Section 2 Wiring and Mounting
10
2-3-2 Terminal block assignment
TERMINAL OUTER CONNECTION
1 - 2 Connect to the 24 VDC power supply, note the polarity indicated on the label.
3 - 4 RESET button; connect a normally opened contact (N.O.).
4 - 5 TEST button; connect a normally closed (N.C.).
6 - 7 Connect the muting lamp. If the lamp has the polarity, make sure that connect the positive
terminal to the terminal 6, and connect the negative terminal to the terminal 7.
8 Input of the muting B sensor (For controlling light curtain 1). Connect to the N.O. contact or PNP
transistor output of the muting sensor (photoelectric switch, proximity switch, other).
9 Input of the muting A sensor (For controlling light curtain 1). Connect to the N.O. contact of the
muting sensor (photoelectric switch, proximity switch, other).
10 Input of the muting D sensor (For controlling light curtain 2). Connect to the N.O. contact of the
muting sensor (photoelectric switch, proximity switch, others)
11 Input of the muting C sensor (For controlling light curtain 2). Connect to the N.O. contact of the
muting sensor (photoelectric switch, proximity switch, others)
12 Terminal not used.
13 - 14 (OUT1) safety output 1 with N.O. contact.
15 - 16 (OUT2) safety output 2 with N.O. contact.
17 - 18 Power supply transmitters (TX1) for light curtain 1.
24VDC wire to terminal 17, 0V wire to terminal 18.
19 - 20 Terminal not used.
21 - 22 Power supply transmitters (TX2) for light curtain 2.
24VDC wire to terminal 21, 0V wire to terminal 22.
23 - 24 Terminal not used.
25 - 26 Power supply receivers (RX1) for light curtain 1.
24VDC wire to terminal 25, 0V wire to terminal 26.
27 - 28 Connect to the PNP output of the receivers (RX1) of light curtain.
Control output 1 wire and Control output 2 wire to terminal 27 and 28.
(Two control outputs must be used.)
29 - 30 Power supply receivers (RX2) for light curtain 2.
24VDC wire to terminal 29, 0V wire to terminal 30
31 - 32 Connect to the PNP output of the receivers (RX2) of light curtain 2
Control output 1 wire and Control output 2 wire to terminal 31 and 32.
(Two control outputs must be used.)
[Note]: If only one set of light curtain is used, connect 24VDC line to unused light
curtain input terminals. Otherwise, the F3SP locked.