INSTALLATION GUIDE FFLA generation 2 Series LED Flood
Instructions and specifications are subject to change at any time without notice. Copyright© 2021 PacLights All Rights Reserved Page 3 of 4
Need help? (800) 988 -6386 Email: CS@PacLights.com Website: www.PacLights.com
PL_INST_FFLA/2_v0
FFLA/2 YOKE MOUNT
The Yoke Mount is available for all FFLA/2 fixtures. If installed,
remove the Flood Mount by removing the the Cap Head Screws
(Refer to Fig. 7). Install the Yoke Mount, Cap Head Screws and
Washers by aligning to the holes (4) at the base of the FFLA/2 70/90
fixture (Fig. 12). The FFLA/2 15/30 & 50 fixtures have an Adapter
Spacer for the fixture Cable that fits between the fixture and the
Yoke Mount (Fig. 13). Fasten with the Cap Head Screws and Washers
provided.
1
2
FIG. 12
FFLA/2 FIXTURE
YOKE MOUNT
FIG. 15
FIG. 13
3
The FFLA/2 Yoke Mount drilling patterns (Fig. 14).
The Yoke Mount can be mounted to a Wall/Surface. Align the Yoke
Mount to the holes pre-drilled on the mounting surface and bolt the
fixture to the wall (appropriate mounting Bolts, Washers, and Nuts
not included) (Fig. 15).
WASHER
FFLA/2 - 70/90
FIG. 14 FFLA/2 - 15/30 & 50
BOLTS
WALL / SURFACE
NUT
WASHER
HOLES
~
The Yoke Mount can be rotated. Loosen the center Cap Head Screws
(2) and remove the smaller Cap Head Screws to adjust the tilt angle
of the FFLA/2 fixture to point towards the desired location. Replace
the smaller Cap Head Screws and tighten all of the Cap Head Screws
to hold the fixture in place (Fig. 16).
4
FIG. 16
ADAPTER
SCREWS
The Slipfitter Mount is only available for FFLA/2 70/90 fixtures. If
installed,
remove the Flood Mount by removing the the Cap Head
Screws (Refer to Fig. 7). Install the FFLA/2 Slipfitter Mount with
Mount, Plate, Screws, Washers, and Lock Washers
(Fig. 17)
.
1
FFLA/2 SLIPFITTER MOUNT
FIG. 17
MOUNT
PLATE
SLIPFITTER
SCREW
WASHER
LOCK WASHER
The Slipfitter Mount can be mounted on a Round Pole (Fig. 18)
. Run
the FFLA/2 Cable from the FFLA/2 fixture and the Slipfitter Mount
to the Pole and follow the Wiring Diagram provided to properly
install the light fixture to the Power Supply Cable. All wiring must
be installed by a certified electrician and must be compliant to NEC
standards. Tighten the Slipfitter Screws (4) to secure the FFLA/2
fixture to the Round Pole.
2
FFLA/2 FIXTURE
FIG. 18
SLIPFITTER
FFLA/2 FIXTURE
ROUND POLE
POWER CABLE
FFLA/2 CABLE
SCREW
If needed to tilt the FFLA/2 fixture, loosen the Socket Head Screw to
unmate the teeth of the Fixture Mount and the Slipfitter and rotate
(Fig. 19)
.
3
FIG. 19 SCREW
SLIPFITTER
FFLA/2 FIXTURE
SCREWS
FFLA/2 15/30 & 50
FFLA/2 70/90
FIXTURE
MOUNT