manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PacLights
  6. •
  7. Floodlight
  8. •
  9. PacLights FFLE Series User manual

PacLights FFLE Series User manual

INSTALLATION GUIDE FFLE Series LED Flood
Instructions and specifications are subject to change at any time without notice. Copyright© 2021 PacLights All Rights Reserved Page 1 of 3
Need help? (800) 988 -6386 Email: CS@PacLights.com Website: www.PacLights.com
PL_INST_FFLE_v0
FFLE FLOOD MOUNT
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
PacLights fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR
WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNINGS:
• Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
• To prevent wiring damage or abrasion, do not expose wiring to edges of sharp objects.
CAUTION:
• For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly. Apply weatherproof silicone
sealant around the edge of the Back Box and/or Junction Box. This is especially important with an uneven wall surface. Silicone all plugs and
unused conduit entries.
FIG. 1
FFLE 100 FFLE 150 FFLE 200 / 240
Connect the ACL and the ACN from the FFLE Fixture to the conduit with the AC power Supply Cable. Follow the Wiring Diagram provided.
AC POWER SUPPLY
FFLE DRIVER
GRAY (-)
PURPLE (+)
HOT [BLACK]
NEUTRAL [WHITE]
GROUND [GREEN]
WIRING DIAGRAM
DIM
INPUT
2
FIG. 2
The Flood Mount is available for all FFLE fixtures (Fig. 1).
1
FLOOD MOUNT
FFLE FIXTURE
The Flood Mount can be removed for all FFLE fixtures. If installed,
remove the Flood Mount by removing the Screws, Lock Washers,
Washers, and Angle Knobs (Fig. 2).
FLOOD
MOUNT
ANGLE KNOB
LOCKWASHER
WASHER
SCREW
INSTALLATION GUIDE FFLE Series LED Flood
Instructions and specifications are subject to change at any time without notice. Copyright© 2021 PacLights All Rights Reserved Page 2 of 3
Need help? (800) 988 -6386 Email: CS@PacLights.com Website: www.PacLights.com
PL_INST_FFLE_v0
FFLE FLOOD MOUNT
FIG. 5
BOLTS
FIG. 4
The FFLE Flood Mount drilling patterns (Fig. 3).
3
NUT
WASHER
WALL / SURFACE
HOLES
~
FFLE FIXTURE
The Flood Mount can be rotated. Loosen the Cap Head Screws (2)
and adjust the tilt angle of the FFLE fixture to point towards the
desired location. Tighten the Screws to hold the FFLE fixture in place
(Fig. 5).
5
FLOOD MOUNT FFLE FIXTURE
SCREW
The Flood Mount can be mounted to a Wall/Surface. Align the Flood
Mount to the pre-drilled holes on the mounting surface and fasten
the fixture to the wall (appropriate mounting Bolts, Washers, and
Nuts not included) (Fig. 4).
4
FIG. 3 FFLE - 200/240
FFLE - 100 FFLE - 150
WASHER
NUT
FFLE TRUNNION MOUNT
The Trunnion Mount is available for all FFLE fixtures. If installed,
remove the Flood Mount by removing the the Cap Head Screws
(Refer to Fig. 2). Install the Trunnion Mount, Cap Head Screws, Lock
Washers, and Washers by aligning to the holes (4) at the base of the
FFLE fixture (Fig. 6).
1
2
FIG. 6
FFLE FIXTURE
TRUNNION
MOUNT
FIG. 8
3
The FFLE Trunnion Mount drilling patterns (Fig. 7).
The Trunnion Mount can be mounted to a Wall/Surface. Align the
Trunnion Mount to the pre-drilled holes on the mounting surface and
fasten the fixture to the wall (appropriate mounting Bolts, Washers,
and Nuts not included) (Fig. 8).
WASHER
FFLE - 100/150/200/240
FIG. 7
BOLTS
WALL / SURFACE
NUT
WASHER
HOLES
~
The Trunnion Mount can be rotated. Loosen the center Cap Head
Screws (2) and remove the smaller Cap Head Screws to adjust the tilt
angle of the FFLE fixture to point towards the desired angle. Replace
the smaller Cap Head Screws and tighten all of the Cap Head Screws
to hold the fixture in place (Fig. 9).
4
FIG. 9
SCREW
SCREW
FFLE FIXTURE
LOCK WASHER
FFLE FIXTURE
TRUNNION
MOUNT
INSTALLATION GUIDE FFLE Series LED Flood
Instructions and specifications are subject to change at any time without notice. Copyright© 2021 PacLights All Rights Reserved Page 3 of 3
Need help? (800) 988 -6386 Email: CS@PacLights.com Website: www.PacLights.com
PL_INST_FFLE_v0
The Slipfitter Mount is available for all FFLE fixtures. If installed,
remove the Flood Mount by removing the the Cap Head Screws
(Refer to Fig. 2). Install the FFLE Slipfitter Mount with the Mount,
Screws, Washers, and Lock Washers
(Fig. 10)
.
1
FFLE SLIPFITTER MOUNT
FIG. 10
MOUNT
SLIPFITTER SCREW
WASHER
LOCK WASHER
The Slipfitter Mount can be mounted on a Round Pole (Ø2 3/8”)
(Fig. 11)
. Run the FFLE Cable from the FFLE fixture and the
Slipfitter Mount to the Pole and follow the Wiring Diagram provided
to properly install the light fixture to the Power Supply Cable. All
wiring must be installed by a certified electrician and must be
compliant to NEC standards. Tighten the Slipfitter Screws (4) to
secure the FFLE fixture to the Round Pole at the desired orientation.
2
FFLE FIXTURE
FIG. 11
SLIPFITTER
FFLE FIXTURE
ROUND POLE
POWER CABLE FFLE CABLE
SCREW
The FFLE fixture can be tilted. Remove the Screws (2) on the
Slipfitter Cover, remove the Cover, loosen the Socket Head Screw to
unmate the teeth of the Fixture Mount and the Slipfitter and rotate
(Fig. 12)
. When the desired tilt angle is adjusted replace all parts in
the reverse order.
3
FIG. 12
SCREW
SLIPFITTER
FFLE FIXTURE
COVER
SOCKET SCREW
WASHER LOCK WASHER

This manual suits for next models

4

Other PacLights Floodlight manuals

PacLights FFHS Series Assembly instructions

PacLights

PacLights FFHS Series Assembly instructions

PacLights FFLA 2 Series User manual

PacLights

PacLights FFLA 2 Series User manual

PacLights FFHS/2 Series Assembly instructions

PacLights

PacLights FFHS/2 Series Assembly instructions

PacLights FCPG Series Assembly instructions

PacLights

PacLights FCPG Series Assembly instructions

Popular Floodlight manuals by other brands

BridgeLux Flexidel BASIC-FLOOD-10W quick start guide

BridgeLux

BridgeLux Flexidel BASIC-FLOOD-10W quick start guide

WE-EF FLC280 Installation and maintenance instructions

WE-EF

WE-EF FLC280 Installation and maintenance instructions

PROMETHEUS LIGHTS FOURSEVENS MAELSTROM MX3F quick start guide

PROMETHEUS LIGHTS

PROMETHEUS LIGHTS FOURSEVENS MAELSTROM MX3F quick start guide

brennenstuhl RUFUS 1500 MA operating instructions

brennenstuhl

brennenstuhl RUFUS 1500 MA operating instructions

Daintree GE current Evolve EFM1 installation guide

Daintree

Daintree GE current Evolve EFM1 installation guide

MediaLas Midget RGB user manual

MediaLas

MediaLas Midget RGB user manual

Elinchrom ScanLight Halogen - 20998 user manual

Elinchrom

Elinchrom ScanLight Halogen - 20998 user manual

ADJ ULTRA HEX PAR3 User instructions

ADJ

ADJ ULTRA HEX PAR3 User instructions

Leviton RS Series installation instructions

Leviton

Leviton RS Series installation instructions

Sealey MD500c.V2 instructions

Sealey

Sealey MD500c.V2 instructions

Life 39.9F4070C user manual

Life

Life 39.9F4070C user manual

LUTEC 7635202053 owner's manual

LUTEC

LUTEC 7635202053 owner's manual

e-conolight E-X1ML1006 Installation, operation and maintenance instructions

e-conolight

e-conolight E-X1ML1006 Installation, operation and maintenance instructions

Miller Edge MLC-K36 installation instructions

Miller Edge

Miller Edge MLC-K36 installation instructions

LIGMAN PIB-50022 installation manual

LIGMAN

LIGMAN PIB-50022 installation manual

Arcadia D3 Plus Desert RAU24R Installation and maintenance instructions

Arcadia

Arcadia D3 Plus Desert RAU24R Installation and maintenance instructions

SCANGRIP FLOOD LITE M manual

SCANGRIP

SCANGRIP FLOOD LITE M manual

Chauvet Intimidator Scan 305 IRC user manual

Chauvet

Chauvet Intimidator Scan 305 IRC user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.