This guide is designed to provide a quick and easy setup of the BV1270SIP-OD-
E&M5 (OD Interface) Internet Voice Gateway. IP address, numbering plan and all
other parameters are for sample purposes only. The guide configures the most
basic required parameters. For more advanced configurations, please refer to the
Installation Guide & Technical Reference
Revision 1.0.0.1 Copyright 2006
Oki Electric Industry Co., LTD.
4-10-16 Shibaura Minato-ku, Tokyo 108-8551, Japan
Te: +81-3-3454-2111
http://www.oki.com

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 3 of 33
IMPORTANT SAFETY INSTRUCTIONS
Warning
This warning symbol means danger. You are in a situation that could cause bodily injury. Before
you work on any equipment, be aware of the hazards involved with electrical circuitry and be
familiar with standard practices for preventing accidents.
INSTRUCTIONS
1. Read the installation instructions before connecting the system to the power source.
2. Only trained and qualified personnel should be allowed to install, replace, or service this
equipment. This equipment must be installed
and maintained by service personnel as defined by EN60950. Incorrectly connecting this equipment
to a general-purpose outlet could be hazardous. The telecommunications lines must be disconnected:
1) before unplugging the main power connector or ;
2) while the housing is open, or both.
3. For connections outside the building where the equipment is installed, the following ports must
be connected through an approved network termination unit with integral circuit protection. Before
performing any of the following procedures, ensure that power is removed from the DC circuit. Do
not work on the system or connect or disconnect cables during periods of lightning activity.
4. To avoid electric shock, do not connect safety extra- low voltage (SELV) circuits to telephone-
network voltage (TNV) circuits. LAN port contains SELV circuits, and telephone ports contain
TNV circuits.
Hazardous network voltages are present in telephone ports regardless of whether power to the unit
is OFF or ON. To avoid electric shock, use caution when working near telephone ports. When
detaching cables, detach the end away from the unit first.
5. To install the permanently fixed protective earthing during installation, earthing connection in
this product should be directly connected to main supply socket with protective earthing in building
or other specified device.

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 4 of 33
Installation Steps
Step 1
Hardware Installation
1. BV1270SIP-OD to KTS/PBX cables
Step 2
Configuration
1. Unit Information
Check firmware version.
If firmware version is old version,
you should do version up.
2. Create Configuration File
CONFIG.DAT
Set important basic parameters.
3. Create DNS. DAT
Number to IP translation table
Step 3
File Transfer
1. File Transfer
CONFIG.DAT
DNS.DAT
2. Reboot BV1270SIP-OD

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 5 of 33
STEP 1 – HARDWARE INSTALLATION
1.1 Connecting Cables
The following connections must be made to complete BV1270SIP-OD cabling.
• Power Cable
• Ground Cable
• Interface Cables
• RS-232C Cable
• LAN Cable
With the exception of the power cable, all cables must be prepared during the installation process. In
addition, cable restraints should be installed.
Figure 1-1: BV1270SIP-OD Ports
Follow all instructions when performing cabling procedures. Improper installation methods can result
in damage to the BV1270SIP-OD and injury to installation personnel.
There are some possibility to influence the electric wave trouble to other equipment depending on the
connection environment. The ferrite cores are recommended to be installed in Power cable, interface
cable, and LAN cable.

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 6 of 33
Install Power Cable
The power cable is supplied with the BV1270SIP-OD base unit.
To install the power cable:
1. Plug the DC connector on the AC adapter into the power connector located at the rear of the unit
2. Plug the power cable into the AC adapter.
Figure 1-2: Power Cable Attachment
Do not plug the power cable into the power supply outlet.
DC Connector
AC adapter
Power Cable

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 7 of 33
Prepare and Connect Frame Grounding Cable
An Earth to Frame Ground (FG) must be prepared when the unit is installed in a rack assembly.
Prepare Grounding Cable
The following information should be taken into consideration when preparing grounding wires.
• Determine the proper length and prepare Frame Ground.
• Use IV (insulated vinyl) wire that is compatible with the supplied crimp connector (.057 ~ 1.44mm2) e.g.
AWG cross-section 0.8mm2.
• If a crimp connector other than the one supplied with the BV1270SIP-OD unit is to be obtained, use one
that is 1.25-4 for use with a 4mm diameter screw and terminal part width of 8mm or less.
Do not use an angular type connector.
Connect Frame Ground and Signal Ground Cables
All unit chassis must be grounded to a Communication 1 earth ground.
To connect the Frame Ground:
1. Use the terminal screw located at the rear of the base unit and to the left of the power connector to secure one
end of the FG grounding cable.
2. Connect the other end of the frame grounding cable to a protective earth grounding point.
Figure 1-3: Earth Ground attachment
Note
Frame Ground

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 8 of 33
Connect Interface Cables
If pre -manufactured cables are not used cabling the BV1270SIP-OD interface may require the preparation of
line cable connectors for the terminal side of the connection and LAN cable connectors for interconnection with
LAN equipment such as routers and hubs.
The BV1270SIP-OD uses an 8-wire printed interoffice cable (4-wire and 6-wire cable can also be used).
To prepare line connectors for the BV1270SIP-OD unit:
1. Split one end of printed interoffice cable and separate the cable into 8 individual cores.
2. Insert cores into RJ45 connector in accordance with the following diagram.
8
7
6
5
4
3
2
1
1- SG (Signal ground)
2- SS Signal
3- Recieve (PBX→BV1270SIP-OD-E&M5)
4- Send (BV1270SIP-OD-E&M5→PBX)
5- Send (BV1270SIP-OD-E&M5→PBX)
6- Recieve (PBX→BV1270SIP-OD-E&M5)
7- SR Signal
8
- not used
Figure 1-4: BV1270SIP-OD line connector preparation
3. Use a standard RJ connector crimp tool to secure the wires in the RJ connector.
Repeat these steps for each port to be used (maximum of 4), then proceed to the procedure below, “To
connect the analog interface cables” below.
To connect the interface cables:
1. Select a port for the connection and verify that the port numbers to be interconnected with the PBX trunk lines.
2. Connect the prepared cable connector to RJ45 connector (1 through 4) located at the back of the BV1270SIP-
OD.
Line Cable

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 9 of 33

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 10 of 33
Note
3. Connect the other connectorized end of the cable to the PBX or similar remote equipment.
Figure 1-7: Connecting a unit to PBX E&M5 trunk board
To complete the installation, all interface cables should be secured to the cable support bracket. See
Section 0, Install Cable Restraints for details.
RJ45
Terminal Block
E&M Tie
Trunk
Interface
KTS or PBX

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 11 of 33
Install Cable Restraints
After the interface cables have been installed, the supplied cable restraints should be attached so that no stress
can occur at the cable connection points. Use of restraints will prevent accidental disconnection and damage to
cables and units.
To attach cable restraints:
1. Locate the snap band (wire tie) packaged with the BV1270SIP-OD base unit and the cable support
bracket installed at the right side rear of the base unit. (On desktop units the bracket is attached to the unit
chassis.
Figure 1-8: Cable restraint installation
2. Form a loop in the snap band so that the cable being restrained and the cable support bracket hole are
captured.
3. Insert the free end of the snap band through the securing notch located at the opposite end of the snap
band.
4. Pull the snap band end through the notch until proper support is achieved.
Notch
Band

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 12 of 33
Connect Computer with RS-232C Cable
To initialize a newly installed BV1270SIP-OD unit using the Common Maintenance Console Software Unit
Information Setup Wizard, a computer or terminal must be connected directly to the unit using an RS-232C serial
cable (straight-through) with DB9 Female to DB9 Female connectors. The pin configuration for the serial cable is
shown in Figure 1-9.
Figure 1-9: RS-232C pin configuration
To connect the computer with the BV1270SIP-OD unit:
1. Turn the computer power OFF.
2. Connect the RS-232C cable to one of the computer’s com ports (e.g. Com 1) and to the Serial Port
connector on the BV1270SIP-OD front panel as shown in Figure1-10
DB9 Female
DB9 Female

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 13 of 33
Note
The Common Maintenance Console Software is configured for serial communications on the port Com 1. If
a port other than Com 1 is to be used, the CMCS serial communications parameter must be reconfigured.
See Section 5.7.1 for details.
Figure 1-10: BV1270SIP-OD serial port connection
Notes: The connector of Serial Port is especially influenced by static electricity. Please do not
remove a dust cap except the connection of maintenance console.
Serial poll connector
PC computer

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 14 of 33
Note
Connect the Network Cable
A standard 10/100BaseT cable with an RJ45 connector is used to interconnect the BV1270SIP-OD unit with a
network device.
To install the Network connector cable:
1. Insert the RJ45 connector into the BV1270SIP-OD LAN port located on the unit’s rear panel.
Figure 1-11: Uplink connector location
2. Connect the other end of the 10/100BaseT cable to the remote LAN equipment (e.g. router, Ethernet
switch, or hub.)
When connecting the BV1270SIP-OD directly to a router use a 10BaseT Cross/Rollover cable. Use a
10/100BaseT straight cable to connect the BV1270SIP-OD to a hub or Ethernet switch.
Figure 1-12: Router and Ethernet Switch cabling
As cable lengths increase voice quality may become degraded. Line repeaters can be used when long
cable lengths are required. Voice quality may also deteriorate when hubs are connected in tandem and
tandem arrangements should never exceed more than three stages.
LAN Cable
Router
Router
Ethernet Switch
BV1270SIP-OD
BV1270SIP-OD
10/100 BaseT straight cable
10/100 BaseT straight cable

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 15 of 33
Note
Power-Up the BV1270SIP-OD and Verify
Operation
Once all connections have been made, the BV1270SIP-OD can be set to its power-ON condition. After the unit is
powered-up, power should only be returned to the power-OFF state for installation or hardware maintenance
activities.
Also, during the power-up process, several state indicators can be viewed to assure that the unit is operating
properly.
To turn the BV1270SIP-OD power on:
1. Check that all cables are properly connected.
2. Plug the power cable into the power supply outlet.
Figure 1-13: Power switch and front panel indicators
To verify proper operation, observe the following during the POWER ON process.
When the power cable is plugged into the power supply outlet, check for the following indications:
• Power, Online, Alarm, and Busy lamps light up during the initialization process.
• The Alarm and Busy lamps turn off following initialization and the Power and Online lamps remain lit.
If the Alarm and/or Busy lamps remain lit for more than five minutes, turn the unit power OFF and contact
an authorized Oki representative.
A steady alarm lamp indicates that the built-in clock battery has been discharged and the time parameter
is no longer synchronized. This can occur if the unit is left without power for more than two months. This
condition will cease once the clock is recharged and reset. This generally takes about 10 minutes. See
Section 5.11 for the Common Maintenance Console Software clock reset procedure. IF he BV1270SIP-OD
is connected to the Ethernet network, the "Link" lamp will also light up.
Notes: Although the “Link” lamp may repeat lighting and no lighting under the
influence of magnetic field or noise, there is no problem in no lighting for several
seconds without disconnect phone call etc. When such state occurs, please keep
away BV1270SIP-OD from a noise generation source etc.
POWER lamp
Al ARM lamp
ONLINE lamp
LINK lamp BUSY lamps 1-4

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 16 of 33
Powering-Down the BV1270SIP-OD
It is sometimes necessary to turn the BV1270SIP-OD unit OFF. This is the case for instance during some forms of
maintenance or when relocating the unit.
To turn the BV1270SIP-OD power OFF, pull up the power cable from the power supply outlet.
Carry out office data setting process described in STEP2: Logical Installation

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 17 of 33
STEP 2 – Part 1 Unit Information
This guide follows an example network configuration and numbering plan.
Please request correct information for your deployment from your network administrator.
1. This guide will refer to the above IP information.
•
IP address for BV1270SIP-OD : 172.17.68.121
• Subnet Mask forthe network : 255.255.255.0
•
Gateway IP address : 172.17.68.1
2. Connect the BV1270SIP-OD and PC with an RJ45 Ethernet straight cable via a hub. Alternativelyyou can connect a
BV1270SIP-OD and PC directly by an RJ45 Cross Connect (rollover) cable.
3. Connect the PC to BV1270SIP-OD using the Serial RS232C cable.
Set the COM port settings to: 9600bps, 8 data bits, 1 stop bit, no parity & Hardware control
4. Please note:
• By default the Maintenance Console Software attempts to use the COM1 port of the PC.
To change the default com port goto the menu bar item “Tools” select “Options”set the com port for your system.
• Assign an IP address to the PC, which falls within the same subnet to enable LAN communication
GW Addr: 172.17.68.1
Subnet: 255.255.255.0
Router
Hub/Switch
Telephone
OKI BV1270SIP-OD E&M5
IP Addr: 172.17.68.121
Subnet: 255.255.255.0
RS-232C Cable
Win2K, WinXP PC
IP Addr: 172.17.68.130
Subnet: 255.255.255.0
RJ45 Ethernet
Straight cable
(408) 935-3334
(408) 935-3333
(408) 935-3332
(408) 935-3331
PSTN Network
PBX

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 18 of 33
Step 1
Execute IVG MCS on the computer connected to the
BV1270SIP-OD OD unit
IVG Maintenance Console Software startup Flash screen
Step 2
Enter “mcs” - the default password
Click “OK”
Case-sensitive password
Step 3
Click on the “Main” folder in the left window.
Right-click mouse and select “New Group”
Step 4
Enter Group Name “New Network”
Comment “Sample Configuration

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 19 of 33
Step 5
Click on “New Network”
Right-click mouse and select “New Gateway”
The Setup Wizard screen (1 of 6) will appear.
Step 6
New Gateway Setup Wizard
Enter name “BV1270 OD”
Select Unit “BV1270GW”
Select Version “C1.0” *Note
Select Interface “OD”
Note: Always select the FW version installed on your BV1270SIP-OD
Firmware version of B BV1270SIP-OD should be t
he latest
version.
(Reference the BV1270SIP-OD Installation Guide for more information.)
Enter Comments “San Jose Office”
Click “Next”
Step 7
Enter IP Address information*Note
IP Address 172.17.68.121
Subnet Mask 255.255.255.0
Gateway Address 172.17.68.1
Reference the diagram on page 8.
Click “Next”
Note: Be acurate when entering the IP information as erroneous entries will cause problems.

BV1270SIP-OD OD Quick Start Guide Oki Electric Industry Co.,Ltd.
Page 20 of 33
Step 8
The default Call control signal UD
P port number
value of 5006 is the SIP
VoIP standard.
Change it only if required.
Click “Next
Step 9
To select the default Maintenance Level Password “mainte”
Click “Next”
Case-sensitive password
Step 10
To select the default User Level Password "user"
Click “Next”
Case-sensitive password