manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PACH & COMPANY
  6. •
  7. Intercom System
  8. •
  9. PACH & COMPANY Quantum QR5 Series User manual

PACH & COMPANY Quantum QR5 Series User manual

•Missing Parts, contact Pach and Company 1-888-678-7224
•Defective system under manufacturer warranty,
call 1-888-678-7224 for advance replacement
•24 Months warranty for complete system
•6 Months warranty for Printed Circuit Board
Exit program, cancel call
25
Keypad beep
0= disable (default)
1=enable
Save program
26
Door beep
0= disable
1= enable (default)
00
Change master code (0000 is
default)
27
Talk time (060-240
second). Default=60
second
01
Add new forwarding tenant’s
directory
28
Unlock relay1 time
(12-99 second). Default=
12 second
02
Edit existing tenant’s directory
29
Unlock relay2 time
(12-99 second). Default=
12 second
03
Delete existing tenant’s
directory
30
Call Forwarding
0= disable 1= enable
04
Clear all forwarding tenant’s
directory
31
Call forwarding time
05-60 second
05
Call Forwarding
32
Forwarding directory
0-9
06
New access code
33
Temporary code
07
Delete access code
34
Special code
08
Clear all access code
35
Temporary card
09
Access code digit (4-8 digit).
Default is 4-digit
36
Special card
10
Add new card
37
Initiate premise call
0=**, 1=## (default)
11
Delete card
38
System acknowledge
(0-9). Default= 3
12
Clear all card
39
Remote access
0= disable
1=enable (default)
13
Set time
40
DTMF relay 1 (1-9).
Default=9
14
Set date
41
DTMF relay 2 (1-9).
Default=8
15
Initializing event recording
42
Relay 2 Mode
1= door control (default)
2= relay 2 trigger
simultaneously as relay 1
3= enable if function code 24
is enable
4= turn relay 2 on and off
On=7, Off=6
16
AUS= auto unlock schedule
(0-9 schedule)
43
DND: do not disturb time
zone (0-9)
17
TMZ= time zone. 20 TMZ, 00-
20.
44
Disable Time zone relay
1, 2 or both
18
HLD= holiday zone. 20 HLD,
1-20
45
Relay 1 and 2 unlock
timer
20
AUXIN1
0= disable (default)
1= enable control by relay 1 open
interval
2= relay 1 control by AUXIN1
46
Firmware version
21
AUXIN2
0= disable (default)
1= enable control by relay 2 open
interval
2= relay 2 control by AUXIN2
48
PBX enable. Default=
disable
22
Do not disturb
0= disable (default), 1= enable
23
Lock-out Count
49
Edit Access code
24
Alarm
0= disable
1= local beep for 60 seconds
2= disable system for 60 seconds
with no beep
3= call directory (0-9)
50
Erase the memory to
factory default
51
Welcome screen
Log on to programming: Press and
simultaneously then release, the
welcome message will stop scrolling
(repeat if screen still scrolls) enter 4-digit
“MASTER CODE” (0000 is default), the
screen will show:
Select the “Function Code” from the table
OPERATION
Opening the door remotely press (relay 1) or (relay 2)
Opening the door with the access code press (display screen
will stop scrolling) then press a valid 4-digit access code.
Extending talk time tenant must press from the phone after the
time out warning beep.
Calling into the system from premise location (Intercom)
1. Press or depending on function code 37, then
press to communicate with the person
Calling into the system from remote location:
Enable function code 39
1. Call the system phone number, hear one beep if the system
answering the call.
2. Press then 4-digit master code, hear one short beep
3. Press to establish two way communication
4. Press or to release the door.
Call waiting: function code 38 must be set 1-9 and function code 39
can be set either 1 or 0, press on your phone to transfer between
calls
See Function Code 37
Premise
Relay 1
Relay 2
Open cycle
##9/**9
##5/**9
Open hold
##8/**8
##4/**4
Close
##7/**7
##3/**3
QR5IP and QR5IPFF DEFAULT IP
IP: 192.168.1.230
SUBNET: 255.255.255.0
GATEWAY: 192.168.1.1
DNS: 192.168.1.1
USERNAME: Administrator
PASSWORD: 8888
OPERATION
TO CALL FROM THE SYSTEM
1. INTERCOM MODE PRESS
2. CALL FORWARDING MODE, press to scroll name from A-Z or
to scroll name from Z-A then press to call name selected.
Opening the door remotely press (relay 1) or (relay 2)
1. INPUT POWER 12VAC 40VA SUPPLIED (voltage measurement must be 12.5-14.0 VAC) OR 12VDC 2A adjustable
power supply (voltage measurement must be 13.5-14.0 VDC)
2. 12 VDC 4Ahr BATTERY BACK-UP (OPTIONAL) WARNING: THIS IS NOT INPUT POWER
3. DOOR 2 DRY CONTACT RELAY, MUST USE SEPARATE POWER FOR DOOR STRIKE
4. DOOR 1 DRY CONTACT RELAY, MUST USE SEPARATE POWER FOR DOOR STRIKE
5. CONNECT NTEL1 and NTEL2 TO PIN 3 AND PIN 4 ON BYPASS MODULE
DO NOT USE NTEL1 AND NTEL2 IF DEDICATED DIALT TONE IS USE, SEE STEP 6
6. CONNECT CO1 AND CO2 TO PIN 1 AND PIN 2 ON BY PASS MODULE
CONNECT THE DIAL TONE TO CO1 AND CO2 WITHOUT USING A THE BYPASS MODULE IF DEDICATED DIALT TONE
IS USED FOR THE SYSTEM.
7. AUX 1 AND AUX 2 FOR EXIT SWITCH, LOOP DETECTOR OR ANY INPUT DEVICE WITH DRY CONTACT OUTPUT.
8. DOORS1 AND DOORS 2 SENSOR. WARNING: THESE ARE NOT DOOR CONTACTS
9. RS-485 PORT, CONNECT TO SLAVE UNITS (USCR, UCRM, USKP AND USKPR) UP TO 8 UNITS
10. 26-WIEGAND INPUT. PROPRIETARY CARD READER IS BUILT-IN ON THE QC SERIES. DISCONNECT THE BUILT-IN
READER IF YOU ARE USING YOUR OWN CARD READER.
11. FACTORY USE “ONLY” TO POWER THE QWCM IP MODULE AND FAN. WARNING: “DO NOT USE THE +12VDC
POWER TO POWER ANY OTHER DEVICES”.
12. CONNECT THE ANALOG DIAL TONE TO THE BYPASS MODULE PHONE CO
13. CONNECT THE HOME TELEPHONE TO THE BYPASS MODULE HOME
Technical Support is available
Monday-Friday 7:00 am-4:00 pm PST at 1-888-678-7224
Technical Info and complete manual are available online
www.pach-co.com

Other manuals for Quantum QR5 Series

1

Other PACH & COMPANY Intercom System manuals

PACH & COMPANY QUANTUM Q7000VOIP Series User manual

PACH & COMPANY

PACH & COMPANY QUANTUM Q7000VOIP Series User manual

PACH & COMPANY AeGIS 7000 Series Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS 7000 Series Assembly instructions

PACH & COMPANY AeGIS 7000 Series Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS 7000 Series Assembly instructions

PACH & COMPANY PAC-7000VFF Assembly instructions

PACH & COMPANY

PACH & COMPANY PAC-7000VFF Assembly instructions

PACH & COMPANY AeGIS 7000SV User manual

PACH & COMPANY

PACH & COMPANY AeGIS 7000SV User manual

PACH & COMPANY Aegis 7000 Plus Assembly instructions

PACH & COMPANY

PACH & COMPANY Aegis 7000 Plus Assembly instructions

PACH & COMPANY Quantum Q9000iP Series User manual

PACH & COMPANY

PACH & COMPANY Quantum Q9000iP Series User manual

PACH & COMPANY Aegis 7000 Plus User manual

PACH & COMPANY

PACH & COMPANY Aegis 7000 Plus User manual

PACH & COMPANY AeGIS NPB9000P Series Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS NPB9000P Series Assembly instructions

PACH & COMPANY AeGIS 8000 PLUS Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS 8000 PLUS Assembly instructions

PACH & COMPANY AeGIS 7000S Series User manual

PACH & COMPANY

PACH & COMPANY AeGIS 7000S Series User manual

PACH & COMPANY QUANTUM QVOiP SERIES User manual

PACH & COMPANY

PACH & COMPANY QUANTUM QVOiP SERIES User manual

PACH & COMPANY QUANTUM QC Series User manual

PACH & COMPANY

PACH & COMPANY QUANTUM QC Series User manual

PACH & COMPANY AeGIS 4000 Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS 4000 Assembly instructions

PACH & COMPANY QUANTUM Q5VOIP User manual

PACH & COMPANY

PACH & COMPANY QUANTUM Q5VOIP User manual

PACH & COMPANY AeGIS 8000 Series Assembly instructions

PACH & COMPANY

PACH & COMPANY AeGIS 8000 Series Assembly instructions

PACH & COMPANY AEGIS 7250P Assembly instructions

PACH & COMPANY

PACH & COMPANY AEGIS 7250P Assembly instructions

PACH & COMPANY 7000SC User manual

PACH & COMPANY

PACH & COMPANY 7000SC User manual

PACH & COMPANY QUANTUM QC1 Assembly instructions

PACH & COMPANY

PACH & COMPANY QUANTUM QC1 Assembly instructions

PACH & COMPANY AeGIS 7000V Series User manual

PACH & COMPANY

PACH & COMPANY AeGIS 7000V Series User manual

Popular Intercom System manuals by other brands

Aiphone GF-NS Operation manual

Aiphone

Aiphone GF-NS Operation manual

TCS Carus Adapto instruction manual

TCS

TCS Carus Adapto instruction manual

Olympia VDB 824YA manual

Olympia

Olympia VDB 824YA manual

Aiphone GT-1C Operation manual

Aiphone

Aiphone GT-1C Operation manual

UNIVIEW OET-515H user manual

UNIVIEW

UNIVIEW OET-515H user manual

Honeywell ETCS operation instruction

Honeywell

Honeywell ETCS operation instruction

Ritron DoorCom owner's manual

Ritron

Ritron DoorCom owner's manual

Xenon FEVER DEFENCE Assembly instructions

Xenon

Xenon FEVER DEFENCE Assembly instructions

Extel LENA 18.3 Installation and user guide

Extel

Extel LENA 18.3 Installation and user guide

Chamberlain ROI2 user guide

Chamberlain

Chamberlain ROI2 user guide

Slinex Imani Usual manual

Slinex

Slinex Imani Usual manual

Panasonic VL-SWD272 quick start guide

Panasonic

Panasonic VL-SWD272 quick start guide

Vimar 62IG Installer's guide

Vimar

Vimar 62IG Installer's guide

Aiphone VGX installation manual

Aiphone

Aiphone VGX installation manual

urmet domus 1723 Quick user guide

urmet domus

urmet domus 1723 Quick user guide

STI STI-3360 quick start guide

STI

STI STI-3360 quick start guide

Vimar Elvox 3301 Mounting instructions

Vimar

Vimar Elvox 3301 Mounting instructions

3M Signature Series operating instructions

3M

3M Signature Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.