manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. OR STEEL light
  6. •
  7. Lighting Equipment
  8. •
  9. OR STEEL light FICHE TECHNIQUE LINE User manual

OR STEEL light FICHE TECHNIQUE LINE User manual

FICHE TECHNIQUE
LED rail light for driveways, stairs, movement areas. It consists of a length of structure
with an integrated connection lead to connect to other rail spotlights or directly to the
power source. Dierent sizes can be produced on request to create a continuous line.
One single 120° angle is available with watertight IP69 opal or clear diusion. It is cast
in one piece, so it is the ideal oodlight for all your contemporary
architectural lighting projects.
LINE
RGBW DYNAMIC WHITE 24VDC
POWER 19W/mètre
SUPPLY 24VDC
POWER
SUPPLY
Not included
WIRING Parallel
Electrical features
TECHNICAL SHEMATICS
SIZE (1/2/3/4/5m)x15x15mm
WEIGHT 0.6kg for 1m
MATERIAL Aluminium anodised
OPERATING
TEMPERATURE
- 20°c ~+ 60°
PROTECTION RAITING IP69
RESISTANCE INDEX IK10
APPLICANCE CLASS CLASS III
WALKOVER FIXTURE YES
DRIVE-OVER FIXTURE YES
Mechanical characteristics
INSTALLATION SHEMATICS
General characreristics
POWER SUPPLY
CABLES
Supply wire 5x0.22
mm2 in IP68
PHOTOBIOLOGICAL
SAFETY
Risk group I
ENERGY CLASS A /A+ /A++
All data are given for information purposes only. They do not constitute a contractual commitment on our part and are subject
to change at any time.
LL
1515
1515
T° max 55°C
AA+
A++
IK10
IP69
0,6
1 mètre
AVERAGE LIFE OF THE
LED
60 000 hours
Certicated L90 B10
COLOUR EMISSION RGBW :
Red - Green - Blue -
4000°K
Dynamic white :
2700°K - 3000°K
4000°K - 6000°K
BEAM 115°
INITIAL OUTFLOW 358lm at 4000k
Characteristics
lighting techniques
IP68
Connecteur
Parallel wiring RGBW
12
USE A IP68 CONNECTOR
Not submerged
Press the projector
into the sheath
Sealed sleeve
Seal the sealing
sheath
1. Use
Linear projector fixed to lateral brackets or swivel mount bracket. For interior
and exterior architectural lighting, used for illuminating large flat surfaces or
to provide long linear lighting zones. Its small dimension cables mean it can be
discreetly placed at the foot of walls or in ledges. Only an IP69 connection to the
electricity network ensures the IP69 degree of the product
2. Technical data/Assembly
Projector with 19W/m LED RGBW/W. Delivered with 1 m of 5x0,22mmsubmersible
cable.
3. Installation/assembly
Please comply with the applicable national safety requirements We disclaim
all responsibility for non-compliant use or assembly Similarly, we reject any
responsibility for any modifications you may make to the light fittings.
24VDC projectors must always be connected in parallel to the corresponding DC
power supply. Do not disassemble the projector casing, because the cables and
the plate are sealed. The spotlight can be installed in concrete, paving blocks,
plates, wood. We cannot supply universal installation instructions because ground
conditions and the location will vary for each project. The pictograms show
examples of typical installations.
When mounting on a reinforced bracket, you must remove the screws; remove the
projector from its support and direct it toward the object to be lit. Then fix to the
bracket using the A4 stainless steel screws provided.
Use only the factory-connected cables. Please indicate the required cable length
when ordering. In the event of mechanical stress, the cable must be installed in a
protective conduit. The silicone cable must only be connected to the power supply
in a dry environment and, in the event of a direct connection in the ground,
only connection units compatible with a joint sealing compound should be used.
Connect the various conductors to power supplies in accordance with instructions.
4. Connection to power supply
24VDC spotlights must only be connected in parallel.
5. General Maintenance Instructions
Do not use detergents which are harmful to metals when cleaning the spotlight.
The use of hydrochloric acid-based detergents on and around any parts of a
stainless steel light fitting is totally forbidden.
Regularly clean the spotlight and its mounting box to avoid any rust deposit
Caution: Do not use a high pressure cleaner. Caution: Protect the spotlights from
frost; where appropriate, dismantle or ensure special protection. Any lost screws
must be replaced by stainless steel V4A screws. According to conditions of use
(power, environmental circumstances), it is recommended to change the seals
(on the glass, screw fittings and O-rings) and the cable every 5 to 8 years.
6. Warranty conditions
The following time limits and provisions of the warranty shall apply from
the date of delivery: - 24 months for Orsteel spotlights. The warranty covers
defects in materials, manufacturing defects and any treatment which is proven
to be attributable to the manufacturer. Any damage resulting from the non-
compliance with this user leaflet or any non-compliant repair is excluded from the
warranty. We disclaim any guarantee where the installation has not been carried
out according to the instructions or where unsuitable bulbs or connection cables
have been used. We reserve the right to make any modification corresponding to
technical advancement.
7. Important Notice
(The warranty becomes void in the event of non-compliance with the following
points)
The absence of damage during transport must be verified before installation.
Any assembling and installation, as well as any electrical work, must be carried
out by qualified personnel.
To avoid any rust deposits, only stainless steel tools should be used.
The cable length for lamps must be chosen to avoid extending it in water or in a
damp environment. Any subsequent claim for this reason will not be accepted.
A mounting distance of 10 cm between each device is strongly recommended to
avoid mutual heating.
Equipment must be connected without current, otherwise surges in the power
supply could damage the LEDS. There must be no primary voltage when changing
LEDs.
When connecting the lamps, please ensure that polarity matches! A polarity error
may damage the LED module.
The customer is advised to install protection against any over voltage compliant
with standards DIN VDE 0100-443, DIN VDE 0100-534 and En 62305.
INSTALLATION GUIDE

Popular Lighting Equipment manuals by other brands

Clevetronics L10 LUBPRO Series Installation & maintenance instructions

Clevetronics

Clevetronics L10 LUBPRO Series Installation & maintenance instructions

thomann Ignition LED Mini Studio PAR One 40 user manual

thomann

thomann Ignition LED Mini Studio PAR One 40 user manual

Somogyi Elektronic home FLP5SOLAR instruction manual

Somogyi Elektronic

Somogyi Elektronic home FLP5SOLAR instruction manual

IKEA JORMLIEN manual

IKEA

IKEA JORMLIEN manual

ProLights BB5PIX user manual

ProLights

ProLights BB5PIX user manual

Briteq LDP COBWASH Operation manual

Briteq

Briteq LDP COBWASH Operation manual

ARELUX XGO GO10M E instructions

ARELUX

ARELUX XGO GO10M E instructions

Eterna ELEGAN5EM3 installation instructions

Eterna

Eterna ELEGAN5EM3 installation instructions

Narex CR LED 20 Original operating manual

Narex

Narex CR LED 20 Original operating manual

Eaton CEAG CGLine Series Mounting and operating instructions

Eaton

Eaton CEAG CGLine Series Mounting and operating instructions

Retlux RNL 106 operating manual

Retlux

Retlux RNL 106 operating manual

Quoizel RGN8607WS installation guide

Quoizel

Quoizel RGN8607WS installation guide

EuroLite 9460120N user manual

EuroLite

EuroLite 9460120N user manual

LDR Suono f650 plus white operating instructions

LDR

LDR Suono f650 plus white operating instructions

Inspire Minta instruction manual

Inspire

Inspire Minta instruction manual

SGM G-4 RGBAM WASH user manual

SGM

SGM G-4 RGBAM WASH user manual

TFA 98.1121 instruction manual

TFA

TFA 98.1121 instruction manual

SIGNIFY LIGHTOLIER IS-MD1R Instructions for installation and operation

SIGNIFY

SIGNIFY LIGHTOLIER IS-MD1R Instructions for installation and operation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.