PAG PAGlink PowerHub User manual

U5134
PowerHub
V-Mount & Gold Mount
User Guide

PAG Ltd.
Epsom Downs Metro Centre
Units 9 & 10
Waterfield
Tadworth
Surrey KT20 5LR
United Kingdom
T: +44 (0)20 8543 3131
www.paguk.com
Disclaimer
The information contained in this document is correct at the
time of publication. PAG Ltd. reserves the right to change
specifications or product details without notification. Changes
to product details will be incorporated in the next version of
the document. PAG updates documents on a regular basis.
Trademarks
All PAG registered trademarks are the property of PAG Ltd.
All third party trademarks are acknowledged as such.
Copyright © 2023 PAG Ltd. All rights reserved

3
Section Page
1 Overview 4
2 Specifications 6
3 Operating Instructions 7
4 Servicing 11
5 Guarantee 12
Contents
Thank you for choosing the PAGlink PowerHub.
Please read the important safety information
and instructions before using your PowerHub.

1. Overview
Plug-in Output Unit PAGlink Contacts
PAGlink Contacts Hub Release
USB Module
Front
Back
Output Unit Release
• PAGlink batteries provide up to 12A, when linked, which is suitable for
most cameras and multiple accessories.
• The PAGlink PowerHub is supplied with 4 D-Tap outputs, for 12V camera
accessories such as an on-board light, a monitor, a transmission device
and audio equipment. A USB output is incorporated that allows you to
power 5V camera accessories that draw up to 2A, or to charge your
phone.
V-Mount PowerHub
4
• The PAGlink battery system allows power to be drawn from the battery
linking contacts. The power can be accessed by attaching the low-
profile and lightweight PAGlink PowerHub which provides the necessary
outputs.
• PAGlink PowerHub is available for both the V-Mount and Gold Mount
PAGlink battery systems.
The PowerHub should be positioned between two
PAGlink batteries. This enables you to hot-swap
batteries for continuous power without unplugging
your accessories.

1. Overview
5
USB
Module
D-Tap
Modules
Module
Release
Button
Front
Back
Gold Mount PowerHub
The PowerHub should be positioned between two
PAGlink batteries. This enables you to hot-swap
batteries for continuous power without unplugging
your accessories.
• The 4 D-Tap output units are interchangeable with Hirose (4-pin), Lemo
(2-pin), 2.1mm (PP90) and USB (Gold Mount version) plug-in output
units, available to purchase individually.
• The plug-in output units allow you to reposition the outputs to the left
or right side of the camera (V-Mount version only), and to swap output
types, thereby customising the PowerHub to your individual
requirement. The output units are easily removed by using the red
release buttons.

2. Specifications
6
2.1 Models covered by these instructions:
Model 9709 PAGlink PowerHub V-Mount
Model 9712 PAGlink PowerHub Gold Mount
2.2 Suitable Batteries:
The PowerHub is designed for use with PAGlink batteries only. It
cannot be connected directly to the camera or used with non-PAGlink
batteries.
PowerHub V-Mount (9709) can be used with:
PAGlink PL96e Model 9303
PAGlink PL96T Model 9304
PAGlink PL150e Model 9308
PAGlink PL150T Model 9309
PowerHub Gold Mount (9712) can be used with:
PAGlink HC-PL94T Model 9306
PAGlink HC-PL150T Model 9313
2.3 D-Tap Outputs:
The PowerHub is supplied with 4 x D-Tap output units suitable for 12V
camera accessories. The output is unregulated. The units are
interchangeable with other types including Hirose (4-pin),
Lemo (2-pin), 2.1mm (PP90), and USB (Gold Mount version only),
available separately.
2.4 USB Output:
The USB output is regulated at 5V (2 Amps).
The Gold Mount PowerHub USB output unit is interchangeable with
other output units and can be situated in any of the 5 available
output ports.
2.5 Dimensions (L x W x H):
V-Mount Model:
112 x 83 x 18mm
4.4” x 3.2” x 0.7”
Gold Mount Model:
114 x 89 x 25mm
4.5” x 3.5” x 1.0”
2.6 Weight:
V-Mount Model:
100g (3.5oz).
Gold Mount Model:
140g (5oz).

3. Operating Instructions
7
3.1 To connect the V-Mount PowerHub to the battery, align the PowerHub
with the face of the battery and slide the Hub downwards until it
engages with a ‘click’. To remove the PowerHub from the battery, press
the release button on the left side of the PowerHub and slide the unit
up until it is free.
PUSH DOWN
TO CONNECT
PRESS TO
RELEASE
3.2 To connect the Gold Mount PowerHub to the battery, align the studs
on the rear of the PowerHub with the locators on the front of the
battery, and slide the PowerHub towards the right, until it engages
with a ‘click’. The white locking indicator on the PowerHub release
button will be visible, indicating that it is locked-in position. To
remove the PowerHub, press the release button situated on the left
side of the PowerHub and slide the PowerHub to the left until it is
free.
SLIDE RIGHT
TO CONNECT
PRESS TO
RELEASE

3. Operating Instructions
OUTPUT
RELEASE
BUTTONS
3.3 To remove an output unit from the V-Mount PowerHub, slide the
corresponding red button away from the unit and pull the unit out.
To insert an output unit simply align the sprues with the slots in the
output port, ensure that the 2 banana pins are correctly aligned, and
push-in the unit, until it locks with a click.
3.4 The USB output unit for the V-Mount PowerHub is situated at the base
of the Hub. It can be used to power any 5V device that draws up to
2A continuously, 3A peak; or it can be used to charge your phone.
It also incorporates voltage output protection.
8
To remove the USB output unit from the V-Mount PowerHub, first
remove the lower left and right output units either side of the USB
unit, and then lift it out.

3. Operating Instructions
OUTPUT
UNIT
RELEASE
BUTTON
3.5 To remove any of the output units from the Gold Mount PowerHub,
first push-up and hold the central red release button on the front
face, then pull out the unit you wish to remove.
To insert an output unit, align its sprue and slot with those on the
PowerHub port, ensure that the 2 banana pins are correctly aligned,
and push-in the unit until it locks with a ‘click’. Any of the output
units can be used in any of the output ports.
9
3.6 PowerHub V-Mount Output Units:
Hirose (4-pin)
Model 9709H
D-Tap
Model 9709D
Lemo (2-pin)
Model 9709L
2.1mm (PP90)
Model 9709P
USB (5V 2A)
Model 9709U

3. Operating Instructions
10
3.7 PowerHub Gold Mount Output Units:
Hirose (4-pin)
Model 9712H
D-Tap
Model 9712D
Lemo (2-pin)
Model 9712L
2.1mm (PP90)
Model 9712P
USB (5V 2A)
Model 9712U

4. Servicing
4.1 The PAGlink PowerHub does not require periodic maintenance,
consequently there are no user-serviceable parts inside.
4.2 If the PowerHub becomes damaged or a fault develops, seek advice
from your nearest authorised PAG Service Centre:
Europe & Middle East: Aspectra
Spoorhaven 78, 2651 AV, Berkel en Rodenrijs, The Netherlands
Tel: +31 (10) 5140680, Email: info@aspectra.nl
UK & RoW: PAG Ltd.
Epsom Downs Metro Centre, Units 9 & 10, Waterfield, Tadworth, Surrey,
KT20 5LR, United Kingdom
The Americas: PAG America (part of the Carr Distribution Group)
18 Center Street, Ramsey, NJ 07446, USA
Tel: +1 631 300 8215 , Email: sales@pagamerica.com
4.3 PAG TECHNICAL INFORMATION:
For further technical information, please contact your nearest PAG
Authorised Service Centre.
11

5. Guarantee
5.1 Notwithstanding any provision of any agreement the following
guarantee is exclusive: PAG Limited guarantees each PowerHub it
manufactures to be free of defects in material and workmanship under
use and service for 2 YEARS from the date of purchase. This guarantee
extends only to the original purchaser. This guarantee shall not apply
to fuses or any product or parts which have been subject to misuse,
neglect, accident or abnormal conditions of operation.
5.2 In the event of failure of a product covered by this guarantee, PAG
Limited will repair and calibrate equipment returned to an authorised
Service Facility within the period of the guarantee, provided the
guarantor’s examination discloses to its satisfaction the product was
defective. The guarantor may, at its option, replace the product in lieu
of repair. With regard to any equipment returned within this period,
said repairs or replacements will be made without charge. If the failure
has been caused by misuse, neglect, accident or abnormal conditions
of operation, repairs will be billed at a nominal cost. In such a case,
an estimate will be submitted before work is started, if requested.
For more information visit www.paguk.com
12
Table of contents
Other PAG Power Supply manuals
Popular Power Supply manuals by other brands

HP
HP ProCurve 1600M Installation and Removal

Good Will Instrument
Good Will Instrument PSB-2000 series user manual

Rolls
Rolls PB223 user guide

Horizont
Horizont Hotline Gemini 40 Installation guide and warranty

Matsusada Precision
Matsusada Precision R4G Series Basic instruction manual

Vanderbilt
Vanderbilt SPC42 Series Installation & configuration manual