manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Opticon
  6. •
  7. Barcode Reader
  8. •
  9. Opticon M-5 User manual

Opticon M-5 User manual

Other Opticon Barcode Reader manuals

Opticon LGZ 7225 User manual

Opticon

Opticon LGZ 7225 User manual

Opticon OPL 7836 User manual

Opticon

Opticon OPL 7836 User manual

Opticon PX-35 User manual

Opticon

Opticon PX-35 User manual

Opticon NFT 2100 User manual

Opticon

Opticon NFT 2100 User manual

Opticon CS1504 User manual

Opticon

Opticon CS1504 User manual

Opticon RS232 User manual

Opticon

Opticon RS232 User manual

Opticon PHL 2700 User manual

Opticon

Opticon PHL 2700 User manual

Opticon OPR 3101 User manual

Opticon

Opticon OPR 3101 User manual

Opticon OPN-3102i User manual

Opticon

Opticon OPN-3102i User manual

Opticon OPR 2001 User manual

Opticon

Opticon OPR 2001 User manual

Opticon M-5 User manual

Opticon

Opticon M-5 User manual

Opticon N LB 9625 Series User manual

Opticon

Opticon N LB 9625 Series User manual

Opticon OPL 2724 ZAPPER Operator's manual

Opticon

Opticon OPL 2724 ZAPPER Operator's manual

Opticon C 37 User manual

Opticon

Opticon C 37 User manual

Opticon OPR 3001 User manual

Opticon

Opticon OPR 3001 User manual

Opticon UNIVERSAL MENU BOOK Installation instructions

Opticon

Opticon UNIVERSAL MENU BOOK Installation instructions

Opticon OPL 972 Series User manual

Opticon

Opticon OPL 972 Series User manual

Opticon LPN 1736 User manual

Opticon

Opticon LPN 1736 User manual

Opticon OPL 2724 ZAPPER User manual

Opticon

Opticon OPL 2724 ZAPPER User manual

Opticon OPI 4002 User manual

Opticon

Opticon OPI 4002 User manual

Opticon LH2 User manual

Opticon

Opticon LH2 User manual

Opticon LPN5627 User manual

Opticon

Opticon LPN5627 User manual

Opticon OPL-9725 User guide

Opticon

Opticon OPL-9725 User guide

Opticon CRD972X User manual

Opticon

Opticon CRD972X User manual

Popular Barcode Reader manuals by other brands

Microscan HS-2D user manual

Microscan

Microscan HS-2D user manual

SICK CLV62x Online help

SICK

SICK CLV62x Online help

Datalogic Gryphon GBT4200 Quick reference guide

Datalogic

Datalogic Gryphon GBT4200 Quick reference guide

WaveMark SmartWand SW1500 manual

WaveMark

WaveMark SmartWand SW1500 manual

Zebex Z-3191BT Quick connection guide

Zebex

Zebex Z-3191BT Quick connection guide

RTscan RT211 Integration guide

RTscan

RTscan RT211 Integration guide

Motorola SYMBOL DS6707 Product reference guide

Motorola

Motorola SYMBOL DS6707 Product reference guide

Godex BP300 user manual

Godex

Godex BP300 user manual

Godex RT800i Series user manual

Godex

Godex RT800i Series user manual

Generalscan X Series quick start guide

Generalscan

Generalscan X Series quick start guide

POSMicro Datalogic PowerScan D7100 manual

POSMicro

POSMicro Datalogic PowerScan D7100 manual

NCR RealPOS user guide

NCR

NCR RealPOS user guide

Motorola SE3300 Integration guide

Motorola

Motorola SE3300 Integration guide

Nordson CBC 5100 manual

Nordson

Nordson CBC 5100 manual

Motorola Symbol LS3008 Product reference guide

Motorola

Motorola Symbol LS3008 Product reference guide

Meec tools OBD-II / VAG operating instructions

Meec tools

Meec tools OBD-II / VAG operating instructions

SICK CLP 100 operating instructions

SICK

SICK CLP 100 operating instructions

Royal Tag SA I-Read user manual

Royal Tag SA

Royal Tag SA I-Read user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

M-500009062-0-00
The Netherlands Opticon Sensors Europe B.V.
tel: +31 (0)23-5692700 / email: [email protected]
U.S.A. Opticon Inc.
tel: 800-636-0090 / email: [email protected]
France Opticon S.A.S.
tel: +33 (0)1-41461260 / email: [email protected]
Germany Opticon Sensoren GmbH
tel: +49 (0)6074-91890-0 / email: sales.de@opticon.com
Italy Opticon s.r.l.
tel: +39 (0)051-6321800 / email: opticon@opticonitalia.it
Spain Opticon Sensores S.L.
tel: +34 (0)902-747469 / email: [email protected]
Contact
Sweden Opticon Sensors Nordic AB
tel: +46 (0)8-58548560 / email: henrik@opticon-sensors.se
United Kingdom Opticon Limited
tel: +44 (0)1582-635100 / email: [email protected]
Taiwan Opticon Far Eastern Ltd.
tel: +886 2-27597444 / email: [email protected]
China
Opticon Sensors Europe B.V., Shanghai Representative Oce
tel: +86 21-64480881 / email: [email protected]
Australia Opticon Sensors Pty. Ltd.
tel: +61 (0)2-43402666 / email: [email protected]
Brazil Opticon Sensors Europe B.V., Latin American Oce
tel: +55 11-5081 2088 / email: [email protected]
Please contact OPTICON or your local dealer.
More product details, additional support, and configuration options (from the Universal Menu Book) are available at www.opticon.com.
Notice
• This quick start guide may be revised or withdrawn at any time without prior notice.
• This quick start guide may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any
electronic or machine readable form without prior written consent of Opticon.
• Trademarks used are property of their respective owners.
• Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or indirect
damages howsoever caused.
Precautions for Use
1. LED Safety
Do not stare into the LEDʼs.
2. Handling Instructions
【M-5】
• Do not attempt to disassemble, modify or update this device.
• Do not use the scanner while operating machinery.
• Do not drop or put heavy items on this product or its cable.
• Do not pinch or forcibly bend the cable, especially at very low temperature.
• Do not insert foreign substances into the device.
• Do not use/leave this device:
- In areas exposed to direct sunlight for long periods of time
- In dusty environments
- In risk for an exposure to chemicals
- Near water or other liquids, as well as in extremely high humidity
- Near heat sources such as radiators, heat registers, stoves, or other types of devices that produce heat
- Near microwaves, medical devices, or RF-emitting devices
- In the reach of blinking lights such as CRT
• Do not use this product during a lightning storm.
【AC/DC Adapter】
• Use only the supplied AC adapter with the enclosed region specific plugs for connection to the wall socket.
• This product may produce heat when in use, but it does not affect its performance.
• Do not pull on the cord when unplugging the power cord from a power outlet. Grasp the plug to remove it.
• Do not plug in or out this product with wet hands.
• Unplug this product when it is not in use or when it is being cleaned.
Quick Start Guide
Introduction
M-5
Copyright©2009, Opticon All rights reserved.
                      
Setting Menu Codes
The M-5 can be configured by reading the menu codes below. Read more about configuration options
(by Opticonfigure) on www.opticon.com.
■Detailed View
Overview
■M-5 Basic Specifications
Parameter Specifications
Physical
Features
Size (H)140.0 ×(W)92.0 ×(D)95.5 mm
Weight Approx.295g (excluding the cable)
Operation
Section
Scan Confirmation
Buzzer and 3 colors LED(Green/Blue/Orange)
Keys 2 keys (Trigger Switch/Mode Switch)
Interfaces
RS-232C 9600bps 〜115.2kbps
USB Full-Speed 12Mbps(HID/VCP)
Hi-Power Bus-powered
Wedge
PS/2 Keyboard (Connect or disconnect the keyboard.)
Control
Section
ASIC
OEY-0603 CPU:ARM-1026EJ-S Core:160MHz
SDRAM 128Mbits(1M ×4Banks ×32Bits)
Flash ROM 16Mbits(1M ×16Bits) Flash Memory
Scanning
Section
Light Source
Wavelength
8-AllnGaP Red LEDs(Omniscan Mode)/625nm
4-AllnGaP red LEDs (Mobile Mode)/633nm
Scanning Method
WVGA(752 x 480 pixels) CMOS area sensor
Supported
Symbologies
(1D)
UPC-A,UPC-E, UPC-E1, UPC-A Add-on, UPC-E Add-on, EAN-13,
EAN-8, EAN-13 Add-on/EAN-8 Add-on, JAN-8 , JAN-13, Code
39,Tri-Optic, NW-7, Industrial 2 of 5, Interleaved 2 of 5, Code 93,
Code 128, GS1-128, S-Code, MSI/Plessey, UK/Plessey, TELEPEN,
Matrix 2 of 5, Chinese Post Matrix 2 of 5, IATA,Code 11,
Korean Postal Authority code , GS1 DataBar, Postal Code
Supported
Symbologies
(2D)
PDF417,MicroPDF417, QR Code,MicroQR Code,Data
Matrix (ECC 000-140/ECC 200),MaxiCode (Modes 2 to 5),
Aztec Code, EAN.UCC Composite bar code, Codablock F
Power
Supply
Section
Operating voltage
4.5 to 6.6V
Current
consumption
USB
RS-232C,Wedge
Peak
(when scanning and decoding)
420mA 400mA
Average
(when scanning and decoding)
280mA(typ)
210mA (typ)
Stand-by
140mA(typ)
130mA(typ)
Durability
Operating Temp.
0 to 40 deg. C
Storage Temp.
−40 to 70 deg. C
Operating Humidity
5 to 95%(non-condensing)
Storage Humidity
5 to 95%(non-condensing)
Ambient
Light
Immunity
Fluorescent:10,000lx or less
Incandescent lamp:10,000lx or less
Sunlight
:
50,000lx or less (*1)
Dust-and-Drip Proof
IP52
Static Electricity
15kV (no destruction)
Shock
Endurance
Dropped once from each of 5 angles onto
concrete floor from a height of 150cm with
no defects found. (Total 5 times)
No. Part Function
①
Optical Window
−−−−−−−−−−−
②Trigger Switch
The trigger switch is used for the manual
scanning operation. A single aiming guide
will be activated in this mode.
③
Mode Switch
The mode switch toggles between Mobile phone
scanning mode and Normal scanning mode.
④Indicator LED
Green LED light shows the scanning
operation has been successful.
Blue LED light shows when the scanner is
ready to scan.
⑤
Indicator LED While Mobile
phone scanning Mode
Orange LED light shows when the scanner
is ready for mobile code scanning.
⑥Buzzer Holes
−−−−−−−−−−−
⑦Screw Holes
Used to mount the scanner onto a base plate,
wall etc. using D4 (diameter: 4mm) screws.
①
⑦
②
③
⑥
⑤④
Before Getting Started
No. Item Function Notes
1Scanner An omnidirectional imaging scanner
−−−−−−−−−−−
2Interface cable A cable for connecting the scanner Different for each interface spec.
3Wedge branch cable Y-cable: The cable that can be used to connect a keyboard
and the scanner's straight cable to a host computer. Only for Wedge interface.
4Connector cover A cover used to fix the connection between the
Y-cable and the straight cable. Only for M-5-WEDGE+PS package.
5
Instruction of connector cover
An instruction manual for the connector cover Only for M-5-WEDGE+PS package.
6AC adapter AC adapter with interchangeable plugs
Only for RS-232C and
Wedge
interface.
7Interchangeable plugs Plugs for different regions
Only for RS-232C and
Wedge
interface.
8Quick start guide This manual provides the basic product specification
and setup instructions.
−−−−−−−−−−−
■What's in the Box
Confirm that you have the following items before getting started. Please note that the contents may differ
depending on interface specifications. Please contact the nearest dealer if items are damaged or missing.
■Various Scanning Modes
The following modes are available for different uses:
□Normal scanning mode
A mode in which the scanner is configured optimally for general barcode
reading. The device automatically starts scanning when a label is
held in front of it. The trigger key activates the single line scanning.
□Mobile phone scanning mode
A special mode ―in which the lighting conditions are optimized for
reading barcodes,―displayed on mobile devices such as a phone.
The device automatically starts scanning when a label is held in front
of it. The trigger key activates the single line scanning.
□Single line scanning
While the trigger switch is pressed, the illumination LEDs turn on
and only one code can be read. The single line can read one target
code out of multiple printed codes in this mode.
                      
Setting Menu Codes
(*1)Except
“
Mobile phone scanning mode
”
in each condition. Please note that scanning while the
LCD screen is exposed to direct sunlight may have a negative effect on the reading performance.
Figure 1. Scanning mode diagram
Normal scanning
mode
Mobile phone
scanning mode
Mode Switch
Power
ON
Singleline
scanning
Trigger
Switch
Finished Scanning
or Time-Out
■
Basic Specifications for Universal AC adapter
Parameter Specifications
Physical
Features
Size
(H)75 x (W)47.5 x (D)28mm (excluding boss)
Cable Length 1.8m
Colour Black
Input
Power Voltage
AC 90V to 265V
Supply Current
500mA Max
Output
Power Voltage
5.7V to 6.3V
Maximum Current
2A Max
Environmental
Specification
Operating Temp.
0 to 40 deg. C
Operating Humidity
25 to 85% (non-condensing)
Storage Temp.
−20 to 60 deg. C
Storage Humidity
20 to 90% (non-condensing)
Trigger
Switch
Finished Scanning
or Time-Out
: Default
Default Setting
■Enable QR Code
(* Use this only when “Disable QR Code”is set in advance.)
Start / END: ZZ
Enable QR Code: BCD
Stop / END: ZZ
■Back to default
Serial command : U2, C01, SU, UB
"Normal scanning mode" or "Mobile phone scanning mode"
can be selected as primary mode when the scanner starts up.
Scanning Mode Setting
■Normal scanning mode
Serial command : E8Y
■Mobile phone scanning mode
Serial command : E8Z
Auto trigger ON / OFF can be set. When it is set to OFF, only
the trigger switch can be used to activate the scanner.
Auto Trigger Setting
■Auto Trigger OFF
■Auto Trigger ON
Serial command : +I
Serial command : +F
You can set the time that the scanner will try to read a code
after it is detected by the auto trigger. This can be set for
“
Nor-
mal scanning mode
”
and
“
Mobile phone scanning mode
”
.
For single line scanning, it can be set as the LED aiming time.
Read Time Setting
■Normal scanning mode
Serial command : Y0 (0.5s) Serial command : Y2 (2.0s)
Serial command : Y1 (1.0s) Serial command : Y3 (3.0s)
■Mobile phone scanning mode
Serial command : E91 (1s) Serial command : E93 (3s)
Serial command : E92 (2s) Serial command : E94 (4s)
■Single line scanning
Serial command : E8V (1s) Serial command : E8X (5s)
Serial command : E8W (3s)
• Read this quick start guide carefully before installing and/or using this product.
• Keep this quick start guide for future reference and store it in a safe place.
 
The time that a code will not be read after it is read successful
once can be set. This can prevent the double read of a code.
Multiple read reset time Setting
■Multiple read reset time
Serial command :
AJ (200ms)
Serial command : AK (300ms)
Serial command : E9I (800ms)
Serial command :
E9H (700ms)
Serial command :
AL (400ms)
Serial command :
AN(600ms)
Serial command :
E9J (900ms)
Serial command : AG (Infinity)
Serial command : AM (500ms)
Serial command :
E8T (1s)
All manuals and user guides at all-guides.com
all-guides.com
M-500009062-0-00
The Netherlands Opticon Sensors Europe B.V.
tel: +31 (0)23-5692700 / email: [email protected]
U.S.A. Opticon Inc.
tel: 800-636-0090 / email: [email protected]
France Opticon S.A.S.
tel: +33 (0)1-41461260 / email: [email protected]
Germany Opticon Sensoren GmbH
tel: +49 (0)6074-91890-0 / email: sales.de@opticon.com
Italy Opticon s.r.l.
tel: +39 (0)051-6321800 / email: opticon@opticonitalia.it
Spain Opticon Sensores S.L.
tel: +34 (0)902-747469 / email: [email protected]
Contact
Sweden Opticon Sensors Nordic AB
tel: +46 (0)8-58548560 / email: henrik@opticon-sensors.se
United Kingdom Opticon Limited
tel: +44 (0)1582-635100 / email: [email protected]
Taiwan Opticon Far Eastern Ltd.
tel: +886 2-27597444 / email: [email protected]
China
Opticon Sensors Europe B.V., Shanghai Representative Oce
tel: +86 21-64480881 / email: [email protected]
Australia Opticon Sensors Pty. Ltd.
tel: +61 (0)2-43402666 / email: [email protected]
Brazil Opticon Sensors Europe B.V., Latin American Oce
tel: +55 11-5081 2088 / email: [email protected]
Please contact OPTICON or your local dealer.
More product details, additional support, and configuration options (from the Universal Menu Book) are available at www.opticon.com.
Notice
• This quick start guide may be revised or withdrawn at any time without prior notice.
• This quick start guide may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any
electronic or machine readable form without prior written consent of Opticon.
• Trademarks used are property of their respective owners.
• Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or indirect
damages howsoever caused.
Precautions for Use
1. LED Safety
Do not stare into the LEDʼs.
2. Handling Instructions
【M-5】
• Do not attempt to disassemble, modify or update this device.
• Do not use the scanner while operating machinery.
• Do not drop or put heavy items on this product or its cable.
• Do not pinch or forcibly bend the cable, especially at very low temperature.
• Do not insert foreign substances into the device.
• Do not use/leave this device:
- In areas exposed to direct sunlight for long periods of time
- In dusty environments
- In risk for an exposure to chemicals
- Near water or other liquids, as well as in extremely high humidity
- Near heat sources such as radiators, heat registers, stoves, or other types of devices that produce heat
- Near microwaves, medical devices, or RF-emitting devices
- In the reach of blinking lights such as CRT
• Do not use this product during a lightning storm.
【AC/DC Adapter】
• Use only the supplied AC adapter with the enclosed region specific plugs for connection to the wall socket.
• This product may produce heat when in use, but it does not affect its performance.
• Do not pull on the cord when unplugging the power cord from a power outlet. Grasp the plug to remove it.
• Do not plug in or out this product with wet hands.
• Unplug this product when it is not in use or when it is being cleaned.
Quick Start Guide
Introduction
M-5
Copyright©2009, Opticon All rights reserved.
                      
Setting Menu Codes
The M-5 can be configured by reading the menu codes below. Read more about configuration options
(by Opticonfigure) on www.opticon.com.
■Detailed View
Overview
■M-5 Basic Specifications
Parameter Specifications
Physical
Features
Size (H)140.0 ×(W)92.0 ×(D)95.5 mm
Weight Approx.295g (excluding the cable)
Operation
Section
Scan Confirmation
Buzzer and 3 colors LED(Green/Blue/Orange)
Keys 2 keys (Trigger Switch/Mode Switch)
Interfaces
RS-232C 9600bps 〜115.2kbps
USB Full-Speed 12Mbps(HID/VCP)
Hi-Power Bus-powered
Wedge
PS/2 Keyboard (Connect or disconnect the keyboard.)
Control
Section
ASIC
OEY-0603 CPU:ARM-1026EJ-S Core:160MHz
SDRAM 128Mbits(1M ×4Banks ×32Bits)
Flash ROM 16Mbits(1M ×16Bits) Flash Memory
Scanning
Section
Light Source
Wavelength
8-AllnGaP Red LEDs(Omniscan Mode)/625nm
4-AllnGaP red LEDs (Mobile Mode)/633nm
Scanning Method
WVGA(752 x 480 pixels) CMOS area sensor
Supported
Symbologies
(1D)
UPC-A,UPC-E, UPC-E1, UPC-A Add-on, UPC-E Add-on, EAN-13,
EAN-8, EAN-13 Add-on/EAN-8 Add-on, JAN-8 , JAN-13, Code
39,Tri-Optic, NW-7, Industrial 2 of 5, Interleaved 2 of 5, Code 93,
Code 128, GS1-128, S-Code, MSI/Plessey, UK/Plessey, TELEPEN,
Matrix 2 of 5, Chinese Post Matrix 2 of 5, IATA,Code 11,
Korean Postal Authority code , GS1 DataBar, Postal Code
Supported
Symbologies
(2D)
PDF417,MicroPDF417, QR Code,MicroQR Code,Data
Matrix (ECC 000-140/ECC 200),MaxiCode (Modes 2 to 5),
Aztec Code, EAN.UCC Composite bar code, Codablock F
Power
Supply
Section
Operating voltage
4.5 to 6.6V
Current
consumption
USB
RS-232C,Wedge
Peak
(when scanning and decoding)
420mA 400mA
Average
(when scanning and decoding)
280mA(typ)
210mA (typ)
Stand-by
140mA(typ)
130mA(typ)
Durability
Operating Temp.
0 to 40 deg. C
Storage Temp.
−40 to 70 deg. C
Operating Humidity
5 to 95%(non-condensing)
Storage Humidity
5 to 95%(non-condensing)
Ambient
Light
Immunity
Fluorescent:10,000lx or less
Incandescent lamp:10,000lx or less
Sunlight
:
50,000lx or less (*1)
Dust-and-Drip Proof
IP52
Static Electricity
15kV (no destruction)
Shock
Endurance
Dropped once from each of 5 angles onto
concrete floor from a height of 150cm with
no defects found. (Total 5 times)
No. Part Function
①
Optical Window
−−−−−−−−−−−
②Trigger Switch
The trigger switch is used for the manual
scanning operation. A single aiming guide
will be activated in this mode.
③
Mode Switch
The mode switch toggles between Mobile phone
scanning mode and Normal scanning mode.
④Indicator LED
Green LED light shows the scanning
operation has been successful.
Blue LED light shows when the scanner is
ready to scan.
⑤
Indicator LED While Mobile
phone scanning Mode
Orange LED light shows when the scanner
is ready for mobile code scanning.
⑥Buzzer Holes
−−−−−−−−−−−
⑦Screw Holes
Used to mount the scanner onto a base plate,
wall etc. using D4 (diameter: 4mm) screws.
①
⑦
②
③
⑥
⑤④
Before Getting Started
No. Item Function Notes
1Scanner An omnidirectional imaging scanner
−−−−−−−−−−−
2Interface cable A cable for connecting the scanner Different for each interface spec.
3Wedge branch cable Y-cable: The cable that can be used to connect a keyboard
and the scanner's straight cable to a host computer. Only for Wedge interface.
4Connector cover A cover used to fix the connection between the
Y-cable and the straight cable. Only for M-5-WEDGE+PS package.
5
Instruction of connector cover
An instruction manual for the connector cover Only for M-5-WEDGE+PS package.
6AC adapter AC adapter with interchangeable plugs
Only for RS-232C and
Wedge
interface.
7Interchangeable plugs Plugs for different regions
Only for RS-232C and
Wedge
interface.
8Quick start guide This manual provides the basic product specification
and setup instructions.
−−−−−−−−−−−
■What's in the Box
Confirm that you have the following items before getting started. Please note that the contents may differ
depending on interface specifications. Please contact the nearest dealer if items are damaged or missing.
■Various Scanning Modes
The following modes are available for different uses:
□Normal scanning mode
A mode in which the scanner is configured optimally for general barcode
reading. The device automatically starts scanning when a label is
held in front of it. The trigger key activates the single line scanning.
□Mobile phone scanning mode
A special mode ―in which the lighting conditions are optimized for
reading barcodes,―displayed on mobile devices such as a phone.
The device automatically starts scanning when a label is held in front
of it. The trigger key activates the single line scanning.
□Single line scanning
While the trigger switch is pressed, the illumination LEDs turn on
and only one code can be read. The single line can read one target
code out of multiple printed codes in this mode.
                      
Setting Menu Codes
(*1)Except
“
Mobile phone scanning mode
”
in each condition. Please note that scanning while the
LCD screen is exposed to direct sunlight may have a negative effect on the reading performance.
Figure 1. Scanning mode diagram
Normal scanning
mode
Mobile phone
scanning mode
Mode Switch
Power
ON
Singleline
scanning
Trigger
Switch
Finished Scanning
or Time-Out
■
Basic Specifications for Universal AC adapter
Parameter Specifications
Physical
Features
Size
(H)75 x (W)47.5 x (D)28mm (excluding boss)
Cable Length 1.8m
Colour Black
Input
Power Voltage
AC 90V to 265V
Supply Current
500mA Max
Output
Power Voltage
5.7V to 6.3V
Maximum Current
2A Max
Environmental
Specification
Operating Temp.
0 to 40 deg. C
Operating Humidity
25 to 85% (non-condensing)
Storage Temp.
−20 to 60 deg. C
Storage Humidity
20 to 90% (non-condensing)
Trigger
Switch
Finished Scanning
or Time-Out
: Default
Default Setting
■Enable QR Code
(* Use this only when “Disable QR Code”is set in advance.)
Start / END: ZZ
Enable QR Code: BCD
Stop / END: ZZ
■Back to default
Serial command : U2, C01, SU, UB
"Normal scanning mode" or "Mobile phone scanning mode"
can be selected as primary mode when the scanner starts up.
Scanning Mode Setting
■Normal scanning mode
Serial command : E8Y
■Mobile phone scanning mode
Serial command : E8Z
Auto trigger ON / OFF can be set. When it is set to OFF, only
the trigger switch can be used to activate the scanner.
Auto Trigger Setting
■Auto Trigger OFF
■Auto Trigger ON
Serial command : +I
Serial command : +F
You can set the time that the scanner will try to read a code
after it is detected by the auto trigger. This can be set for
“
Nor-
mal scanning mode
”
and
“
Mobile phone scanning mode
”
.
For single line scanning, it can be set as the LED aiming time.
Read Time Setting
■Normal scanning mode
Serial command : Y0 (0.5s) Serial command : Y2 (2.0s)
Serial command : Y1 (1.0s) Serial command : Y3 (3.0s)
■Mobile phone scanning mode
Serial command : E91 (1s) Serial command : E93 (3s)
Serial command : E92 (2s) Serial command : E94 (4s)
■Single line scanning
Serial command : E8V (1s) Serial command : E8X (5s)
Serial command : E8W (3s)
• Read this quick start guide carefully before installing and/or using this product.
• Keep this quick start guide for future reference and store it in a safe place.
 
The time that a code will not be read after it is read successful
once can be set. This can prevent the double read of a code.
Multiple read reset time Setting
■Multiple read reset time
Serial command :
AJ (200ms)
Serial command : AK (300ms)
Serial command : E9I (800ms)
Serial command :
E9H (700ms)
Serial command :
AL (400ms)
Serial command :
AN(600ms)
Serial command :
E9J (900ms)
Serial command : AG (Infinity)
Serial command : AM (500ms)
Serial command :
E8T (1s)
All manuals and user guides at all-guides.com
M-500009062-0-00
The Netherlands Opticon Sensors Europe B.V.
tel: +31 (0)23-5692700 / email: [email protected]
U.S.A. Opticon Inc.
tel: 800-636-0090 / email: [email protected]
France Opticon S.A.S.
tel: +33 (0)1-41461260 / email: [email protected]
Germany Opticon Sensoren GmbH
tel: +49 (0)6074-91890-0 / email: sales.de@opticon.com
Italy Opticon s.r.l.
tel: +39 (0)051-6321800 / email: opticon@opticonitalia.it
Spain Opticon Sensores S.L.
tel: +34 (0)902-747469 / email: [email protected]
Contact
Sweden Opticon Sensors Nordic AB
tel: +46 (0)8-58548560 / email: henrik@opticon-sensors.se
United Kingdom Opticon Limited
tel: +44 (0)1582-635100 / email: [email protected]
Taiwan Opticon Far Eastern Ltd.
tel: +886 2-27597444 / email: [email protected]
China
Opticon Sensors Europe B.V., Shanghai Representative Oce
tel: +86 21-64480881 / email: [email protected]
Australia Opticon Sensors Pty. Ltd.
tel: +61 (0)2-43402666 / email: [email protected]
Brazil Opticon Sensors Europe B.V., Latin American Oce
tel: +55 11-5081 2088 / email: [email protected]
Please contact OPTICON or your local dealer.
More product details, additional support, and configuration options (from the Universal Menu Book) are available at www.opticon.com.
Notice
• This quick start guide may be revised or withdrawn at any time without prior notice.
• This quick start guide may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any
electronic or machine readable form without prior written consent of Opticon.
• Trademarks used are property of their respective owners.
• Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or indirect
damages howsoever caused.
Precautions for Use
1. LED Safety
Do not stare into the LEDʼs.
2. Handling Instructions
【M-5】
• Do not attempt to disassemble, modify or update this device.
• Do not use the scanner while operating machinery.
• Do not drop or put heavy items on this product or its cable.
• Do not pinch or forcibly bend the cable, especially at very low temperature.
• Do not insert foreign substances into the device.
• Do not use/leave this device:
- In areas exposed to direct sunlight for long periods of time
- In dusty environments
- In risk for an exposure to chemicals
- Near water or other liquids, as well as in extremely high humidity
- Near heat sources such as radiators, heat registers, stoves, or other types of devices that produce heat
- Near microwaves, medical devices, or RF-emitting devices
- In the reach of blinking lights such as CRT
• Do not use this product during a lightning storm.
【AC/DC Adapter】
• Use only the supplied AC adapter with the enclosed region specific plugs for connection to the wall socket.
• This product may produce heat when in use, but it does not affect its performance.
• Do not pull on the cord when unplugging the power cord from a power outlet. Grasp the plug to remove it.
• Do not plug in or out this product with wet hands.
• Unplug this product when it is not in use or when it is being cleaned.
Quick Start Guide
Introduction
M-5
Copyright©2009, Opticon All rights reserved.
                      
Setting Menu Codes
The M-5 can be configured by reading the menu codes below. Read more about configuration options
(by Opticonfigure) on www.opticon.com.
■Detailed View
Overview
■M-5 Basic Specifications
Parameter Specifications
Physical
Features
Size (H)140.0 ×(W)92.0 ×(D)95.5 mm
Weight Approx.295g (excluding the cable)
Operation
Section
Scan Confirmation
Buzzer and 3 colors LED(Green/Blue/Orange)
Keys 2 keys (Trigger Switch/Mode Switch)
Interfaces
RS-232C 9600bps 〜115.2kbps
USB Full-Speed 12Mbps(HID/VCP)
Hi-Power Bus-powered
Wedge
PS/2 Keyboard (Connect or disconnect the keyboard.)
Control
Section
ASIC
OEY-0603 CPU:ARM-1026EJ-S Core:160MHz
SDRAM 128Mbits(1M ×4Banks ×32Bits)
Flash ROM 16Mbits(1M ×16Bits) Flash Memory
Scanning
Section
Light Source
Wavelength
8-AllnGaP Red LEDs(Omniscan Mode)/625nm
4-AllnGaP red LEDs (Mobile Mode)/633nm
Scanning Method
WVGA(752 x 480 pixels) CMOS area sensor
Supported
Symbologies
(1D)
UPC-A,UPC-E, UPC-E1, UPC-A Add-on, UPC-E Add-on, EAN-13,
EAN-8, EAN-13 Add-on/EAN-8 Add-on, JAN-8 , JAN-13, Code
39,Tri-Optic, NW-7, Industrial 2 of 5, Interleaved 2 of 5, Code 93,
Code 128, GS1-128, S-Code, MSI/Plessey, UK/Plessey, TELEPEN,
Matrix 2 of 5, Chinese Post Matrix 2 of 5, IATA,Code 11,
Korean Postal Authority code , GS1 DataBar, Postal Code
Supported
Symbologies
(2D)
PDF417,MicroPDF417, QR Code,MicroQR Code,Data
Matrix (ECC 000-140/ECC 200),MaxiCode (Modes 2 to 5),
Aztec Code, EAN.UCC Composite bar code, Codablock F
Power
Supply
Section
Operating voltage
4.5 to 6.6V
Current
consumption
USB
RS-232C,Wedge
Peak
(when scanning and decoding)
420mA 400mA
Average
(when scanning and decoding)
280mA(typ)
210mA (typ)
Stand-by
140mA(typ)
130mA(typ)
Durability
Operating Temp.
0 to 40 deg. C
Storage Temp.
−40 to 70 deg. C
Operating Humidity
5 to 95%(non-condensing)
Storage Humidity
5 to 95%(non-condensing)
Ambient
Light
Immunity
Fluorescent:10,000lx or less
Incandescent lamp:10,000lx or less
Sunlight
:
50,000lx or less (*1)
Dust-and-Drip Proof
IP52
Static Electricity
15kV (no destruction)
Shock
Endurance
Dropped once from each of 5 angles onto
concrete floor from a height of 150cm with
no defects found. (Total 5 times)
No. Part Function
①
Optical Window
−−−−−−−−−−−
②Trigger Switch
The trigger switch is used for the manual
scanning operation. A single aiming guide
will be activated in this mode.
③
Mode Switch
The mode switch toggles between Mobile phone
scanning mode and Normal scanning mode.
④Indicator LED
Green LED light shows the scanning
operation has been successful.
Blue LED light shows when the scanner is
ready to scan.
⑤
Indicator LED While Mobile
phone scanning Mode
Orange LED light shows when the scanner
is ready for mobile code scanning.
⑥Buzzer Holes
−−−−−−−−−−−
⑦Screw Holes
Used to mount the scanner onto a base plate,
wall etc. using D4 (diameter: 4mm) screws.
①
⑦
②
③
⑥
⑤④
Before Getting Started
No. Item Function Notes
1Scanner An omnidirectional imaging scanner
−−−−−−−−−−−
2Interface cable A cable for connecting the scanner Different for each interface spec.
3Wedge branch cable Y-cable: The cable that can be used to connect a keyboard
and the scanner's straight cable to a host computer. Only for Wedge interface.
4Connector cover A cover used to fix the connection between the
Y-cable and the straight cable. Only for M-5-WEDGE+PS package.
5
Instruction of connector cover
An instruction manual for the connector cover Only for M-5-WEDGE+PS package.
6AC adapter AC adapter with interchangeable plugs
Only for RS-232C and
Wedge
interface.
7Interchangeable plugs Plugs for different regions
Only for RS-232C and
Wedge
interface.
8Quick start guide This manual provides the basic product specification
and setup instructions.
−−−−−−−−−−−
■What's in the Box
Confirm that you have the following items before getting started. Please note that the contents may differ
depending on interface specifications. Please contact the nearest dealer if items are damaged or missing.
■Various Scanning Modes
The following modes are available for different uses:
□Normal scanning mode
A mode in which the scanner is configured optimally for general barcode
reading. The device automatically starts scanning when a label is
held in front of it. The trigger key activates the single line scanning.
□Mobile phone scanning mode
A special mode ―in which the lighting conditions are optimized for
reading barcodes,―displayed on mobile devices such as a phone.
The device automatically starts scanning when a label is held in front
of it. The trigger key activates the single line scanning.
□Single line scanning
While the trigger switch is pressed, the illumination LEDs turn on
and only one code can be read. The single line can read one target
code out of multiple printed codes in this mode.
                      
Setting Menu Codes
(*1)Except
“
Mobile phone scanning mode
”
in each condition. Please note that scanning while the
LCD screen is exposed to direct sunlight may have a negative effect on the reading performance.
Figure 1. Scanning mode diagram
Normal scanning
mode
Mobile phone
scanning mode
Mode Switch
Power
ON
Singleline
scanning
Trigger
Switch
Finished Scanning
or Time-Out
■
Basic Specifications for Universal AC adapter
Parameter Specifications
Physical
Features
Size
(H)75 x (W)47.5 x (D)28mm (excluding boss)
Cable Length 1.8m
Colour Black
Input
Power Voltage
AC 90V to 265V
Supply Current
500mA Max
Output
Power Voltage
5.7V to 6.3V
Maximum Current
2A Max
Environmental
Specification
Operating Temp.
0 to 40 deg. C
Operating Humidity
25 to 85% (non-condensing)
Storage Temp.
−20 to 60 deg. C
Storage Humidity
20 to 90% (non-condensing)
Trigger
Switch
Finished Scanning
or Time-Out
: Default
Default Setting
■Enable QR Code
(* Use this only when “Disable QR Code”is set in advance.)
Start / END: ZZ
Enable QR Code: BCD
Stop / END: ZZ
■Back to default
Serial command : U2, C01, SU, UB
"Normal scanning mode" or "Mobile phone scanning mode"
can be selected as primary mode when the scanner starts up.
Scanning Mode Setting
■Normal scanning mode
Serial command : E8Y
■Mobile phone scanning mode
Serial command : E8Z
Auto trigger ON / OFF can be set. When it is set to OFF, only
the trigger switch can be used to activate the scanner.
Auto Trigger Setting
■Auto Trigger OFF
■Auto Trigger ON
Serial command : +I
Serial command : +F
You can set the time that the scanner will try to read a code
after it is detected by the auto trigger. This can be set for
“
Nor-
mal scanning mode
”
and
“
Mobile phone scanning mode
”
.
For single line scanning, it can be set as the LED aiming time.
Read Time Setting
■Normal scanning mode
Serial command : Y0 (0.5s) Serial command : Y2 (2.0s)
Serial command : Y1 (1.0s) Serial command : Y3 (3.0s)
■Mobile phone scanning mode
Serial command : E91 (1s) Serial command : E93 (3s)
Serial command : E92 (2s) Serial command : E94 (4s)
■Single line scanning
Serial command : E8V (1s) Serial command : E8X (5s)
Serial command : E8W (3s)
• Read this quick start guide carefully before installing and/or using this product.
• Keep this quick start guide for future reference and store it in a safe place.
 
The time that a code will not be read after it is read successful
once can be set. This can prevent the double read of a code.
Multiple read reset time Setting
■Multiple read reset time
Serial command :
AJ (200ms)
Serial command : AK (300ms)
Serial command : E9I (800ms)
Serial command :
E9H (700ms)
Serial command :
AL (400ms)
Serial command :
AN(600ms)
Serial command :
E9J (900ms)
Serial command : AG (Infinity)
Serial command : AM (500ms)
Serial command :
E8T (1s)
All manuals and user guides at all-guides.com
M-500009062-0-00
The Netherlands Opticon Sensors Europe B.V.
tel: +31 (0)23-5692700 / email: [email protected]
U.S.A. Opticon Inc.
tel: 800-636-0090 / email: [email protected]
France Opticon S.A.S.
tel: +33 (0)1-41461260 / email: [email protected]
Germany Opticon Sensoren GmbH
tel: +49 (0)6074-91890-0 / email: sales.de@opticon.com
Italy Opticon s.r.l.
tel: +39 (0)051-6321800 / email: opticon@opticonitalia.it
Spain Opticon Sensores S.L.
tel: +34 (0)902-747469 / email: [email protected]
Contact
Sweden Opticon Sensors Nordic AB
tel: +46 (0)8-58548560 / email: henrik@opticon-sensors.se
United Kingdom Opticon Limited
tel: +44 (0)1582-635100 / email: [email protected]
Taiwan Opticon Far Eastern Ltd.
tel: +886 2-27597444 / email: [email protected]
China
Opticon Sensors Europe B.V., Shanghai Representative Oce
tel: +86 21-64480881 / email: [email protected]
Australia Opticon Sensors Pty. Ltd.
tel: +61 (0)2-43402666 / email: [email protected]
Brazil Opticon Sensors Europe B.V., Latin American Oce
tel: +55 11-5081 2088 / email: [email protected]
Please contact OPTICON or your local dealer.
More product details, additional support, and configuration options (from the Universal Menu Book) are available at www.opticon.com.
Notice
• This quick start guide may be revised or withdrawn at any time without prior notice.
• This quick start guide may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any
electronic or machine readable form without prior written consent of Opticon.
• Trademarks used are property of their respective owners.
• Under no circumstances shall Opticon be held responsible for any special, incidental, consequential or indirect
damages howsoever caused.
Precautions for Use
1. LED Safety
Do not stare into the LEDʼs.
2. Handling Instructions
【M-5】
• Do not attempt to disassemble, modify or update this device.
• Do not use the scanner while operating machinery.
• Do not drop or put heavy items on this product or its cable.
• Do not pinch or forcibly bend the cable, especially at very low temperature.
• Do not insert foreign substances into the device.
• Do not use/leave this device:
- In areas exposed to direct sunlight for long periods of time
- In dusty environments
- In risk for an exposure to chemicals
- Near water or other liquids, as well as in extremely high humidity
- Near heat sources such as radiators, heat registers, stoves, or other types of devices that produce heat
- Near microwaves, medical devices, or RF-emitting devices
- In the reach of blinking lights such as CRT
• Do not use this product during a lightning storm.
【AC/DC Adapter】
• Use only the supplied AC adapter with the enclosed region specific plugs for connection to the wall socket.
• This product may produce heat when in use, but it does not affect its performance.
• Do not pull on the cord when unplugging the power cord from a power outlet. Grasp the plug to remove it.
• Do not plug in or out this product with wet hands.
• Unplug this product when it is not in use or when it is being cleaned.
Quick Start Guide
Introduction
M-5
Copyright©2009, Opticon All rights reserved.
                      
Setting Menu Codes
The M-5 can be configured by reading the menu codes below. Read more about configuration options
(by Opticonfigure) on www.opticon.com.
■Detailed View
Overview
■M-5 Basic Specifications
Parameter Specifications
Physical
Features
Size (H)140.0 ×(W)92.0 ×(D)95.5 mm
Weight Approx.295g (excluding the cable)
Operation
Section
Scan Confirmation
Buzzer and 3 colors LED(Green/Blue/Orange)
Keys 2 keys (Trigger Switch/Mode Switch)
Interfaces
RS-232C 9600bps 〜115.2kbps
USB Full-Speed 12Mbps(HID/VCP)
Hi-Power Bus-powered
Wedge
PS/2 Keyboard (Connect or disconnect the keyboard.)
Control
Section
ASIC
OEY-0603 CPU:ARM-1026EJ-S Core:160MHz
SDRAM 128Mbits(1M ×4Banks ×32Bits)
Flash ROM 16Mbits(1M ×16Bits) Flash Memory
Scanning
Section
Light Source
Wavelength
8-AllnGaP Red LEDs(Omniscan Mode)/625nm
4-AllnGaP red LEDs (Mobile Mode)/633nm
Scanning Method
WVGA(752 x 480 pixels) CMOS area sensor
Supported
Symbologies
(1D)
UPC-A,UPC-E, UPC-E1, UPC-A Add-on, UPC-E Add-on, EAN-13,
EAN-8, EAN-13 Add-on/EAN-8 Add-on, JAN-8 , JAN-13, Code
39,Tri-Optic, NW-7, Industrial 2 of 5, Interleaved 2 of 5, Code 93,
Code 128, GS1-128, S-Code, MSI/Plessey, UK/Plessey, TELEPEN,
Matrix 2 of 5, Chinese Post Matrix 2 of 5, IATA,Code 11,
Korean Postal Authority code , GS1 DataBar, Postal Code
Supported
Symbologies
(2D)
PDF417,MicroPDF417, QR Code,MicroQR Code,Data
Matrix (ECC 000-140/ECC 200),MaxiCode (Modes 2 to 5),
Aztec Code, EAN.UCC Composite bar code, Codablock F
Power
Supply
Section
Operating voltage
4.5 to 6.6V
Current
consumption
USB
RS-232C,Wedge
Peak
(when scanning and decoding)
420mA 400mA
Average
(when scanning and decoding)
280mA(typ)
210mA (typ)
Stand-by
140mA(typ)
130mA(typ)
Durability
Operating Temp.
0 to 40 deg. C
Storage Temp.
−40 to 70 deg. C
Operating Humidity
5 to 95%(non-condensing)
Storage Humidity
5 to 95%(non-condensing)
Ambient
Light
Immunity
Fluorescent:10,000lx or less
Incandescent lamp:10,000lx or less
Sunlight
:
50,000lx or less (*1)
Dust-and-Drip Proof
IP52
Static Electricity
15kV (no destruction)
Shock
Endurance
Dropped once from each of 5 angles onto
concrete floor from a height of 150cm with
no defects found. (Total 5 times)
No. Part Function
①
Optical Window
−−−−−−−−−−−
②Trigger Switch
The trigger switch is used for the manual
scanning operation. A single aiming guide
will be activated in this mode.
③
Mode Switch
The mode switch toggles between Mobile phone
scanning mode and Normal scanning mode.
④Indicator LED
Green LED light shows the scanning
operation has been successful.
Blue LED light shows when the scanner is
ready to scan.
⑤
Indicator LED While Mobile
phone scanning Mode
Orange LED light shows when the scanner
is ready for mobile code scanning.
⑥Buzzer Holes
−−−−−−−−−−−
⑦Screw Holes
Used to mount the scanner onto a base plate,
wall etc. using D4 (diameter: 4mm) screws.
①
⑦
②
③
⑥
⑤④
Before Getting Started
No. Item Function Notes
1Scanner An omnidirectional imaging scanner
−−−−−−−−−−−
2Interface cable A cable for connecting the scanner Different for each interface spec.
3Wedge branch cable Y-cable: The cable that can be used to connect a keyboard
and the scanner's straight cable to a host computer. Only for Wedge interface.
4Connector cover A cover used to fix the connection between the
Y-cable and the straight cable. Only for M-5-WEDGE+PS package.
5
Instruction of connector cover
An instruction manual for the connector cover Only for M-5-WEDGE+PS package.
6AC adapter AC adapter with interchangeable plugs
Only for RS-232C and
Wedge
interface.
7Interchangeable plugs Plugs for different regions
Only for RS-232C and
Wedge
interface.
8Quick start guide This manual provides the basic product specification
and setup instructions.
−−−−−−−−−−−
■What's in the Box
Confirm that you have the following items before getting started. Please note that the contents may differ
depending on interface specifications. Please contact the nearest dealer if items are damaged or missing.
■Various Scanning Modes
The following modes are available for different uses:
□Normal scanning mode
A mode in which the scanner is configured optimally for general barcode
reading. The device automatically starts scanning when a label is
held in front of it. The trigger key activates the single line scanning.
□Mobile phone scanning mode
A special mode ―in which the lighting conditions are optimized for
reading barcodes,―displayed on mobile devices such as a phone.
The device automatically starts scanning when a label is held in front
of it. The trigger key activates the single line scanning.
□Single line scanning
While the trigger switch is pressed, the illumination LEDs turn on
and only one code can be read. The single line can read one target
code out of multiple printed codes in this mode.
                      
Setting Menu Codes
(*1)Except
“
Mobile phone scanning mode
”
in each condition. Please note that scanning while the
LCD screen is exposed to direct sunlight may have a negative effect on the reading performance.
Figure 1. Scanning mode diagram
Normal scanning
mode
Mobile phone
scanning mode
Mode Switch
Power
ON
Singleline
scanning
Trigger
Switch
Finished Scanning
or Time-Out
■
Basic Specifications for Universal AC adapter
Parameter Specifications
Physical
Features
Size
(H)75 x (W)47.5 x (D)28mm (excluding boss)
Cable Length 1.8m
Colour Black
Input
Power Voltage
AC 90V to 265V
Supply Current
500mA Max
Output
Power Voltage
5.7V to 6.3V
Maximum Current
2A Max
Environmental
Specification
Operating Temp.
0 to 40 deg. C
Operating Humidity
25 to 85% (non-condensing)
Storage Temp.
−20 to 60 deg. C
Storage Humidity
20 to 90% (non-condensing)
Trigger
Switch
Finished Scanning
or Time-Out
: Default
Default Setting
■Enable QR Code
(* Use this only when “Disable QR Code”is set in advance.)
Start / END: ZZ
Enable QR Code: BCD
Stop / END: ZZ
■Back to default
Serial command : U2, C01, SU, UB
"Normal scanning mode" or "Mobile phone scanning mode"
can be selected as primary mode when the scanner starts up.
Scanning Mode Setting
■Normal scanning mode
Serial command : E8Y
■Mobile phone scanning mode
Serial command : E8Z
Auto trigger ON / OFF can be set. When it is set to OFF, only
the trigger switch can be used to activate the scanner.
Auto Trigger Setting
■Auto Trigger OFF
■Auto Trigger ON
Serial command : +I
Serial command : +F
You can set the time that the scanner will try to read a code
after it is detected by the auto trigger. This can be set for
“
Nor-
mal scanning mode
”
and
“
Mobile phone scanning mode
”
.
For single line scanning, it can be set as the LED aiming time.
Read Time Setting
■Normal scanning mode
Serial command : Y0 (0.5s) Serial command : Y2 (2.0s)
Serial command : Y1 (1.0s) Serial command : Y3 (3.0s)
■Mobile phone scanning mode
Serial command : E91 (1s) Serial command : E93 (3s)
Serial command : E92 (2s) Serial command : E94 (4s)
■Single line scanning
Serial command : E8V (1s) Serial command : E8X (5s)
Serial command : E8W (3s)
• Read this quick start guide carefully before installing and/or using this product.
• Keep this quick start guide for future reference and store it in a safe place.
 
The time that a code will not be read after it is read successful
once can be set. This can prevent the double read of a code.
Multiple read reset time Setting
■Multiple read reset time
Serial command :
AJ (200ms)
Serial command : AK (300ms)
Serial command : E9I (800ms)
Serial command :
E9H (700ms)
Serial command :
AL (400ms)
Serial command :
AN(600ms)
Serial command :
E9J (900ms)
Serial command : AG (Infinity)
Serial command : AM (500ms)
Serial command :
E8T (1s)
All manuals and user guides at all-guides.com