INSTALLATION GUIDE FFLA generation 2 Series LED Flood
Instructions and specifications are subject to change at any time without notice. Copyright© 2021 PacLights All Rights Reserved Page 1 of 4
Need help? (800) 988 -6386 Email: CS@PacLights.com Website: www.PacLights.com
PL_INST_FFLA/2_v0
FFLA/2 3CCT (Color Coordinated Temperature) & LUMEN FIELD SELECTABLE WITH PHOTO CONTROL
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
PacLights fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR
WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNINGS:
• Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
• To prevent wiring damage or abrasion, do not expose wiring to edges of sharp objects.
CAUTION:
• For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly. Apply weatherproof silicone
sealant around the edge of the Back Box and/or Junction Box. This is especially important with an uneven wall surface. Silicone all plugs and
unused conduit entries.
FIG. 1
FFLA/2 15/30 FFLA/2 50 FFLA/2 70/90
The Selectable CCT & Lumen output is equipped on selected models.
If the CCT or Lumen output needs to be adjusted or if the Photo
Control turned on/o, remove the clear plastic Cap Screw from
the back of the FFLA/2fixture (Fig. 1). The Dip Switches can be
accessed easliy inside the fixture (Fig. 1a).
Connect the ACL and the ACN from the FFLA/2 Fixture to the conduit with the AC power Supply Cable. Follow the Wiring Diagram provided.
AC POWER SUPPLY
FFLA/2 DRIVER
GRAY (-)
PURPLE (+)
HOT [BLACK]
NEUTRAL [WHITE]
GROUND [GREEN]
WIRING DIAGRAM
DIM
INPUT
There is a Dip Switch Chart to follow next to the Dip Switches inside.
The first set of Switches controls the Lumen output. The second set
controls the Photo Control ON/OFF and the Color Temperature
(Fig. 2). After the selection is made replace the clear plastic Cap
Screw and carefully tighten.
BACK
COVER
FFLA/2 FIXTURE
CAP SCREW
FIG. 1a
12
DIP SWITCHES
DIP SWITCHES
80% 100%
70% 90%
PH ON
PH OFF
3000K
4000K
5000K
FIG. 2

INSTALLATION GUIDE FFLA generation 2 Series LED Flood
Instructions and specifications are subject to change at any time without notice. Copyright© 2021 PacLights All Rights Reserved Page 2 of 4
Need help? (800) 988 -6386 Email: CS@PacLights.com Website: www.PacLights.com
PL_INST_FFLA/2_v0
The Knuckle Mount is available for all FFLA/2 fixtures. If installed,
remove the Flood Mount by removing the Screws (Fig. 7). Install the
Knuckle Mount, Plate, and rubber Wire Grommet by aligning to the
holes (2) at the base of the FFLA/2 fixture. Fasten them with the
Cap Head Screws and Washers provided (Fig. 8).
FFLA/2 KNUCKLE MOUNTFFLA/2 FLOOD MOUNT
The Flood Mount available for all FFLA/2 fixtures (Fig. 3).
FIG. 6
BOLTS
KNUCKLE
MOUNT
FIG. 3
FIG. 5
FFLA/2
FIXTURE
FLOOD
MOUNT
SCREW
1
FIG. 9
FIG. 10
CONDUIT
FFLA/2 FIXTURE
CABLE
J-BOX COVER
1
LOCKWASHER
Follow the Wiring Diagram and properly wire the FFLA/2 fixture to
the Power Supply Cable from the Conduit. Fasten the Junction Box
Cover to the Junction Box with the Screws (not included) (Fig. 10).
3
J-BOX COVER
JUNCTION
BOX
FFLA/2 FIXTURE
FIG. 11
Loosen the Socket Head Screw on the Knuckle Mount and pull apart
to separate the teeth and adjust the tilt angle to the desired position.
Once adjusted, align the teeth and fasten the Screw to lock the
Knuckle Mount and FFLA/2 fixture in place (Fig. 11).
4
SCREW KNUCKLE
MOUNT
FFLA/2 FIXTURE
The FFLA/2 Knuckle Mount can be mounted directly to a Junction
Box. Install the fixture to a J-Box Cover with a conduit threaded
opening. Fasten the J-Box Cover and lock in place with the
Lockwasher included with the FFLA/2 (Fig. 9).
2
SCREWS
KNUCKLE
MOUNT
PLATE
GROMMET
FIG. 7 FIG. 8
The FFLA/2 Flood Mount drilling patterns (Fig. 4).
2
NUT
WASHER
WALL / SURFACE
HOLES
~
FLOOD MOUNT FFLA/2 FIXTURE
FFLA/2 FIXTURE
The Flood Mount can be rotated. Loosen the Cap Head Screws (2)
and adjust the tilt angle of the FFLA/2 fixture to point towards the
desired location. Tighten the Screws to hold the FFLA/2 fixture in
place (Fig. 6).
4
FLOOD MOUNT
FFLA/2 FIXTURE
SCREW
The Flood Mount can be mounted to a Wall/Surface. Align the Flood
Mount to the holes pre-drilled on the mounting surface and bolt the
fixture to the wall (appropriate mounting Bolts, Washers, and Nuts
not included) (Fig. 5).
3
FIG. 4 FFLA/2 - 70/90
FFLA/2 - 15/30 FFLA/2 - 50
POWER SUPPLY
CABLE
FFLA/2 FIXTURE
CABLE

INSTALLATION GUIDE FFLA generation 2 Series LED Flood
Instructions and specifications are subject to change at any time without notice. Copyright© 2021 PacLights All Rights Reserved Page 3 of 4
Need help? (800) 988 -6386 Email: CS@PacLights.com Website: www.PacLights.com
PL_INST_FFLA/2_v0
FFLA/2 YOKE MOUNT
The Yoke Mount is available for all FFLA/2 fixtures. If installed,
remove the Flood Mount by removing the the Cap Head Screws
(Refer to Fig. 7). Install the Yoke Mount, Cap Head Screws and
Washers by aligning to the holes (4) at the base of the FFLA/2 70/90
fixture (Fig. 12). The FFLA/2 15/30 & 50 fixtures have an Adapter
Spacer for the fixture Cable that fits between the fixture and the
Yoke Mount (Fig. 13). Fasten with the Cap Head Screws and Washers
provided.
1
2
FIG. 12
FFLA/2 FIXTURE
YOKE MOUNT
FIG. 15
FIG. 13
3
The FFLA/2 Yoke Mount drilling patterns (Fig. 14).
The Yoke Mount can be mounted to a Wall/Surface. Align the Yoke
Mount to the holes pre-drilled on the mounting surface and bolt the
fixture to the wall (appropriate mounting Bolts, Washers, and Nuts
not included) (Fig. 15).
WASHER
FFLA/2 - 70/90
FIG. 14 FFLA/2 - 15/30 & 50
BOLTS
WALL / SURFACE
NUT
WASHER
HOLES
~
The Yoke Mount can be rotated. Loosen the center Cap Head Screws
(2) and remove the smaller Cap Head Screws to adjust the tilt angle
of the FFLA/2 fixture to point towards the desired location. Replace
the smaller Cap Head Screws and tighten all of the Cap Head Screws
to hold the fixture in place (Fig. 16).
4
FIG. 16
ADAPTER
SCREWS
The Slipfitter Mount is only available for FFLA/2 70/90 fixtures. If
installed,
remove the Flood Mount by removing the the Cap Head
Screws (Refer to Fig. 7). Install the FFLA/2 Slipfitter Mount with
Mount, Plate, Screws, Washers, and Lock Washers
(Fig. 17)
.
1
FFLA/2 SLIPFITTER MOUNT
FIG. 17
MOUNT
PLATE
SLIPFITTER
SCREW
WASHER
LOCK WASHER
The Slipfitter Mount can be mounted on a Round Pole (Fig. 18)
. Run
the FFLA/2 Cable from the FFLA/2 fixture and the Slipfitter Mount
to the Pole and follow the Wiring Diagram provided to properly
install the light fixture to the Power Supply Cable. All wiring must
be installed by a certified electrician and must be compliant to NEC
standards. Tighten the Slipfitter Screws (4) to secure the FFLA/2
fixture to the Round Pole.
2
FFLA/2 FIXTURE
FIG. 18
SLIPFITTER
FFLA/2 FIXTURE
ROUND POLE
POWER CABLE
FFLA/2 CABLE
SCREW
If needed to tilt the FFLA/2 fixture, loosen the Socket Head Screw to
unmate the teeth of the Fixture Mount and the Slipfitter and rotate
(Fig. 19)
.
3
FIG. 19 SCREW
SLIPFITTER
FFLA/2 FIXTURE
SCREWS
FFLA/2 15/30 & 50
FFLA/2 70/90
FIXTURE
MOUNT

INSTALLATION GUIDE FFLA generation 2 Series LED Flood
Instructions and specifications are subject to change at any time without notice. Copyright© 2021 PacLights All Rights Reserved Page 4 of 4
Need help? (800) 988 -6386 Email: CS@PacLights.com Website: www.PacLights.com
PL_INST_FFLA/2_v0
The Arm Mount drilling template is for either a Square or Round
pole (Fig. 21). Drill holes on the Square pole by following the Drilling
Template to mount the FFLA/2 to the desired height (Fig. 22).
2
FIG. 21
The Arm Mount is only available for FFLA/2 70/90 fixtures (Fig. 20).
The Arm Mount can be mounted on either a Square or Round pole.
1
FIG. 20
SIDE PLATE
ARM MOUNT
SCREWS
FFLA/2 ARM MOUNT
LOCKING PLATE
SQUARE POLE
GASKET
ROUND POLE
GASKET
WASHER
LOCK
WASHER
SCREW
If the FFLA/2 fixture is being installed to a Square Pole, remove the
Round Pole Gasket (Fig. 23).
3
FIG. 23
FIG. 22
SQUARE
POLE
ROUND POLE
GASKET
ARM MOUNT
FIG. 24
FIG. 27 SCREW
LOCKING
PLATE
SQUARE POLE
GASKET
MOUNTING
POLE
POWER CABLE
Run the Power Cable through the Pole. Place the Locking Plate and
Gasket inside the Mounting Pole and fasten the FFLA/2 fixture with
the Arm Mount onto the Pole with the Cap Head Screws (Fig. 27).
For the Round Pole, repeat Steps 2-6, except the remove the Square
Pole Gasket for Step 2. Reinstall the Side Plate (Fig. 24).
7
FIG. 26 FFLA/2 CABLE
Run the FFLA/2 Cable through the inside the Arm Mount. Align the
hole and teeth from the Arm Mount with the FFLA/2 Mount and use
the Cap Head Screw to fasten them together at the desired fixture
tilt angle (Fig. 26).
6
FFLA/2 MOUNT
SCREW
Remove the Screws (4) and the Side Plate from the Arm Mount
before installing the FFLA/2 fixture (Fig 24).
4
ARM MOUNT
ARM MOUNT
FFLA/2 FIXTURE
Place the Fixture Mount on the FFLA/2 fixture and fasten them
together with the Screws and Washers (Fig. 25).
5
SCREW
WASHER
FIXTURE
MOUNT
FFLA/2 FIXTURE
FIG. 25
FFLA/2 CABLE
This manual suits for next models
5
Other PacLights Floodlight manuals
Popular Floodlight manuals by other brands

Vaxcel
Vaxcel T0175 Assembly and installation instructions

Ecco
Ecco VIGILED II Installation and operation instruction

Larson Electronics
Larson Electronics EPLC2-WPLED-50W-RT instruction manual

Jula
Jula 420-147 operating instructions

Tronios
Tronios Beamz BMS20 instruction manual

ACME
ACME BW-545 user manual