manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. OKE
  6. •
  7. Temperature Controllers
  8. •
  9. OKE OKE-2012 User manual

OKE OKE-2012 User manual

OKE-2012
oke-2012 user manual V19-9 en.PDF
2 3
1
4
65
Low Temp.
Error
High Temp.
Error
92, 1277bungil, Jungangdae-ro, Dongrae-go,
Busan, South Korea
TEL +82 51 5066428 / FAX +82 51 5076430
E-mail : [email protected]
Homepage : www.swoke.co.kr
User Manual
Temperature Controller
☞Before operating this controller, highly recommended for you
to read this manual carefully without fail.
※ Notandum for safety
‘Please keep the caution for safety rule to use product correctly
and prevent from accidents or potential threat. The notandum
will give 2 options such as “Warning” & “Caution”
Ignoring this symbol could
lead to serious injury or death,
if equipment is handled in
wrong way
!Waring
Ignoring this symbol could lead
to slightly injury or damage to
the product, if equipment is
handled in wrong way
!Caution
1. Must set the fail-safe function system when it will install to
control special equipment which will seriously effect a loss of
lives/properties (atomic energy control, medical device,
vehicle,/train/airplane combustion device, recreation/safety
device, etc.).
2. Must set with attaching at panel. Highly concerns an electric
shock.
3. With power ON, please don’t try to connecting/ repairing/
maintenance. Highly concerns an electric shock
4. Please make sure the terminal number when connect to power.
Highly concerns fire hazard.
5. Only authorized staffs (maker) can reorganize/ reconstruct the
products. Otherwise concerns fire hazard/ electric shock
1. Prohibited to use at outdoor. Otherwise will cause the short
durability of product and concerns a fire hazard.
2. Please use the product within specification ranges. Otherwise will
cause the short durability of product and concerns a fire hazard.
3. Please do not using with over-loaded power at the relay switch
connection. It will cause an error of disconnection/ fire hazard/
relay destroy.
4. Please avoid using the water, organic solvent when it cleaning.
Only use dry towel. It concerns an electric shock & a fire hazard.
5. Please avoid installing at the Inflammable gas/ explosive gas/
direct ray of light/ radiant heat/ vibration/ impact area. It
concerns a fire hazard & explosion.
6. Please keep the product clean & dry without dust/ wire
leftover/etc. it concerns a fire hazard / an operating error
!Waring
!Caution
Panel Display description
1.Relay operating indicator
2.Emergency indictor
3.Up button
4.Down button
5.SET mode button
6.FND display (Blink during
Temp. set)
Size & Dimension
Terminal Connection Diagram
Panel attachment Process
Error Code & Reasons
Temp. sensor
short-circuit
Temp. sensor
disconnect
Operation
machine Relay
Relay
AC 250V 2A
oke-2012 user manual V19-9 en.PDF
User mode function Setup
User mode function
Function Temp.
Display Operating range Maker
value
Operating Temp.
setup 10.0 LSP∽HSP 10.0℃
1. Press “SET” button shortly.
2. After adjust Temp. with Up / Down button, press “SET” button.
3. Save the new Temp. and complete the setup.
Setup process
Function Display Operation range Maker value
Max.Temp set
HSP
-40.0 ∽99.9℃ 99.9℃
Min.Temp. set
LSP
-40.0 ∽99.9℃ -40.0℃
Output
Delay-time
dlt
0∽9 분 0 분
Output
deviation
dif
0.1 ∽9.0℃ 1.0℃
Output Temp.
correction
Cor
-9.9 ∽+9.9℃ 0.0℃
Output mode
typ
C(Cooling)∽H(Heating) C(Cooling)
Emergency
operating time
SCL
ON time ∽ OFF time autosave
Master Mode function Setup
※ Emergency operating mode function setup ※
1. (Emergency operating (SCL)) : When the temp sensor is not stable, the temp
control function will transfer automatically to timer control function, and it
will work the current temp control system as close as possible.
2. (emergency operating time) when it return to normal operating system after
first time or initialized emergency operating time , it will store the operating
time after calculating the average time based on 3 times of relay ON/OFF.
During calculating the average time, “1 indicate” will blinking as below
picture and will turn off the indicate when it completed the time (once the
emergency operating time is stored, it will remain even if power is off)
3. (emergency operating confirm) when emergency operating is in activating,
the “2 indicate” as below picture will ON and display “AUt” with blinking at
temp display window. In order to confirm the ERROR message, it should be
initialized the emergency operating time.
4. (emergency operation time confirm) after one time press the “SET” button, it
can reconfirm the time thru press “↑” button will display “relay ON time”
and press”↓” button will display “relay OFF time”
5. (Initialize the emergency operating time):
a. when press over 5 seconds “↑” or “↓” button, time will complete the
initialization.
b. initialing with net Output mode.
c. initializing with new set temp..
Emergency lamp indicator
Emergency recoding indicator
After converted to “HSP” mode, press
“SET” button.
Adjust with Up / Down button, press
“SET” button
After converted to “LSP” mode, press
“SET” button
Return to normal Temp. display
mode
Press “SET” button during 5 seconds,
then convert to master function mode.
Adjust with Up / Down button, press
“SET” button
After converted to “dlt” mode , press
“SET” button
Adjust with Up / Down button, press
“SET” button
After converted to “dif” mode, press
“SET” button
Adjust with Up / Down button, press
“SET” button
After converted to “Cor” mode, press
“SET” button
Adjust with Up / Down button, press
“SET” button
After converted to “typ” mode, press
“SET” button
Adjust with Up / Down button, press
“SET” button
After converted to “SCL” mode, press
“SET” button
Adjust with Up / Down button, press
“SET” button during 5 seconds
Master Function mode setup process
Specification
Control Output range depend on Output
deviation setting ( Cooling mode )
SET
Temp.
10℃
Output ON
Output OFF Output OFF
Output ON
➢Operation range : -55.0℃~99.9℃
➢External size (mm) : 76(W) x 34(H) x 75(D)
➢Cutting size (mm) :70(W) x 30(H)
➢Delay time : 0 ~ 9 MIN (1min/unit)
➢Correct Current Temp. : -9.9~+9.9℃(0.1℃/units)
➢Input sensor : NTC (5KΩ25℃) sensor
➢Sensor accuracy : 1 %
➢Power supply : 230VAC 50/60Hz
➢Power Consumption : Aver. 5VA ↓
➢Ambient temp./ Humidity : 0℃~50℃/ 80% ↓
➢Output : 1 relay ON/OFF (250VAC 2A)
➢Output deviation : 0.0℃~9.0℃(0.1℃/units)

Popular Temperature Controllers manuals by other brands

Selec PID500 operating instructions

Selec

Selec PID500 operating instructions

Sorel TDC 1 Installation and operating instructions

Sorel

Sorel TDC 1 Installation and operating instructions

Kampmann 30277 operating instructions

Kampmann

Kampmann 30277 operating instructions

S+S Regeltechnik THERMASGARD RSTF Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik THERMASGARD RSTF Operating Instructions, Mounting & Installation

Omron EJ1 EtherCAT user manual

Omron

Omron EJ1 EtherCAT user manual

Auber SYL-1615 instruction manual

Auber

Auber SYL-1615 instruction manual

Kampmann KaControl Assembly and installation instructions

Kampmann

Kampmann KaControl Assembly and installation instructions

Julabo magnum 91 operating manual

Julabo

Julabo magnum 91 operating manual

Honeywell T4031A Product data

Honeywell

Honeywell T4031A Product data

Ecojay SMartZone-2X Installation, Specification & Operation

Ecojay

Ecojay SMartZone-2X Installation, Specification & Operation

Controlli OmniaPRO STA60L quick start guide

Controlli

Controlli OmniaPRO STA60L quick start guide

Omron EJ1 EtherCAT instruction manual

Omron

Omron EJ1 EtherCAT instruction manual

Velux KRX 100 quick start guide

Velux

Velux KRX 100 quick start guide

Aube Technologies Temperature Sensor AC146-410 installation guide

Aube Technologies

Aube Technologies Temperature Sensor AC146-410 installation guide

ThermoElectric CAL3300 Manual guide

ThermoElectric

ThermoElectric CAL3300 Manual guide

Como Open Therm Installation and operating manual

Como

Como Open Therm Installation and operating manual

iNels RFTC-10/G manual

iNels

iNels RFTC-10/G manual

INSTAT+ 2R7 User and installation guide

INSTAT+

INSTAT+ 2R7 User and installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.