIP6=on
DIP
1 2 3 4 5 6
ON
L2
L1
DIP Switches
SW+
SW-
RING
GND
NC
Code=03, DIP6=on
DIP
1 2 3 4 5 6
ON
L2
L1
DIP Switches
SW+
SW-
RING
GND
NC
Code=04, DIP6=on
DIP
1 2 3 4 5 6
ON
L2
L1
DIP Switches
SW+
SW-
RING
GND
NC

-17-

-18-

6. Setup for push buttons
6.1 Programming buttons for DT607 series
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
RF CARD
First step, you should remove metal
front panel/cover. Check sketch map on
the right.
Each operation is indicated by the lighting
up of the LED indicator on the unit, and by
the sounding of the buzzer.
The section explains how to program push buttons of door station DT607 series, DMR11S
series, so each button can call corresponding monitor or monitors.
Call button A: Call all monitors in group address from
00~15. (one of the monitor should be set to 00).
Call button B: Call all monitors in group address
from16~31. (one of the monitor should be set to 16).
Call button A: call the monitor with address 01 only.
Call button B: call the monitor with address 02 only.
Call button A: call the monitor with address 01 only.
Call button B: call the monitor with address 02 only.
Call button C: call the monitor with address 03 only.
Call button D: call the monitor with address 04 only.
Call button A: Call all monitors in group address from
00~15. (one of the monitor should be set to 00).
Call button B,C,D: Each all monitors in group address
from16~31. (one of the monitor should be set to 16).
A
B
C
A
B
C
D
RF CARDRF CARD
A A
B
RF CARDRF CARD
1. One-to-many call (by default)
2. One-to-one call
1. One-to-one call (by default)
2. One-to-many call
-19-
This manual suits for next models
4