Odorox IDU User manual

Odorox® IDU™ - Induct Unit
Distributed By
Bio-Shine dba. OdoroxAir
Owners Manual
190 Summerhill Road | Spotswood NJ 08884 | (732) 25251-9506 ext. 211
www.OdoroxAir.com

TABLE OF CONTENTS
SAFETY INFORMATION................................................................................................................................................................. 1
PACKAGE CONTENTS...................................................................................................................................................................4
INSTALLATION INSTRUCTIONS............................................................................................................................................... 5
OPERATING GUIDELINES .......................................................................................................................................................... 10
CARE INSTRUCTIONS ...................................................................................................................................................................11
OPTIC REPLACEMENT INSTRUCTIONS ...............................................................................................................................12
TROUBLESHOOTING GUIDE......................................................................................................................................................13
SPECIFICATIONS, REPLACEMENT PARTS AND LIMITED WARRANTY................................................................ 14
LIMITED USE END-USER LICENSE AGREEMENT.............................................................................................................17
Table of Contents

Odorox®IDUTM
1
SAFETY INFORMATION
When using electrical equipment, basic safety precautions should always
be followed to reduce the risk of fire, electric shock, and injury to persons,
including the following:
• Read all instructions before using this hydroxyl generator.
• If the generator is covered by a bag or contains packing material when shipped: Remove plastic bag and
packing materials before use.
• To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.
• WARNING! Always turn electrical power o to the unit prior to maintenance or cleaning.
• Use generator only for intended use as described in this manual.
•INDOOR USE ONLY!
• Caution: For General Ventilating Use Only. Do Not Use to Exhaust Hazardous or Explosive Materials and
Vapors.
• DO NOT attempt to repair or adjust any electrical or mechanical components on this unit. Doing so will void
your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by
authorized personnel only.
• NEVER use detergents, gasoline, furniture polish, paint thinner or other household solvents to clean any part
of the generator.
Use this Hydroxyl Generator only for its intended
purpose as described in this Owner’s Manual.
Warning!
Safety Information
PLEASE READ AND SAVE THESE IMPORTANT
SAFETY INSTRUCTIONS.
IMPORTANT SAFEGUARDS

2
Owner’s Manual
SAFETY INFORMATION
Safe Handling and Disposing of Mercury
Mercury is used in the IDU™ device in order to generate the plasma needed to produce UV-C radiation. This
is similar to the use of mercury in many types of commercial, fluorescent light fixtures. As long as the glass or
quartz outer bulb is intact, mercury is contained within the fixture and poses no health hazard. In the event
that an optic breaks, less than 25 mg of mercury could be released. This is much less than what is present in a
commercial thermometer. Liquid metallic mercury is hazardous due to its potential to release mercury vapor. In
humans, approximately 80% of inhaled mercury vapor is absorbed via the respiratory tract, where it enters the
circulatory system and is distributed throughout the body. Short term exposure to 25 mg of spilled mercury does
not pose a health hazard, provided that the source of the mercury is removed promptly. Chronic exposure by
inhalation, even at low concentrations in the range 0.7–42 μg/m3, can cause eects such as tremors, impaired
cognitive skills, and sleep disturbance in workers. The OHSA limit for occupational exposure of elemental
mercury is 0.1 mg/m3. Mercury is also used in most fluorescent light fixtures.
In the event that the device optic light does not function, the optics should be checked to ensure that they are
intact. If the optic is cracked, but not broken, it should be replaced. Cracked optics should be double sealed in
plastic bags and disposed of according to local, approved procedures. In the event that the optic breaks and the
mercury spilled is clean-up should be done immediately according to the following procedure published by the
Environment Protection Agency.
• Evacuate the room for at least 15 minutes
• Do not attempt to clean up the spill with a vacuum
cleaner, mop or broom.
• Dispose of clothing, fabric etc. that has come in
contact with mercury; do not wash.
• Only the individual to clean up the spill should re-
occupy the space.
• Close the doors to the area of the spill and turn
o the HVAC system; open exterior windows and
direct room air out of the window with fans or use
an exhaust fan if the area is equipped with one that
vents directly outdoors.
• Cover shoes with disposable foot covers or wear
shoes that will be disposed of.
• Remove jewelry as mercury will amalgamate with
metals and ruin them .
• Use a commercial mercury spill clean-up kit to
remove the spilled mercury. (See list of suppliers
on the next page).
•Identify items in the spill area that can be
cleaned and those that cannot. Non-porous
surfaces (finished wood, plastic or concrete)
can be cleaned following this guidance. Porous
surfaces or fabric-covered items (upholstery,
carpeting, stued animals, pillows, backpacks,
unfinished wood, cork, cardboard) are dicult to
clean because mercury beads may be trapped in
these materials. If you decide you cannot clean
these items, place them in plastic trash bags or
cover or wrap them in a double layer of plastic and
carefully seal with tape. Place the wrapped items in
a secure place, preferably outdoors and out of the
reach of children and pets. You should consult with
a trained professional about how to decontaminate
or dispose of these items safely.
•Wear gloves to carefully pick up the larger pieces
of broken glass and what remains of the broken
device and place them on a paper towel. Gently
fold the paper towel around these pieces so you
can pick the bundle up and place it in a zipper-type
plastic bag. Use index cards or sti cardboard to
push smaller pieces of glass and mercury beads
together into a pile. Shine a flashlight at an angle
to locate beads of mercury. The beads will reflect
light from the flashlight. Check for mercury in
cracks or in hard-to-reach areas where beads may
be hidden or trapped. Check a wide area beyond
the spill.

Odorox®IDUTM
3
SAFETY INFORMATION
Mercury Spill Kit Suppliers
Crackle Scientific 800-334-7725
Lab Safety Supply 800-356-0783
Cole-Parmer 800-323-4340
For schools only:
Fisher Scientific 800-452-1261
For schools and businesses only:
Fisher Scientific 800-766-7000
Mallinckrodt/Baker 800-582-2537
Sigma Aldrich 800-325-3010
VWR Scientific 800-932-5000
•Use the eyedropper to collect mercury beads
and place them in the plastic bag. Hold the
eyedropper at an angle to draw the mercury into
the tip. Keep the eyedropper at an angle to stop
the mercury from rolling back out until you can put
the mercury into the plastic bag. Wrap tape (sticky
side out) around your gloved fingers and carefully
use it to pick up any remaining glass or beads.
Check again with the flashlight to be sure that no
beads of mercury remain.
• At this point, mercury beads may still be trapped
in cracks or crevices on irregular surfaces. Sprinkle
sulfur powder over the contaminated area and
rub it gently all over the surface and into the cracks
with a paper towel. Sulfur powder binds with
mercury. Use a paper towel dampened with water
followed by wiping with another damp paper towel
to clean up the sulfur and mercury. Place the used
paper towels in a zipper-type plastic bag.
•Put all the items that were used to pick up the
mercury, including index cards or cardboard,
eyedropper, contaminated tape, paper towels,
and zipper-type bags into the trash bag. Carefully
remove rubber gloves by grabbing them at the
wrist and pulling them inside out as they come o.
Place the used gloves in the trash bag.
•Carefully seal the trash bag that contains the
mercury-contaminated waste and put it in a
secure place, preferable outdoors and out of reach
of children and pets until it can be disposed of
safely.
•If possible, open a window and use a fan to
ventilate the area to the outdoors for 24-48
hours before resuming normal use. If possible, heat
the area (for example, with a space heater) while
still ventilating to the outdoors. Avoid blowing
the exhaust back indoors or into other nearby
residences.
•Clothes or shoes that did not come in direct
contact with liquid mercury should be removed
and put into the trash bag that was left outside
the contaminated area at the beginning of the
cleanup. Close the trash bag and take it outdoors.
Carefully remove the shoes and or clothing
from the trash bag and air them out thoroughly
outdoors for 24 to 48 hours. After the outdoor
airing, items that are washable can then be
laundered.
•Dispose of contaminated items properly!
Mercury-contaminated items should not be placed
in the regular household trash. Contact your town
or county ocials for information about hazardous
waste disposal in your community.

4
Owner’s Manual
PACKAGE CONTENTS
1) One Odorox® IDU™ Hydroxyl Generator Unit
2) One IDU02MD13A Duct Reinforcement Plate, Outside
3) One IDU02MD14A Duct Reinforcement Plate, Inside
4) One 108” GSK-XX-311 Gasket, Rubber & Foam, Adhesive, 3/16” THK, 1/2” W, Gray
5) One Owner’s Manual
Package Contents

Odorox®IDUTM
5
INSTALLATION INSTRUCTIONS
Installation Instructions
Location
The preferred installation location for the Odorox® IDU™ unit is in the return duct as the air will be treated before
the filter and HVAC coil. If it is not possible to install in the return duct, it may be installed in the supply duct. If a
humidifier is present, the IDU should be installed in the air stream before the humidifier. Make sure the location
can be supplied with the necessary power requirements. The IDU™ unit has a power consumption of 96 watts
and requires a 120 / 220 volt, 50/60 Hz power source.
Note: The IDU™ unit is not waterproof. If installing outdoors, the IDU™ unit must be installed in a watertight enclosure.
Important Airflow Information: The Odorox® IDU™ unit must be installed in the air stream in the proper
direction (refer to the Air Flow directional arrows on the side of the reflection chamber). The IDU™ unit can be
installed vertically or horizontally, depending on the duct location.
Odorox® IDUTM Installation
STEP 1: Remove the IDU™ unit from its packaging.
STEP 2: Remove the optics from the packaging material. The optics are fragile, use extreme care. Do not touch
the glass on the optic with bare hands. Handle the optic from the ceramic ends.
STEP 3: Position the optics inside the aluminum chamber. The side of the optic containing the four-pronged
connector must be pushed into the two optic clamps (use caution to ensure the two small white wires do
not get pinched by the clamp). The curved portion of the optic must get pushed into the remaining third
optic clamp.
STEP 4: Connect the wire harness to the optic connector. The wire harness fits in one direction only. If the wire
harness will not connect to the optic, turn the harness 180 degrees.
STEP 5: Remove paper backing from foam gasket on the back of the IDU™ unit and from the duct reinforcement
plate (IDU02MD130).
The light/energy produced from the optics used in this product may
damage if direct exposure to certain plastics and exposed wires. If any
plastic or wires are within the light exposure area, wrap exposed plastic
with aluminum tape and cover wires with metal conduit.

The PYURE Company
3
1
4
1
1
1
6
4
7
4
8
6
2
1
9
1
9
1
5
4
2X
3.750
2X
7.500
3.50
7.00
13.750
8X
.250
4.3138.625
6.00
12.00
6.875
EXISTING DUCT
(METAL OR FIBERGLASS)
1. POWER REQUIREMENT: 120V, 60HZ @ 0.8AMPS.
2.
2 PYURE OPTICS: PART #HG9187-LV33.
NOTES:
CUTOUT DETAIL FOR DUCT: SCALE 1=4
ITEM
NO.
QTY
UOM
PART NUMBER
NOTE
DESCRIPTION
11
EA
IDU02MA02A
UV BOX ASSEMBLY
21
EA
IDU02MA010
CONTROL BOX ASSEMBLY
31
EA
IDU02MD13A
DUCT REINFORCEMENT PLATE, OUTSIDE
41
EA
IDU02MD14A
DUCT REINFORCEMENT PLATE, INSIDE
54
EA
SCR-S8-131
SCREW, PAN HEAD PHILLIPS, M/S, #8-32 X 5/8 IN LG, 18-8 SST
64
EA
WSH-S8-141
WASHER, #8, HI COLLAR L/W, 18-8 SST
74
EA
NUT-S8-116
NUT, HEX, SST, 8-32 THD
86
EA
NUT-S8-306
NUT, ACORN, #8-32 THD, BLACK LUSTER-COATED STEEL
9 108
IN
GSK-XX-311
GASKET, RUBBER & FOAM, ADHESIVE, 3/16" THK, 1/2" W, GRAY
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
HGI INDUSTRIES. ANY REPRODUCTION
IN PART OR AS A WHOLE WITHOUT
THE WRITTEN PERMISSION OF
HGI INDUSTRIES IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
DRAWN
CHECKED
ENG APPR.
MFG APPR.
DATE
NAME
The PYURE Company
SIZE
B
DWG. NO.
REV
UNLESS OTHERWISE SPECIFIED:
0
GREEN TECHNOLOGY AT WORK
PROJECT NAME
Q.A.
DIMENSIONS ARE IN INCHES AND TOLERANCES:
FRACTIONAL
1/16
ANGULAR: MACH
.25 BEND
1
TWO PLACE DECIMAL
.020
THREE PLACE DECIMAL
.010
INTERPRET GEOMETRIC
TOLERANCING PER: ANSI 14.1Y
DO NOT SCALE DRAWING
TOP ASSEMBLY
IDU02MA00
WEIGHT:
SCALE: 1=4
SHEET 1 OF 1
JDU
6/14/2010
INDUCT DU
6
Owner’s Manual
INSTALLATION INSTRUCTIONS

Odorox®IDUTM
7
INSTALLATION INSTRUCTIONS

8
Owner’s Manual
INSTALLATION INSTRUCTIONS
Return or Supply Air Plenum Installation
STEP 1: Turn o all power to HVAC equipment (lockout and tag).
STEP 2: Use the included template to mark the necessary cutout and holes onto the duct.
STEP 3: Cut out the 7 inch by 12 inch opening (use safety glasses and leather gloves).
STEP 4: Drill the eight quarter inch holes (use safety glasses and leather gloves).
STEP 5: Install duct reinforcement plate (IDU02MD130) on outside of duct.
STEP 6: Route duct reinforcement plate (IDU02MD140) through the opening and position over studs (use
caution to avoid dropping plate inside duct).
STEP 7: Secure duct reinforcement plates by installing four 8-32 nuts and lock washers (provided).
STEP 8: Install the IDU™ unit by routing the aluminum chamber through the opening, and securing to the plate
with four 8-32 screws (provided).
STEP 9: Connect the line voltage as per code to the HVAC EAC terminals or to the blower control. A current
sensing relay or pressure switch may be necessary. Check with the equipment manufacturer.
STEP 10: Remove the power entry access cover on the IDU™ unit. Install connector for the power feed in the 7/8
inch hole. Connect cable/wire as per code and make connections to identified wires for ground, neutral,
and line (see electrical schematic).
STEP 12: Re-install the power entry access cover of the IDU™ unit.
STEP 13: Turn power back on to the HVAC equipment (remove lockout and tag).
TM

Odorox®IDUTM
9
INSTALLATION INSTRUCTIONS
NOTE: The IDU™ unit must be hardwired into the HVAC system. Connect to the HVAC EAC terminals or to the blower control.
A current sensing relay or pressure switch may be necessary. Check with the equipment manufacturer.
Neutral
Line 1
Line 1
Line 2
Dedicated
120 Volt, 60 Cycle,
15 Amp Circuit
Mini HVAC
Blower Control
208 Volt, 60 Cycle
Current Sensing
Relay C/W Adjustable
Setpoint
(Example: CR Magnetics CR4395)
Example of Control Circuit for IDU™
Using a Current Sensing Relay
Odorox® IDU™

10
Owner’s Manual
OPERATING GUIDELINES
Model # Part # Optimal Treatment Area
IDU™ - IDU02 model 0819355020300 300 ft² - 1,000 ft²
(27.8 m2 - 92.9 m2)
IDU™ - IDS02 model 0819355020324 1,000 ft² - 1,700 ft²
(92.9 m² - 157.9 m²)
IDU™ - IDB02 model 0819355020331 1,700 ft² - 3,000 ft²
(157.9 m2- 278.7 m²)
The IDU™ series comes in three models, based on the volume of the treatment space (floor area and ceiling
height), the air exchange rate (air changes per hour), and the amount of air that is recirculated through the
system relative to the introduction of fresh air. The table below summarizes the optimal treatment area for each
model, assuming 2 air changes per hour (ACH), 85% recirculated air and 9 foot (2.7 m) ceilings. The guidelines
should be adhered to in order to ensure optimal performance and safety.
Note: if the air changes per hour are higher than 2, the recirculated air is less than 85%, or the ceilings are higher than 9 feet,
the areas listed in the table above will be smaller. If your conditions are considerably dierent, please contact customer
support for additional guidance.
The IDU™ series can be used in medical, senior living, oce, retail and
other commercial, scholastic or hospitality use. It is equipped with two
hydroxyl generating optics, designed for continuous operation when
inserted in a duct and operates using less than 120 Watts (refer to
specification page for additional ratings).
Operating Guidelines

Odorox®IDUTM
11
CARE INSTRUCTIONS
Caution: DISCONNECT the unit from an electrical power source
before performing any maintenance or cleaning on the unit.
Care Instructions
SYSTEM CASE CLEANING
Exterior
The exterior of the Odorox® product can be cleaned with mild dishwashing detergent and a clean cloth, and then
rinsed with clean water. DO NOT use any all-purpose cleaners with harsh detergents or abrasives, as these may
damage the decals and the exterior finish. Care should also be taken to avoid spraying or otherwise directing
detergent or water into or around electrical components.
Interior
The interior of the Odorox® product can be cleaned in the same manner as the exterior.
OPTIC CLEANING
Cleaning of the optics is recommended to maintain peak processing eciency. Fingerprints, smudges, dirt, dust
particles, etc. will interfere with the hydroxyl production and should be avoided.
Note: Remove the optics from the optic chamber prior to cleaning to avoid any damage to the optics during the cleaning
process (refer to the Optic Replacement Instructions and Safety Information for proper removal).
To clean the optics, use a solution of 10% Isopropyl Alcohol and 90% filtered/distilled water on a clean lint-free
cloth and wipe gently. Do not use any type of commercial glass cleaner. Using another lint-free cloth, gently
wipe the optic until completely dry. Allow the optic to dry completely before operating the system.

12
Owner’s Manual
OPTIC REPLACEMENT INSTRUCTIONS
Warning: DISCONNECT the unit from the electrical power source
before performing any maintenance or cleaning on the IDU™ Unit.
Caution: Optics contain Mercury. Read and follow the Safety
Information on pages 2 and 3 of this manual when handling the
optics in the IDU™ unit.
Optic Replacement
Instructions
STEP 1: Turn MAIN POWER switch to the OFF position
STEP 2 – Disconnect power from the IDU™ unit
STEP 3 – Remove optics following these instructions:
Caution: Use clean powder free latex gloves and eye protection when handling the optics in this unit
• With a firm grip on the upper porcelain end of the optic, use your other hand to grip the optic connector.
• Gently ‘wiggle’ connector while pulling from the optic base.
• Gently pull the optic from the three optic support clips (Do not put any pressure on the side of the optic
without support).
STEP 4 – Install new optic following these instructions:
• Remove new optic from packaging and gently insert into the three optic clips.
• With a firm grip on the upper porcelain end of the optic, use your other hand to grip the optic connector.
• Gently connect the optic connector to the optic.
Note: Optic connector is keyed with the optic base and will connect in one direction only
• Ensure optic connector and optic base are firmly pressed together.
STEP 5 – Re-install the IDU™ unit inside the duct.
STEP 6 – Reconnect power to the IDU™ unit.
STEP 7 – Test unit for proper operation.

Odorox®IDUTM
13
TROUBLESHOOTING GUIDE
Troubleshooting Guide
Problem Possible cause Solution
OPTIC 1 or OPTIC 2
indicator light will
not light up
MAIN POWER switch is in the
OFF position.
Turn on MAIN POWER switch to the
ON position.
Optic has failed. Contact local distributor for service.
Blue LED has failed. Contact local distributor for service.
Internal component failure. Contact local distributor for service.
Optic not functioning
Rated life of optic has been met. Contact local distributor for
replacement optic service.
Optic has been damaged. Contact local distributor for
replacement optic service.
Internal component failure. Contact local distributor for service.

14
Owner’s Manual
SPECIFICATIONS, REPLACEMENT PARTS AND WARRANTY
Specifications
Replacement Parts
Limited Warranty
Dimensions (LxWxD):
Weight:
Voltage:
Power:
Control:
Meter:
Number of Optics:
Shipping Dimensions:
Shipping Weight:
14.50” x 9.63” x 14.35” [368mm x 245mm x 365mm]
13.47lbs [6.11kg]
100 – 240 VAC 50/60Hz
100 Watts (Nominal) | 195 Watts (Max)
MAIN POWER Selector Switch & OPTIC High/Low Switch
Hour Meter
2
16.00” x 16.00” x 16.00” [407mm x 407mm x 407mm]
17.50lbs [7.94kg]
For replacement parts, warranty service, or any questions regarding the operation and maintenance of your
Odorox® product, please contact your local Odorox® distributor. To find a distributor in your area, please visit:
www.pyureco.com/contact or www.odorox.com/contact
The PYURE Company, Incorporated warrants that this Odorox® product (excluding spare parts and consumables)
shall be free from defects in workmanship or materials for a period of two (2) years from the delivery thereof to
the customer.
EAN number PYURE part # Part description
0819355021147 OPT-XX-176 Hydroxyl Generating U-Optic Lt Blue
0819355021154 OPT-XX-177 Hydroxyl Generating U-Optic White
0819355021130 OPT-XX- 078 Hydroxyl Generating U-Optic Brown
XSA00MA10 Ballast Assembly - International
EPC-HM-027 Hour Meter
EPC-IL-180 LED, 5mm Blue

Serial #:
From:
Model #:
Date of Purchase:
Vendor Name:
PLEASE KEEP THIS PART FOR YOUR RECORDS
The PYURE Company
2055 High Ridge Road
Boynton Beach, FL 33426
The PYURE Company
2055 High Ridge Road
Boynton Beach, FL 33426
Complete below and reverse side. Tear along perforation
and mail to The PYURE Company within 60 days of purchase.
You may also visit www.pyureco.com and register your warranty on-line.
Place
Stamp
Here
(561) 735-3701 www.pyureco.com

Purchaser’s Name:
Vendor’s Name:
Address:
Vendor’s Address:
City:
ZIP/Postal Code:
Purchaser’s Type of Business:
Primary Use for Machine:
Model Type: Serial #:
State/Prov:
The PYURE Company (“PYURE”) warrants that the product set forth below will be free from defects in materials and
workmanship for the period of two (2) years from the date of original purchase under the following terms and conditions:
To obtain service under this warranty, send or deliver this product within the warranty period together with the warranty
certificate to any PYURE regional oce or PYURE authorized warranty service center. If requested, by PYURE or an PYURE
authorized service center, you must present proof of purchase showing date and place of purchase. If upon inspection by
PYURE or an PYURE authorized warranty service center, the product is proved to be defective, it will be repaired without
charge using, if necessary, new parts or comparable used parts that have been fully reconditioned and returned to you. The
warranty period for replacement parts shall extend for a period of six (6) months following the installation of same or for the
remaining period of this warranty whichever is longer. This warranty card does not apply in the following cases: (a) damage
to product due to mishandling, alteration, failure to follow operation, maintenance or environmental instructions prescribed
by applicable instruction manual or shipping damage; (b) damage caused during service performed other than PYURE or
an PYURE authorized service center; (c) if the product has had its serial number(s) or other identifying data removed: or
(d) damage, defect or unsatisfactory performance caused by the use of equipment not manufacturered or distributed by
PYURE. IN NO EVENT WILL PYURE BE LIABLE FOR ANY DAMAGE, INCLUDING INCONVENIENCE, LOST PROFITS, OR LOST
SAVINGS, OTHER INCIDENTAL DAMAGE STEMMING FROM THE USE OF THE PRODUCT OR OUT OF DEFECTS THEREIN,
OR BY BREACH OF THIS EXPRESSED WARRANTY OR ANY IMPLIED WARRANTY WITH THE RESPECT OF THIS PRODUCT,
WHETHER ON ACCOUNT OF NEGLIGENCE OR OTHERWISE, EVEN IF PYURE OR AN PYURE AUTHORIZED WARRANTY
SERVICE CENTER HAS BEEN ADVISED OF THE POSSIBLITY OF SUCH DAMAGES.
Some states or provinces do not allow limitations on how long an implied warranty lasts or limitations of incidental or
consequential damages, so the above limitations may not apply to you. This warranty gives you specific legal rights and you
may also have other rights which vary from state to state or province to province.

Odorox®IDUTM
17
Limited Use End-User License Agreement
This End-User License Agreement (EULA) is a legal agreement between you (either an individual or a single
entity) and the mentioned owner (The PYURE Company) of any computer software which may include
associated firmware, media, printed materials, and “online” or electronic documentation (“Licensed PYURE
Software”).
By installing, copying, or otherwise using the Licensed PYURE Software, you agree to be bounded by the terms
of this EULA. If you do not agree to the terms of this EULA, do not install or use the Licensed PYURE Software in
the Odorox® product.
Licensed PYURE Software.
The Licensed PYURE Software is protected by U.S. and international copyright, patent, trade secret laws and well
as other international intellectual property laws and treaties. Upon your acceptance of this EULA, The PYURE
Company grants to you a nonexclusive, revocable license to use the Licensed PYURE Software, provided that
you agree to the following:
1. Grant of License.
The Licensed PYURE Software is licensed, not sold. You own a copy of any media or hardware on which the
Licensed PYURE Software is shipped, but not a copy of the Licensed PYURE Software itself. The PYURE
Company retains all title, copyrights, and other intellectual property rights in the Licensed PYURE Software and
any copies thereof. You may use a copy of the Licensed PYURE Software with any Odorox® product for which
you have accepted the terms of this EULA.
2. Restrictions.
You must maintain all notices including copyrights on all copies of the Licensed PYURE Software. You may not
modify, adapt, translate, reverse engineer, decompile, disassemble, or otherwise attempt to learn the source
code of the Licensed PYURE Software, except and only to the extent that such activity is expressly permitted by
applicable law notwithstanding this limitation.
3. Termination.
Your rights under this EULA terminate upon your termination of this EULA, or without prejudice to any other
rights, The PYURE Company may terminate this EULA if you fail to comply with its terms and conditions. In such
event, you must destroy all copies of the Licensed PYURE Software.
4. No Software Warranty Independent from Other Warranties.
The Licensed PYURE Software is being delivered to you “AS IS” and The PYURE Company makes no warranty as
to its use or performance, other than any the “Limited Warranty” on the Odorox® product described above.
5. LIMITATION OF LIABILITY.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE PYURE COMPANY
OR ITS SUPPLIERS BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES
LIMITED USE END-USER LICENSE AGREEMENT

18
Owner’s Manual
OR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, LOSS OF SAVINGS, OR ANY OTHER
PECUNIARY LOSS) ARISING OUT OF THE USE OF OR INABILITY TO USE THE LICENSED PYURE SOFTWARE
PRODUCT, OR FOR PROVISION OF OR FAILURE TO PROVIDE SUPPORT SERVICES, EVEN IF THE PYURE
COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
THE ENTIRE LIABILITY OF THE PYURE COMPANY AND YOUR EXCLUSIVE REMEDY UNDER THIS EULA IS,
AT THE OPTION OF THE PYURE COMPANY, CORRECTING OR WORKING AROUND ERRORS, REPLACING
THE MEDIA, OR REFUNDING THE PURCHASE PRICE. IN NO EVENT SHALL THE PYURE COMPANY’S ENTIRE
LIABILITY UNDER THIS EULA EXCEED THE PURCHASE PRICE (EVEN IF THE LICENSED PYURE SOFTWARE
PRODUCT IS DOWNLOADED WITH OTHER THIRD PARTY SOFTWARE FREE OF CHARGE) OF THE LICENSED
PYURE SOFTWARE PRODUCT.
6. Miscellaneous.
This EULA is governed by the laws of the State of Florida, U.S.A., and jurisdiction for any action based on the
Licensed PYURE Software shall lie in a court located in Palm Beach County Florida. If any part of this EULA is
found void and unenforceable, it will not aect the validity of the balance of the EULA, which shall remain valid
and enforceable according to its terms. Should you have any questions concerning this EULA, or if you desire to
contact The PYURE Company for any reason, please visit: www.pyureco.com/contact.
LIMITED USE END-USER LICENSE AGREEMENT
Table of contents
Other Odorox Inverter manuals
Popular Inverter manuals by other brands

Bosch
Bosch c-Si M 48 EU Installation and operation guide

SHENZHEN ENCOM ELECTRIC TECHNOLOGIES CO.
SHENZHEN ENCOM ELECTRIC TECHNOLOGIES CO. EDS780 Series user manual

Pentax
Pentax FCP Series Operation and Maintenance Handbook

CyberPower
CyberPower CPS1000EI user manual

Tektronix
Tektronix TR 503 instruction manual

Solplanet
Solplanet ASW T Series user manual