Olimpia electronics POWER LIGHT Series User manual

GENERAL
o
These luminaires are used indoors (ta 40 C)
where emergency light is needed. Each
luminaire must be permanently connected to
mains power supply. In normal operation the
power indicator lights and the charge
indicator blinks to show that the batteries are
in charging condition. In case of a mains
power supply failure the power and the
charge indicators turns off and the luminaire
will light the spot lamps automatically in
emergency mode. When the mains power
supply is restored the device turns to normal
operation.
INSTALLATION
To install the luminaire follow the installation
instructions οn page 3.
OPERATION
When the device is powered from the mains,
the charge indicator blinks and confirms the
charging of the batteries. When the batteries
are charged, it lights constantly. If it does not
light, probably, the batteries are
disconnected. If it does not light and the
batteries are connected, then contact the
technician. As long as the charge indicator
blinks, the batteries of the luminaire are
charging and in this period, any autonomy test
must be avoided. When the charging circle is
complete, the indicator lights continuously (it
can be used as an indication of a power
interruption). The batteries charging is done by
a 3 stages technological advanced procedure,
to ensure the appropriate and full charging of
the batteries. The power indicator confirms the
proper connection to the mains. The TEST
button, has a dual use. If pressed instantlly
while the device is connected to the mains, the
device simulates the power interruption, by
lighting the lamps for 3''. In this way, we can
control the driver circuit of the lamps and the
lamps as indicated in paragraph 3 in the text
below.
DIMMING OPTION
When the voltage is interrupted, with
corresponding pressings of the button, we can
choose the illumination of 100%, 50%, 33% or
turned off, either to increase the autonomy time
or not to consume the battery power
unnecessarily. This option is canceled when the
network is restored.
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance or
Page 1 from 3
``POWER LIGHT`` SERIES FOR NON MAINTAINED EMERGENCY LUMINAIRES
923029009_09_012
Thank you for your trust in our products
Olympia Electronics - European manufacturer
ABS/PC, PC
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
EXTERNAL DIMENSIONS
CONSTRUCTION MATERIALS
TYPICAL WEIGHT
GUARANTEE
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Pb)
CHARGING TIME
INDICATIONS - CONTROLS
BATTERY PROTECTION
MINIMUM AUTONOMOUS DURATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
EMERGENCY ILLUMINATION
LIGHT SOURCE
24h
Power indicator, battery charge indicator, TEST button
From overcharge and deep discharge
IP42
5 to 40 C
o
Up to 95%
3 years (1 year for the battery)
180 min90 min
1620lm 790lm
White LEDs
3560gr.2080gr.
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
220-240V AC/50-60Hz
12V/7Ah6V/4Ah
14.4W/16VA5.6W/7.5VA
302 x 94 x 345 mm.
TECHNICAL CHARACTERISTICS (for LED MODULE Specifications see page 2)
GRL-21GRL-29

Page 2 from 3
testing must be done by authorized
personnel only.
2. The device must be connected to the
mains power supply through a fuse
dependent by the total amount of the line’s
power load.
3. It is suggested to check every month the
indication LED for battery charging, and by
pushing instantly the TEST button to check
the emergency circuit and the lamps. If the
luminaire does not light
4. It is suggested to check every 6 months
the minimum autononous duration by
disconnecting the mains power supply.
Count the time that the lamps light and in
case of less time than the minimum
autonomous duration the batteries must be
replaced. If the measured time is
considerably less than the minimum
autonomous duration
The replacement of the battery and the
light source must be done using parts of
the same type, by the manufacturer or by a
competent person.
5.
t i
in battery recycling
points. Do not incinerate.
contact the
installer.
contact the installer.
In case of inactive use for a period greater
than 2 months, disconnect the battery by
pulling out the battery’s connector.
6. I s not allowed to discard batteries in
to common trash bins, they must be
discarded only
Battery replacement.
It can be done only by a competent person
and after the mains interruption.
1. Follow the step 2 of the installation
procedure.
2. Disconnect the cables and remove the old
battery.
3. Connect the new battery with the same type
(step 3 of the installation procedure) and
place it in the position of the old one.
4. Follow the step 5 of the installation
procedure and power the device.
(*) Non Maintained operation: The luminaire lights
its illumination source, only in power supply’s
failure.
Maintained operation: The luminaire lights its
illumination source, when it is powered by the
mains power supply or not.
923029009_09_012
NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
0: Non Maintained (*)
A: Including test device
*90: 1.5 hour duration
180: 3 hours duration
The light source contained in this luminaire shall only be replaced by the manufacturer, or
his agent, or a similar qualified person.
NOTE! The light source is non-user replaceable.
LED CHARACTERISTICS
Olympia Electronics S.A.
50 °C max.
60 °C max.
Cable connection between main pcb and led module
20-25V
5.5W
2605163 2002163
Manufacturer
Model Number
Voltage Range
Connections
Nominal Power
Temperature (tc)
GRL-21 GRL-29
20-25V
2.8W
INDICATION LED STATUS (with the mains power supply connected)
CHARGE POWER
Disconnected battery / not charging
Charged battery Normal operation mode
No mains power supply
Battery under charge
Indicator ON Indicator Blinking
Indicator OFF

Page 3 from 3923029009_09_012
WARRANTY
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of
warranty is specified in the official catalogue of Olympia Electronics and also in the technical leaflet,
which accompanies each product. This warranty ceases to exist if the buyer does not follow the
technical instructions included in official documents given by Olympia Electronics or if the buyer
modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia
Electronics has fully agreed to them in writing. Products that have been damaged can be returned to
the premises of our company for repair or replacement, as long as the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge
the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or
not the buyer the transportation cost.
HEAD OFFICE
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.gr
INSTALLATION PROCEDURE (For wall mounting only)
1. Install the included mounting accessories to hook the device from the mounting holes (Fig. 1).
2. Unfasten the 4 mounting screws to remove the front plastic cover (Fig. 1).
3. Make sure that the battery’s cables are connected to the respective poles. Black cable to (-) pole
and red cable to (+) pole.
4. Install the included cable gland or the rubber o-ring. Pass through the mains cable and stabilize it
by fastening the cable gland. Connect the wires to the terminal blocks L for live wire and Ν for
neutral.The luminaire must be connected to a permanent electrical installation to ensure the
immobilization of the cable.
5. Refit with care the front plastic cover, by fastening the 4 mounting screws (tightening torque
1Nm).
WARNING!! After the installation has finished, charge the batteries for at least 24 hours so as
to obtain the rated autonomous duration.
TEST
button
Cover
retaining
screws
Fig. 1
Charge
indicator
Power
indicator
Mounting holes
N
4
3
L
This manual suits for next models
2
Table of contents
Other Olimpia electronics Lantern manuals
Popular Lantern manuals by other brands

BEGA
BEGA 84 084 Instructions for use

Home Decorators Collection
Home Decorators Collection 23422 instruction manual

IKEA
IKEA 10465008 manual

Cree
Cree IG Series installation instructions

Maretti
Maretti WOLTERINCK COSTA LATERNA 14.1324.04 Mounting instructions

Performance In Lighting
Performance In Lighting LM4 S/EW manual