OPW Matador User manual

Matador Manhole
Installation Instructions
Please read these warnings and assembly instructions
completely and carefully before starting. Failure to do
so may cause product failure, or result in environmental
contamination due to liquid leakage into the soil, creat-
ing hazardous spill conditions.
WARNING-DANGER: Using electrically operated equip-
ment near gasoline or gasoline vapors may result in a
re or explosion, causing personal injury and property
damage. Be sure that the working area is free from such
hazards, and always use proper precautions.
Notice: OPW products must be used in compliance with
applicable federal, state, and local laws and regulations.
Product selection should be based on physical speci-
cations and limitations and compatibility with the envi-
ronment and material to be handled. All illustrations
and specications in this literature are based on the lat-
est production information available at the time of pub-
lication. Prices, materials, and specication are subject
to change at any time, and models may be discontinued
at any time, in either case, without notice or obligation.
MATADOR MANHOLE INSTALLATION
INSTRUCTIONS:
Step 1: Mark o nish grade, (See Figure 1).
Figure 1
Step 2: Set Matador manhole assembly (skirt, ring, and
cover) to the nal grade position, (See Figure 2). Please
note that during the backll process care must be taken
to nest the skirt into the backll material for proper skirt
support. Also take care to not misshape the skirt due to
over tamping of the backll material. If the skirt is forced
into an improper condition it must be repositioned and
properly supported to ensure the below dened clear-
ances are maintained during and after concrete installa-
tion.
Figure 2
Step 3: It is strongly recommended that cover be in-
stalled with the following minimum clearances, (See
Figure 3). Skirts should have adequate clearance be-
tween the tank sump riser sidewall and or the sump top
hat. A minimum of two inches clearance on all sides is
recommended between the skirt and the tank sump
wall or the sump top hat wall. A minimum of two inches
clearance is recommended between the bottom of the
skirt and the horizontal surface of the tank sump or
sump top hat. These clearances are recommended to
allow adequate water migration away from the sumps.
Great care should be used to maintain the recommend-
ed clearances when setting the rings and pouring the
concrete as mentioned above.
Figure 3

OPW Standard Product Warranties
NOTICE: FlexWorks by OPW, Inc., VAPORSAVER™ and all other OPW products must be used in compliance with all applicable federal, state, pro-
vincial and local laws, rules and regulations. Product selection is the sole responsibility of the customer and/or its agents and must be based on
physical specications and limitations, compatibility with the environment and material to be handled. All illustrations and specications in
this literature are based on the latest production information available at the time of publication. Prices, materials and specications are sub-
ject to change at any time, and models may
be discontinued at any time, in either case, without notice or obligation.
OPW warrants solely to its customer (the initial purchaser and any subsequent purchasers within the warranty period) that the following prod-
ucts sold by OPW will be free from defects in materials and workmanship under normal use and conditions for the periods indicated:
OPW’s exclusive obligation under this limited warranty is, at its option, to repair, replace or issue credit (in an amount not to exceed the list
price for the product) for future orders for any product that may prove defective within the applicable warranty period (repairs or replace-
ments are subject to prorated warranty coverage for remainder of the original warranty period). Complete and proper warranty claim docu-
mentation and proof of purchase required. All warranty claims must be made in writing and delivered during the applicable warranty period
to OPW at OPW 9393 Princeton-Glendale Road Hamilton, Ohio, USA 45011, Attention: Customer Service Manager. No products may be re-
turned to OPW without its prior written authority.
This limited warranty shall not apply to any FlexWorks or VAPORSAVER™ product unless it is installed by an OPW attested installer. This limited
warranty also shall not apply to any FlexWorks, VAPORSAVER™ or other OPW product: unless all required site and warranty registration forms
are completed and received by OPW within 60 days of installation; unless all piping connections are installed with a nationally-recognized or
state-approved leak detection device in each tank and dispenser sump (which are not for storage and from which all discharge hydrocarbons
must be removed, and the systems completely cleaned, within 24 hours); unless testable sumps utilize FlexWorks pipe and access ttings; un-
less a sump inspection log or an EPA recommended/required checklist is maintained and the results are furnished to OPW upon request; and
unless OPW is notied within 24 hours of any known or suspected product failure and is provided with unrestricted access to the product and
the site. This limited warranty also shall not apply to any product which has been altered in any way, which has been repaired by anyone other
than a service representative authorized by OPW, or when failure or defect is due to: improper installation or maintenance (including, without
limitation, failure to follow FlexWorks Quick Reference Manual Installation Guide and all product warning labels); abuse or misuse; violation of
health or safety requirements; use of another manufacturer’s, or otherwise unauthorized, substances or components; soil or other surface or
subsurface conditions; or re, ood, storm, lightning, earthquake, accident or any other conditions, events or circumstances beyond OPW’s
control.
THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND ALL OTHER WARRANTIES INCLUDING, WITHOUT
LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY EXCLUDED.
OPW shall have no other liability whatsoever, whether based on breach of contract, negligence, gross negligence, strict liability or any other
claim, including, without limitation, for special, incidental, consequential or exemplary damages or for the cost of labor, freight, excavation,
clean-up, downtime, removal, reinstallation, loss of prot, or any other cost or charges. No person or entity is authorized to assume on behalf of
OPW any liability beyond this limited warranty. This limited warranty is not assignable.
Part Number: 214870 Rev A
Issue Date: 02-13-2019
OPW Retail Fueling
3250 US 70 Business West
Smitheld, NC 27577
Customer Service:1-(800) 422-2525
Technical Service and Questions:
1-(877) OPW-TECH
PRODUCT WARRANTY PERIOD
FlexWorks Primary Pipe 10 years from date of manufacture
ll Products and replacement parts installed in the State of California
Certied to California CP-201 and/or CP-206 Standards*
1 year from date of installation (proof of purchase from
certied contractors/technicians required). OPW warrants ongoing
compliance with the standards and specications for the duration of
the warranty period required by the State of California; this limited
warranty is under the condition the equipment was installed and
maintained by trained and certied contractors/technicians unless
noted in Installation Manual.
All Other Products 1 year from date of manufacture
*Products certied to California CP-201 and/or CP-206 Standards have been factory tested and met all applicable performance standards and
specications and will have an OPW registration card enclosed/attached to the product .