Evolution Evoflow Storm Eco-V User manual

Evolution Evoflow Pump Manual
POOL & SPA PUMPS
Installation and Operation Manual
Storm Eco-V | Storm | Tuf | Stream
This equipment must be installed and serviced by a qualified technician.
Improper installation can create electrical hazards which could result in property
damage, serious injury or death. Improper installation will void the warranty.
Notice to Installer
This manual contains important information about the installation, operation and
safe use of this product. Once the product has been installed this manual must
be given to the owner/operator of this equipment.
!
WARNING
Evolution Evoflow Pump Manual 8
Evolution Water & Lighting Solutions
Phone: +61 7 5565 0000
Fax: +61 7 5565 0010
Email: enquiries@evolutionwls.com.au
Web: www.evolutionwls.com.au
Address: 27/30 Mudgeeraba Rd,
Worongary QLD 4213 Australia
Evoflow Pump Manual - V1
(W99188EV) 04/2017
ECO-V

Evolution Evoflow Pump Manual 3
1.0 INTRODUCTION
1.1.1 Congratulations on your recent purchase of an Evolution Evoflow Pump. Please
take a moment to read through the entire manual before using the pump. The
pump must be installed and operated as specified.
2.0 SAFETY
2.1.1 The machines mentioned in the manual are specially designed for the pre-filtering
and re-circulation of water in swimming pools.
2.1.2 They are designed to work with clean water at a temperature not exceeding 35
degrees Celsius (95 degrees Fahrenheit).
2.1.3 The installation should be carried out in accordance to the safety instructions of
swimming pools, especially Standard HD 384.7.702, and the specific instructions
for each facility.
2.1.4 The rules enforce on accident prevention should be carefully followed.
2.1.5 Any modification of the pump requires the prior consent of the manufacturer.
Original replacement parts and accessories authorised by the manufacturer ensure
a high level of safety. The manufacturer of the pump assumes no liability for the
damage and injuries caused by un-authorised replacement parts and accessories.
2.1.6 During operation, some parts of the pump are subject to dangerous electric voltage.
Work may only be performed on each pump or on the equipment connected to it
after disconnecting them from the mains power, and after disconnecting the starting
device.
2.1.7 The user should make sure that assembly and maintenance tasks are carried out
by qualified authorised persons and that these persons have first carefully read the
instructions for service and installation.
2.1.8 The operating safety of the pump is only guaranteed if the installation and service
instructions are correctly followed.
2.1.9 The limit values stated in the. Technical table should not be exceeded under any
condition.
2.1.10 In the event of defective operation or fault, contact the technical support department
of the manufacturer or its nearest authorised agents.
2.1.11 If the supply cord is damaged, it must be replaced by an authorised service agent.
Evolution Evoflow Pump Manual 2
POOL & SPA PUMPS
Installation and Operation Manual
Storm Eco-V | Storm | Tuf | Stream
1.0 INTRODUCTION ................................................................................................. 3
2.0 SAFETY .............................................................................................................. 3
3.0 GENERAL INSTALLATION ................................................................................. 4
4.0 ELECTRICAL CONNECTION.............................................................................. 5
5.0 PRIMING ............................................................................................................. 5
6.0 MAINTENANCE .................................................................................................. 6
7.0 TROUBLESHOOTING......................................................................................... 7
ECO-V

Evolution Evoflow Pump Manual 5
4.0 ELECTRICAL CONNECTION
4.1.1 Employ a competent electrician to ensure wiring installation is made in accordance
with any local electrical codes. Every motor requires either a fused disconnect
switch or a circuit breaker.
4.1.2 Check that the information on the nameplate corresponds to the power supply.
4.1.3 A single phase motor has a built in thermal overload switch.
5.0 PRIMING
5.1.1 The pump will prime and re prime providing the hair and lint pot bowl is full of water
and there is sufficient supply from the suction point.
5.1.2 If you lose water from the hair and lint pot bowl it will be necessary to re fill it before
starting.
5.1.3 Remove the clear lid and fill the hair and lint pot bowl with water. Replace the lid
ensuring the o-ring is correctly located and start the pump.
5.1.4 After you have done this allow a few minutes (maximum) for the pump to start
delivering water.
5.1.5 !WARNING: High suction lift or long suction lines will require additional time to
prime and can severely affect the performance of the pump. If the pump will not
prime (flow), repeat step 1 and 2 above.
5.1.6 !WARNING: Mechanical seals if allowed to run dry can be damaged rapidly and
may need to be replaced.
5.1.7 ENSURE that there is always adequate water in the hair and lint pot bowl before
you commence start up.
5.1.8 If you are unable to prime the pump please see the trouble-shooting guide.
5.1.9 Ensure all suction and discharge valves are open before you start the pump,
operating the pump with these valves shut can damage the pump.
Evolution Evoflow Pump Manual 4
2.1.12 This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
2.1.13 The appliance is not intended for use by young children. Young children should be
supervised to ensure that they do not play with the appliance. Cut and fit the pipe
and fittings onto the pump and the Cartridge Filter. REFER to Pump Installation
Manual for correct pump plumbing procedures.
3.0 GENERAL INSTALLATION
3.1.1 The pump must be located as close as practical to the pool. The pump must also
be in a position that enables easy access for periodic servicing.
3.1.2 Care must also be taken to position the pump in an area that is free from flooding in
a well ventilated and dry area (The pump motor cooling fan must have a minimum
clearance of 150mm).
3.1.3 The pump suction line should be not smaller than 40mm (1 1/2”).
3.1.4 The suction line is to have as few bends or elbows as possible. There must not be
an air trap on the suction line.
3.1.5 Use only the pump barrel unions supplied with the pump.
3.1.6 Bolt the pump to the required position (prevent movement).
3.1.7 The pump electrical cable must be wired for the proper voltage and rotation in
accordance with the wiring instructions.
3.1.8 All wiring (electrical) work must be carried out by licensed electricians and must be
installed in accordance to the local codes.
3.1.9 The motor must be grounded.
3.1.10 The weight of the plumbing and fittings is to be independently supported and not
carried by the pump.
3.1.11 The pump motor cooling fan must have a minimum clearance of 150mm.

Evolution Evoflow Pump Manual
7
7.0 TROUBLESHOOTING
SYMPTOMPS
POSSIBLE CAUSE
SOLUTIONS
1. Pump will not
prime
Suction air leak
Make sure water level is correct through suction points.
Ensure baskets and strainers are free of debris. Tighten
all fittings / unions on the suction side of the pump,
remove and replace mechanical seal.
No water in the pump
Make sure hair and lint pot is full.
Closed valves or blocked
lines
Open all valves in system, clean skimmer and pump
basket, check pump impeller of blockage.
2. Motor will not
run
No power to motor
Check that all electrical switches are on. Ensure the circuit
breakers are properly set. Check if timer is set properly.
Check motor wiring at terminals.
Pump jammed
With power switched off turn pump shaft (should spin
freely). If not contact electrician or Evolution for service.
3. Low flow
Dirty filter
Backwash or clean cartridge.
Dirty Skimmer and Pump
strainer
Clean skimmer and pump strainer.
Suction air leak
See 1.
Closed valve or blocked
line
See 1.
4. Motor runs hot
Low or incorrect voltage
Supply to be corrected by Electrician.
Motors run hot to touch and is normal. Thermal overload
protector will function to turn them off if there is an
overload or high temperature problem.
Cooling fan clearance
The pump motor cooling fan must have a minimum
clearance of 150mm.
Installed in direct sunlight
Shield from the weather.
Poor ventilation
Do not tightly cover or enclose motor.
5. Noisy pump
operation
Bad bearing
Have electrician replace.
Air leak in suction
See 1.
Suction blockage
Locate and clear blockage.
Foreign matter in impeller
Dismantle pump and remove foreign matter and debris
from around impeller.
Cavitations
Improve suction, reduce suction lift, reduce number of
fittings, increase pipe size, increase discharge pressure
and reduce flow by throttling discharge valve.
6. Motor over
load cut outs
Motor not connected
properly
Have electrician check wiring.
Low incoming voltage
Have electrician check voltage, ensure pump is not running
on an extension cord. Report low supply to authorities.
Over load due to binding in
pump or wrong size
impeller
Contact Evolution for service.
Evolution Evoflow Pump Manual 6
6.0 MAINTENANCE
6.1.1 The strainer basket in the hair and lint pot bowl should be inspected and cleaned at
regular intervals.
1. Remove lid and lift out basket.
2. Remove debris and hose off with clean water if necessary.
3. Inspect the lid gasket, lubricate with SILICON based grease only if needed. If it
is damaged replace.
4. Replace the strainer.
5. Re-prime the hair and lint pot bowl.
6. Correctly locate the o-ring.
7. Replace the lid (hand tighten) only.
8. Switch on pump.
6.1.2 In Climates where the pump may be exposed to frost or freezing, care must be
taken to ensure the pump is protected from damage.
6.1.3 It is recommended that if the pump is not used during this winter period it should be
drained completely. Drain plugs can be supplied for this purpose.
6.1.4 Do not replace the drain plug. Store it in a safe place until you require the use of the
pump. An example would be within the hair and lint pot bowl basket.
6.1.5 If at all possible remove the pump away and store it in a dry location during this
period.
6.1.6 When you re activate the pump ensure all seals and o-rings are in operational
condition, re-grease if necessary (replace) if unsure of condition.
6.1.7 Check that the motor shaft moves freely before re-activation.
SYMPTOM
This manual suits for next models
3
Other Evolution Swimming Pool Pump manuals
Popular Swimming Pool Pump manuals by other brands

Kopec
Kopec 525S Owner's manual & installation guide

Cooper
Cooper T –Series owner's manual

Wayne
Wayne WIP100 Operating instructions and parts manual

Davey
Davey POWER ACE CR 100 Installation and operating instructions

Theralux
Theralux TVS PRO Installation and operation manual

Pentair Pool Products
Pentair Pool Products SuperFlo brochure