Omnitron Systems OmniConverter GPoE/SE User manual

OmniConverter®
GPoE/SE and GPoE+/SE
User Manual
38 Tesla, Irvine, CA 92618 USA
Phone: (949) 250-6510; Fax: (949) 250-6514
General and Copyright Notice
This publication is protected by U.S. and international copyright laws. All rights
reserved. The whole or any part of this publication may not be reproduced, stored
in a retrieval system, translated, transcribed, or transmitted, in any form, or by
any means, manual, electric, electronic, electromagnetic, mechanical, chemical,
optical or otherwise, without prior explicit written permission of Omnitron Systems
Technology, Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.:
FlexPointTM, FlexSwitchTM, iConverter®, miConverterTM, NetOutlook®, OmniLight®,
OmniConverter®, RuggedNet®, Omnitron Systems Technology, Inc.TM, OSTTM and
the Omnitron logo.
All other company or product names may be trademarks of their respective owners.
The information contained in this publication is subject to change without notice.
Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors.
Warranty
This product is warranted to the original purchaser (Buyer) against defects in
material and workmanship for a period of two (2) years from the date of shipment.
A lifetime warranty may be obtained by the original purchaser by registering this
product at www.omnitron-systems.com/support within ninety (90) days from the
date of shipment. During the warranty period, Omnitron will, at its option, repair or
replace a product which is proven to be defective with the same product or with a
product with at least the same functionality.
For warranty service, the product must be sent to an Omnitron designated facility,
at Buyer’s expense. Omnitron will pay the shipping charge to return the product to
Buyer’s designated US address using Omnitron’s standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to product malfunctions resulting from
improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-
supplied equipment, Buyer-supplied interfacing, unauthorized modications or
tampering with equipment (including removal of equipment cover by personnel not
specically authorized and certied by Omnitron), or misuse, or operating outside
the environmental specication of the product (including but not limited to voltage,
ambient temperature, radiation, unusual dust, etc.), or improper site preparation
or maintenance.
No other warranty is expressed or implied. Omnitron specically disclaims the implied
warranties of merchantability and tness for any particular purpose.
The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron
shall not be liable for any direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal theory.
Page 2

OmniConverter® GPoE/SE and GPoE+/SE
User Manual
Product Overview
The OmniConverter GPoE/SE and GPoE+/SE are cost-effective, multi-port media
converters that convert 10/100/1000BASE-T copper to 1000BASE-X ber and
support Power-over-Ethernet (PoE and PoE+). Classied as Power Sourcing
Equipment (PSE), the GPoE/SE and GPoE+/SE provides power to a Powered
Device (PD) using standard UTP cables that carry the Ethernet data.
The main function of the PSE is to automatically detect a PD, classify the PD and
supply power to the link (only if a PD is detected). The PSE detects a PD by applying
a low voltage on the cable and then looks for a signature resistance from the attached
PD. A compliant PD is required to have this signature resistance. Classication of
the PD is done to determine the maximum power levels required by the PD. The
PSE will determine the proper classication and power requirements of the PD.
After the PD is classied, the PD is powered up according to its power requirements.
OmniConverter GPoE/SE and GPoE+/SE automatically preform the detection,
classication and powering functions. The GPoE/SE supports IEEE 802.3af PoE
standard providing up to 15.4W of DC power to the PD. The GPoE+/SE supports
IEEE 802.3at PoE+ standard providing up to 30W of DC power to the PD.
The fiber and copper ports support auto-negotiation and will independently
negotiate with the attached device. The copper ports support auto-crossover
10/100/1000BASE-T interface and Alternative B powering mode.
RJ-45 Pin Out Alternative B
4,5 Vport Positive
7,8 Vport Negative
The ports support a maximum frame size of up to 10,240 bytes.
INSTALLATION PROCEDURE
Installation of the equipment should be such that the air ow in the front, back, side
and top vents of the module is not compromised or restricted.
1) Install the Module
2) Apply Power
3) Connect Cables
4) Verify Operation
Page 4
Environmental Notices
The equipment covered by this manual must be disposed of or recycled in
accordance with the Waste Electrical and Electronic Equipment Directive (WEEE
Directive) of the European Community directive 2012/19/EU on waste electrical and
electronic equipment (WEEE) which, together with the RoHS Directive 2015/863/
EU, for electrical and electronic equipment sold in the EU after July 2019. Such
disposal must follow national legislation for IT and Telecommunication equipment
in accordance with the WEEE directive: (a) Do not dispose waste equipment with
unsorted municipal and household waste. (b) Collect equipment waste separately.
(c) Return equipment using collection method agreed with Omnitron.
The equipment is marked with the WEEE symbol shown to indicate that it
must be collected separately from other types of waste. In case of small items the
symbol may be printed only on the packaging or in the user manual. If you have
questions regarding the correct disposal of equipment go to www.omniton-systems.
Safety Warnings and Cautions
ATTENTION: Observe precautions for handling electrostatic discharge
sensitive devices.
WARNING: Potential damage to equipment and personal injury.
WARNING: Risk of electrical shock.
Customer Support Information
If you encounter problems while installing this product, contact Omnitron Technical
Support:
Phone: (949) 250-6510
Fax: (949) 250-6514
Address: Omnitron Systems Technology, Inc.
38 Tesla
Irvine, CA 92618, USA
Email: [email protected]
URL: www.omnitron-systems.com
040-09460-001D 11/21
Page 3

1) Installing the Module
Wall Mounting
The wall mounting height of the module should be less than or equal to 2 meters
(6.6 feet) from the oor. Use the four mounting holes on the module to secure the
module to the wall. The module can accommodate #6 screws (not included).
Installation of the module should be such that the air ow in the front, back, side
and top vents of the switch are not compromised or restricted.
The accessory cables should have their own strain relief and do not pull down on
the module.
Rack Mounting
The module can be rack mounted using the optional Rack Mount Shelf (8260-0).
Refer to the Rack Mount Shelf user manual (040-08260-001x) for the proper
installation guidelines.
Follow the same guidelines above when rack mounting the module.
DIN-rail Mounting
The module can be DIN-rail mounted using the optional DIN-rail Mounting Bracket
(8250-0) or the optional DIN-rail Mounting Clip (8251-0). Refer to the user manuals
(040-08250-001x or 040-08251-001x) for the proper installation guidelines.
2) Apply Power
AC Power
Secure the ground wire to the grounding screw located on the back of the module.
To power the unit using the AC/DC adapter, route the power cord through the
provided strain relief for additional support. Then connect the barrel connector
at the end of the wire on the AC/DC adapter to the 2.1mm DC barrel connector
(center-positive) on the unit. Connect the AC/DC adapter to the AC outlet. Conrm
that the module has powered up properly by checking the Power LED located on
the front of the installed module.
Installation of the equipment should be such that the air ow in the front, back, side
and top vents of the chassis are not compromised or restricted.
NEVER ATTEMPT TO OPEN THE CHASSIS OR
SERVICE THE POWER SUPPLY. OPENING THE
CHASSIS MAY CAUSE SERIOUS INJURYOR DEATH.
THERE ARE NO USER REPLACEABLE OR
SERVICEABLE PARTS IN THIS UNIT.
WARNING!!!
Page 5
DC Power
This module is intended for installation in restricted access areas. (“Les matériels
sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”).
A restricted access area can be accessed only through the use of a special key, or
other means of security.
The over current protection for connection with centralized DC shall be provided in
the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and
installed per the National Electrical Code, ANSI/NFPA-70.
Appropriate overloading protection should be provided on the DC power source
outlets utilized.
The GPoE/SE requires 48 to 57VDC @ 0.63 Amp max rated power and the GPoE+/
SE requires 48 to 57VDC @ 1.15 Amp max rated power. See specication table
for specic model requirements.
Description IEEE 802.3af PoE IEEE 802.3at PoE+
Power Supply Voltage Range 46.0 to 57.0 VDC 51.0 to 57.0 VDC
Voltage Range at PSE port Output 44.0 to 56.0 VDC 50.0 to 56.0 VDC
Maximum Power from PoE/PSE port 15.4 watts 30 watts
Minimum Voltage at PoE/PD port input* 37.0 VDC 42.5 VDC
Minimum Power at PoE/PD port* 12.95 watts 25.5 watts
* at 100 meters using Cat5
WARNING: OnlyaDC power source that complies with
safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.
WARNING REGARDING EARTHING GROUND:
o
o
o
o
This equipment shall be connected to the DC supply
system earthing electrode conductor or to a bonding
jumper from an earthing terminal bar or bus to which the
DC supply system earthing electrode is connected.
This equipment shall be located in the same immediate
area (such as adjacent cabinets) as any other equipment
that has a connection between the earthed conductor of
the same DC supply circuit and the earthing conductor,
and also the point of earthing of the DC system. The DC
system shall not be earthed elsewhere.
The DC supply source is to be located within the same
premises as this equipment.
There shall be no switching or disconnecting devices in
the earthed circuit conductor between the DC source and
the earthing electrode conductor.
Page 6

Locate the DC circuit breaker of the external power source, and switch the circuit
breaker to the OFF position.
Prepare a power cable using a three conductor insulated wire (not supplied) with
12AWG to 14AWG thickness. Cut the power cable to the length required.
Strip approximately 3/8 of an inch of insulation from the power cable wires.
Connect the ground wire to the grounding screws on the back of the module.
Route the power cables through the provided strain relief for additional support.
Connect the power cables to the module by fastening the stripped ends to the DC
power connector.
WARNING: Note the wire colors used in making the positive, negative and ground
connections. Use the same color assignment for the connection at the circuit breaker.
Connect the power wires to the circuit breaker and switch the circuit breaker ON.
If any module are installed, the Power LED will indicate the presence of power.
During the installation, ensure that the ground potentials are maintained throughout
the system connections. This includes but not limited to the power source ground
and any shielded cabling grounds.
Installation of the equipment should be such that the air ow in the front, back, side
and top vents of the chassis are not compromised or restricted.
NEVER ATTEMPT TO OPEN THE CHASSIS OR
SERVICE THE POWER SUPPLY. OPENING THE
CHASSIS MAY CAUSE SERIOUS INJURYOR DEATH.
THERE ARE NO USER REPLACEABLE OR
SERVICEABLE PARTS IN THIS UNIT.
WARNING!!!
3) Connect Cables
a. When using the SFP model, insert the SFP Fiber transceiver into the SFP
receptacle on the front of the module (see the SFP Data Sheet 091-17000-001
for supported Fast Ethernet transceivers).
NOTE: The release latch of the SFP Fiber transceiver must be in the closed
(up) position before insertion.
b. Connect an appropriate multimode or single-mode ber cable to the ber port
on the front of the module. It is important to ensure that the transmit (TX) is
attached to the receive side of the module at the other end and the receive
(RX) is attached to the transmit side. When using single-ber (SF) models, the
TX wavelength must match the RX wavelength at the other end and the RX
wavelength must match the TX wavelength at the other end.
c. Connect the Ethernet 10/100/1000 RJ-45 port via a Category 5 or better cable
to an external 10BASE-T, 100BASE-TX or 1000BASE-T Ethernet device.
Page 7
4) Verify Operation
Once the module has been installed and congured per steps 1 - 3, verify the module
is operational by viewing the LED indicators.
The Power LED indicates the module is receiving power.
The Fiber Optic 100 LED indicates the ber optic connection has been established.
The RJ-45 10/100/1000 LEDs indicate the speed of the RJ-45 connection. P3 is
only available on three port modules.
The PSE LED indicates the module has established a successful detection of a PD
and is supplying Power over Ethernet.
LED Indicators
Legend Indicator Description
Pwr OFF Unit not powered
Green - ON Unit powered
P1
100
OFF No link
Green - ON Port linked at 100Mbps
Green - Blinking Port data activity at 100Mbps
P2 and P3
10
OFF No link
Green - ON Port linked at 10Mbps
Green - Blinking Port data activity at 10Mbps
P2 and P3
1000
OFF No link
Green - ON Port linked at 1000Mbps
Green - Blinking Port data activity at 1000Mbps
P2 and P3
100
(10 + 1000)
OFF No link
Green - ON Port linked at 100Mbps
Green - Blinking Port data activity at 100Mbps
P2 and P3
PSE
OFF Port PSE is inactive
Green - Blinking 1 ash every 1 second - Signature resistance too low
Green - Blinking 2 ashes every 1 second - Signature resistance too high
Green - Blinking 5 ashes every 1 second - Port overload condition
Green - ON Port PSE is active
Page 8

SPECIFICATIONS
Description
OmniConverter GPoE/SE
10/100/1000BASE-T to 1000BASE-X
Fiber Media Converter with PoE
Standard Compliances IEEE 802.3,
IEEE 802.3af (15.40 watts max),
PoE Supported Modes IEEE Alternate B (Alt B)
Regulatory Compliances
(*Pending)
Safety: UL 62368-1*,
UL 60950-1,
IEC 62368-1*,
IEC 60950-1,
EN 62368-1*,
EN 60950-1,
CAN/CSA C22.2 No. 62368-1-14*,
CAN/CSA C22.2 No. 60950-1,
CE Mark
EMI: FCC Class A,
CE Class A
EMS: CE
IP Rating: IP20 Protection
Environmental RoHS, WEEE, REACH
Frame Size Up to 10,240 bytes
Port Types
Copper: 10/100BASE-T (RJ-45)
Fiber: 100BASE-X (ST, SC, SFP)
100BASE-BX (SC, SFP)
Cable Types
Copper: EIA/TIA 568A/B, Cat 5 UTP and higher
Fiber: Multimode: 50/125, 62.5/125µm
Single-mode: 9/125µm
AC Power Requirements
(Models with AC/DC Adapters)
1 RJ-45 Port
100 - 240VAC/47 to 63Hz
0.21A @ 120VAC (typical)
2 RJ-45 Ports
100 - 240VAC/50 - 60Hz
0.39A @ 120VAC (typical)
DC Power Requirements
(Models with DC Terminals)
1 RJ-45 Port
+/-46 to +/-57VDC;
0.34A @ 48VDC
2 Pin Terminal (non-isolated)
2 RJ-45 Ports
+/-46 to +/-57VDC;
0.63A @ 48VDC
2 Pin Terminal (non-isolated)
1 RJ-45 Port
+/-46 to +/-57VDC;
0.34A @ 48VDC
3 Pin Terminal (isolated)
2 RJ-45 Ports
+/-46 to +/-57VDC;
0.63A @ 48VDC
3 Pin Terminal (isolated)
Dimensions (W x D x H) 3.8” x 4.8” x 1.0” (96.5 mm x 121.9 mm x 25.4 mm)
Weight Module Only: 1.1 lbs. (498.9 grams)
Module w/ Adapter: 2.3 lbs. (1043.3 grams)
Operating Temperature
Commercial: 0 to 50°C
Wide: -40 to 60°C (-20°C AC cold start)
Storage: -40 to 80°C
Humidity 5 to 95% (non-condensing)
Altitude -100m to 4,000m
MTBF (hours) Module Only: 910,000
AC/DC Adapter: 100,000
Warranty Lifetime warranty with 24/7/365 free Technical Support
Page 9
Description
OmniConverter GPoE+/SE
10/100/1000BASE-T to 1000BASE-X
Fiber Media Converter with PoE+
Standard Compliances IEEE 802.3,
IEEE 802.3af (15.40 watts max) and IEEE 802.3at (30 watts max)
PoE Supported Modes IEEE Alternate B (Alt B)
Regulatory Compliances
(*Pending)
Safety: UL 62368-1*,
UL 60950-1,
IEC 62368-1*,
IEC 60950-1,
EN 62368-1*,
EN 60950-1,
CAN/CSA C22.2 No. 62368-1-14*,
CAN/CSA C22.2 No. 60950-1,
CE Mark
EMI: FCC Class A,
CE Class A
EMS: CE
IP Rating: IP20 Protection
Environmental RoHS, WEEE, REACH
Frame Size Up to 10,240 bytes
Port Types
Copper: 10/100BASE-T (RJ-45)
Fiber: 100BASE-X (ST, SC, SFP)
100BASE-BX (SC, SFP)
Cable Types
Copper: EIA/TIA 568A/B, Cat 5 UTP and higher
Fiber: Multimode: 50/125, 62.5/125µm
Single-mode: 9/125µm
AC Power Requirements
(Models with AC/DC Adapters)
1 RJ-45 Port
100 - 240VAC/47 to 63Hz
0.37A @ 120VAC (typical)
2 RJ-45 Ports
100 - 240VAC/50 - 60Hz
0.70A @ 120VAC (typical)
DC Power Requirements
(Models with DC Terminals)
1 RJ-45 Port
+/-48 to +/-57VDC;
0.60A @ 48VDC
2 Pin Terminal (non-isolated)
2 RJ-45 Ports
+/-48 to +/-57VDC;
1.15A @ 48VDC
2 Pin Terminal (non-isolated)
1 RJ-45 Port
+/-48 to +/-57VDC;
0.60A @ 48VDC
3 Pin Terminal (isolated)
2 RJ-45 Ports
+/-48 to +/-57VDC;
1.15A @ 48VDC
3 Pin Terminal (isolated)
A minimum DC input voltage of 50VDC is required to guarantee 25.5 watts
(for 802.3at) at the end of 100 meters on Cat 5 cable or better.
Dimensions (W x D x H) 3.8” x 4.8” x 1.0” (96.5 mm x 121.9 mm x 25.4 mm)
Weight Module Only: 1.1 lbs. (498.9 grams)
Module w/ Adapter: 2.3 lbs. (1043.3 grams)
Operating Temperature
Commercial: 0 to 50°C
Wide: -40 to 60°C (-20°C AC cold start)
Storage: -40 to 80°C
Humidity 5 to 95% (non-condensing)
Altitude -100m to 4,000m
MTBF (hours) Module Only: 780,000
AC/DC Adapter: 100,000
Warranty Lifetime warranty with 24/7/365 free Technical Support
Page 10
Table of contents
Other Omnitron Systems Media Converter manuals

Omnitron Systems
Omnitron Systems iConverter 8878-27 User manual

Omnitron Systems
Omnitron Systems OmniConverter 10G User manual

Omnitron Systems
Omnitron Systems OmniConverter FPoE/S User manual

Omnitron Systems
Omnitron Systems OmniConverter FPoE/SL User manual

Omnitron Systems
Omnitron Systems iConverter XG User manual

Omnitron Systems
Omnitron Systems OmniConverter FPoE/SE User manual

Omnitron Systems
Omnitron Systems iConverter T1 User manual

Omnitron Systems
Omnitron Systems iConverter XG+ User manual