Specifications by Model
Configuration Devices (CPU and Expansion Units)
No. of I/O points
Program capacity
DM Area
EM Area
LD instruction time
Control
I/O control
Programming language
Instruction length
No. of instructions
No. of tasks
Interrupt types
Internal communi-
cations port
Mountable optional
products
Main functions
Specifications
250 Ksteps 60 Ksteps 30 Ksteps 20 Ksteps 60 Ksteps 30 Ksteps 20 Ksteps 10 Ksteps120 Ksteps
20 ns
Stored program method
Both cyclic scan method and on-demand mode can be used.
Ladder diagram
1 to 7 steps/instruction
Approx. 400
288 (256 shared with interrupt tasks)
Scheduled interrupts, I/O interrupts, power OFF interrupt, and external I/O interrupts (interrupts from Inner Boards and CPU Bus Units).
1 peripheral port and 1 RS-232C port
Memory Cards, Inner Boards (e.g., Serial Communications Boards)
40 ns
960 (No. of Expansion Racks: 2)
1,280
(No. of Expansion
Racks: 3)
5,120 (No. of Expansion Racks: 7)
32 kW x 13 banks 32 kW x 7 banks 32 kW x 3 banks 32 kW x 1 bank 32 kW x 1 bank 32 kW x 1 bank 32 kW x 1 bank 32 kW x 1 bank32 kW x 3 banks
Name
CPU Units
CPU Backplanes
CPU Backplanes
(for CS1 Units only)
Expansion Backplanes
Power Supply Units
I/O Control Unit
I/O Interface Unit
Memory Cards
Loop Control Board
50 blocks maximum including both adjustment and operation blocks CPU Unit Inner Board for CS1 Series
500 blocks maximum including both adjustment and operation blocks
Serial Communications
Boards
Programming Consoles
Model
CS1H-CPU67H
CS1H-CPU66H
CS1H-CPU65H
CS1H-CPU64H
CS1H-CPU63H
CS1G-CPU45H
CS1G-CPU44H
CS1G-CPU43H
CS1G-CPU42H
Specifications International standards
UC1, N, L, CE
UC1, N, L, CE
UC1, N, CE, L
U, C, N, L, CE
U, C, N, L, CE
U, C, N, L, CE
U, C, N, CE
U, C, N, CE
U, C
UC
UC1, L (approval pending), N, CE
U, C, CE
L, CE
CE
U, C, N, L, CE
U, C, N, CE
CS1H-CPU67H
CS1D-CPU67S
32 kW
A C200H Expansion Backplane can be used in addition to the above Backplanes.
Specifications and Models
CS1H-CPU66H CS1H-CPU65H
CS1D-CPU65S
CS1H-CPU64H CS1H-CPU63H CS1G-CPU45H CS1G-CPU44H
CS1D-CPU44S
CS1G-CPU43H CS1G-CPU42H
CS1D-CPU42S
Parallel peripheral service processing, constant (minimum) cycle time, cycle time monitoring, input time constant settings, debugging (online edit, error simulation, forced set
and reset, data trace, differential monitoring, etc.), program protection, diagnostic check, error history, clock,
power OFF detection delay time, remote programming and monitoring, eight-level communications, etc. (See note.)
Note: CPU Unit must be Unit Ver. 2.0 or later for 8 levels of communications (Pre-Ver. 2.0 CPU Units allow communications over three network levels).
CS1W-BC023
CS1W-BC033
CS1W-BC053
CS1W-BC083
CS1W-BC103
2 slots (Expansion I/O Units cannot be connected.)
3 slots
5 slots
8 slots
10 slots
CS1W-BC022
CS1W-BC032
CS1W-BC052
CS1W-BC082
CS1W-BC102
2 slots (Expansion I/O Units cannot be connected.)
3 slots
5 slots
8 slots
10 slots
CPU Unit
(with on-line replacement
capability)
CS1D-CPU67S
CS1D-CPU65S
CS1D-CPU44S
CS1D-CPU42S
5,120 I/O points
5,120 I/O points
960 I/O points
1,280 I/O points
448 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 13 banks)
128 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 3 banks)
64 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 1 bank)
64 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 1 bank)
250 Ksteps
60 Ksteps
10 Ksteps
30 Ksteps
CS1W-BI033
CS1W-BI053
CS1W-BI083
CS1W-BI103
3 slots
5 slots
8 slots
10 slots
CS1 Expansion
Backplanes
(for CS1 Units only)
CS1W-BI032
CS1W-BI052
CS1W-BI082
CS1W-BI102
3 slots
5 slots
8 slots
10 slots
CS1D CPU Backplane (with
on-line replacement capability)
CS1D Expansion Backplane
(with on-line replacement
capability)
CS1D-BC082S 8 slots (use together with the CS1D-CPU S)
CS1D-BI092
CS1D-PA207R
CS1D-PD024
CS1D-PD025
9 slots (use together with the CS1D-CPU S)
C200HW-PA204
C200HW-PA204S
C200HW-PA204R
C200HW-PA209R
C200HW-PD024
C200HW-PD025
C200HW-PD106R
100 to 120 VAC/200 to 240 VAC; Output capacity: 5 VDC at 4.6 A, 26 VDC at 0.625 A, total 30 W max.
100 to 120 VAC/200 to 240 VAC (with 24 VDC, 0.8-A service power supply); Output capacity: 5 VDC at 4.6 A, 26 VDC at 0.625 A, total 30 W ma
x.
100 to 120 VAC/200 to 240 VAC (with RUN output); Output capacity: 5 VDC at 4.6 A, 26 VDC at 0.625 A, total 30 W max.
100 to 120 VAC/200 to 240 VAC (with RUN output); Output capacity: 5 VDC at 9 A, 26 VDC at 1.3 A, total 45 W max.
24 VDC; Output capacity: 5 VDC at 4.6 A, 26 VDC at 0.625 A, total 30 W max.
24 VDC, Output capacity: 5 VDC at 5.3 A, 26 VDC at 1.3 A, total 40 W max.
100 VDC; Output capacity: 5 VDC at 6 A, 26 VDC at 1.0 A, total 30 W max.
UC1, N, L, CE
CS1W-IC102
CS1W-II102
For long distance expansion exceeding 12 m (50 m max.). (With 2 terminating resistors.)
For long distance expansion exceeding 12 m (50 m max.).
U, C, N, L, CE
UC1, N, L, CE
UC1, N, L, CE
UC1, N, CE
UC1, CE, N, L
UC1, L (approval pending), N, CE
CS1D Power Supply
Unit (with on-line
replacement capability)
100 to 120 V AC/200 to 240 V, 50/60 Hz (RUN output), output capacity: 5 V DC at 7 A,
26 V DC at 1.3 A, total 35 W max. (for both Duplex-CPU Systems and Single-CPU Systems)
24 V DC, Output capacity: 5 V DC at 4.3 A, 26 V DC at 0.56 A, total 28 W max. (for both Duplex-CPU Systems and Single-CPU Systems)
24 VDC, Output capacity: 5 VDC at 5.3 A, 26 VDC at 1.3 A, total 40 W max. (for both Duplex-CPU Systems and Single-CPU Systems)
CS1W-SCB21-V1
CS1W-SCB41-V1
CS1W-LCB01
CS1W-LCB05
CQM1-PRO01-E
C200H-PRO27-E
Two RS-232C ports
One RS-232C port and one RS-422/485 port
Console for on-site operation
Console for on-site operation
Product name
CX-One FA integrated Tool Package
CX-Programmer Ver. 6.
CX-Simulator Ver. 1.
Support Software
CX-Process Tool Ver. 4.
CX-Protocol Ver. 1.
CX-Motion Ver. 2.
CX-Position Ver. 2.
CX-Process Monitor Plus
Support Software for
Process I/O Unit
DeviceNet Configurator Software
CS1-series Basic I/O Units
Classification
Input Units
Output Units
I/O Units
Name
DC Input Unit
AC Input Unit
Interrupt Input Unit
High-speed Input Unit
Safety Relay Unit
Relay Contact Output Units
Transistor Output Unit
Triac Output Unit
Model
CS1W-ID211
CS1W-ID231
CS1W-ID261
CS1W-ID291
CS1W-IA111
CS1W-IA211
CS1W-INT01
CS1W-IDP01
CS1W-SF200
CS1W-OC201
CS1W-OC211
CS1W-OD211
CS1W-OD212
CS1W-OD231
CS1W-OD232
CS1W-OD261
CS1W-OD262
CS1W-OD291
CS1W-OD292
CS1W-OA201
CS1W-OA211
Specifications
7 mA, 24 VDC, 16 inputs
6 mA, 24 VDC, 32 inputs
6 mA, 24 VDC, 64 inputs
Approx. 5 mA, 24 VDC, 96 inputs
100 to 120 VAC, 100 to 120 VDC, 16 inputs
200 to 240 VAC, 16 inputs
7 mA, 24 VDC, 16 inputs
7 mA, 24 VDC, 16 inputs
24 VDC, 1 word/2 word shared input, 4 commons
2 A, 250 VAC, 2 A, 24 VDC, 0.1 A, 120 VDC max., independent contacts, 8 outputs
2 A, 250 VAC, 2 A, 24 VDC, 0.1 A, 120 VDC max., 16 outputs
0.5 A, 12 to 24 VDC, 16 sinking outputs
0.5 A, 24 VDC, 16 sourcing outputs, with load short-circuit protection and alarm function
0.5 A, 12 to 24 VDC, 32 sinking outputs
0.5 A, 24 VDC, 32 sourcing outputs, with load short-circuit protection and alarm function
0.3 A, 12 to 24 VDC, 64 sinking outputs
0.3 A, 24 VDC, 64 sourcing outputs, with load short-circuit protection and alarm function
0.1 A, 12 to 24 VDC, 96 sinking outputs
0.1 A, 12 to 24 VDC, 96 sourcing outputs
1.2 A, 250 VAC max., 8 outputs.
0.5 A, 250 VAC max., 16 outputs.
C200H and C200HW Basic I/O Units can be used in addition to the above Units.
International standards
UC1, N, L, CE
U, C, N, L, CE
UC, N, L, CE
UC, N, L, CE
UC1, N, L, CE
UC1, N, L, CE
U, C, CE
UC1, N, L, CE
UC1, N, L, CE
UC1, N, L, CE
U, C, N, CE
U, C, N, L, CE
UC, N, L, CE
CS1W-MD292
CS1W-MD561
CS1W-MD262
CS1W-MD261
CS1W-MD291
6 mA, 24 VDC, 32 inputs/0.3 A, 24 VDC, 32 sourcing outputs,
with load short-circuit protection and alarm function
5 VDC, 32 inputs, 32 outputs
Approx. 5 mA, 24 VDC, 48 inputs/ 0.1 A, 12 to 24 VDC, 48 sinking outputs
Approx. 5 mA, 24 VDC, 48 inputs/ 0.1 A, 12 to 24 VDC, 48 sourcing outputs
6 mA, 24 VDC, 32 inputs/ 0.3 A, 12 to 24 VDC, 32 sourcing outputs
TTL I/O Unit
Mixed I/O Units
DC Input/Transistor Outputs
Units
UC, N, L, CE
UC1, N, L, CE
U, C, N, L, CE
22 23
HMC-EF372
HMC-EF672
HMC-AP001
Flash memory, 30 Mbytes
Flash memory, 64 Mbytes
Memory Card Adapter (for PCMIA slot on personal computer)
5,120 I/O points
5,120 I/O points
5,120 I/O points
5,120 I/O points
5,120 I/O points
5,120 I/O points
1,280 I/O points
960 I/O points
960 I/O points
250 Ksteps
120 Ksteps
60 Ksteps
30 Ksteps
20 Ksteps
60 Ksteps
30 Ksteps
20 Ksteps
10 Ksteps
448 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 13 banks)
256 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 7 banks)
128 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 3 banks)
64 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 1 bank)
64 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 1 bank)
128 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 3 banks)
64 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 1 bank)
64 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 1 bank)
64 Kwords of data (DM: 32 Kwords, EM: 32 Kwords x 1 bank)
Item
Model One license
Three licenses
Ten licenses
One license
One license
Three licenses
Ten licenses
PLC programming software
OS: Windows 98SE, Me, NT4.0 (Service Pack 6a), 2000 (Service Pack 3 or higher), or XP
Ladder program simulation software
Support Software for Windows.
OS: Windows 98SE, Me, NT4.0 (Service Pack 6a), 2000 (Service Pack 3 or higher), or XP
Specifications
One license
Three licenses
Ten licenses
Loop Controller programming software
OS: Windows 98SE, Me, NT4.0 (Service Pack 6a), 2000 (Service Pack 3 or higher), or XP
One license Software to create protocol macros
OS: Windows 98SE, Me, NT4.0 (Service Pack 6a), 2000 (Service Pack 3 or higher), or XP
One license Motion Control Unit support software
OS: Windows 98SE, Me, NT4.0 (Service Pack 6a), 2000 (Service Pack 3 or higher), or XP
One license Position Control Unit support software
OS: Windows 98SE, Me, NT4.0 (Service Pack 6a), 2000 (Service Pack 3 or higher), or XP
Process I/O Unit Settings Software
OS: Windows 95, 98, NT4.0, 2000
DeviceNet Configuration Software
OS: Windows 95, 98, Me, NT4.0, 2000, XP
Loop Control Board, Unit Monitoring Software
OS: Windows 2000, NT4.0
CX-One is a package that integrates the Support Software for OMRON PLCs and components. CX-One
operates on the following OS
OS: Windows 98SE, Me, NT4.0 (service Pack 6a), 2000 (Service Pack 3 or higher), or XP.
CX-One includes CX-Programmer Ver. 6.@., CX-Simulator Ver. 1.@., CX-Protocol Ver. 1.@., CX-Motion
Ver. 2.@., CX-Position Ver. 2.@., CX-Process Tool Ver. 4.@
For details, refer to the CX-One Catalog (Cat. No. R134).
CX-One includes CX-Programmer, CX-Simulator, CX-Protocol, CX-Motion, CX-Position, and CX-Process
Tool can still be ordered individually using the following model numbers.
WS02-CXPC1-E-V6
WS02-CXPC1-E03-V6
WS02-CXPC1-E10-V6
WS02-SIMC1-E
WS02-PSTC1-E
CX-ONE-AL01C-E
CX-ONE-AL03C-E
CX-ONE-AL10C-E
WS02-LCTC1-EV4
WS02-LCTC1-EV4L03
WS02-LCTC1-EV4L10
WS02-MCTC1-EV2
WS02-NCTC1-EV2
WS02-LCMC1-E
WS02-PUTC1-E
WS02-CFDC1-E
Model
Product name Model
SCPL-SYSFL-2003E
SDKY-95HLK-E97
SDKY-95MLT-E97
SFGW-RT-2003
Specifications
Software for communications with OMRON PLCs
Simple Data Collection Software (host link version)
Simple Data Collection Software (multi-network version
Communications Middleware
Corresponding operating system
Windows2000/XP
Windows98/Me/2000/XP
Windows98/Me/2000/XP
Windows2000/XP
Middleware
SYSMAC Compolet Version 2003
PLC Reporter 32
FinsGateway Version 2003