Olimpia electronics POWER LIGHT Series User manual

GENERAL
o
These luminaires are used indoors (ta 40 C)
where emergency light is needed. Each
luminaire must be permanently connected to
mains power supply. In normal operation the
power and charge indicators are on to
indicate that the batteries are charging. In
case of a mains power supply failure the
power and the charge indicators turns off and
the luminaire will light the spot lamps
automatically in emergency mode. When the
mains power supply is restored the device
turns to normal operation.
INSTALLATION
To install the luminaire follow the installation
instructions οn page 3.
OPERATION
When the device is powered from the mains
and the battery(ies) is (are) connected, the
‘power’ and ‘charge’ indicators are ON. The
‘charge’ indicator indicates the battery
charging operation. If it does not light,
probably, the batteries are disconnected. If it
does not light and the batteries are
connected, then contact the technician. The
power indicator confirms the proper
connection to the mains. The TEST button,
has a dual use. If pressed instantlly while the
device is connected to the mains, the device
simulates the power interruption, by lighting
the lamps for 3''. In that way, we can control
the driver circuit of the lamps and the lamps as
indicated in paragraph 3 in the text below.
DIMMING OPTION
When the luminaire is in emergency mode, with
corresponding pressings of the button, we can
choose the illumination of 100%, 50%, 33% or
turned off, in order to increase the autonomy
duration. This option is canceled when the
network is restored.
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance or
testing must be done by authorized
personnel only.
2. The device must be connected to the
mains power supply through a fuse
dependent by the total amount of the line’s
power load.
3. It is suggested to check every month the
indication LED for battery charging, and by
pushing instantly the TEST button to check
the emergency circuit and the lamps. If the
luminaire does not light, contact the
Page 1 from 3
``POWER LIGHT`` SERIES FOR NON MAINTAINED EMERGENCY LUMINAIRES
923021042_09_004
Thank you for your trust in our products
Olympia Electronics - European manufacturer
Aluminum, ABS/PC, PC
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
EXTERNAL DIMENSIONS
CONSTRUCTION MATERIALS
TYPICAL WEIGHT
GUARANTEE
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (Pb)
CHARGING TIME
INDICATIONS - CONTROLS
BATTERY PROTECTION
MINIMUM AUTONOMOUS DURATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
EMERGENCY ILLUMINATION
LIGHT SOURCE
24h
Power indicator, battery charge indicator, TEST button
From overcharge and deep discharge
IP42
5 to 40 C
o
Up to 95%
3 years (1 year for the battery)
180 min90 min
3200lm
White power LEDs
6300gr.4100gr.
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
220-240V AC/50-60Hz
2x12V/7Ah12V/7Ah
13.3W/14VA
302 x 94 x 350 mm.
TECHNICAL CHARACTERISTICS (for LED MODULE Specifications see page 2)
GRL-21/H/90 GRL-21/H/180

Page 2 from 3
installer.
contact the installer.
In case of inactive use for a period greater
than 2 months, disconnect the battery by
pulling out the battery’s connector.
6. I s not allowed to discard batteries in
to common trash bins, they must be
discarded only
4. It is suggested to check every 6 months
the minimum autonomy duration by
disconnecting the mains power supply.
Count the time that the lamps light and in
case of less time than the minimum
autonomy duration the batteries must be
replaced. If the measured time is
considerably less than the minimum
autonomy duration
The replacement of the battery and the
light source must be done using parts of
the same type, by the manufacturer or by a
competent person.
5.
t i
in battery recycling
points. Do not incinerate.
Battery replacement
It can be done only by a competent person
and after the mains interruption.
1. Follow the step 2 of the installation
procedure.
2. Disconnect the cables and remove the old
battery.
3. Connect the new battery with the same type
(step 3 of the installation procedure) and
place it in the position of the old one.
4. Follow the step 5 of the installation
procedure and power on the device.
(*) Non Maintained operation: The luminaire lights
its illumination source, only in power supply’s
failure.
Maintained operation: The luminaire lights its
illumination source, when it is powered by the
mains power supply or not.
923021042_09_004
NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
0: Non Maintained (*)
A: Including test device
90: 1.5 hour duration
180: 3 hours duration
The light source contained in this luminaire shall only be replaced by the manufacturer, or
his agent, or a similar qualified person.
NOTE! The light source is non-user replaceable.
LED CHARACTERISTICS
Olympia Electronics S.A.
Cable connection between main pcb and led module
Manufacturer
Model Number
Voltage Range
Connections
Nominal Power
Temperature (tc)
GRL-21/H/90 GRL-21/H/180
INDICATION LED STATUS (with the mains power supply connected)
CHARGE POWER
Disconnected battery / not charging
Charged battery Normal operation mode
No mains power supply
Indicator ONIndicator OFF
68 °C max. across the board
17.5-20.5V
14W
1005183

Page 3 from 3923021042_09_004
WARRANTY
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of
warranty is specified in the official catalogue of Olympia Electronics and also in the technical leaflet,
which accompanies each product. This warranty ceases to exist if the buyer does not follow the
technical instructions included in official documents given by Olympia Electronics or if the buyer
modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia
Electronics has fully agreed to them in writing. Products that have been damaged can be returned to
the premises of our company for repair or replacement, as long as the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge
the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or
not the buyer the transportation cost.
HEAD OFFICE
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.gr
INSTALLATION PROCEDURE (For wall mounting only)
1. Install the included mounting accessories to hook the device from the mounting holes (Fig. 1).
2. Unfasten the 4 mounting screws to remove the front plastic cover (Fig. 1).
3. Make sure that the battery’s cables are connected to the respective poles. Black cable to (-) pole
and red cable to (+) pole.
4. Install the included cable gland or the rubber o-ring. Pass through the mains cable and stabilize it
by fastening the cable gland. Connect the wires to the terminal blocks L for live wire and Ν for
neutral.The luminaire must be connected to a permanent electrical installation to ensure the
immobilization of the cable.
5. Refit with care the front plastic cover, by fastening the 4 mounting screws (tightening torque
1N*m).
WARNING!! After the installation has finished, charge the batteries for at least 24 hours so as
to obtain the rated autonomy duration.
TEST
button
Fig. 1
Power
indicator
Mounting holes
Charge
indicator
Cover
retaining
screws
4
N
L
3
This manual suits for next models
2
Table of contents
Other Olimpia electronics Lantern manuals