Page - 8
Violet Wire - (Starter Output): When remote starting, this output
supplies 12 Volts Positive to the vehicle's starter circuit. The Violet wire is best
connected when installing the starter interrupt circuit. Its connection point must
be on the starter side of the interrupt relay, not the Ignition Switch side. This is
easily accomplished when installing the starter interrupt by combining the Violet
Starter Output wire with the starter interrupt's White wire and then connecting
both of these wires to the starter side of the cut vehicle wire. This is explained in
further detail on the next page.
CONNECTION: The Violet wire connects to the vehicle's Starter wire, after
the starter interrupt. See pages 9 & 10 for specific instructions. The vehicle
starter wire will show Positive 12 Volts when the ignition key is in the "Start"
position only. This wire is found in the ignition switch wiring harness, and it is
important to make this connection on the ignition switch side of, and not on the
starter side of, the neutral safety switch.
Some vehicles have a second Starter wire known as a "Cold Start" wire. When
this second wire is present, there are several options. If the two Starter wires are
the same circuit, both of them may be connected to theAL-1610-EDPViolet wire.
If the two Starter wires are separate circuits, an additional relay may be config-
ured, from the Satellite Relay Port; or the Pink/White ignition output may be re-
programmed as a start wire and used.
supplypowertothechosenvehiclecircuitforthedurationoftheremotestartengine
run period.
CONNECTION: Connect this wire to the vehicle's Accessory wire. This
circuit in the vehicle can vary in its function. Typically, its primary function is to
supply power to the Heat, Ventilation and Air Conditioning (HVAC) system. The
connection point for this wire is also found in the ignition switch wiring harness.
In some cases the correct vehicle wire will show Positive 12 Volts in the "Run"
and "Accessory" ignition key positions but in other vehicles it will show the volt-
age only in the "Run" ignition key position. This output should not be used if the
vehicle's wire also shows voltage when the ignition key is in the "Start" position.
Pink/White Wire - Programmable Relay Output (default:
Ignition;options:Starteror Accessory): ThislargePink/Whitewireis
the fourth of 4 onboard relays which are dedicated remote starting outputs.
However,thisoutputisdifferent,inthatitisprogrammable,byInstallerFeature#8.
Thisoutputisfactorydefault-setforIgnitionoperation,or,itmaybereprogrammed
to operate as an Accessory output or as a Start output.
CONNECTION: Asneeded. Ifusedas its default Ignition setting, connection
is similar to that of the Pink ignition output wire. If it is changed, if set as an
AccessoryoutputconnectionissimilartotheOrangewire;andifsetasaStartoutput
connection is similar to the that of the Violet wire.
The Installer Programmable Features
Thesecondgroupoffeatures,theInstallerProgrammableFeatures,areaccessedas
the second level of features’ programming, which is pressing the Valet Switch 10
times instead of 5 times when entering Programming Mode (page 42). Caution:
Thesefeatureshaveacriticalaffectuponthesystem’soperations,andinmany
cases, also upon the system’s wiring connections. These features should
NEVER be changed, except by the installer or other qualified professional.
This booklet should be consulted for the proper wiring connections, as associated
with these programmable features.
The Excalibur AL-1610-EDP’s 10 Installer Programmable Features:
1 Doorlocking Functions
2 Light Output Functions
3 Horn Output Functions
4 Turbo Timer
5 ManualTransmission Remote Starting
6 “TachWire” or“Tachless” StarterOperations
7 Extended Starter CrankingTime
8 Programmable Remote Start Relay
9 Arm, Disarm or Additional Channels
10 Gasoline or Diesel Engine
Use the step-by-step instructions on page 42 to change any of the Installer
Programmable Features, along with the feature’s option choices and related
programmingtransmitterbuttonassignmentfoundinthefollowingindividualfeature
descriptions.
Page - 37
Installer Programmable Features should only be used by the original
or other qualified installer, AND individual Installer Features should
only be used, where applicable, with the correct wiring connections.
Feature #1 Doorlocking Functions
Factory Default Setting .8 Second Lock & Unlock Output
(press “arm/lock” button to program)
Options:
3 Second Lock & Unlock Output (press “disarm/unlock” button to program)
Double Pulse Unlock Output (press “II” button to program)
Total Closure Lock Output (press “III” button to program)
Thissinglefeaturegivestheinstallerseveralneededoptions,tomatchtheAL-1610-
EDP’s doorlocking outputs to suite different vehicle requirements.