TECHNICAL MANUAL
The Polynesia submersible floodlight is very powerful. It provides strong controlLED
lighting to enhance your aquatic areas such as ponds, lakes or waterfalls. You
can also use it in a marine environment. Its high luminous flux gives excellent
underwater light diffusion. Its advantage: the Polynesia is assembLED with
powerLEDs to provide a daylight effect at night.
POLYNESIA
350mA-700mA - 1200mA
POWER 60x3.5W
SUPPLY
350mA-700mA -
1200mA
POWER
SUPPLY
Not included
WIRING Serial
Electrical features
TECHNICAL SHEMATICS
DIMENSIONS Ø 230mm
WEIGHT 17kg
MATERIAL 316L Stainless steel
electropolished
OPERATING
TEMPERATURE
- 20°c ~+ 60°
PROTECTION RAITING IP69
RESISTANCE INDEX IK10
APPLICANCE CLASS CLASS III
WALKOVER FIXTURE NO
DRIVE-OVER FIXTURE NO
Mechanical features
INSTALLATION SHEMATICS
General features
POWER SUPPLY
CABLES
Supply wire 2x1mm2
in IP68
PHOTOBIOLOGICAL
SAFETY
Risk group I
ENERGY CLASS A /A+/A++
All data are given for information purposes only. They do not constitute a contractual commitment on our part and are subject
to change at any time.
T° max 55°C
AA+
A++
ACS
IK10
IP69
17
232300
7373
141400
AVERAGE LIFE OF THE
LED
60 000 hours
Certicated L90 B10
COLOUR EMISSION 2700K - 3000K -
4000K - 6000K
RED - GREEN
BLUE - AMBER
BEAM 10°-25°-40-115°
INITIAL OUTFLOW 19244lm at 3000k
Features
lighting technology
Serial wiring 350-700mA - 1200mA
Water level
Concrete
1. Use
Submersible recessed spotlight for occasional use and lighting small underwater
areas. Illuminates steps, small pools, waterfalls or a marine environment. Only
an IP69 connection to the electricity network ensures the IP69 degree of the
product.
Spotlight for permanent submersion only. Construction/special Functions
available on request. Please note that during installation in water, the intensity
depends on the turbidity of the water.
2. Technical data/Assembly
Spotlight in 316L INOX electro-polished - 60x 2,5W LED - Color emission : cold
white (6000 K), neutral white (4500 K), warm white (3000 K), red, green, blue
and amber. 316L stainless steel gland. Delivered with 2x0.55 mm² Submersible
cable·
3. Installation/Assembly
Please comply with the applicable national safety requirements. We disclaim
all responsibility for non-compliant use or assembly. Similarly, we reject any
responsibility for any modifications you may make to the light fittings.
For their use, constant current spotlights must always be connected in series to
the corresponding DC power supply (see power packs) (350-700mA - 1200mA).
Exterior installation can be carried out on different media. The spotlight can
be installed directly in concrete, paving blocks, plates, wood and using a Pt800
earth rod. We cannot supply universal installation instructions because ground
conditions and the location will vary for each project.
The pictograms show examples of typical installations.
When mounting on a reinforced bracket, you must remove the screws.
Remove the projector from its support and direct it toward the object to be lit.
Then fix to the bracket using the A4 stainless steel screws provided. Use only
the factory-connected cables. Please indicate the required cable length when
ordering. In the event of mechanical stress, the cable must be installed in a
protective conduit.
The silicone cable must only be connected to the power supply in a dry environment
and, in the event of a direct connection in the ground, only connection units
compatible with a joint sealing compound should be used.
Connect the various conductors to power supplies in accordance with instructions.
4. Connecting to the power packs/connection matrix
Constant current spotlights must only be connected in series. H/I. If applicable,
proceed with connection in series in separate load distribution units, the outside
of which must also be protected against humidity using a sealing compound.
5. General Maintenance Instructions
Do not use detergents which are harmful to metals when cleaning the spotlight.
The use of hydrochloric acid-based detergents on and around any parts of a
stainless steel light fitting is totally forbidden.
Regularly clean the spotlight and its mounting box to avoid any rust deposit.
Caution: Do not use a high pressure cleaner. Any lost screws should only be
replaced by V4A stainless steel screws.
According to conditions of use (power, environmental circumstances), it is
recommended to change the seals (on the glass, screw fittings and O-rings) and
the cable every 5 to 8 years.
6. Warranty conditions
The following time limits and provisions of the warranty shall apply from the date
of delivery: - 24 months for Orsteel spotlights
The warranty covers defects in materials, manufacturing defects and any
treatment which is proven to be attributable to the manufacturer.
Any damage resulting from the non-compliance with this user leaflet or any non-
compliant repair is excluded from the warranty.
We disclaim any guarantee where the installation has not been carried out
according to the instructions or where unsuitable bulbs or connection cables have
been used.
We reserve the right to make any modification corresponding to technical
advancement.
7. Important Notice
(The warranty becomes void in the event of non-compliance with the following
points)
The absence of damage during transport must be verified before installation.
Any assembling and installation, as well as any electrical work, must be carried
out by qualified personnel.
To avoid any rust deposits, only stainless steel tools should be used.
The cable length for lamps must be chosen to avoid extending it in water or in a
damp environment. Any subsequent claim for this reason will not be accepted.
A mounting distance of 10 cm between each device is strongly recommended to
avoid mutual heating.
Equipment must be connected without current, otherwise surges in the power
supply could damage the LEDS. There must be no primary voltage when changing
LEDs.
When connecting the lamps, please ensure that polarity matches! A polarity error
may damage the LED module.
The customer is advised to install protection against any over voltage compliant
with standards DIN VDE 0100-443, DIN VDE 0100-534 and En 62305.
Please observe the measures against electrostatic discharge during all work on
the spotlights, equipment and LEDs.
INSTALLATION MANUAL

Other OR STEEL light Underwater Lighting manuals

OR STEEL light TALOS User manual

OR STEEL light

OR STEEL light TALOS User manual

OR STEEL light SILURE RGBW User manual

OR STEEL light

OR STEEL light SILURE RGBW User manual

Popular Underwater Lighting manuals by other brands

GAME Underwater Light Startship instructions

GAME

GAME Underwater Light Startship instructions

Hayward 7016849 user guide

Hayward

Hayward 7016849 user guide

EasyPro LED6WP Instructions for Operation, Safety, Warranty

EasyPro

EasyPro LED6WP Instructions for Operation, Safety, Warranty

LIGMAN JANET 1 JA-60067 installation manual

LIGMAN

LIGMAN JANET 1 JA-60067 installation manual

EasyPro LED9WWK Instructions for operation

EasyPro

EasyPro LED9WWK Instructions for operation

ccei GAMK Technical manual

ccei

ccei GAMK Technical manual

Sea & Sea YS-D3 DUO instruction manual

Sea & Sea

Sea & Sea YS-D3 DUO instruction manual

Astral Pool LumiPlus 2.0 Installation and maintenance manual

Astral Pool

Astral Pool LumiPlus 2.0 Installation and maintenance manual

Sea & Sea YS-01 SOLIS instruction manual

Sea & Sea

Sea & Sea YS-01 SOLIS instruction manual

Alpine LED112T user manual

Alpine

Alpine LED112T user manual

EasyPro LED6WS Instructions for operation

EasyPro

EasyPro LED6WS Instructions for operation

RGBlue System 01/02:re instruction manual

RGBlue

RGBlue System 01/02:re instruction manual

OMD 5000w Tungsten Instructions for use

OMD

OMD 5000w Tungsten Instructions for use

Lumitec Kraken 101638 installation instructions

Lumitec

Lumitec Kraken 101638 installation instructions

Kripsol PEH100.C Manual for the installation, use and maintenance

Kripsol

Kripsol PEH100.C Manual for the installation, use and maintenance

Oase LunAqua 3 operating instructions

Oase

Oase LunAqua 3 operating instructions

Ros Q-LED II Operating and maintenance manual

Ros

Ros Q-LED II Operating and maintenance manual

Oase LunAqua Classic LED Set 1 operating instructions

Oase

Oase LunAqua Classic LED Set 1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.