<Note 1>  While the unit is in the SWING mode (swing/ap), the ap cannot be stopped in a 
desired position.
<Note 2>  When Setting OFF is selected, “°C” is displayed on the LCD.
<Note 3>  You can toggle between ON and OFF by pressing ventilation “( ) button” for 4 seconds 
or more.
<Note 4>  If the Heater Max ON/OFF setting is not changed to EP (ON), the setting change will 
not be reected.
<Note 5>  This is the number of addresses that can be set in the address change mode. Do not 
set it to 07 or above.
Preparation:   
Turn on the circuit breaker of units and then turn the power on. After the power is turned 
on, remote controller operation is ignored for approx. 1 minute because setting is being 
made. This is not malfunction. (Contents received while setting are disabled.)
1.  To start test operation, press and hold the emergency operation button for 10 seconds.
2.  The indication lamps (OPERATION, TIMER, STANDBY) blink during test operation.
3.  To nish test operation, press and hold the emergency operation button for 10 seconds.
Attention
Do not use this mode for purposes other than 
the test operation.  
(To prevent overload of the units)
Read the installation instructions supplied with the units.
Any of the Heat, Cool and Fan operations can 
only be performed.
Temperature cannot be changed.
The test operation mode is automatically 
turned o in 60 minutes.  
(To prevent continuous test operation) 
Outdoor units do not operate for approx. 3  
minutes after the power is turned on or 
operation is stopped.
1-7. Test Operation
When more than 1 receiver is installed in the same room, setting addresses prevents 
interference.
For how to change addresses of wireless remote controllers, see the operating instructions of 
wireless remote controllers.
 To change the receiver’s address, remove the cover from the receiver’s PCB and set No.1 to 
No.3 of the [003] DIP switch on PCB.
Remote 
Controller 
Address 
Display
Address Address Address Address Address Address Address ON/OFF 
States
ALL123456
Position 
of the 
receiver’s 
address 
switch
Receipt is 
possible 
at all 
of the 
address 
positions
123412341234123412341234OFF ON
1-6. Setting Address Switches
1-9. Room Temperature Sensor Settings
The indoor unit and the wireless remote controller are equipped with 
room temperature sensors. The sensing of room temperature works 
via one of them.
 When the unit is shipped, it is set to the indoor unit. To switch it to the 
remote controller, press the sensor button (the gure on the right) 
inside the remote controller’s cover and then check that Main Sensor 
 on the LCD screen goes o.
<Note> Be sure to install the remote controller so as to face the 
receiver.
 If the unit does not receive any room temperature data from 
the remote controller for ten minutes even with its sensing 
function activated, the indoor unit sensor will automatically 
start sensing the room temperature.
Sensor button
1-8. Self-diagnostics table and detected contents
The “Alarm Display” shown in the table below expresses the alarm contents displayed when the 
wired remote controller is connected. For how to handle the alarms, see installation instructions 
of indoor units or technical guide.
Detected contents Indication lamp on the receiver
Alarm Display
OPERATION TIMER STANDBY
Blinking
Communication error in the remote 
controller circuit
E01–E03, E08–E14, 
E17, E18 ◎ 
Communication error either in the in/
outdoor operation line or the sub-bus of 
the outdoor unit
E04–E07, E15, E16, 
E19–E31   ◎
Operation of indoor protection device P01, P09–P14 ◎ ◎
Alternately
Operation of outdoor protection device P02–P08, P15–P31 ◎◎
Alternately
Error in the indoor thermistor F01–F03, F10–F11 ◎ ◎ 
Alternately
Error in the outdoor thermistor F04–F09, F12–F28 ◎ ◎ 
Alternately
Error in the indoor EEPROM F29 ◎ ◎ 
Simultaneously
Error in the outdoor EEPROM F30, F31 ◎ ◎ 
Simultaneously
Error related to the compressor H01–H31 ◎
Error in indoor settings L01–L03, L05–L09 ◎◎
Simultaneously
Error in outdoor settings L04, L10–L31 ◎◎
Simultaneously
Error in the gas heat pump air 
conditioner A01-A31 ◎ ◎
Simultaneously
Inconsistency in Cooling/Heating (Including an auto-temp 
setting for a model without auto-temp settings) ◎ ◎
Alternately
Oil alarm (Same as operation of outdoor protection device) ◎◎
Alternately
Test operation ◎ ◎ ◎
Simultaneously
 : OFF  : ON (Illuminated) ◎: Blinking (0.5 seconds interval)
1-10. Setting Up Remote Controller Functions
The functions of the wireless remote controller can be set on site.
(These settings are saved in nonvolatile memory in the remote controller. Therefore, the settings 
do not revert to the defaults even when its batteries are changed.)
<Note>  Only service personnel should make the settings because the operation of the air 
conditioner may be aected, depending on the settings made.  
Furthermore, making changes to these settings may cause actual operation to deviate 
from what is printed in the Operating Instructions, so be sure to fully explain this to the 
customer.
Making Settings (Do with unit stopped)
(1) Holding down the swing/ap ( ) + OFF timer   ( ) + mode select ( ) buttons at the 
same time for 4 or more seconds will open the setting screen. (See gure below.) 
(2) Use the Temperature setting buttons  / ( ) to select the number of the item to be set.
(3) Use the ON timer buttons  / ( ) to change settings.
(4) The settings are saved with the once/every day button ( ). When this is done, the SET 
displayed on the LCD changes from blinking to lighting.
(5) If other settings are to be changed, repeat steps (2) to (4).
(6) When all settings have been made, press the start/stop ( ) button.
Operation procedure and function display
Item 
Number
(1)
(2)
(6)
(3)
(4)
Detected contents Set Contents Factory
setting
1Operation 
Mode
2Flap Display            (No Display)
 (*1)
3Select Fan 
Speed         
 
(No Display)
4Display of Set 
Temperature 
°F   Setting O (*2)   °C °F
5 Time Display
AM/PM   24 Hour (No Display)
AM/PM
6Ventilation Fan 
ON/OFF
OFF (No Display)   ON OFF (*3)
7Cool temp Max 41 to 95°F (05 to 35°C)
86°F (30°C)
8 Cool temp Min 41 to 95°F (05 to 35°C)
64°F (18°C)
9 Heat temp Max 41 to 95°F (05 to 35°C)
86°F (30°C) 
(*4)
10 Heat temp Min 41 to 95°F (05 to 35°C)
60°F (16°C)
11 Dry temp Max 41 to 95°F (05 to 35°C)
86°F (30°C)
12 Dry temp Min 41 to 95°F (05 to 35°C)
64°F (18°C)
13 Auto temp Max 41 to 95°F (05 to 35°C)
80°F (27°C)
14 Auto temp Min 41 to 95°F (05 to 35°C)
62°F (17°C)
16 Address Setting 
Max Value
00 (ALL only)  01 to 031 06(*5)
17 Heat temp Max 
ON/OFF
JP (Heater Max Temp Change 
O)   EP (ON)
JP
 
 
 
 
1-13. Specications
Dimensions (H) 7-11/64” × (W) 2-13/32” × (D) 47/64” 
((H)182 mm × (W) 61 mm × (D)18.5 mm)
Weight 140g (Including batteries)
Power Source Two AAA size batteries
Clock Accuracy ±30 seconds / month (at 77°F (25°C))
Dimensions (H) 2-9/16” × (W) 5-1/8” × (D) 55/64”  
((H) 65 mm × (W)130 mm × (D) 22 mm)
Weight 82g
Power Source DC16V(supplied from indoor unit)
1-11. Installing Wireless Remote Controller
Screw the remote control 
holder.
Remote control holder 
Installing the remote 
controller
2Press
1Insert
Press at the installation location 
on the wall, and check that normal 
receiving is possible.
Remove the remote controller from the 
remote control holder.
Installation location for the Wireless Remote Controller
If a remote controller is to be operated from a remote control holder that is hung on a wall, turn on the lights in 
the room as well as any electrical appliances and then check to make sure the air conditioner works with the 
remote controller in the location where it will be installed. If it works, continue with installation.
 If the main sensor is to be switched from the indoor unit to a remote controller, pay attention to the following 
when installing.
•
  Locate where no warm or cold air will aect it.
•
  Locate in a place free from direct sunlight.
•
  Locate where it will not be aected by any other heat/cold source.
Wireless Remote Controller
Receiver
- 6 -
- 7 -
- 5 -
- 8 -
1-12. When installing the remote controller onto a wall, etc.
CZ-RWSD2U.indd   2 2015-1-7   14:03:39