© 2020 OJ Electronics A/S© 2020 OJ Electronics A/S 5
MTD3 Instructions
1. TECHNICAL SPECIFICATIONS
Control pollution degree....................................................................................2
Software class.................................................................................................. A
Built-in circuit breaker .....................................................................2-pole, 16 A
Enclosure rating.......................................................................................... IP 21
Overvoltage category .......................................................................................III
Rated impulse voltage................................................................................. 4 kV
Ball pressure temperature (TB)..................................................................125°C
Voltage.......................................................................... 230 V AC ± 10%, 50 Hz
Max. prefuse................................................................................................ 16 A
Output ................................................................................................ Max. 16 A
Output relay............................................................. Make contact - SPST - NO
Output applications................................Resistive load 16 A Inductive load 1 A
Terminal wire size ..........................≤ 13 A - 1.5 mm2, > 13 A to 16 A - 2.5 mm2,
solid core wire
Method of mounting...................................................................Flush mounting
Dimensions............................................................................... 84 mm x 84 mm
Build-in depth.......................................................................................... 20 mm
Sensor type ..........................................................................NTC 12 kΩ @ 25°C
Max. sensor extension ............................................................................... 10 m
Temperature range .............................................................................. +0/+40°C
Control principle.................................................................................... ON/OFF
Purpose of control............................Thermostat for electric underfloor heating
Design of control ................................................................................... PWM/PI
Type of action................................................................................................ 1.B
Standby power....................................................................................... < 0.5 W
Display.................................................................................................. Segment