PagePac V-5323006 User manual

ISSUE 3
1 947176
by
PagePac®
PAGEPAC 6
V-5323006
INTRODUCTION
PagePac 6 is a compact, 6 Watt, voice-paging system that
integrates single-zone paging capability to your telephone
system.
Dimensions/Weight
• 6.00”W x 2.50”H x 3.30”D
(15.2cm x 6.4cm x 8.3cm)
• 2.0lbs. (0.9 kg)
SPECIFICATIONS
FEATURES
• Connects to telephone system through standard modular telephone cords.
• Connects to voice coil speakers or horns.
• Provides a 6-Watt, voice coil output.
• Controls background music provided from a line level source.
• Includes 12VAC power supply that plugs into any standard 120VAC, 60 Hz outlet.
• Connects directly to telephone system page port (Page port must provide a dry
contact closure).
•Requires separately purchased adapters for telephone systems without page port
connections (Trunk Adapter & Page Pal).
INSTALLATION
There are several ways to connect PagePac 6 to your telephone system.
• For telephone systems equipped with a page port that has a contact closure, the
PagePac 6 connects directly to the page port (see Figure 1).
NOTE: For those telephone systems not equipped with a page port, a choice of adapters
is available.

2
Figure 1. PagePac®6 Connections to Telephone System Equipped with Page
Page Port and a Contact Closure
CONNECTING PAGEPAC®6 TO A PAGE PORT WITH A CONTACT CLOSURE
INSTALLATION PROCEDURE
•PagePac 6 can be placed on a desk or shelf or wall-mounted using the keyhole slot in the
bottom of the unit.
•Circled numbers in Figure 2 correspond to the steps in the following installation procedures.
Figure 2. Connections to a Page Port with RJ-11 Jack
After selecting a convenient location:
• Connect the page jack on the Page Pac 6 to the telephone system page jack with a modular
cord.
Note: If the page port has screw-type connections, use a half-modular cord to connect to
the page port. The modular end of the cord connects to the PagePac 6 PAGE jack.
On the other end of the cord, the green lead to page tip, and the red lead connects
to page ring. The black and yellow leads are control leads that connect to a dry
contact closure provided by the page port.
Plug the PagePac 6 power cord into a standard AC wall outlet.

3
Note: The Canadian equivalent to the RJ-11C connector is CA-11A. Where applicable, CA-11A
is to be understood for other references to RJ-11C in the manual.
CONNECTING PAGEPAC 6 USING A PAGEPAC TRUNK ADAPTER
INSTALLATION PROCEDURE
After selecting a convenient location:
NOTE: Trunk Adapter connects PagePac 6 to vacant CO line port of telephone system.
Circled numbers in Figure 3 correspond to the steps in the installation procedure.Note:
1. Connect the Trunk Adapter modular cord to the PagePac 6 PAGE jack.
2. Connect the Trunk Adapter power cord to the PagePac 6 POWER OUT jack.
3. Connect the Trunk Adapter jack J2 to the telephone system trunk line jack (the jack which will
be dedicated for paging) with a standard modular cord.
4. Plug the PagePac 6 power cord into a standard AC wall outlet.
Figure 3. Connections to a Line Jack Using the PagePac Trunk Adapter
CONNECTING PAGEPAC 6 USING A PAGEPAL
INSTALLATION PROCEDURE
After selecting a convenient location:
Note: Add PagePal to PagePac 6 installation for Override page access, alert tones, CO
port or Station port access, or night bell.
1. Connect terminal 13 of PagePal to green (pin 4) of PagePac 6.
2. Connect terminal 15 of PagePal to red (pin 3) of PagePac 6.
3. Connect terminal 16 of PagePal to yellow (pin 5) of PagePac 6.
4. Connect terminal 17 of PagePal to black (pin 2) of PagePac 6.

4
PAGE
VOL
SPKRS MUSIC IN
MUSIC
VOL PAGE POWER
OUT
AUX
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
RINGER
COMMON
AC/DC
NORMALLY
OPEN
CONTACTS
for
REMOTE
AMP CONTROL
OUTPUT
600OHM
+ -
+ -+ -
MUSIC INPUT
100k OHM
2.5 VMAX
ATTENDANT
INPUT
600 OHM
+10dB MAX
NOPRE-ANNC
TONE
NOCONFIRMOR
PRE-ANNCTONE
TONE2CHIME
TONE1SIREN
ATTENDANT
ACCESS
GROUND
C1
RING
TIP
C
PHONE SYSTEM NIGHT BELL INPUT
RGYB
PagePac 6
PagePal
Phone System
Figure 4. Connections to a PagePac 6 Using a PagePal
CONNECTING SPEAKERS TO PAGEPAC 6
Both standard speakers (indoor cone-type) and horn speakers may be used with PagePac 6. For
best performance, use only the type speaker recommended for your situation (see Table 1) and do
not exceed the number of speakers or speaker run length maximums shown in Table 2.
Table 1. Recommended Speakers
Paging Area Mounting Location Speaker Type Valcom Order No.
On Wall or Ceiling Universal Cabinet V-5330105Open or Closed Office
Areas, Conference
Rooms Etc.. Above the Ceiling Recessed Ceiling V-5330115
Hallways On Wall or Ceiling Universal Cabinet V-5330105
Private Office Placed on Desk or Wall Desktop or Wall V-5330110
Open Industrial Area or
Outdoors
On Wall or Pole at Least
15 Ft. Above Ground
1 Watt Horn` V-5330010
Table 2. Speaker Limitations
Standard Indoor Speakers Horn Speakers
Total Speakers 24 at ¼ Watt 6 at 1 Watt
Speakers Per Run 5 1

5
Maximum Length of Speaker Run
(24 Awg Copper Wire)
Maximum Length of Speaker Run
(22 AWG Copper Wire)
100 Feet
500 Feet
100 Feet
300 Feet
Notes: 1. A run is a line of one or more speakers that connects directly to PagePac 6. If using both horns and
standard speakers, each horn counts as four standard speakers.
In some situations you may be able to extend a run farther than 100 feet, by using fewer speakers and/or
larger diameter wire.

6
Figure 5. Connecting Speakers
CONNECTING MUSIC SOURCE TO PAGEPAC®6
REQUIRED MATERIALS
•An external music source, such as FM tuner, tape deck, leased source, etc.
• Wire for making connection between music source and PagePac 6. Speaker wire (24 AWG)
may be used for this purpose.
INSTALLATION PROCEDURE
1. Connect audio output of music source (see Figure 6) to the PagePac 6 MUSIC IN terminals.
2. Turn on the music source.
3. Select a station and set the volume control on the music source, then use the MUSIC VOL
control on the PagePac 6 to adjust the volume, as described in Operation Section.
NOTES:
If, during a page, you hear music in the speakers or phone, reverse the position of the
wires on the MUSIC IN terminals.
PAGE
VOL
SPKRS MUSIC IN
MUSIC
VOL PAGE POWER
OUT
AUX
PagePac 6
FIRST RUN SPEAKERS
SECOND RUN SPEAKERS
THIRD RUN SPEAKERS

7
Figure 6. Connections Using an External Music Source
Those who use paging systems to rebroadcast copyrighted music are required to obtain licenses
from and pay fees to copyright owners. This usually involves obtaining licenses and paying fees to
either ASCAP and/or BMI (American Society of Composers, Artists and Producers, Broadcast
Music Inc.). It is the user's obligation to obtain any license required and pay any fees.
Whenever possible, the PagePac 6 paging system should be plugged into the same AC power
receptacle as the voice system.
OPERATION
Paging procedures differ depending on the requirements of your telephone system and how it is
connected to PagePac 6. If your system is connected using a PagePac®6 Port Saver, pay
particular attention to the pertinent instruction section below.
PAGING WHEN CONNECTED THROUGH A PAGE PORT OR A PAGEPAC®
TRUNK ADAPTER
The exact procedure for paging on your particular telephone system is explained in the user's
manual that accompanies the telephone system. In general, though, the steps are as follows:
1. Access the paging function as required by your telephone system. If PagePac 6 is connected
through a page port, you will probably push a button or dial a code to access the function. If
PagePac 6 is connected through a PagePac Trunk Adapter, you will follow your telephone
system’s requirements for accessing the line reserved for paging.
2. Make the page.
3. Replace the telephone handset gently (remember you are still connected to the loudspeaker).
This will prevent loud noises from being heard over the paging system.
ADJUSTING PAGE AND MUSIC VOLUME
Volume controls on the rear of PagePac 6 allow you to adjust the volume of paging and
background music independently.
To adjust paging volume, turn the PAGE VOL control clockwise to increase or counterclockwise to
decrease volume.

8
To adjust background music volume, turn the MUSIC VOL control clockwise to increase or
counterclockwise to decrease volume. If you do not use background music, turn the MUSIC VOL
control fully counterclockwise.
Note: PAGE VOL should be adjusted first, then MUSIC VOL.
MAINTENANCE
The PagePac 6 contains no user-serviceable parts, and should be repaired only by authorized
personnel. There are several types of installation and maintenance plans available from Valcom or
your dealer. For information or warranty service, call your Valcom sales representative or
authorized dealer.
TROUBLESHOOTING PROCEDURES
If your paging system fails to operate properly, follow the suggestions in the “Trouble Analysis
Table” (see Table 3) before calling for professional assistance.
Table 3. Trouble Analysis Table
Problems Corrective Action
Check volume control on problem speaker(s).
Check all connections to speakers.
Replace inoperative speaker with good one. If speaker cannot be replaced
immediately, wire around it to ensure service to the remaining speakers.
No sound from one or more
speakers while others work.
Note: Look for a mix of voice coil and 70 Volt speakers. Replace all
70Volt speakers with voice coil type. Refer to Table 2-1.
Ensure that the power supply is plugged in and that the outlet has power.
Check the volume controls on the rear of PagePac 6.
Check the speaker connections.
Isolate the source of the problem using a test set.
NOTE: Look for a mix of voice coil ad 70Volt speakers. Replace all 70Volt
speakers with voice type. Refer to Table 2-1.
If Connected Using a Trunk Adapter.
1. Disconnect the Trunk Adapter from line jack.
2. Connect a 2500-Type telephone to Trunk Adapter jack J2.
Paging and music do not
work. Or, music works but
paging does not.
3. If the PagePac 6 is working, you will be able to page using the
telephone. Music should also work and be switched out during a
page.
Paging and music are
garbled.
Check speaker wire for shorts. Look for staples driven through wire. Check all
connections.
Paging works, but music
does not.
Ensure music source has power. Adjust PagePac 6 MUSIC VOL control.
Adjust volume control on music source. Tune music source to strong station.
Check all connections.
If, for any reason, you need to know the pinouts for the modular jacks on the PagePac 6, pinout
information is given in Tables 4.

9
Table 4. PagePac®6 PAGE Jack
Pin 1 Cord Lead 2 Function Connect to Paging Port
1Not Used Not Used Not Used
2Black Access Control ( C ) Dry Contact Closure ( C )
3Red Ring Ring
4Green Tip Tip
5Yellow Access Control ( C ) Dry Contact Closure ( C )
6Not Used Not Used Not Used
Notes:
1. Pin number from left to right, as seen when looking into jack.
TECHNICAL ASSISTANCE
When calling, have a VOM and a telephone test set available and call from the job site.
Call (540) 563-2000 and press 1 for PagePac Technical Support or visit our websites at
http://www.pagepac.com and www.valcom.com.
Should repairs be necessary, attach a tag to the unit clearly stating company name, address,
phone number, contact person and the nature of the problem. Send the unit to:
Valcom, Inc.
PagePac®Repair Dept.
5614 Hollins Road
Roanoke, VA 24019-5056
FCC REGULATIONS PERTAINING TO THIS EQUIPMENT
FCC (PART 15)
Radio Frequency Interference
The PagePac 6 generates and uses radio-frequency energy and if not installed and used in strict
accordance with the manufacturer’s instructions, may cause interference to radio and television
reception. Testing has been conducted for compliance with the limits for a Class B device in
accordance with the specifications in Subpart J of Part 15 of the FCC Rules. This testing is
designed to provide reasonable protection against such interference. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
interference to radio or television reception, which can be determined by turning the PagePac unit
off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient the radio or TV receiving antenna.
• Relocate the PagePac with respect to the radio or TV receiver or vice-versa
• Plug the PagePac 6 into a different outlet so that it and the radio or TV receiver are on different
branch circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for
additional suggestions. The user may find the following booklet, “How To Identify and Resolve
Radio-TV Interference Problems,” helpful. This booklet was prepared by the Federal Government
printing Office, Washington, DC 20402. Stock order No. 004-000-00345-4.

10
FCC (PART 68)
This equipment is registered with the Federal Communications Commission (FCC) in accordance
with Part 68 of its Rules. The FCC requires that the manufacturer provide you with the following
information:
1. Connection and Use with Nationwide Telephone Network
The FCC requires that you connect your telephone equipment to the nationwide telephone network
through a modular telephone outlet or jack. The modular telephone outlet or jack to which the
equipment must be connected is a USOC RJ-11C.
Registered equipment may not be used with Coin Telephone Lines. Equipment may be used with
Party Lines in areas where state tariffs permit such connections and when equipment is adaptable
for such use.
2. Information You May Need to Supply the Telephone Company
Upon request of your local telephone company, you are required to provide them with the following
information.
A. The lines to which you will connect the telephone equipment.
Note: In Canada, the Document Registration Number appears on the maple-leaf label and
the Load Number is under the maple-leaf label.
B. The FCC registration number and Ringer Equivalence Number (REN). Both numbers are
listed on the equipment label. The REN is useful to determine how many devices you may
connect to your telephone line and still have them ring when your telephone lines is called.
In most, but not all, areas, the sum of all RENs per line should be 5 or less. You may want
to contact your local telephone company. The local telephone company must also be
notified upon final disconnection of the equipment from the local telephone company lines.
CSA REGULATIONS PERTAINING TO THIS EQUIPMENT
This product is UL Listed and CSA Certified.
NOTICE:
The Canadian Department of Communications label identifies certified equipment. This certification
means that the equipment meets certain telecommunications network protective operational and
safety requirements. The Department does not guarantee the equipment will operate to the user’s
satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the
facilities of the local telecommunications company. The equipment must also be installed using an
acceptable method of connection. In some cases, the company’s inside wiring associated with a
single line individual service may be extended by means of a certified connector assembly
(telephone extension cord). The customer should be aware that compliance with the above
conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility
designated by the supplier. Any repairs or alterations made by the user to this equipment, or
equipment malfunctions, may give the telecommunications company cause to request the user to
disconnect the equipment.

11
Users should ensure for their own protection that the electrical ground connections of the power
utility, telephone lines and internal metallic water pipe system, if present, are connected together.
This precaution may be particularly important in rural areas.
CAUTION:
User should not attempt to make such connections themselves,
but should contact the appropriate electric inspection authority
or electrician, as appropriate
SECONDARY CIRCUIT PROTECTION
IMPORTANT INFORMATION
This equipment is for use on telephone wiring containing a secondary circuit protector. This paging
equipment requires a secondary circuit protector where applicable (see Figure 7).
The secondary circuit protector must be located between the primary protector and the paging
equipment. Refer to the Safety Information below.
Figure 7. Example Configuration Requiring Secondary Protection
When Paging Equipment is Connected Directly to the Telephone Network

12
SAFETY INFORMATION
• The secondary circuit protector is used when connecting paging equipment directly to telephone
lines that may be exposed to high voltage power lines.
• Never install telephone wiring during a lightning storm.
• Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
• Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
• Use caution when installing or modifying telephone lines.
• Use appropriate Valcom approved device.
This manual suits for next models
1
Table of contents