Openpath ACU-4W User manual

OPENPATH
ACCESS CONTROL SYSTEM
INSTALLATION GUIDE
V1.2
Version 1.2
©
Openpath 2018
CONFIDENTIAL

Openpath Access Control System Installation Guide
GETTING STARTED
ADDITIONAL RESOURCES
PRIOR TO INSTALLATION
Installation
NETWORK REQUIREMENTS
SELECTING A BACKUP BATTERY
RECOMMENDED CONFIGURATION
WIRING THE REX WITH THE DOOR STRIKE
WIRING THE REX WITH THE ELECTROMAGNETIC LOCK
WIRING FAIL SAFE AND FAIL SECURE LOCKING HARDWARE
WIRING TO LEGACY PANELS
Troubleshooting
LEGACY WIRING
ACU LEDS
READER LEDS
RESETTING THE ACU
PROVISIONING THE ACU
Version 1.2
©
Openpath 2018
CONFIDENTIAL

Openpath Access Control System Installation Guide
GETTING STARTED
This Installation Guide explains how to install and configure Openpath Smart Hubs (ACUs) and
Openpath Smart Readers as part of an Openpath Access Control system.
ADDITIONAL RESOURCES
For more information, refer to the Smart Reader Data Sheet and Smart Hub (ACU) Data Sheet.
PRIOR TO INSTALLATION
Prior to installing Openpath hardware, it is assumed that you have performed a customer site
survey and have determined the following:
●How many entries need to be configured (e.g. doors, gates, and/or elevator floors)
●Whether you’re using legacy wiring or new wiring
●What kind of electronic entry mechanisms, Request to Exit (REX) mechanisms, and door
contact sensors will be used and their power requirements. If your locking hardware requires
24V DC, either use the Smart Hub ACU with included 24V power supply (SMART
HUB-ACU-4WDP) or use a separate 24V supply.
○NOTE: The Smart Hub ACU with 12V power supply (SMART HUB-ACU-4W) supports up
to 2A for locking hardware.
●Whether you’re providing backup batteries for the ACUs. See SELECTING A BACKUP BATTERY.
●Whether you’re supporting a legacy access control panel. See WIRING TO LEGACY PANELS.
Installation
NETWORK REQUIREMENTS
An Ethernet connection with DHCP must be used to connect the ACU to the Local Area Network
(LAN). You also need to configure firewall settings to communicate with the Openpath system.
Openpath uses the following outbound ports:
●TCP port 443
Version 1.2
©
Openpath 2018
CONFIDENTIAL

●TCP port 80
●TCP port 8883
●UDP port 123
NOTE: If using an external DNS server, outbound UDP port 53 must also be open.
To support Wi-Fi unlocking from the mobile app, inbound TCP port 443 must be available from
within the LAN. Inbound port forwarding on the router, firewall, or NAT device is not required.
SELECTING A BACKUP BATTERY
While not required, Openpath recommends having a backup battery in the case of power outages.
The size of battery depends on your setup and how long you want to power the system.
Table 1: Power requirements (12V)
Smart Hub ACU
1A
Smart Reader
0.25A
Locking hardware
(while engaged)
0.25A – 0.5A
Assuming a 12V power supply, a Smart Hub ACU configured with four Openpath readers and
locking hardware uses 4 Amps per hour. To keep the system running for 3 hours with all entries
engaged, you’d need a 12V 12A sealed lead acid (SLA) battery.
RECOMMENDED CONFIGURATION
Openpath readers and ACUs communicate via RS-485. The following wire types are compatible,
listed in the order of preference which impacts distance.
●Shielded CAT6A (recommended, additional two pairs can be used for sensors)
●Shielded CAT6
●Shielded RS485 w/22-24AWG (lower gauge, thicker wire is better)
●Shielded CAT5
●Unshielded CAT6
●Unshielded CAT5
●Shielded 22/6
●Unshielded 22/6
Version 1.2
©
Openpath 2018
CONFIDENTIAL

Ideally, use one twisted pair for GND and VIN (power) and one twisted pair for +B and -A (data).
For shielded wiring, we recommend that you connect only one side of the drain wire (the shield
around the wires) to the GND terminal on the ACU. Both the shield and the GND wire can share the
same GND terminal. Do not connect the other side of the shield to anything.
For reader installation, we recommend that you install a 1-Gang 20 CU box in order to flush-mount
the reader. Alternatively, the reader may also be surface mounted with the included back plate.
NOTE: For elevators, all relays must be on the same ACU. If you need more than four access
controlled floors, use our elevator expansion board.
Version 1.2
©
Openpath 2018
CONFIDENTIAL

WIRING THE REX WITH THE DOOR STRIKE
Version 1.2
©
Openpath 2018
CONFIDENTIAL

WIRING THE REX WITH THE ELECTROMAGNETIC LOCK
Version 1.2
©
Openpath 2018
CONFIDENTIAL

WIRING FAIL SAFE AND FAIL SECURE LOCKING HARDWARE
Fail safe and fail secure are ways of configuring locking hardware:
●Fail safe hardware unlocks when power is interrupted
●Fail secure hardware locks when power is interrupted
Version 1.2
©
Openpath 2018
CONFIDENTIAL

WIRING TO LEGACY PANELS
To support a legacy access control system, install the ACU between the Openpath readers and the
legacy panel, with the ACU Wiegand port configured as output to the legacy panel. Replace low
frequency (LF) Wiegand readers with LF Openpath readers and high frequency (HF) Wiegand
readers with HF Openpath readers. In this setup, the legacy panel controls all locking hardware and
entry mechanisms while the Openpath system allows you to use the Openpath mobile app, Smart
reader, and Touch functionality.
Version 1.2
©
Openpath 2018
CONFIDENTIAL

Troubleshooting
LEGACY WIRING
ACU LEDS
READER LED
PROVISIONING THE ACU
RESETTING THE ACU
LEGACY WIRING
Sometimes legacy wiring (unshielded and straight through, rather than shielded twisted pair, often
22-6) used with reader results in slower connections and dropped packets between the Openpath
Reader and Smart Hub. To remedy this, you can switch GND and VIN with +B and -A connections on
the ACU and readers to ensure the data pair (+B and -A) are using the alternate pair of legacy wires.
ACU LEDS
Version 1.2
©
Openpath 2018
CONFIDENTIAL

The Openpath ACU has several LEDs that indicate the following:
●POWER LEDs indicate that the ACU is connected to power
●The four RELAY LEDs indicate when the relays are activated
●The STATUS LED in the center of the ACU indicates that the ACU has been configured with
firmware
●The four READER POWER LEDs indicate that the ACU has output power enabled per reader
READER LEDS
The Openpath Smart Reader’s LEDs indicate the following:
●If the center dot quickly switches between multiple colors and outer ring quickly spins once,
the reader has just received power
●If all lights are off, the reader is not connected to power (check to see if the power wires are
swapped)
●If the center dot is flashing red, the reader is connected to power but cannot communicate with
the ACU (check to see if the +B and -A lines are swapped)
●If the center dot is solid blue, the reader is connected to power and can communicate with the
ACU, but has not been configured as an entry in the online portal
●If the center dot is solid green, and the outer ring lights up and spins, that means the reader has
been identified via the Control Center.
●If the center dot is solid white, then the door is locked
●If the outer ring is solid white, then the door is unlocked
RESETTING THE ACU
Soft Reset: To soft reset the ACU, disconnect power from the ACU, wait 10 seconds, then reconnect
the power.
WARNING: Only hard reset the ACU if absolutely necessary and if instructed by Openpath. This
will clear all of the data off of the ACU and will require reprovisioning, which requires having a
computer or mobile phone on the same network as the ACU.
Hard Reset: To hard reset the ACU, disconnect power from the ACU, hold down the ADMIN
BUTTON, reconnect power to the ACU, wait 20 seconds while still holding the button down, then
Version 1.2
©
Openpath 2018
CONFIDENTIAL

release the button. Wait 10 minutes before re-provisioning the ACU following the PROVISIONING
THE ACU steps below.
PROVISIONING THE ACU
Provisioning the ACU means registering it in the online portal and getting it up and running with
the latest firmware. ACUs are shipped already provisioned, but below are instructions for this
process in the case of RESETTING THE ACU.
To provision the ACU:
1. Connect the ACU to the Internet via Ethernet
2. Press the ADMIN BUTTON
3. On a computer or mobile phone on the same network as the ACU, go to
https://control.openpath.com
4. Log in with your administrative login
5. Go to Hardware > ACU Management
6. Locate the ACU on the list and click Register
7. A new window will open with instructions on registering the ACU. Click Yes to proceed.
Version 1.2
©
Openpath 2018
CONFIDENTIAL
This manual suits for next models
2
Table of contents
Other Openpath Control System manuals
Popular Control System manuals by other brands

Roger
Roger MCT68ME-IO operating manual

Andatech
Andatech ACCESSPOINT FRX user manual

Micronix
Micronix MMC-100 Series quick start guide

Roger Technology
Roger Technology Agilik AG/004 Use and maintenance manual

National Instruments
National Instruments FOUNDATION NI-FBUS Hardware and Software User Manual

Techno
Techno THP387 manual

Perrot
Perrot Greenkeeper Feedback user manual

OBSIDIAN CONTROL SYSTEMS
OBSIDIAN CONTROL SYSTEMS NETRON DMX10 installation guide

Elstat
Elstat ems75vr Installation and user guide

sauter
sauter eValveco UVC106MF015 Fitting instructions

Jazz
Jazz JZ20-T10 user guide

WAREMA
WAREMA Quatronic dialog operating instructions