Onyx BE185 User manual

Bedside Terminal ONYX-BE185
BE185
18.5” Bedside Terminal
Intel®ULV U7500 Processor
High Performance
Low Power Consumption
Wide LCD with Multimedia
BE185 Manual 2nd Edition
July. 2012

Bedside Terminal ONYX - BE185
Copyright Notice
This document is copyrighted, 2012. All rights are reserved. The
original manufacturer reserves the right to make improvements to
the products described in this manual at any time without notice.
No part of this manual may be reproduced, copied, translated, or
transmitted in any form or by any means without the prior written
permission of the original manufacturer. Information provided in
this manual is intended to be accurate and reliable. However, the
original manufacturer assumes no responsibility for its use, nor
for any infringements upon the rights of third parties, which may
result from its use.
The material in this document is for product information only and
is subject to change without notice. While reasonable efforts have
been made in the preparation of this document to assure its
accuracy, ONYX Healthcare Inc., assumes no liabilities resulting
from errors or omissions in this document, or from the use of the
information contained herein
ONYX Healthcare Inc. reserves the right to make changes in the
product design without notice to its users

Bedside Terminal ONYX - BE185
Acknowledgments
Intel®Core™2 Duo U7500 is a registered trademarks of Intel
®Corporation.
IBM, PC/AT, PS/2 are trademarks of International Business
Machines Corporation.
Microsoft®Windows is a registered trademark of Microsoft®
Corporation.
RTL is a trademark of Realtek Semi-Conductor Co., Ltd.
C&T is a trademark of Chips and Technologies, Inc.
UMC is a trademark of United Microelectronics Corporation.
ITE is a trademark of Integrated Technology Express, Inc.
SiS is a trademark of Silicon Integrated Systems Corp.
VIA is a trademark of VIATechnology, Inc.
All other product names or trademarks are properties of their
respective owners.

Bedside Terminal ONYX - BE185
Packing List
Before you begin installing your Bedside Terminal, please make
sure that the following items have been shipped:
BE185 Bedside Terminal.
VESAMount Screws
Utility CD-ROM (Please insert the ONYX-BE185 CD-ROM into
external CD-ROM drive.) which contains User’s Manual (in
PDF format), Drivers and Utilities
If any of these items are missing or damaged, you should contact
your distributor or sales representative immediately.
Headquarters
Onyx Healthcare Inc.
2F, No.135, Lane 235, Pao-Chiao Rd.,
Hsin-Tien City, Taipei 231, Taiwan, R.O.C.
TEL: +886-2-8919-2188
FAX: +886-2-8919-1699
E-mail: sales@onyx-healthcare.com
http://www.onyx-healthcare.com

Bedside Terminal ONYX - BE185
Worldwide Offices:
Onyx Healthcare, USA Inc.
2663 Saturn St. Brea, CA 92821, USA
Tel : +1-714-996-1800
Fax: +1-714-996-1811
Email: usasales@onyx-healthcare.com
Onyx Healthcare EUROPE B.V.
Ekkersrijt 4002, 5692 DA Son, The Netherlands
Tel : +31-(0)499-462020
Fax: +31-(0)499-462010
Email: eusales@onyx-healthcare.com
Onyx Healthcare Technology GmbH
An der Trift65d
63303 Dreieich , Germany
TEL: +49-(0)61033-7479-00
Fax: +49-(0)61033-7479-49
Email: eusales@onyx-healthcare.com

Bedside Terminal ONYX - BE185
Onyx Healthcare (SU ZHOU) INC.
Room 12, 2F, Building B, No.5 Xing Han Street, Suzhou Industrial
Park, Jiang Su Province, China
Tel: +86-512-67625700
Fax: +86-512-67617337
Email: cnsales@onyx-healthcare.com
Onyx Healthcare Singapore PTE LTD
57 Genting Lane, #07-00, Singapore 349564
Tel: +65-67498749
Fax +65-67461595
Email: sgsales@onyx-healthcare.com

Bedside Terminal ONYX - BE185
Safety & Warranty
1. Read these safety instructions carefully.
2. Keep this user's manual for later reference.
3. Disconnect this equipment from any AC outlet before cleaning. Do not
use liquid or spray detergents for cleaning. Use a damp cloth.
4. For pluggable equipment, the power outlet must be installed near the
equipment and must be easily accessible.
5. Keep this equipment away from humidity.
6. Put this equipment on a reliable surface during installation. Dropping it
or letting it fall could cause damage.
7. The openings on the enclosure are for air convection. Protect the
equipment from overheating. DO NOT COVER THE OPENINGS.
8. Make sure the voltage of the power source is correct before
connecting the equipment to the power outlet.
9. Position the power cord so that people cannot step on it. Do not place
anything over the power cord.
10. All cautions and warnings on the equipment should be noted.
11. If the equipment is not used for a long time, disconnect it from the
power source to avoid damage by transient over-voltage.
12. Never pour any liquid into an opening. This could cause fire or
electrical shock.
13. Never open the equipment. For safety reasons, only qualified service
personnel should open the equipment.

Bedside Terminal ONYX - BE185
14. If any of the following situations arise, get the equipment checked by
service personnel:
a. The power cord or plug is damaged.
b. Liquid has penetrated into the equipment.
c. The equipment has been exposed to moisture.
d. The equipment does not work well, or you cannot get it to
work according to the user’s manual.
e. The equipment has been dropped and damaged.
f. The equipment has obvious signs of breakage.
15. DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED
ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS
BELOW -20° C (-4°F) OR ABOVE 60° C (140° F). IT MAY DAMAGE
THE EQUIPMENT.
16. External equipment intended for connection to signal
input/output or other connectors, shall comply with relevant UL /
IEC standard (e.g. UL 1950 for IT equipment and UL 60601-1 /
IEC 60601 series for systems – shall comply with the standard
IEC 60601-1-1, Safety requirements for medical electrical systems.
Equipment not complying with UL 60601-1 shall be kept outside
the patient environment, as defined in the standard.
17. Unplug the power cord from the power adapter jack to disconnect the
device.

Bedside Terminal ONYX - BE185
Caution:
It may cause the danger of explosion if battery is incorrectly
replaced. Replace only with same or equivalent type recommended
by the manufacturer.

Bedside Terminal ONYX - BE185
Classification
1. Degree of production against electric shock: not classified
2. Equipment not suitable for use in the presence of a flammable
anesthetic mixture with air or with oxygen or nitrous oxide.
3. Mode of operation: Continuous
4. Type of protection against electric shock: Class I equipment
5. Class I: No Applied part, No AP / APG

Bedside Terminal ONYX - BE185
FCC
This device complies with Part 15 FCC
Rules. Operation is subject to the
following two conditions: (1) this device
may not cause harmful interference, and (2)
this device must accept any interference
received including interference that may
cause undesired operation.

Bedside Terminal ONYX - BE185
UL Module Description
BE185 AC modules are developed to suitable
for the Classification Mark requirement

Bedside Terminal ONYX - BE185
Safety Symbol Description
The following safety symbols are the further explanations for your
reference.
Medical equipment with respect to electric
shock, fire and mechanical hazards only in
accordance with UL 60601-1, and
CAN/CSA C22.2 NO. 601.1
Attention, consult ACCOMPANYING
DOCUMENTS.
Ground wire
Protective Ground wire.
Medical equipment with respect to electric
shock, fire and mechanical hazards only in
accordance with UL 60601-1, and
CAN/CSA C22.2 NO. 601.1

Bedside Terminal ONYX - BE185
Contents
Chapter 1 General Information
1.1 Introduction ....................................................................1-2
1.2 Feature ............................................................................1-3
1.3 Specification...................................................................1-4
1.4 Dimension.....................................................................1-10
Chapter 2 Hardware Installation
2.1 Safety Precautions.........................................................2-2
2.2 A Quick Tour of the BE185............................................2-3
2.3 Mounting Installing........................................................2-6
Chapter 3 Award BIOS Setup
3.1 System Test and Initialization.......................................3-2
3.2 Award BIOS Setup. ........................................................3-3
3.3 Standard CMOS Features..............................................3-5
3.4 Advanced BIOS Features..............................................3-5
3.5 Advanced Chipset Features..........................................3-5
3.6 Integrated Peripherals...................................................3-5
3.7 Power management Setup............................................3-6
3.8 PnP/PCI configuration...................................................3-6
3.9 PC Health Status ............................................................3-6
3.10 Frequency/Voltage control..........................................3-6
3.11 Load Fail-Safe Defaults ...............................................3-6
3.12 Load Optimized Defaults.............................................3-7

Bedside Terminal ONYX - BE185
3.13 Set Supervisor/User Password...................................3-7
3.14 Save & Exit Setup.........................................................3-8
3.15 Exit without saving ......................................................3-8
Chapter 4 Driver Installation
4.1 Installation ......................................................................4-3
Appendix A I/O Information
A.1 I/O Address Map ...........................................................A-2
A.2 Memory Address Map..................................................A-3
A.3 IRQ Mapping Chart.......................................................A-4
A.4 DMA Channel Assignment ..........................................A-4
Appendix B Miscellanea
B.1 General Cleaning Tips..................................................B-2
B.2 Cleaning Tools..............................................................B-3
B.3 Scrap Computer Recycling ........................................B-5

Bedside Terminal ONYX-BE185
Chapter 1 General Information 1-1
General
Information
Chapter
1

Bedside Terminal ONYX-BE185
Chapter 1 General Information 1-2
1.1 Introduction
—A bedside terminal solution for ultimate patient services that
boosts patient satisfaction and well-beings.
BE185 offers a highly scalable bedside infotainment solution to
enhance patient experiences within the hospital. Packaged with
renowned software solution partners, ONYX-BE185 bedside
terminals provide patients with capabilities like Entertainment on
Demand, Online Access, VoIP Phone, Nurse Notification, etc.
Clinical Applications
Ward, Nursing Station/Cart
Service Capabilities – BE185
Hospital Information Access –
Patient Record Access
Treatment Progress Reporting (i.e. Medical Charting)
Dietary/Meal Ordering Service
Monitoring/Communication –
Doctor Consultation by Video Conference
Internet Access
VoIP Telephone Access
Entertainment on Demand
Video-on-Demand

Bedside Terminal ONYX-BE185
Chapter 1 General Information 1-3
TV/Radio Broadcasting
1.2 Feature
18.5” Wide Color TFT LCD display
Intel® Core™ 2 Duo U7500 Processor
Fanless & Compact Design
VoIP phone, Web Camera, and High Quality Speaker
Optional Features:
- Analog Phone, Magnetic Stripe reader
- RFID / 2nd Smart Card Reader / Barcode Scanner
- Nurse Notification / HD Decoding Function
- Bluetooth / WLAN b/g/n
Multimedia Entertainment: TV, Game, VoIP, Web Radio

Bedside Terminal ONYX-BE185
Chapter 1 General Information 1-4
1.3 Specification
Model Number
ONYX-BE185
Model Description
18.5” Intel® Core™ 2 Duo High Performance Bedside Terminal with
Multimedia
Main Specification
CPU Processor Intel® Core™ 2 Duo U7500 1.06GHz Processor
LCD Controller Intel®945GME, Shared memory up to 224MB
System Memory Up to 2GB DDRII 533/667
Display BE185: 18.5” Wide Color TFT LCD with WLED
Backlight
OS Support
Windows® 7 (32 bit & 64 bit )
Windows® XP Pro
Windows® XP Embedded
Linux Fedora Core
Expansion
2 x Internal Mini Card
Magnetic Stripe Reader (Optional)
Barcode Scanner (Optional)
VoIP Phone
Web Camera
Main Specification (Cont.)
Storage Disk Drive 1 x 2.5” HDD (SATA)
1 x Compact Fast

Bedside Terminal ONYX-BE185
Chapter 1 General Information 1-5
1 x Smart Card Reader
1 x 2nd Smart Card Reader/RFID Module
(Optional)
Button
Volume +
Volume –
Brightness +
Brightness –
LCD On/Off
Programmable Function Key
Accessory
1 x Web Camera (1.3M Pixel)
2 xAlarm Light (Can be removed by request)
1 x Nurse Notification Connector (optional)
1 x Buzzer (GPIO Controllable – On/Off/Volume)
Accessory (Optional)
1 x MSR (RS-232 Interface)
1 x Bottom Barcode Reader (TTL Interface)
1 x RFID (USB Interface shared with Smart Card
Reader)
Support Content IP TV, Web Gaming, MPEG 2/3/4, Web Radio
I/O
Audio 1 x Line out / MIC in/Internal MIC
USB 2 x External USB2.0 on bottom I/O
5 x Internal USB2.0 pin header
Serial port Internal COM 1: 1 x RS-232 (Internal pin header)
Internal COM 2: 1 x TTL Uart (for Barcode Reader)
Table of contents
Other Onyx Touch Terminal manuals