MAX OPERATING PRESSURE:..............................................................5 bar (500kPa)
RECOMMENDED OPERATION PRESSURE:..........................................1.5-5 bar (150-500kPa)
MAX HOT WATER TEMPERATURE:.....................................................65°C
RECOMMENDED HOT WATER TEMPERATURE:..................................50°C Paris Wall Spout
PA102200CR/PA102206MB/PA102200BN
Where water pressure exceeds 500kPa, a pressure reducing device is required to be installed. Note that
water pressure overnight can reach 150% of the daytime pressure.
CARE & MAINTENANCE
THIS BASIN/BATH SPOUT MUST BE INSTALLED BY A LICENSED PLUMBER IN
ACCORDANCE WITH LOCAL REGULATIONS
This Oliveri tap is manufactured to standard AS/NZS 3718.
Note: - Copper tube pieces, sand, dirt or stones
- Thread tape
- Other objects not normally present in potable water supplies.
Technical Data
Installation Instructions
PA102200CR/PA102206MB/PA102200BN installation instructions.pdf
Clean with a soft cloth and warm soapy water as necessary - rinse and dry after cleaning. Under No
Circumstances should abrasive or acid based cleaning products be used.
WARRANTY
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are
entitled to a replacement or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to
be of acceptable quality and the failure does not amount to a major failure.
SERVICE
If a warranty service agent finds that the spout is not at fault, T2 Services Pty Ltd reserves the right to
pass on any callout fee to the householder.
Issue Date 30/11/2018 Revision Number: V1.0
This basin/bath spout is warranted to be free from manufacturing defects for a period of 10 Years:10 years for body,
5 years for seals, tails, fittings and aerators, 1 year for finish and labour, when used in a domestic situation.
This warranty does not cover against normal wear and will be voided if the product is misused or
not installed in accordance with these instructions. Note: Fitting spout-attached devices, including water
filters, to this spout will void warranty.
If the Plumber / Installer is satisfied that the problem is not due to poor installation, contact T2 Services Pty Ltd
for assistance on:
Note: Installation of aerators containing flow regulators.
Upon re-installation, the aerator should be tightened with an aerator key to prevent removal by hand.
Before attempting any work involving mains water supply lines, ensure the water supply is shut off.
This basin/bath spout must be installed in accordance with these instructions.
If the problem represents a danger, or damage to property may occur, immediately shut off the water
supply. If the spout requires servicing, please contact your plumber (preferably the one who installed
it). Most problems occur due to contaminated supply lines or water pressure exceeding 500KPa.
Unscrew and clean the spout aerator periodically - especially if you notice a drop in water pressure.
Note: Warranty claims will not be honoured where the spout has malfunctioned due to
the presence in the water supply of ;
In the event this product is rendered obsolete and a replacement product is required, Oliveri Solutions Pty Ltd
reserves the right to supply a product of equal substitution at their discretion.
Ph: (07) 55960738
Fax: (07) 55273353
Email: [email protected]
https: //oliveri.com.au/service-and-warranty
PA102200CR/PA102206MB/PA102200BN installation instructions.pdf
Installation Instructions
AB
DE
C
Max 18mm 1/2BSP thread
Issue Date 30/11/2018 Revision Number: V1.0
Installation Instructions
1. Remove product from packaging and check for damages, if the product is damaged do not install and
return to store of purchase.
2. Ensure Product is complete as per exploded drawing.
3. Apply sufficient thread seal tape to the ½”bsp thread. (do not overload thread with thread seal tape as
this will put undue pressure on bath spout (D).
4. Slide wall plate (B) onto ½” BSP thread ensuring sealing rubber (A) is in place on the back of the wall
plate (B).
5. Screw Wall Basin/Bath Spout (C) onto ½”bsp thread.
General Note: This product is to be installed by a licensed plumber, installation must comply with AS/NZS
3500 and local plumbing codes.
°
C
Pressures & Temperatures
Maximum Hydrostatic Pressure – 500 kpa. (As per AS/NZS3500)
Note: AS/NZS 3500.1-2003 (Clause 3.3.4) states that “Provision shall be made to ensure that the
maximum static pressure at any outlet, other than a fire service outlet, within a building does not
exceed 500 kPa.
Note: Pressures above 500kPa can cause damage from water hammer, reduced life of appliances,
taps and fittings, and cause excessive noise in the system.
Minimum Hydrostatic Pressure – 100 kpa
The Maximum operating temperature for the Mixer Tap is 65 .
Please ensure that the lines are flushed prior to installation as contaminates in the water can damage the
Aerator and also affect the performance of the product.
To the consumer
Under No Circumstances should any abrasive, cream or acid based cleaning agents be used as these
types of cleaners will damage the finish, seals and aerators.
1. The bath spout is to only be cleaned with warm soapy water.
2.
N.B The Wall Basin/Bath spout is pre-fitted with a flow regulated aerator. If the spout is being
used over a bath, the aerator is to be removed by Aerator key (E) and then fitted with open flow
regulator (D).

This manual suits for next models

3

Other Oliveri Bathroom Fixture manuals

Oliveri Dublin DU7130F-N User manual

Oliveri

Oliveri Dublin DU7130F-N User manual

Oliveri Dublin DU7130D-N User manual

Oliveri

Oliveri Dublin DU7130D-N User manual

Oliveri Rome Dual Shower User manual

Oliveri

Oliveri Rome Dual Shower User manual

Oliveri Dublin DU7130E-N User manual

Oliveri

Oliveri Dublin DU7130E-N User manual

Popular Bathroom Fixture manuals by other brands

Gustavsberg GB1921102052 Installation instruction

Gustavsberg

Gustavsberg GB1921102052 Installation instruction

OVE TAMPA-PRO TP0200401 installation manual

OVE

OVE TAMPA-PRO TP0200401 installation manual

Ideal-Standard U8425AA Installation

Ideal-Standard

Ideal-Standard U8425AA Installation

newform MINI-X PRO 67606E instructions

newform

newform MINI-X PRO 67606E instructions

Korpinen 21273103-00 installation guide

Korpinen

Korpinen 21273103-00 installation guide

KWC Fit A100 Installation and service manual

KWC

KWC Fit A100 Installation and service manual

Unique Automation Bathomatic Basic installation guide

Unique Automation

Unique Automation Bathomatic Basic installation guide

Franke ZSHOW0008 Installation and operating instructions

Franke

Franke ZSHOW0008 Installation and operating instructions

albatros Ilyt Instructions for operation

albatros

albatros Ilyt Instructions for operation

METHVEN MINIMALIST MK2 installation guide

METHVEN

METHVEN MINIMALIST MK2 installation guide

Clou Wash Me CL/02.13034 installation instructions

Clou

Clou Wash Me CL/02.13034 installation instructions

Timago JMC-C 5105 Instructions for use

Timago

Timago JMC-C 5105 Instructions for use

Victorian Plumbing Arezzo installation instructions

Victorian Plumbing

Victorian Plumbing Arezzo installation instructions

NYMAS G1235C Installation and operating instructions

NYMAS

NYMAS G1235C Installation and operating instructions

agape PEAR C ACER0896F Assembly instructions

agape

agape PEAR C ACER0896F Assembly instructions

Gessi 38780 manual

Gessi

Gessi 38780 manual

MARIMEX UNO 14 instructions

MARIMEX

MARIMEX UNO 14 instructions

T&S B-0126 Installation and maintenance instructions

T&S

T&S B-0126 Installation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.