Pain Management Technologies Ultima OTC User manual

MA
NUF
AC
TURED
FOR
"
• - I
PAIN
MANAGEMENT
I
TECHNOLOGIES
~I,.
l
LT/MAOTC
USER
MANUAL

A ATTENTION: READ
ALL
CAUTIONS
AND
WARNINGS
BEFORE
USING
YOUR ULTIMA
OTC
DEVICE
CONTRAINOICATIONS
•
Do
not
use
this
device
if
you have a cardiac pacemaker,
implanted defibrillator,
or
other
implanted metallic
or
electronic device. Such use could cause electric shock.
burns,
or
electrical interference
or
death.
WARNINGS
•
Do
not
use the device across
or
through
your chest. Ifyou
are susceptible
to
heart
rhythm disturbances, use of
the
device
must
be
done under the direction of a physician.
• Stop using the device and consult with your physician
if
your pain does
not
improve, becomes
more
severe,
or
lasts
more
than five days, as
this
may indicate a severe
condition.
• Use of
the
device
on
the following skin conditions may
cause a condition
to
become worse.
Do
not
use the device
over,
or
in
proximityto, these skin conditions: abnormal
skin, skin
that
is
not
intact, uncleaned, unhealthy, open
wounds, rashes, swollen, red, infected, inflamed areas,
skin eruptions,
or
cancerous lesions.
• Electrical stimulation during common activities may
increase the risk of injury.
Do
not
use
the
device when
in
the bath
or
shower, sleeping, driving, operating of
machinery
or
any activity
in
which electrical stimulation
can
put
you
at
risk of injury.
•
Do
not
use the device
on
children
or
let
children handle
the device. Do
not
use
this
device
if
you are pregnant,
or
suspect
that
you are pregnant, unless under
the
direction
of your physician.
Do
not
apply the device across your
head.
PRECAUTIONS
• Using the device when you have suspected
or
diagnosed
epilepsy
or
heart
disease may cause unexpected
reactions. Always consultyour physician before using the
device.
WARRANTY
Your
Ultima
OTC
device is covered by a 1-year,
no questions asked
warranty
against all
manufacturers
defects. Call
1-800-239-7880
or
visit paintechnology.com
to
learn more.

TROUBLESHOOTING
Little
or
no
impulse output from
electrodes [the intensity
is
not
felt)
Check the contact of leadwires and electrodes.
Check the electrodes adhesive quality. If they
loose the adhesive quality, please apply fine
spray of
water
to
reactivate the adhesiveness.
If battery symbols are flashing, replace
batteries.
Device does
not
power
on
Ensure batteries are inserted correctly
according
to
the indication
on
battery
compartment. Replace with new batteries.
Difficult
to
attach
the
pads
to
the
skin
Do
not
use
is
perspiring. If pads were attached
after
washing, sufficiently dry pads before
applying. If the adhesive of the pads
is
damaged,
replace with new pads.
The skin
turns
red
or
the
skin feels
irritated
If the adhesive pads are dirty, wash adhesive
surface of pads softly with fingertips
for
under
slow running clean
water
about several seconds.
Your therapy time may
be
too long. Stop using
the device until skin condition recovers.
l
fJ
LTIMA
OTC
Congratulations
on
your
purchase
of
the
Ultima
OTC.
This
innovative
technology
is a
safe,
drug-free,
and
easy
to
use
solution
to
help
manage
your
pain.
Read
this
User
Manual
carefully
before
you
start
using
your
Ultima
OTC unit.
HOW
DOES TENS WORK?
TENS
[Transcutaneous
Electrical
Nerve
Stimulaiton)
is believed
to
work
by
stimulating
your
own
body's
natural
defense
against
pain.
The
unit
produces
a
gentle
stimulus
through
the
pads
normally
placed
over
the
area
of
pain.
This
stimulus
helps
the
body
to
produce
natural
pain
relievers
called
endorphins.
The
correct
positioning
of
the
pads
is
important.
Some
people feel
immediate
benefit
from
TENS,
however
some
may
only
achieve
benefit
after
repeated
treatment
sessions
and
over
an
extended
period
of
time.

PACKAGE CONTENTS
Your
Ultima
OTC
package should contain
the
following:
•
Ultima
OTC
TENS Device
• 4
Self
Adhesive
Electrode
Pada
• Lead
Wires
• 2
AA
Batteries
HOW
TO
ASSEMBLE
YOUR DEVICE
1. Remove
the
battery
cover
and
insert
two
batteries
inside
the
battery
compartment.
Replace
the
battery
cover.
2.
Decide
wether
you wish
to
use
the
unit
with
one lead
or
two.
If
using
two
leads,
insert
the
lead
wire
plugs
into
both
jacks
on
the
device.
If
using one lead, only
insert
one
plug.
ELECTRODE
PLACEMENT
GUIDE
ANKLE SPRAIN
Using
both
lead wires, place pads over
the top
and base
of
the
knee. Avoid placing
directly
on
the
kneecap.

ELECTRODE PLACEMENT GUIDE
CALF
Place pads
on
the
calf/leg
where
you feel pain.
There
are
two
placement options as follow:
\
HOW
TO
ASSEMBLE YOUR DEVICE
3. Remove
the
electrodes
from
the
bag and
connect
them
to
the
other
end of
the
leads.
4. Select your electrode placement location, and
thoroughly clean and
dry
your skin before
positioning
the
electrodes. Reccomended
electrode placement
for
each
preset
can be
found
in
the
back
of
this
manual.
5. Consult
the
next section
to
select your
treatment
mode and begin using
your
device.

DEVICE OPERATION
foW\
~
The
ON/OFF
key is used
to
power
on
and off your TENS
device.
When
powering on,
the
device intensity always
starts
at
zero.
Use
the
PROG
key
to
select between
8 the
preset
treatment
programs.
PROG
They are identified
on
the device
screen
by
arrows
pointing
to
the
specific pain area.
~
The HAND key lets
you
quickly
~
access the hand
treatment
preset.
r;;:;:;;"\ The BACK
key
lets
you
quickly
~
access the lower back
treatment
preset.
~
The
FOOT
key lets
you
quickly
~
access
the
foot
treatment
preset.
Use the
UP
and DOWN keys
to
scroll through
preset
programs
within a specific
treatment
area
category.
The START/PAUSE
key
is used
to
start
or
pause your
treatment
program. The LIGHT
key
will activate
the
backlight
on
the
LCD
display.
The intensity knobs are located
at
the
top
of
your device. Use these
two
rotary
knobs
to
adjust the level
of
treatment
intensity
for
each
individual channel.
ELECTRODE PLACEMENT GUIDE
KNEE
PAIN
Using both lead wires, place pads over
the top
and base of the knee. Avoid placing directly
on
the
kneecap.

ELECTRODE
PLACEMENT
GUIDE
HIP/
THIGH
Using both lead wires, place
the
pads
from
one
wire
either
side
of
the
spine, on
your
lower
back.
Then place
the
pads
from
the
second wire,
on
the
area
of
pain,
on
your hip.
DEVICE FEATURES
1.
When
changing presets,
the
intensitywill
automatically be
reset
to
zero.
2.
When
the
unit
is powered on,
it
will
automatically recall
the
preset
used in
the
previous
treatment
session.
3. The
two
knobs on
top
of
the
device
control
the
intensity by
turning
clockwise
or
counter-clockwise.
4.
When
the
batteries
begin
to
run
low, the
LCD
will display a flashing
battery
indicator
icon.
5.
When
the
device intensity levels
are
set
to
zero, and
the
device has
not
been in use
for
five minutes,
the
unit
will
shut
off
automatically.
TREATMENT
SESSIONS
To begin a
treatment
session, complete
the
following steps:
1.
After
you have positioned
your
electrodes and
connected
the
leadwires
to
both
your
device
and electrodes, Press
the
ON
1
OFF
key
to
power
on
your
device.
2. Use
the
PROG
key
to
select
your
desired
program. You can also use
the
ARM, BACK,
or
LEG
keys
to
jump quickly
to
the
programs
for
each area. The UP and DOWN keys can
be used
to
select a sub-program
from
within
these categories.

TREATMENT SESSIONS
cont.
3. Once
you
have selected your
treatment
program. press the START
I
PAUSE
key
to
begin
the
program. Use
the
intensity knobs
at
the
top of the device
to
slowly increase
or
decrease the intensity. Intensity should
be
increased until
you
feel a slight tingle
in
the
treatment
area.
4. Once
the
program reaches
the
end of its
preset
time, the device will
reset
the output
intensity
to
zero and end
the
program. You
can then choose
to
run another program,
or
power off your device.
5. Once your
treatment
session has ended,
remove your electrodes and
return
them
to
their
packaging. Refer
to
the
next section
for
proper
electrode care.
ELECTRODE PADS
The pads supplied with your Ultima
OTC
device
are self-adhesive and can
be
used several times.
Pads should
be
removed periodically
to
allow
skin
to
breathe.
When
not
in
use, the pads
should
be
placed onto the clear plastic shield.
The condition of
the
pads does affect the
conductivity, and
therefore
the
performance of
the
unit.
When
the pads initially lose
their
adhesive quality,
it
is possible
to
reactivate
their
adhesivesness
by
applying a fine spray of water.
Once the pads have finally lost
their
adhesive
quality, new pads should be purchased.
ELECTRODE
PLACEMENT
GUIDE
WRIST PAIN
You can use a single channel [CH1
),
place
the
couple
of
electrodes
over
the
area
of
maximum
pain, involving
both
sides
of
the
wrist.

ELECTRODE PLACEMENT GUIDE
SHOULDER/
DELTOID
Using
both
leads, position electrode pads
either
side
of
the
spine,
at
the
site
of
pain. Do
not
place
on
the
backbone
or
spine.
ELECTRODE PLACEMENT GUIDE
The following pages detail each
preset
program,
and include illustrations detailing recommended
electrode placement
for
each.
Please study
the
body maps in
this
guide, which
show you
correct
positioning
of
the
electrodes
depending on
your
symptoms.
At
the
end
of
each lead
wire
you will find red and
blackadapters.These
are
cathode and anode
respectively. The following general points
are
made
for
your
information:
1.
More
sensation
tends
to
come
from
the
black
adapter
[cathode).
2.
Where
applicable place
the
black
adapter
closer
to
the
spinal column; e.
g.
if
the
arm
is
to
be treated, place
the
black
adapter
higher
up
the
arm
than
the
red adapter.

ELECTRODE
PLACEMENT
GUIDE
LOWER
BACK
Using both leads, position electrode pads
either
side
of
the
spine,
at
the
site
of pain. Do
not
place
on
the
backbone
or
spine.
1N.
QzR
ELECTRODE
PLACEMENT
GUIDE
SCIATICA
Using both leads, position electrode pads
either
side
of
the
spine,
at
the
site
of
pain. Do
not
place
on
the
backbone
or
spine.
Table of contents
Other Pain Management Technologies Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Vermeiren
Vermeiren SLINGS Albatros instruction manual

Eickemeyer
Eickemeyer CryoIQ DERM plus user manual

Benchmark Scientific
Benchmark Scientific MyGel E1201-E operating manual

Drive
Drive 15300 Owner's assembly and operating manual

KCI
KCI ActiV.A.C. reference guide

Gate
Gate Bure Ortho 56-317T Instructions for use