Oxgard Praktika T-05 Quick start guide

Operational
manual
www.oxgard.com
Tel.+7(812) 366-15-94
Praktika T-05(K) speedgate


Operational manual 3
Contents
1. Product purpose........................................................................................ 5
2. Delivery set............................................................................................... 5
3. Basic specifications.................................................................................. 5
4. Product design.......................................................................................... 7
5. Transportation and storage....................................................................... 9
6. Safety requirements................................................................................ 10
7. Description of card collector.................................................................. 11
7.1. Card collector purpose .................................................................... 11
7.2. Product design................................................................................. 12
7.3. Removing guest cards from card collector ..................................... 13
8. Speedgate operation ............................................................................... 13
8.1. Turn on ............................................................................................ 13
8.2. Operating modes ............................................................................. 13
8.3. Control with remote control panel.................................................. 13
8.4. Adjustment of remote control panel ............................................... 15
8.5. Control with card collector ............................................................. 16
Appendix 1. Troubleshooting for speedgate.............................................. 18
Appendix 2. Troubleshooting for card collector........................................ 18

Praktika T-05(K) speedgate 4
List of abbreviations
PS – power supply
FA – fire alarm
RC – remote control
ACS – access control system
OD – operating device
Speedgate firmware version FW v1.4-2.2
Card collector firmware version FWv1.52

Operational manual 5
1. Product purpose
Praktika T-05 speedgate is designed for access control and pedestrian
flow management. The speedgate can be used at checkpoints at factories
and organizations, institutions, banks, schools, sports and entertainment
facilities, shops, railway stations, etc.
To ensure easy and quick passage of people it is recommended to
install one speedgate for every 500 people working in one shift.
2. Delivery set
Table 1. Delivery set
Item Qty, pcs.
Praktika
T
-
05
(К)
speedgate 1
Remote control panel with cable 1
Hatch lock key 8
Datasheet 1
Installation guidelines 1
Operational manual 1
SORMAT
PFG LB
12-50* anchor 12
М12х60 DIN912(GOST 11738-84) hexagon screw * 12
Connecting cable PVA 2x1,5* 2
Units arrangement diagram * 2
*-optional

Praktika T-05(K) speedgate 6
3. Basic specifications
Table 2 Basic specifications
Description Speedgate RC panel
Dimension of side unit with open wings
(mm) (HхWхL) 1050х1500х200
107х107х25
Dimension of side unit depending on
passage lane (mm)
660
900
1050х1500х500
1050х1500х620
107х107х25
Weight of side unit
depending on passage
lane, kg 660
900
110,0
113,0
0,5
Temperature range,
0
C
operation
- transportation and storage
+1...+40
+1...+40
+1...+40
+1...+40
Atmosphere relative humidity, no more
than % 80 80
Throughput, people per minute
30
Card collector capacity (pcs.)
**
More than 500
Max. number of connected RC panels, pcs 2
Lifetime, years 8 8

Operational manual 7
Table 3 Electrical specifications
Description Speedgate Card collector** RC panel
Supply voltage, V:
- nominal
- working
12,0
10,8...15,0
12,0
8…18,0
12,0
7,5...15,0
Average current
in standby
mode * A 0,4 0,2
Average current operational
mode * A 3,0
Maximal current of
1 side
unit*/***, A 5,0
Maximal current
of card
collector*, A 1,5
*- values mentioned at a nominal supply voltage
**-optional
***-
to form a passage area required 2 side units, i.e. 2 power supply 12V 5A
The manufacturer reserves the right to change the packaging, specifications and appearance
without notice
4. Product design
Speedgate housing
Speedgate housing is made of brushed stainless steel, wings are made
of tempered glass. The design of the speedgate can be equipped with an
integrated card collector. An access hatch is provided at the bottom of side
units for access to PU, RC and ACS cable holes (Fig. 1).

Praktika T-05(K) speedgate 8
Fig. 1 General view of speedgate
LED panel
Display panel of the speedgate is made of artificial stone with an
insertion made of acrylic glass. Speedgate operating modes are displayed
on the panel in the form of mnemonic signs depicting authorization and
non-authorization of passage (Fig. 2).

Operational manual 9
Fig. 2 General view LED panel display
Remote Control Panel
The housing of RC panel is made of polished stainless steel. On the
front side there are control buttons and LED indicators of RC operational
modes (Fig. 3). The standard supplied cable is 5 m long.
Fig. 3 General view of remote control

Praktika T-05(K) speedgate 10
5. Transportation and storage
Speedgate in its original packaging shall be transported by air, by
road and by railroad with protection from direct exposure to rain and dust
without range limitation. It is allowed to stack boxes in 2 rows during
transportation and storage if Euro-pallets used. Keep the speedgate in dry
(no moisture condensation) heated places within +1 to + 40 °C temperature
range. Avoid vapors of acids, alkalis, and corrosive gases at the storage
place. Storage of speedgate in the original package in a dry unheated
premises or closed transport containers is permitted for short periods, no
more than 3 days. Before startup, the speedgate must be kept in a room
with normal climate conditions for 12 hours after storage in unheated
rooms.
Dimensions of container - 1280х800х1650 mm (HxWxL).
6. Safety requirements
CAUTION! Failure to comply with the safety requirements specified in
this section may result in damage to human life and health, total or partial
loss of workability of products and (or) auxiliary equipment.
CAUTION! Specific guidance on the use of the speedgate:
1. The sensors are installed in the stands of speedgate at a height of 820
mm.
Children shorter than 820 mm cannot be identified by the speedgate.
Children must be accompanied by adults in charge when passing through
the speedgate!

Operational manual 11
Baggage, carts, bags etc. cannot be identified by the speedgate.
2. If there is no distance in the passage between the two visitors, they
might be identified as one.
CAUTION! Installation of speedgate must be carried out by qualified
personnel according to the instructions.
CAUTION! The producer disclaims any liability for damage to human life
and health, total or partial loss of workability of products and (or) auxiliary
equipment for non-compliance of the safety requirements specified in this
section, as well as terminate the product warranty.
IT IS NOT ALLOWED TO:
•Set the power supply inside the speedgate housing as this might lead
to electric shock to persons;
•Set the speedgate other than in dry and heated places;
•Impede or accelerate the speedgate wings;
•Apply chemically aggressive cleaning detergents (as pastes and
liquids) to the materials of the housing.

Praktika T-05(K) speedgate 12
7. Description of card collector
7.1. Card collector purpose
Card collector (Fig. 4) is designed for collection and storage of
proximity access cards at the exit from the facility. Flexible logic of the
controller allows the integration of the card reader with any access control
systems.
7.2. Product design
Fig 4. General view of the card collector

Operational manual 13
In front of the housing there is a hatch with lock for quick access to
collected cards and to the board where PS, OD and ACS cables are
connected. The hatch has card storage device where more than 500 cards
can be stored.
ATTENTION (!) Reader is not included in the delivery set.
Customer can choose reader model suitable for the existing system.
The reader is mounted on a universal adjustable bracket, located
under the top cover of the card collector. This solution provides maximum
flexibility for installation and connecting of the card collector.
7.3. Removing guest cards from card collector
7.3.1. Open the hatch lock of card collector with a key (Fig. 4).
7.3.2. Put a bag to collect cards (not supplied) underneath storage
device.
7.3.3. Lift the storage shutter to remove cards.
7.3.4. Lower the storage shutter and close the hatch with a key.
8. Speedgate operation
8.1. Turn on
Connect power supply units to 220V power network and turn them
on. Wings of speedgate will move to the starting position, the red cross
will appear on LED panels of the speedgate (Fig. 2) depicting non-

Praktika T-05(K) speedgate 14
authorization of passage. LED indicator of button 2 on the RC panel will
turn red (Fig. 3). The speedgate is ready for operation.
8.2. Operating modes
The speedgate has several modes of operation. The desired mode is
set by using RC panel or proximity cards. Operational modes are displayed
on the panel in the form of mnemonic signs depicting authorization and
non-authorization of passage.
8.3. Control with remote contron panel
General view of the RC panel is shown in Fig. 3. Each button is
equipped with the LED indicator displaying operation of the speedgate.
The "Stop" mode
"Stop" mode is set when the speedgate is turned on. Wings are
closed. Switch from another mode to "Stop" is performed by pressing
button 2, in this case LED indicator above button 2 turns red. In this mode
the passage is non-authorized in both directions.
The single passage mode
Button 1 (3) turns on single passage mode to the left (right). This
mode allowed one pass to the left (right) with a subsequent changing to
"Stop" mode. Green arrow indicator turns on on the display showing a free
passage to the left (right). Green LED indicator on the RC panel turns on
above the button corresponding to the authorized passage and a red

Operational manual 15
indicator - above button 2. If the passage is not perfromed within 5
seconds, the speedgate switches to "Stop" automatically.
Free passage mode
In order to swich to this mode press and hold button 1, then press button 3
and release both buttons. In this mode an unlimited number of passages is
allowed in both directions. Arrows turn on in both directions. Green LED
indicators on the RC panel LED turn on above the button 1 and 3.
"Antipanic" mode
This mode is turned on by pressing button 4 while in any other mode. In
this mode the speedgate will open wings towards exit direction. Green
indicator on the RC panel will turn on button 4.
8.4. Adjustment of remote control panel.
Speedgate can be set in various ways in relation to the user. In some
cases it is needed to reverse left / right passage buttons. This can be done
by the following operations:
• Power off the speedgate;
• Press and hold left (1) and right (3) buttons;
• Turn on the speedgate;
• Hold buttons 1 and 3, press button 2;
• Release buttons 1 and 3;
• Release button 2.
Now when you click left button passage will be allowed to the right
and vice versa. The current functions of the buttons is saved and do not

Praktika T-05(K) speedgate 16
reset when power is turned off. In order to return to the initial modification
it is needed to re-do the above sequence.
8.5. Control with card collector
The card collector is set in the standby mode after power-up. It is
necessary to present access card to switch the mode.
Passage with permanent cards
When an authorized permanent visitor card is presented to the reader
card collector unlocks the speedgate for the time specified by ACS
controller (depending on the operating mode; for 5 seconds in pulse
mode). During the specified time interval other cards are not accepted.
When the passage is performed or the specified time interval is expired
card collector switches into standby mode and can collect the next card.
Green arrow turns on on the LED panel, indicating the authorization of the
passage.
Passage with guest cards
Guest card shall be inserted into the card hole up to the stop
otherwise it will be ignored. In case the presented card is authorized, the
card collector collects it and then unlocks OD for 5 seconds.

Operational manual 17
Storage device is full
When the storage device is overfilled, the card collector stops
collecting guest cards and provides four short audio signals at intervals of
4 sec., the LED panel flashes red cross indicator at an interval of 4
seconds. Audio signal lasts for 3 minutes; then red cross on LED display
continues single blinks 1 time in 2 sec. Passages with permanent cards are
performed normally. In order to switch the card collector in the standard
operating mode, remove cards from the storage device (see. Article 7.3).
Emergency mode
During the operation of the card collector there might be a situation
when a card or a foreign object becomes jammed by shutter of the card
collector. To resolve such situations is an emergency mode.
•Open the hatch of the card collector using the key (Fig. 4);
•Press and hold BUT1 button on the board of the card collector (Fig.
5). When the button is pressed shutter is open forcedly and a
continuous audio signal is perfromed;
•Remove the object that impedes the normal operation of the system;
•Release BUT1 button and close the hatch with a key.

Praktika T-05(K) speedgate 18
Fig. 5. General view of board
Appendix 1. Troubleshooting for speedgate
Table 7. Troubleshooting for speedgate
Fault Remedy
PS unit is connected, but
the speedgate does not
work
Check the connection cable;
Check the fuses on motherboard
RC panel does not work
Check the RC panel connection;
If
+12 and GND contacts are connected
properly try to interchange positions of CL
and CH;

Operational manual 19
Appendix 2. Troubleshooting for card collector
LED(r/b)
L7113 F3C
Optotransistor (y/b) L7113
Fig 6. Location of optocouplers of card collector

Praktika T-05(K) speedgate 20
Table 8. Troubleshooting for the card collector
Fault Possible
causes Remedy
PS unit is
connected, but the
card collector does
not work
Check the connection cable;
Check the fuse on board of the card
collector;
Card collector
provides 4 audio
signals at
intervals of 3 sec,
red cross on the
LED panel flashes
every 4 seconds
(audio signals last
for 3 minutes;
then red cross on
the LED display
continues single
blinks 1 time in 2
sec.)
Storage
device is full Act in accordance with article 7.3;
Overflow
sensor
(
optocoupler
)
is broken (Fig.
6)
Check the condition of the cables and
connectors;
If D9 LED on the board of the card collector
does not turn red – the fault is caused by the
malfunction of motherboard;
If D9 LED on the board of the card collector
turns red:
set the jumper on Full_ph connector - if LED
D9 then goes off, the alarm stops, the Red
Cross does not blink – the fault is caused by
defective optocoupler;
Check the voltage at the connectors
(without removing the connectors, while
holding down BUT1 button):
1. Full_ph (Vtyp = 0,15 B; Vmax = 2,5
V): - If V ≤2,5 In - all right;
- If V> 2,5 V – disaligment or LED
and phototransistor fault;
- If V = 5 V - the phototransistor or
cable are defective;
2. IR LED3 (Vtyp = 1,2 B):
- If V = 5 V - LED or cable defective;
Other manuals for Praktika T-05
2
This manual suits for next models
1
Table of contents
Other Oxgard Other manuals
Popular Other manuals by other brands

Tetra
Tetra APS 100 instruction manual

White Rodgers
White Rodgers 8A04-1 installation instructions

CEMO
CEMO KS-Mobil Easy 120l operating instructions

macromatic
macromatic PMP Series installation instructions

Russound
Russound SPEAKER ROUGH-IN KIT instruction manual

pitsco